SCHEDULE "C"

PRICING ATTACHMENT
LUMP SUM PRICE BREAKDOWN

Item Description % BREAKDOWN Amount (SR)


1 ENGINEERING PRICE (Maximum 7% of Total Contract Price)
TOTAL DESIGN PRICE #DIV/0! 0.00
2 MATERIALS PRICE
2.1 ENGINEERED MATERIALS #DIV/0! 0.00
2.2 NON-ENGINEERED MATERIALS #DIV/0! 0.00
TOTAL MATERIALS PRICE #DIV/0! 0.00
3 CONSTRUCTION PRICE
3.1 SITE MOBILIZATION COMPLETION #DIV/0! 0.00
3.2 Progress Category as per Sch. "C" Para. 6.3.3 #DIV/0! 0.00
3.3 Milestone Category as per Sch. "C" Para. 6.3.2 #DIV/0! 0.00
3.4 SITE DE-MOBILIZATION & COMPLETION #DIV/0! 0.00
TOTAL CONSTRUCTION PRICE #DIV/0! 0.00
TOTAL LUMP SUM PRICE 0.00
LUMP SUMP PRICE BREAKDOWN
1.1 DETAILED ENGINEERING PRICE
ITEM DESCRIPTION % of Detail Design AMOUNT (SAR)
1.1.1 Progress Payment: (Maximum of 3.5% of Contract Lump Sum Price) #DIV/0!
1.1.1.1 Process #DIV/0! 0.00
1.1.1.2 Civil #DIV/0! 0.00
1.1.1.3 Structure #DIV/0! 0.00
1.1.1.4 Electrical #DIV/0! 0.00
1.1.1.5 Mechanical #DIV/0! 0.00
1.1.1.6 Pipeline/Piping #DIV/0! 0.00
1.1.1.7 Instrumentation #DIV/0! 0.00
1.1.1.8 Communication/Telecommunication #DIV/0! 0.00
1.1.1.9 Common/General Engineering #DIV/0! 0.00

1.1.2 Milestone Payment: (1.5% of Contract Lump Sum Price) #DIV/0!


1.1.2.1 Complete and issue 100% early (IFC) Detailed Design package for site preparation and Early Civil works. #DIV/0! 0.00
1.1.2.2 Complete and issue 60% detail design package #DIV/0! 0.00
1.1.2.3 Submit Hot Tap Tie-in final execution package #DIV/0! 0.00
1.1.2.4 Complete and issue 90% detail design package #DIV/0! 0.00
1.1.2.5 Issuance of 100% IFC Package for additional four Surge Relief Skids, SRS, scope #DIV/0!
1.1.2.6 Complete and issue IFC package inclusive of all Engineering scope. #DIV/0! 0.00
1.1.2.7 Complete PO Placement of equipment and material identified in item 1.9 of Sch B Attachment II #DIV/0!
1.1.2.8 Complete PO Placement of all Project Items/Materials related to Surge Relieve Skids Package #DIV/0!
#DIV/0! 0.00

Total #DIV/0! 0.00


2 MATERIALS PRICE
2.1 ENGINEERED MATERIALS
% of Engineered
ITEM DESCRIPTION Material Price
AMOUNT (SAR)

2.1.1 MECHANICAL (EQUIPMENTS) ENGINEERED MATERIALS #DIV/0! 0.00


2.1.1.1 Scraper Launchers / Receivers
2.1.1.2 Jib Cranes
2.1.1.3 Surge Relief Skids
2.1.1.4 Collection Vessel
2.1.1.5 Pumps
2.1.1.6 All other Mechanical (Equipments) Engineered items
2.1.2 MECHANICAL (PIPING) ENGINEERED MATERIALS #DIV/0! 0.00
2.1.2.1 Pipes
2.1.2.2 Valves
2.1.2.3 SPLIT TEEs
2.1.2.4 Hot tap special fittings.
2.1.2.5 All other Mechanical (Piping) Engineered items
2.1.3 ELECTRICAL ENGINEERED MATERIALS #DIV/0! 0.00
2.1.3.1 CP Rectifier
2.1.3.2 Transformers
2.1.3.3 Monopole OHPL
2.1.3.4 Switchrack
2.1.3.5 Off-Grid Power PV System
2.1.3.6 Solar systems
2.1.3.7 All other Electrical Engineered items
2.1.4 INSTRUMENTATION/COMMUNICATION/SECURITY ENGINEERED MATERIALS #DIV/0! 0.00
2.1.4.1 Remote Terminal Units
2.1.4.2 Fire Alarm Control Panel
2.1.4.3 Interposing Relay Panel
2.1.4.4 Motor Operated Valves (MOVs)
2.1.4.5 Safety Relief Valves
2.1.4.6 Control Valves
2.1.4.7 Emergency Isolation Valves
2.1.4.8 Pressure Relieve Valves
2.1.4.9 PROGRAMMABLE LOGIC CONTROLLER (PLC)
2.1.4.10 EMERGENCY SHUTDOWN SYSTEM (ESD)
2.1.4.11 DISTRIBUTED CONTROL SYSTEM (DCS)
2.1.4.12 All other instrumentation/Comm/Security Engineered items
TOTAL ENGINEERED MATERIALS 0
2.2 NON-ENGINEERED MATERIALS
2.2.1 Civil/Structural Materials #DIV/0! 0.00
Including, but not limited to, Structural Steel, Concrete Read-Mix, Reinforcing Bars, Gratings, Bars, Plates, Gates and Fence, Paints &
2.2.1.1
Coatings, and bulk materials
2.2.2 Electrical Materials #DIV/0! 0.00
2.2.2.1 Including, but not limited to, Power Cables, Panel Boards, Lighting fixtures, Grounding and bulk materials
2.2.3 Mechanical Materials #DIV/0! 0.00
2.2.3.1 Including, but not limited to, all bulk materials
2.2.4 Instrumentation Materials #DIV/0! 0.00
Including, but not limited to, Transmitter, Cables, Conduits, Junction Boxes, Thermowells & RTDs, Horns & Beacons, Indicators, Detectors
2.2.4.1
and bulk materials
2.2.5 Telecomminication Materials #DIV/0! 0.00
2.2.5.1 Including, but not limited to, FOC, Ports, Transmission Equipment, FXS/O Converters, Telephones, and bulk materials
2.2.6 Piping Materials #DIV/0! 0.00
2.2.6.1 Including, but not limited to, Pipe Fittings, Flanges, Spectacle Plates, Hot Tap Fittings, Piping Specialty Items, and bulk materials
TOTAL NON-ENGINEERED MATERIAL PRICE 0
TOTAL ENGINEERED MATERIALS PLUS NON-ENGINEERED MATERIALS 0.00
3 CONSTRUCTION PRICE

Saudi Aramco: Confidential


#
Saudi Aramco: Confidential 1
SCHEDULE "C"
PRICING ATTACHMENT
LUMP SUM PRICE BREAKDOWN

% of Construction
ITEM DESCRIPTION Work
AMOUNT (SAR)

SITE MOBILIZATION COMPLETION (NOT TO EXCEED 2% OF CONSTRUCTION PRICE)


