Fabrication Tolerances

1. Cold-Formed Structural Members


The fabrication tolerances indicated in Figure. 1 for cold-formed structural
members are defined in Table. 1

Figure.1
Cold-Formed Structural Members

Table. 1
2. Built-up structural Members
The fabrication tolerances indicated in figure. 2 & figure. 3 are for built-up structural
members.

in mm

Figure. 2
Built-Up Structural Member
Figure. 3
Built-Up Structural Member
Table. 2
Built-Up Structural Members

Built-up Structural Members


Dimension Tolerances
+ -
3°- 6.3mm Max* 3°- 6.3mm Max*
b 6.3mm 6.3mm
Geometry d 4.8mm 4.8mm
e 3.2 mm 3.2mm
c (mm) 0.00115D mm
f (mm) 0.00115D mm
E1 3.2mm 3.2mm
E2 3.2mm 3.2mm
Hole E3 3.2mm 3.2mm
Location S1 1.6mm 1.6mm
S2 1.6mm 1.6mm
F 3.2mm 3.2mm
Length (L) (mm) 6.4mm 6.4mm
Sweep (S) (mm) Crane Beams 1.04 x L(m)
All Other members 2.08 x L(m)
Camber (C) (mm) 2.08 x L(m)
N1 3.2mm 3.2mm
N2 4.8mm 4.8mm
G1 1.6mm 1.6mm
Splice G2 1.6mm 1.6mm
Plates Up to 600mm 3.2mm 3.2mm
H 600 to 1200mm 4.8mm 4.8mm
Over 1200mm 6.4mm 6.4mm
J 6.4mm 6.4mm
* use 3 degree angle or 6.3mm whichever is critical.