3.1 Milestone Category as per Sch. "C" Para. 6.3.2 and as identified in Schedule “B” Attachment IV including 0.00
(Saudi Aramco Offices, Contractor Offices, Laydown yards and Contractor Camp)
3.2 Progress Category as per Sch. "C" Para. 6.3.3
3.2.1 Treated Gas Pipeline 0.00
3.2.1.1 Treated Gas Pipeline
3.2.1.2 Road Crossings
3.2.1.3 Scraper Facilities (Launcher & Receiver)
3.2.1.4 Hot Taps
3.2.2 Condensate Gas Pipeline 0.00
3.2.2.1 Condensate Gas Pipeline
3.2.2.2 Road Crossings
3.2.2.3 Scraper Facilities (Launcher & Receiver)
3.2.2.4 Hot Taps
3.2.3 AH Crude Oil Pipeline 0.00
3.2.3.1 AH Crude Oil Pipeline
3.2.3.2 Road Crossings
3.2.3.3 Main Line Valves
3.2.3.4 Scraper Facilities (Launcher & Receiver)
3.2.3.5 Jump-Over Areas
3.2.3.6 Hot Taps
3.2.3.7 SRS at MLV No. 1
3.2.3.8 SRS at MLV No. 2
3.2.4 Additional Surge Relief skids 0.00
3.2.4.1 At Ras Tanura Terminal South
3.2.4.2 At Ras Tanura Refienery
3.2.4.3 At Juaymah Junction
3.2.4.4 At Juayah Terminal
TOTAL FOR ITEM 3.2 0.00
3.3 Milestone Category as per Sch. "C" Para. 6.3.2
3.3.1 Complete all tie-ins including all hot taps.
3.3.2 PMCC - Treated Gas Pipeline Completion
3.3.3 PMCC - Condensate Gas Pipeline Completion
3.3.4 Complete Construction of Road Crossings as identified in Drawing PA-SAA001-001
3.3.5 PMCC - Communication, Electrical, Instrumentation & Security systems
3.3.6 PMCC - Surge Relief Skids Package
3.3.7 PMCC - AH Crude Oil Pipeline
3.3.8 Final Mechanical Completion Certificate
TOTAL FOR ITEM 3.3 0.00
SITE DE-MOBILIZATION & COMPLETION (Minimum of 3% OF CONSTRUCTION PRICE)
3.4
Milestone Category as per Sch. "C" Para. 6.3.2
3.4.1 Completion of all PMCC "NO" Exception Items
3.4.2 Completion of all PAC Exception Items
3.4.3 Site Demobilization and Clean-Up.

Saudi Aramco: Confidential


#
Saudi Aramco: Confidential 2
Item
COMPENSATION FOR CHANGES
WORK UNIT RATES

Item
1.0

1.1

1.1.2

1.2

1.2.1
1.2.2
1.2.3

1.3

1.3.1

# Saudi Aramco: Confidential


1.4

1.4.1
1.4.2
1.4.3
1.4.4
1.4.5
1.4.6
1.4.7
1.4.8
1.4.9

1.4.10

1.5

1.5.1
1.5.2
1.5.3
1.5.4

1.6

1.7

1.7.1
1.7.2
1.7.3
1.7.4
1.7.5

1.8

1.8.1
1.8.2

# Saudi Aramco: Confidential


1.9

1.9.1
1.9.2

1.9.3

1.9.4

1.10

1.10.1
1.10.2
1.10.3

1.11

1.11.1
1.11.2
1.11.3

1.12

1.12.1
1.12.2
1.12.3

1.13

1.13.1
1.13.2

1.14

# Saudi Aramco: Confidential


1.14.1
1.14.2

1.15

1.15.1
1.16
1.16.1

1.16.2

1.16.3

1.16.4

1.16.5

1.17
1.18
1.19
1.20

# Saudi Aramco: Confidential


3

3.1

3.1.1

3.1.2

3.1.3

3.1.4

3.2

3.2.1

3.2.2

3.2.3

3.3

# Saudi Aramco: Confidential


3.3.1

3.3.2

3.3.3

3.3.4

3.3.5

3.3.6

3.3.7

3.4

3.4.1

3.5
3.5.1
3.5.2
3.5.3
3.5.4
3.5.5
3.5.6
3.5.7
3.5.8
3.5.9
3.5.10
3.5.11
3.5.12
3.6
3.6.1
3.6.2

3.6.3

3.6.4

3.6.5

3.6.6

# Saudi Aramco: Confidential


3.6.7

3.6.8

3.7

3.7.1

3.8
3.8.1
3.8.2
3.8.3
3.9
3.9.1
3.9.2
3.10

3.10.1

3.10.2

3.10.3

3.10.4

3.10.5

3.10.6

3.10.7

3.10.8

3.10.9

# Saudi Aramco: Confidential


3.11

3.11.1

3.12

3.12.1

3.12.2

3.12.3

3.12.4

3.12.5

3.12.6

3.12.7

3.13

3.13.1

3.13.2

3.14

3.14.1

3.14.2

# Saudi Aramco: Confidential


3.15

3.15.1

3.16

3.16.1

3.16.2

3.17

3.17.1

3.17.2

3.17.3

3.17.4

3.17.5

3.18

3.18.1

3.19

3.19.1

3.20

3.20.1

3.20.2

# Saudi Aramco: Confidential


3.20.3

3.21

3.21.1

3.21.2

3.21.3

3.22

3.22.1

3.23

3.23.1

3.24

3.24.1

3.25

3.25.1

3.25.2

3.25.3

3.25.4

3.25.5

3.25.6

# Saudi Aramco: Confidential


3.25.7

3.25.8

3.26

3.26.1

3.27

3.27.1

3.28

3.28.1

3.28.2

3.28.3

3.28.4

3.29

3.29.1
3.30
3.30.1

3.30.2

3.30.3

3.31

3.31.1

3.31.2

# Saudi Aramco: Confidential


3.32

3.32.1

3.32.2

3.32.3

3.33
3.33.1
3.33.2
3.34
3.34.1

3.35

3.35.1

3.35.2

3.35.3

3.36

3.36.1

3.36.2

3.36.3

3.36.4
3.37
3.37.1
3.38
3.38.1
3.38.2
3.39

3.39.1

3.39.2

# Saudi Aramco: Confidential


3.39.3

3.40

3.40.1

3.41

3.41.1
3.42
3.42.1
3.42.2
3.43

3.43.1

3.44

3.44.1

3.45

3.45.1

3.46

3.46.1
3.47
3.47.1
3.48
3.48.1

3.48.2
3.49
3.49.1

3.50

3.50.1

# Saudi Aramco: Confidential


3.51

3.51.1

3.51.2

3.51.3
3.52
3.52.1

3.52.2
3.53
3.53.1
3.54
3.54.1

3.54.2
3.55
3.55.1
3.56
3.56.1
3.57
3.57.1
3.58
3.58.1

3.59

3.59.1
5.60
3.60.1
3.61
3.61.2
3.62
3.62.1

3.62.2
3.63

# Saudi Aramco: Confidential


3.63.1
3.64
3.64.1

3.64.2

3.65
3.65.1
3.66

3.66.1
3.67
3.67.1

3.68

3.68.1

3.68.2

3.68.3
3.69
3.69.1
3.70
3.70.1
3.71
3.71.1

3.71.2
3.72
3.72.1

3.72.2

3.73

3.73.1

# Saudi Aramco: Confidential


3.73.2

3.74
3.74.1
3.74.2
3.75
3.75.1

3.75.2

3.75.3
3.76
3.76.1

3.76.2

3.76.3
3.77
3.77.1

3.77.2
3.78
3.78.1

3.78.2

3.78.3

3.78.4

3.78.5

3.78.6

3.78.7
3.79
3.79.1
3.80

# Saudi Aramco: Confidential


3.80.1
3.81
3.81.1

3.81.2

3.81.3

3.82

3.82.1

3.82.2
3.83
3.83.1
3.84
3.84.1

3.84.2

3.84.3

3.85

3.85.1

3.85.2

3.85.3

3.85.4

3.85.5

3.85.6

3.86

3.86.1

3.86.2

# Saudi Aramco: Confidential


3.86.3
3.87
3.87.1
3.87.2
3.87.3
3.87.4

3.88

3.88.1
3.88.2
3.89
3.89.1
3.90
3.90.1
3.91
3.91.1
3.92
3.92.1
3.92.2
3.92.3
3.92.4
3.92.5
3.92.6
3.92.7
3.92.8

3.93
3.93.1
3.93.2
3.93.3
3.93.4
3.93.5
3.93.6
3.93.7
3.94
3.94.1
3.94.2
3.94

# Saudi Aramco: Confidential


3.94.1
3.94.2
3.94.3
3.94.4
3.94.5
3.94.6
3.94.7
3.94.8
3.94.9
3.94.10
3.95
3.95.1

3.95.2

3.95.3

3.95.4

3.95.5

3.95.6

3.96
3.96.1
3.96.2

3.96.3

3.97
3.97.1

3.97.2

3.97.3

3.98

# Saudi Aramco: Confidential


3.98.1

3.99
3.99.1

3.99.2

3.99.3

3.99.4

3.99.5

3.99.6

3.99.7

3.99.8

3.99.9

3.99.10

3.99.11

3.99.12

3.99.13

3.99.14

3.99.15

3.99.16

3.99.17

3.99.18

# Saudi Aramco: Confidential


3.99.19

3.99.20

3.99.21

3.99.22

3.99.23

3.99.24

3.99.25

3.99.26

3.99.27

3.99.28

3.99.29

3.99.30

3.99.31

3.99.32

3.100

3.100.1
3.100.2
3.100.3
3.100.4

# Saudi Aramco: Confidential


3.100.5
3.100.6
3.100.7
3.100.8
3.100.9
3.100.10
3.100.11
3.100.12
3.100.13
3.100.14
3.100.15
3.10

3.101.1

3.101.2

3.101.3

3.101.4

3.101.5

3.101.6

# Saudi Aramco: Confidential


3.101.7

3.101.8

3.101.9

3.101.10

3.101.11

3.101.12

3.101.13

3.101.14

3.101.15

3.101.16

3.101.17

3.101.18

# Saudi Aramco: Confidential


3.101.19

3.101.20

3.101.21

3.101.22

3.101.23

3.101.24

3.102

3.102.1

# Saudi Aramco: Confidential


3.102.2

3.102.3

4.00

4.1

4.1.1
4.1.2
4.1.3
4.1.4

4.1.5

4.1.6
4.1.7
4.1.8

4.2

# Saudi Aramco: Confidential


4.2.1
4.2.2

4.3

4.3.1
4.3.2

4.4

4.4.1
4.4.2
4.4.3

4.5

4.5.1

4.6

# Saudi Aramco: Confidential


4.7

4.7.1
4.7.2

4.8

4.8.1

4.9

4.9.1

4.9.2

4.10

4.10.1
4.11
4.11.1

4.11.2

4.11.3
4.11.4

4.12
4.12.1

# Saudi Aramco: Confidential


4.12.2

4.12.3

5.0

5.1

5.1.1
5.1.2
5.1.3

5.1.4

5.1.5
5.1.6
5.1.7
5.1.8
5.1.9

5.1.10

5.1.11

5.1.12

5.1.13

5.1.14

5.1.15

5.1.16

5.1.17

# Saudi Aramco: Confidential


5.1.18

5.1.19

5.1.20

5.1.21

5.1.22

5.1.23
5.1.24
5.1.25
5.2
5.2.1
5.2.2
5.2.3
5.2.4
5.2.5
5.2.6
5.2.7
5.2.8
5.2.9
5.2.10
5.3
5.3.1
5.3.2
5.3.3
5.3.4
5.3.5
5.3.6
5.3.7
5.3.8
5.3.9
5.3.10
5.3.11
5.3.12
5.3.13
5.3.14
5.3.15
5.3.16
5.3.17
5.3.18

# Saudi Aramco: Confidential


5.3.19
5.3.20
5.3.21
5.3.22
5.3.23
5.3.24
5.3.25
5.3.26
5.3.27
5.3.28
5.3.29
5.3.30
5.3.31
5.3.32
5.3.33
5.3.34
5.3.35
5.3.36
5.3.37
5.3.38
5.3.39
5.3.40
5.3.41
5.3.42
5.3.43
5.3.44
5.3.45
5.3.46
5.3.47
5.3.48
5.3.49
5.3.50
5.3.51
5.3.52

5.4

5.4.1

# Saudi Aramco: Confidential


5.4.2

5.5
5.5.1
5.5.2
5.5.3
5.5.4
5.5.5
5.5.6
5.5.7
5.5.8
5.5.9
5.5.10
5.5.11
5.6
5.6.1
5.6.2
5.6.3
5.6.4
5.7
5.7.1
5.7.2
5.7.3
5.7.4
5.7.5
5.7.6
5.7.7
5.7.8
5.7.9
5.7.10
5.7.11
5.7.12
5.7.13
5.7.14
5.7.15

# Saudi Aramco: Confidential


5.7.16
5.7.17
5.7.18

5.8

5.8.1

5.8.2

5.8.5

5.8.6

5.8.7

5.8.4

5.8.4.1

5.8.4.2

5.8.4.3

5.8.4.4

5.8.4.5

5.8.4.6

# Saudi Aramco: Confidential


5.8.4.7

5.8.4.8

5.8.4.9

5.8.4.10
5.8.4.11

5.8.4.12

5.8.4.13

5.8.4.14

5.8.4.15

5.8.4.16

5.8.4.17

5.8.4.18

5.8.4.19

5.8.4.20

5.8.4.21

5.8.4.22

# Saudi Aramco: Confidential


5.8.4.23
5.8.4.24

5.8.4.25

5.8.4.26

5.8.4.27
5.8.4.28
6.0
6.1
6.1.1
6.1.2
6.1.3
6.1.4
6.1.5
6.1.6
6.1.7

6.1.8

6.2
6.2.1
6.2.2
6.2.3
6.2.4
6.2.5
6.2.6
6.2.7
6.3
6.3.1
6.3.2
6.3.3
6.3.4
6.3.5
6.3.6
6.3.7
6.3.8
6.4
6.4.1

# Saudi Aramco: Confidential


6.4.2
6.4.3
6.4.4
6.4.5
6.4.6
6.4.7
6.4.8
6.5
6.5.1
6.6
6.6.1
6.6.2
6.6.3
6.6.4
6.6.6

6.6.7

6.6.8
6.7
6.7.1
6.7.2
6.7.3
6.7.4
6.7.5
6.7.6

6.7.7
6.7.8
6.7.9
6.7.10
6.7.11

6.7.12
6.7.13
6.7.14
6.7.15
6.7.16
6.7.17
6.7.18

# Saudi Aramco: Confidential


6.7.19
6.7.20
6.7.21
6.8
6.8.1
6.8.2
6.8.3
6.8.4
6.8.5
6.8.6
6.8.7
6.9
6.9.1
6.9.2
6.9.3
6.9.4
6.9.5
6.9.6
6.9.7
6.9.8
6.9.9
6.9.10
6.9.11
6.9.12
6.9.13
6.9.14
6.9.15
6.9.16
6.9.17
6.9.18
6.9.19
6.9.20
6.9.21
6.9.22
6.9.23
6.9.24
6.10
6.10.1
6.10.2
6.10.3
6.10.4
6.10.5
6.10.6

# Saudi Aramco: Confidential


6.10.7
6.10.8
6.10.9
Almulhim, Khalid Y:
8 The of this item and
beneathe it should be
8.1 "7" in order to ensure
consistency.
8.2

8.3

8.4

8.5
8.6
8.7

8.8

8.9
8.10
8.11
8.12

8.13
8.14

# Saudi Aramco: Confidential


Description
COMPENSATION FOR CHANGES
WORK UNIT RATES
Description
Linear Meter
Square Meter
Cubic Meter
Metric Ton
Kilogram
System
Kit
Can
Lot
Liter
Piece
Pack
Pair
Roll
Each

Saudi Aramco standards shall be applied & followed for each line item below and the
contents of each standard are inclusive of all other material required for compliance to
that document.
Description
CIVIL/STRUCTURAL

Non-Rock Excavation
Excavation in non-Rock areas (measured in place) including, but not limited to: shoring,
removal and disposal of excess material to a dump site approved by SAUDI ARAMCO,
dewatering and leveling (measured in place). Rate includes safety signs, barricades,
warning lights and all other safety requirements by Saudi Aramco for excavation work.

Excavation by Machine

Rock Excavation
Excavation in Rock areas (measured in place) including, but not limited to: shoring,
removal and disposal of excess material to a dump site approved by SAUDI ARAMCO,
dewatering and leveling (measured in place). Rate includes safety signs, barricades,
warning lights and all other safety requirements by Saudi Aramco for excavation work.

Excavation by Hand
Excavation by Machine
Excavation by Blasting
Asphalt Excavation
Saw, cut and excavate asphalt using machine to all depths including
hauling to a dump site approved by SAUDI ARAMCO
Excavation by Machine

# Saudi Aramco: Confidential


Backfilling & Compaction
Provide back-filling material from a Saudi Aramco approved source, including cost
of material if any, loading & transporting irrespective of distance from jobsite,
handling, placing, compaction in layers 15 to 30 cm as required regardless of the
method used, and testing.
Sand
Marl
Aggregate
ALFGRID G30-301
T-30 APPLICATION
SUPPLY AND APPLICATION OF T-30 ON BERM
SOIL IMPROVEMENT
DYNAMIC REPLACEMENT
GRADED GRANULAR FILL

Supply and install grouting including, but not limited to, formwork, finishing and curing.
Supply and install concrete paving including but not limited to: reinforcing, 150mm
concrete, compaction, leveling and testing.

Reinforced Concrete
Provide Concrete, 6000 psi, reinforced complete in place, ready mixed or site mixed
as required including excavation, form work, steel reinforcement, and plastic
sheeting, and final coating etc.
Reinforced slab on grade or sidewalk (100-150 mm thk.)
Concrete dike, Manhole/Sumps, valve box, etc.
Small Foundations, supports & grade beams
Equipment, pipe rack, and building foundations including pads, footings, and grade
beams.
Provide Concrete, 5000 psi, precast concrete including excavation, form work, steel
reinforcement, and plastic sheeting, and final coating etc.
Asphalt Paving:
Provide & install asphalt paving including, but not limited to, applying prime coat,
tack coat, 200 mm asphalt course, 230 mm type A base course, compaction,
leveling, and testing
Sub-base course (200thk.) as per aramco standard SAES-Q-006
Base course (230thk.) as per aramco standard SAES-Q-006
Asphalt binder course including prime coat (70mm thk.)
Asphalt wearing course including tack coat (50mm thk.)
15 cm asphalt binder course
Grouting
Provide & install grouting including, but not limited to, formwork, finishing and
curing.
Cement Grout
Epoxy Grout

# Saudi Aramco: Confidential


Excavation and removal of existing concrete & asphalt:
Saw cut, Excavation and Removal of existing concrete foundations, slabs, asphalt
paving's or underground duct banks including transportation to Saudi Aramco
approved dump site within 100 Km of the work site.
Remove by hand: reinforced concrete slab
Remove by machine: reinforced concrete slab
Provide trench for cable or conduit. Includes but is not limited to hand excavation,
removing spoils from site, providing 150mm sand bed, compacting, backfilling, and
installing red tiles and warning tape. Does not include installing cable or conduit, cable
route markers, or asphalt paving.

Supply and install concrete paving including but not limited to constructing 230mm
aggregate base course, reinforcing, 150mm concrete, compaction, leveling and testing.

Provide and Install Fencing


This work shall include, but is not limited to, providing all fencing materials and
accessories then installation complete with posts and all appurtenances per As
per SAES-O-201, HCIS SEC-02 CATEGORY-4
SAUDI ARAMCO Type 3 Standard
GATE, DOUBLE GATE, 4850mm WIDE, AS PER STD. DWG. AB-0366679
GATE, WALKGATE, 1200mm WIDE, AS PER STD. DWG. AB-0366679
Provide and Install Fencing
This work shall include, but is not limited to, providing all fencing materials and
accessories then installation complete with posts and all appurtenances per As
per SAES-O-201, FENCE TYPE 1
SAUDI ARAMCO Type 3 Standard
GATE, DOUBLE GATE, 4850mm WIDE, AS PER STD. DWG. AB-0366679
GATE, WALKGATE, 1200mm WIDE, AS PER STD. DWG. AB-0366679

Provide and Install Structural Steel


This work shall include, but is not limited to, providing all materials and
accessories, design, cut, fabricate, weld, drill, ream, grind, transport to site, handle,
erect, bolt, tighten, align, plum, sandblasting, including coating or galvanizing.

Light: Grating, hand rails, ladders, straps, stair treads, rods, plates and structural shapes
less than or equal to 20 pounds per foot. (Galvanized)
Medium: Structural shapes greater than 20 lb./ft. but less than 40 lb./ft. (Galvanized)
Heavy: Structural shapes greater than 40 lb./ft. up to 80 lb./ft. (Galvanized )
Demolition of Structural Steel including cut, dismantle, demolish, load, haul and dispose
of existing structures, supports and platforms to a SAUDI ARAMCO approved disposal
site.
Light weight (less than 20 lb./ft.)
Heavy (over 40 lb./ft. up to 80 lb./ft.)
Shop and Field Applied Coatings
This work shall include, but is not limited to, supply of coating materials, cleaning,
blasting, application, inspection, testing and repairs.

# Saudi Aramco: Confidential


Complete External Field Applied Coating compliant with SA standards for the application.
Including primer, tape wrapping and or paint.
Concrete coating, internally
Scaffolding
Provide, erect and dismantle scaffolding in accordance with Saudi Aramco
Construction Safety Manual (Per Day)
Up to 5 meters high
Reinforcement
REINFORCING STEEL BAR, FUSION BONDED EPOXY COATED,
422 Mpa (60,000psi), 10MM Ø, 0.616 KG/M
REINFORCING STEEL BAR, FUSION BONDED EPOXY COATED,
422 Mpa (60,000psi), 12MM Ø, 0.888 KG/M
REINFORCING STEEL BAR, FUSION BONDED EPOXY COATED,
422 Mpa (60,000psi), 16MM Ø, 1.578 KG/M
REINFORCING STEEL BAR, FUSION BONDED EPOXY COATED,
422 Mpa (60,000psi), 20MM Ø, 2.466 KG/M
COL REINFORCING STEEL BAR, FUSION BONDED EPOXY COATED,
422 Mpa (60,000psi), 25MM Ø, 3.982 KG/M
HDPE LINER
42 INCH PIPE SLEEVE
18 INCH PIPE SLEEVE
10 INCH PIPE SLEEVE
Demolishing Fencing
This work shall include, but is not limited to,demolish all fencing materials and
accessories with posts and all appurtenances per As per SAES-O-201, FENCE
TYPE 1

# Saudi Aramco: Confidential


PIPING WORK
The WORK Unit Rates are inclusive of, but not limited to, allowance for supply of all
necessary permanent and consumable materials and the following:
(a) All office and field engineering work associated with pipework and all fitting,
other than valves, including checking of dimensions and clearances.
(b) All pipework joints shall include cutting the pipe to length, end preparation for
weld connections, cleaning, leveling, alignment and set up, welding and all labor
and consumables necessary to complete making the joint.
(c) All required testing and examinations including, but not limited to, radiography,
ultrasonic testing, magnetic particle imaging, liquid penetration, external coating,
stress relieving and hydrostatic testing.
d) Above ground on supports. Price to cover supply and installation of pipe and all
fittings, other than valves, with associated bolting, clamping or other direct fixing to
the structure and pipe supports or hangers, sleeves, guides and anchors, as
required. Price also includes, but is not limited to, associated handling, setting in
place, sleeving, guides, anchors, blocking, vapor seals and all connecting
hardware.
Supply, install, test and Paint/Coat above ground piping (In-Plant), including but not
limited to surveying, bending, cutting, beveling, welding, high point vents, low point
drains, tie-ins, transportation, lifting, holding in place and scaffolding.
NPS

Under Ground ; Pipe Metallic, Carbon Steel, Bare, Beveled, Externally FBE
Coated.SAML/LSAW; API 5L GR X65
PIPE 42"; LSAW; ASME B36.10M; BE; XS WT; CS API 5L GR X65 Externally FBE
Coated 09-SAMSS-089
PIPE 42"; LSAW; ASME B36.10M; BE; 0.625" WT; CS API 5L GR X65 Externally FBE
Coated 09-SAMSS-089
PIPE 42"; LSAW; ASME B36.10M; BE; 0.688" WT; CS API 5L GR X65 Externally FBE
Coated 09-SAMSS-089
PIPE 32"; LSAW; ASME B36.10M; BE; 0.500" WT; CS API 5L GR X65 Externally FBE
Coated 09-SAMSS-089
Under Ground ; Pipe Metallic, Caebon Steel, Bare, Beveled, Internally & Externally
FBE Coated.SAML/LSAW; API 5L GR X65
PIPE 18"; SMLS; ASME B36.10M; BE; 0.250" WT; CS API 5L GR X65 Internally &
Externally FBE Coated 09-SAMSS-091 & 09-SAMSS-089
PIPE 18"; SMLS; ASME B36.10M; BE; 0.281" WT; CS API 5L GR X65 Internally &
Externally FBE Coated 09-SAMSS-091 & 09-SAMSS-089
PIPE 18"; SMLS; ASME B36.10M; BE; 0.312" WT; CS API 5L GR X65 Internally &
Externally FBE Coated 09-SAMSS-091 & 09-SAMSS-089
Above Ground ; Pipe Metallic, Caebon Steel, Bare, Beveled, Internally FBE
Coated.SAML/LSAW; API 5L GR X65

# Saudi Aramco: Confidential


PIPE 18"; SMLS; ASME B36.10M; BE; 0.312" WT; CS API 5L GR X65 FBE LINED PER
09-SAMSS-091
PIPE 16"; SMLS; ASME B36.10M; BE; STD WT; CS API 5L GR X65 FBE LINED PER 09-
SAMSS-091
PIPE 30"; LSAW ASME B36.10M; BE; XS WT; CS API 5L GR X65 FBE LINED PER 09-
SAMSS-091
PIPE 30"; LSAW ASME B36.10M; BE; 0.562" WT; CS API 5L GR X65 FBE LINED PER
09-SAMSS-091
PIPE 32"; LSAW ASME B36.10M; BE; 0.500" WT; CS API 5L GR X65 FBE LINED PER
09-SAMSS-091
PIPE 42"; LSAW ; ASME B36.10M; BE; STD WT; CS API 5L GR X65 FBE LINED PER
09-SAMSS-091
PIPE 42";LSAW ; ASME B36.10M; BE; 0.750" WT; CS API 5L GR X65 FBE LINED PER
09-SAMSS-091
Under Ground ; Pipe Metallic, Caebon Steel, Bare, Beveled, Internally & Externally
FBE Coated.SAML/LSAW; API 5L GR X60
PIPE 10"; SMLS; ASME B36.10M; BE; 0.250" WT; CS API 5L GR X60 Internally &
Externally FBE Coated 09-SAMSS-091 & 09-SAMSS-089
Above Ground; Pipe, Metallic, Carbon Steel, Bare, Beveled, Internally FBE
coated.SMLS/LSAW; BE; API 5L GR X60
PIPE 8"; XS WT FBE LINED PER 09-SAMSS-091
PIPE 10";0.250" WT FBE LINED PER 09-SAMSS-091
PIPE 10";0.279" WT FBE LINED PER 09-SAMSS-091
PIPE 10";0.365" WT FBE LINED PER 09-SAMSS-091
PIPE 12"; 0.406" WT FBE LINED PER 09-SAMSS-091
PIPE 16"; STD WT FBE LINED PER 09-SAMSS-091
PIPE 36"; 0.375" WT FBE LINED PER 09-SAMSS-091
PIPE 36"; 0.500" WT FBE LINED PER 09-SAMSS-091
PIPE 40"; 0.375" WT FBE LINED PER 09-SAMSS-091
PIPE 42"; 0.375" WT FBE LINED PER 09-SAMSS-091
PIPE 42"; 0.562" WT FBE LINED PER 09-SAMSS-091
PIPE 48";0.375" WT FBE LINED PER 09-SAMSS-091
Above Ground; PIPE; SMLS/LSAW; ASME B36.10M; BE; CS API 5L GR B FBE
LINED
PIPE 1"; SMLS; ASME B36.10M; PL END; XS; CS ASTM A106 GR B
PIPE 2"; SMLS; ASME B36.10M; BE; XS WT; CS API 5L GR B FBE LINED PER 09-
SAMSS-091
PIPE 3"; SMLS; ASME B36.10M; BE; STD WT; CS API 5L GR B FBE LINED PER 09-
SAMSS-091
PIPE 4"; SMLS; ASME B36.10M; BE; STD WT; CS API 5L GR B FBE LINED PER 09-
SAMSS-091
PIPE 4"; SMLS; ASME B36.10M; BE; XS WT; CS API 5L GR B FBE LINED PER 09-
SAMSS-091
PIPE 6"; SMLS; ASME B36.10M; BE; STD WT; CS API 5L GR B FBE LINED PER 09-
SAMSS-091

# Saudi Aramco: Confidential


PIPE 6"; SMLS; ASME B36.10M; BE; XS WT; CS API 5L GR B FBE LINED PER 09-
SAMSS-091
PIPE 10"; SMLS; ASME B36.10M; BE; STD WT, API 5L GR B; PSL2; FBE LINED PER
09-SAMSS-091
PIPE 2" ; Metallic, Carbon Steel, Galvanized, threaded and coupled. SMLS; MNPT;
XS; CS
PIPE 4", SCH.40, SEAMLESS, NPT(M), ASTM A106 GR.B (GALVANIZED), ASME
B36.10
NON-METALLIC HDPE (HIGH-DENSITY POLYETHYLENE), PER 01-SAMSS-051 (ISO
4427), DESIGN PRESSURE:150 PSIG, DESIGN TEMP. 120F
PIPE, NON-METALLIC: 16" NPS HDPE
PIPE, NON-METALLIC: 8" NPS HDPE
PIPE, NON-METALLIC: 4" NPS HDPE
NON-METALLIC RTR (EPOXY RESIN), LAMINATION JOINT, DESIGN PRESSURE 200
PSIG 01-SAMSS‐034.
PIPE, NON-METALLIC: 2" NPS, RTR (EPOXY RESIN)
PIPE, NON-METALLIC: 16" NPS, RTR (EPOXY RESIN)
BALL VALVE; BODY: A216 WCB ; including gaskets and bolting; CL 600
VALVE: BALL, 8", CL 600, RF FLANGED PER ASME B16.5, A216 WCB WITH
INTERNALLY EPOXY LINED BODY, SS 410 TRIM, TRUNNION MOUNTED, SIDE
ENTRY, FULL BORE, ELECTRIC MOTOR OPERATED, FIRE SAFE, API 6D
VALVE: BALL, 10", CL 600, RF FLANGED PER ASME B16.5, A216 WCB WITH
INTERNALLY EPOXY LINED BODY, A182 F51 TRIM, TRUNNION MOUNTED, SIDE
ENTRY, FULL BORE, ELECTRIC MOTOR OPERATED, FIRE SAFE, API 6D
VALVE: BALL, 10", CL 600, RF FLANGED PER ASME B16.5, A216 WCB WITH
INTERNALLY EPOXY LINED BODY, SS 410 TRIM, TRUNNION MOUNTED, SIDE
ENTRY, FULL BORE, ELECTRIC MOTOR OPERATED, FIRE SAFE, API 6D
VALVE: BALL, 16", CL 600, RF FLANGED PER ASME B16.5, A216 WCB BODY WITH
INTERNAL FBE COATING, SS 410 TRIM, TRUNNION MOUNTED, SIDE ENTRY, FULL
BORE, ELECTRIC MOTOR OPERATED, FIRE SAFE, API 6D
VALVE: BALL, 16", CL 600, RF FLANGED PER ASME B16.5, A216 WCB WITH
INTERNALLY EPOXY LINED BODY, SS 410 TRIM, TRUNNION MOUNTED, SIDE
ENTRY, FULL BORE, ELECTRIC MOTOR OPERATED, FIRE SAFE, API 6D
VALVE: BALL, 18", CL 600, RF FLANGED PER ASME B16.5, A216 WCB BODY WITH
INTERNAL FBE COATING, SS F51 TRIM, TRUNNION MOUNTED, SIDE ENTRY, FULL
BORE, ELECTRIC MOTOR OPERATED, FIRE SAFE, API 6D
VALVE: BALL, 30", CL 600, RF FLANGED PER ASME B16.47A, A216 WCB WITH
INTERNALLY EPOXY LINED BODY, SS 410 TRIM, TRUNNION MOUNTED, SIDE
ENTRY, FULL BORE, ELECTRIC MOTOR OPERATED, FIRE SAFE, API 6D
VALVE: BALL, 42", CL 600, RF FLANGED PER ASME B16.47A, A216 WCB BODY, SS
F51 TRIM, TRUNNION MOUNTED, SIDE ENTRY, FULL BORE, PNEUMATIC
OPERATED, FIRE SAFE, API 6D
VALVE: BALL, 42", CL 600, RF FLANGED PER ASME B16.47A, A216 WCB BODY, SS
410 TRIM, TRUNNION MOUNTED, SIDE ENTRY, FULL BORE, ELECTRIC MOTOR
OPERATED, FIRE SAFE, API 6D

# Saudi Aramco: Confidential


BALL VALVE; BODY: A351 CF8M ; including gaskets and bolting; CL 600
VALVE: BALL, 2", CL 600, RF FLANGED PER ASME B16.5, A351 CF8M BODY, TRIM
12, TRUNNION SUPPORTED , FULL BORE, LIMIT SWITCH , FIRE SAFE, API 6D

BALL VALVE; BODY: BODY: ASTM A216 WCB; including gaskets and bolting; CL
300 / CL 150
VALVE: BALL, 48", CL 300, RF FLANGED PER ASME B16.47A, A216 WCB WITH
INTERNALLY EPOXY LINED BODY, SS 410 TRIM, TRUNNION MOUNTED, SIDE
ENTRY, FULL BORE, ELECTRIC MOTOR OPERATED , FIRE SAFE, API 6D, PER 04-
SAMSS-051
VALVE: BALL, 40", CL 300, RF FLANGED PER ASME B16.47A, A216 WCB WITH
INTERNALLY EPOXY LINED BODY, SS 410 TRIM, TRUNNION MOUNTED, SIDE
ENTRY, FULL BORE, ELECTRIC MOTOR OPERATED , FIRE SAFE, API 6D, PER 04-
SAMSS-051
VALVE: BALL, 40", CL 300, RF FLANGED PER ASME B16.47A, A216 WCB WITH
INTERNALLY EPOXY LINED BODY, SS 410 TRIM, TRUNNION MOUNTED, SIDE
ENTRY, FULL BORE, ELECTRIC MOTOR OPERATED, FIRE SAFE, API 6D, PER 04-
SAMSS-051
VALVE: BALL, 30", CL 300, RF FLANGED PER ASME B16.47A, A216 WCB BODY, SS
410 TRIM, TRUNNION MOUNTED, SIDE ENTRY, FULL BORE, ELECTRIC MOTOR
OPERATED , FIRE SAFE, API 6D, PER 04-SAMSS-051.
VALVE: BALL, 32", CL 300, RF FLANGED PER ASME B16.47A, A216 WCB BODY, SS
410 TRIM, TRUNNION MOUNTED, SIDE ENTRY, FULL BORE, ELECTRIC MOTOR
OPERATED , FIRE SAFE, API 6D, PER 04-SAMSS-051.
VALVE: BALL, 36", CL 300, RF FLANGED PER ASME B16.47A, A216 WCB BODY, SS
410 TRIM, TRUNNION MOUNTED, SIDE ENTRY, FULL BORE, ELECTRIC MOTOR
OPERATED , FIRE SAFE, API 6D, PER 04-SAMSS-051.
VALVE: BALL, 42", CL 300, RF FLANGED PER ASME B16.47A, A216 WCB WITH
INTERNALLY EPOXY LINED BODY, SS 410 TRIM, TRUNNION MOUNTED, SIDE
ENTRY, FULL BORE, ELECTRIC MOTOR OPERATED , FIRE SAFE, API 6D, PER 04-
SAMSS-051
GATE VALVE ; FLGD RF; HNDWHL OPR, CS BODY ASTM A216; including gaskets
and bolting. CL-600
VALVE: GATE, 2", CL 600, RF FLANGED PER ASME B16.5, A216 WCB BODY, TRIM 8,
HANDWHEEL OPERATED, API 600
VALVE: GATE, 4", CL 600, RF FLANGED PER ASME B16.5, A216 WCB BODY WITH
INTERNAL FBE COATING, SS 410 TRIM, SOLID WEDGE, HANDWHEEL OPERATED,
API 600
GATE VALVE ; FLGD RF; HNDWHL OPR, CS BODY A351 CF8M BODY; including
gaskets and bolting. CL-600
VALVE: GATE, 2", CL 600, RF FLANGED PER ASME B16.5, A351 CF8M BODY, TRIM
12, SOLID WEDGE, HANDWHEEL OPERATED, API 600
VALVE: GATE, 3", CL 600, RF FLANGED PER ASME B16.5, A351 CF8M BODY, TRIM
12, SOLID WEDGE, HANDWHEEL OPERATED, API 600

# Saudi Aramco: Confidential


GATE VALVE ; FLGD RF; HNDWHL OPR, CS BODY A351 CF8M; including gaskets
and bolting. CL-300

VALVE: GATE, 2", CL300, RF FLANGED PER ASME B16.5, A351 CF8M BODY, TRIM
NO. 12, SOLID WEDGE, HANDWHEEL OPERATED, API 600, AS PER 04-SAMSS-001.

GATE VALVE ; FLGD RF; HNDWHL OPR, CS BODY A351 CF8M; including gaskets
and bolting. CL-150
VALVE: GATE, 2", CL150, RF FLANGED PER ASME B16.5, A351 CF8M BODY, TRIM
NO. 12, SOLID WEDGE, HANDWHEEL OPERATED, API 600
VALVE: GATE, 3", CL150, RF FLANGED PER ASME B16.5, A351 CF8M BODY, TRIM
NO. 12, SOLID WEDGE, HANDWHEEL OPERATED, API 600
GATE VALVE ; FLGD RF; HNDWHL OPR, CS BODY ASTM A216; including gaskets
and bolting. CL-150
VALVE: GATE, 2", CL 150, RF FLANGED PER ASME B16.5, A216 WCB BODY, SS 410
TRIM, SOLID WEDGE, HANDWHEEL OPERATED, API 600
VALVE: GATE, 3", CL 150, RF FLANGED PER ASME B16.5, A216 WCB BODY, SS 410
TRIM, SOLID WEDGE, HANDWHEEL OPERATED, API 600
VALVE: GATE, 4", CL150, RF FLANGED PER ASME B16.5, A216 WCB BODY, TRIM
NO. 8 WITH INTERNALLY EPOXY LINED BODY, SOLID WEDGE, HANDWHEEL
OPERATED, API 600
VALVE: GATE, 6", CL150, RF FLANGED PER ASME B16.5, A216 WCB BODY WITH
INTERNALLY EPOXY LINED BODY, TRIM NO. 8, SOLID WEDGE, HANDWHEEL
OPERATED, API 600
VALVE: GATE, 10", CL150, RF FLANGED PER ASME B16.5, A216 WCB BODY WITH
INTERNALLY EPOXY LINED BODY, TRIM NO. 8, SOLID WEDGE, HANDWHEEL
OPERATED, API 600
GATE VALVE 2"; THD NPT; MSS SP 80; BRONZE; HNDWHL OPR; including
gaskets and bolting.
CL 150
VALVE: GATE, 3", CL 150, FNPT, BRONZE (B61/B62) BODY AND TRIM, SOLID
WEDGE, HANDWHEEL (ISRS) OPERATED, MSS SP-80
PLUG VALVE ; FLGD FR; A351 CF8M BODY,HANDWHEEL OPERATED including
gaskets and bolting.CL-600
VALVE, PLUG: 2", CL 600, RF FLANGED PER ASME B16.5, A351 CF8M BODY,
LUBRICATED, INVERTED PRESSURE BALANCED, BC, API 599, TRIM 12,
HANDWHEEL OPERATED
PLUG VALVE ; FLGD FR; A216 WCB BODY,GEAR OPERATED including gaskets
and bolting.CL-600
VALVE, PLUG: 4", CL 600, RF FLANGED PER ASME B16.5, A216 GR. WCB BODY
WITH INTERNAL FBE COATING, LUBRICATED, INVERTED PRESSURE BALANCED,
BC, API 599, TRIM SS F51, GEAR OPERATED
VALVE, PLUG: 4", CL 600, RF FLANGED PER ASME B16.5, A216 GR. WCB BODY
WITH INTERNAL FBE COATING, LUBRICATED, INVERTED PRESSURE BALANCED,
BC, API 599, TRIM SS 410, GEAR OPERATED

# Saudi Aramco: Confidential


VALVE, PLUG: 6", CL 600, RF FLANGED PER ASME B16.5, A216 GR. WCB BODY
WITH INTERNAL FBE COATING, LUBRICATED, INVERTED PRESSURE BALANCED,
BC, API 599, TRIM SS F51 , GEAR OPERATED
PLUG VALVE ; FLGD FR; A216 WCB BODY,ELECTRIC MOTOR OPERATED
including gaskets and bolting.CL-600
VALVE, PLUG: 12", CL 300, RF FLANGED PER ASME B16.5, A216 GR. WCB ,
LUBRICATED, INVERTED PRESSURE BALANCED, BC, API 599, TRIM SS F51,
ELECTRIC MOTOR OPERATED
VALVE, PLUG: 16", CL 600, RF FLANGED PER ASME B16.5, A216 GR. WCB,
LUBRICATED, INVERTED PRESSURE BALANCED, BC, API 599, TRIM SS F51,
ELECTRIC MOTOR OPERATED

VALVE, PLUG: 16", CL 600, RF FLANGED PER ASME B16.5, A216 GR. WCB WITH
INTERNALLY EPOXY LINED BODY, LUBRICATED, INVERTED PRESSURE
BALANCED, BC, API 599, TRIM SS F51, ELECTRIC MOTOR OPERATED

GLOBE VALVE ; FLGD FR; A351 CF8M BODY,HANDWHEEL OPERATED including


gaskets and bolting.CL-600
VALVE: GLOBE, 2", CL 600, RF FLANGED PER ASME B16.5, A351 CF8M BODY, TRIM
NO. 12, HANDWHEEL OPERATED, API 600
GLOBE VALVE ; FLGD FR; A216 WCB BODY,ELECTRIC MOTOR OPERATED
including gaskets and bolting.
CL-600
VALVE: GLOBE, 24", CL 600, RF FLANGED PER ASME B16.47A, A216 WCB
BODY,WITH INTERNAL FBE COATING, SS 410 TRIM, BOLTED BONNET, OS&Y, FULL
BORE, ELECTRIC MOTOR OPERATED , FIRE SAFE, API 6D
CHECK VALVE;SWING TYPE, BODY : A351 CF8M BODY; including gaskets and
bolting; CL 600
VALVE, CHECK: 2", CL 600, RF FLANGED PER ASME B16.5, A351 CF8M BODY, BC,
SWING TYPE, TRIM NO. 12
CHECK VALVE;SWING TYPE, BODY : ASTM A216 WCB WITH INTERNALLY FBE
COATED; including gaskets and bolting; CL 600
VALVE, CHECK: 4", CL 600, RF FLANGED PER ASME B16.5, A216 WCB BODY WITH
INTERNAL FBE COATING, BC, SWING TYPE, TRIM NO. 1
VALVE, CHECK: 6", CL 600, RF FLANGED PER ASME B16.5, A216 WCB BODY WITH
INTERNALLY FBE COATED, BC, SWING TYPE, TRIM NO. 1
VALVE, CHECK: 10", CL 600, RF FLANGED PER ASME B16.5,A216 WCB BODY WITH
INTERNALLY EPOXY LINED BODY, BC, SWING TYPE, TRIM NO. 1
VALVE, CHECK: 16", CL 600, RF FLANGED PER ASME B16.5, A216 WCB BODY WITH
INTERNAL FBE COATING, BC, SWING TYPE, TRIM NO. 1
VALVE, CHECK: 30", CL 600, RF FLANGED PER ASME B16.47A, A216 WCB BODY
WITH INTERNAL FBE COATING, BC, SWING TYPE, TRIM NO. 1

VALVE, CHECK: 30", CL 600, RF FLANGED PER ASME B16.47A, A216 WCB BODY
WITH INTERNAL FBE COATING, NON-SLAM TYPE, SPRING ASSISTED TRIM NO. 1

# Saudi Aramco: Confidential


VALVE, CHECK: 42", CL 600, RF FLANGED PER ASME B16.47A, A216 WCB BODY,
BC, SWING TYPE, TRIM NO. 1
VALVE, CHECK: 42", CL 600, RF FLANGED PER ASME B16.47A, A216 WCB WITH
INTERNALLY EPOXY LINED BODY, BC, SWING TYPE, TRIM NO. 1
CHECK VALVE;SWING TYPE, BODY: NPT, BRONZE B61/B62 BODY; including
gaskets and bolting; CL 150
VALVE, CHECK: 2", CL 150, FNPT, BRONZE B61/B62 BODY AND TRIM, ISRS, BC,
SWING TYPE, MSS SP-80.
CHECK VALVE; NON-SLAM TYPE,BODY: ASTM A216 WCB / ASTM A105N;
including gaskets and bolting; CL 150
VALVE, CHECK: 6", CL 150, RF FLANGED PER ASME B16.5, A216 WCB BODY WITH
INTERNAL FBE COATING, BC, NON-SLAM TYPE, TRIM NO. 1,
CHECK VALVE; SWING TYPE,BODY: ASTM A216 WCB / ASTM A105N; including
gaskets and bolting; CL 150
CHECK VALVE 2",CLASS 150 RF,ASTM A216 WCB / ASTM A105N, TRIM 1, BC, API
594,SWING TYPE

VALVE, CHECK: 4", CL 150, RF FLANGED PER ASME B16.5, A216 WCB BODY WITH
INTERNAL FBE COATING, BC, SWING TYPE, TRIM NO. 1, PER 04-SAMSS-005.

VALVE, CHECK: 6", CL 150, RF FLANGED PER ASME B16.5, A216 WCB BODY WITH
INTERNAL FBE COATING, BC, SWING TYPE, TRIM NO. 1, PER 04-SAMSS-005.

VALVE, CHECK: 36", CL 150, RF FLANGED PER ASME B16.47A, A216 WCB BODY
WITH INTERNAL FBE COATING, BC, SWING TYPE, TRIM NO. 1, PER 04-SAMSS-005.

Pipe Fittings, including handling, transportation, welding and painting; as per 02-
SAMSS-005

45 ELBOW, SCH XS, WELDED, BW, ASTM A234 WPB, INT. FBE LINED, ASME B16.9

45 ELBOW 42”, SCH XS, WELDED, BW, ASTM A234 WPB, INT. FBE LINED, ASME
B16.9
45 ELBOW, STD, WELDED, BW, CS WPHY 60, INT. FBE LINED, AMSS SP-75
45 ELBOW 40", ELBOW WELDED, STD, CS WPHY 60, INT. FBE LINED, AMSS SP-75;
SCH STD
45 ELBOW 42", ELBOW WELDED, STD, CS WPHY 60, INT. FBE LINED, AMSS SP-75;
SCH STD
45 ELBOW 48”, STD, WELDED, BW, CS WPHY 60, INT. FBE LINED, AMSS SP-75;
SCH STD

45 ELBOW, STD, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME B16.9

45 ELBOW 10", ELBOW SEAMLESS, STD, ASTM A234 WPB-WX, INT. FBE LINED,
ASME B16.9; SCH STD
45 ELBOW 3", ELBOW SEAMLESS, STD, ASTM A234 WPB-WX, INT. FBE LINED,
ASME B16.9; SCH STD

# Saudi Aramco: Confidential


90 ELBOW, HDPE (HIGH-DENSITY POLYETHYLENE) PER 01-SAMSS-051 (ISO
4427), DESIGN PRESSURE:150 PSIG, DESIGN TEMP. 120F
ELBOW , 6" NPS, 90 DEG: HDPE (HIGH-DENSITY POLYETHYLENE) PER 01-SAMSS-
051 (ISO 4427), DESIGN PRESSURE:150 PSIG, DESIGN TEMP. 120F
ELBOW , 4" NPS, 90 DEG: HDPE (HIGH-DENSITY POLYETHYLENE) PER 01-SAMSS-
051 (ISO 4427), DESIGN PRESSURE:150 PSIG, DESIGN TEMP. 120F
ELBOW , 8" NPS, 90 DEG: HDPE (HIGH-DENSITY POLYETHYLENE) PER 01-SAMSS-
051 (ISO 4427), DESIGN PRESSURE:150 PSIG, DESIGN TEMP. 120F
ELBOW, NON-METALLIC: RTR (EPOXY RESIN), LAMINATION JOINT, DESIGN
PRESSURE 200 PSIG, 01‐SAMSS‐034.
ELBOW, NON-METALLIC: 2" NPS, RTR (EPOXY RESIN), 90 DEG
ELBOW, NON-METALLIC: 2" NPS, RTR (EPOXY RESIN), 45 DEG
90 ELBOW, CLASS 150 ASME B16.3 malleable iron, galvanized
ELBOW, PIPE: 4", 90 DEG. LR, BW, 0.237" WT, ASME B16.3 malleable iron, galvanized
90 ELBOW, SCH XS, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME
B16.9
90 ELBOW 6”, SCH XS, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME
B16.9; SCH XS
90 ELBOW 4”, SCH XS, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME
B16.9; SCH XS
90 ELBOW 2”, SCH XS, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME
B16.9; SCH XS
90 ELBOW, SCH STD, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME
B16.9
90 ELBOW 10”, SCH STD, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME
B16.9; SCH STD
90 ELBOW 6”, SCH STD, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME
B16.9; SCH STD
90 ELBOW 4”, SCH STD, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME
B16.9; SCH STD
90 ELBOW 3”, SCH STD, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME
B16.9; SCH STD
90 ELBOW, WELDED, ASTM A860 WPHY 60 MSS-SP-75
90 ELBOW 16", WELDED, ASTM A860 WPHY 60, MSS-SP-75, 0.375"WT
90 ELBOW, WELDED, ASTM A860 WPHY 60 MSS-SP-75
90 ELBOW 48", WELDED, ASTM A860 WPHY 60, MSS-SP-75, 0.375"WT
90 ELBOW 42", WELDED, ASTM A860 WPHY 60, MSS-SP-75, 0.375"WT
90 ELBOW, WELDED, ASTM A860 WPHY 60, INT. FBE LINED, MSS-SP-75 ; SCH STD

90 ELBOW 40", WELDED, ASTM A860 WPHY 60, INT. FBE LINED, MSS-SP-75 ; SCH
STD
90 ELBOW 42", WELDED, ASTM A860 WPHY 60, INT. FBE LINED, MSS-SP-75 ; SCH
STD

# Saudi Aramco: Confidential


90 ELBOW 48", WELDED, ASTM A860 WPHY 60, INT. FBE LINED, MSS-SP-75 ; SCH
STD
90 ELBOW, SEAMLESS, ASTM A860 WPHY 60, INT. FBE LINED, MSS-SP-75 ; SCH
XS
90 ELBOW 8", SEAMLESS, ASTM A860 WPHY 60, INT. FBE LINED, MSS-SP-75 ; SCH
XS
90 ELBOW, SEAMLESS, ASTM A860 WPHY 60, INT. FBE LINED, MSS-SP-75 ; 0.279
WT
90 ELBOW 10", SEAMLESS, ASTM A860 WPHY 60, INT. FBE LINED, MSS-SP-75 ;
0.279 WT
90 ELBOW, WELDED, ASTM A860 WPHY 65, MSS-SP-75
90 ELBOW 42", WELDED, ASTM A860 WPHY 65, MSS-SP-75, 0.750"WT
90 ELBOW 32", WELDED, ASTM A860 WPHY 65, MSS-SP-75, 0.500"WT
90 ELBOW, WELDED, ASTM A860 WPHY 65, INT. FBE LINED, MSS-SP-75 ; 0.750"
WT
90 ELBOW 42", WELDED, ASTM A860 WPHY 65, INT. FBE LINED, MSS-SP-75 ; SCH
0.750” WT
90 ELBOW, WELDED, ASTM A860 WPHY 65, INT. FBE LINED, MSS-SP-75 ; 0.562"
WT
90 ELBOW 30", WELDED, ASTM A860 WPHY 65, INT. FBE LINED, MSS-SP-75 ; SCH
0.562” WT

90 ELBOW, WELDED, ASTM A860 WPHY 65, INT. FBE LINED, MSS-SP-75 ; XS WT

90 ELBOW 30", WELDED, ASTM A860 WPHY 65, INT. FBE LINED, MSS-SP-75 ; SCH
XSWT

90 ELBOW, WELDED, ASTM A860 WPHY 65, INT. FBE LINED, MSS-SP-75 ; STD WT

90 ELBOW 16", WELDED, ASTM A860 WPHY 65, INT. FBE LINED, MSS-SP-75 ; SCH
XSWT
ECCENTRIC REDUCER, ASTM A860 WPHY 60, INT. FBE LINED
ECCENTRIC REDUCER, ASTM A860 WPHY 60, INT. FBE LINED, MSS-SP-75 ; SIZE:
42" X 36",0.375"X0.312", INT. FBE LINED
ECCENTRIC REDUCER, ASTM A860 WPHY 65, INT. FBE LINED
ECCENTRIC REDUCER, ASTM A860 WPHY 65, INT. FBE LINED, MSS-SP-75 ; SIZE:
42" X 36",0.750"X0.562", INT. FBE LINED
ECCENTRIC REDUCER, ASTM A860 WPHY 65, INT. FBE LINED, MSS-SP-75 ; SIZE:
30" X 24",0.562"X0.500", INT. FBE LINED
ECCENTRIC REDUCER, SEAMLESS, SCH XS, ASTM A234, ASM B16.9
CONCENTRIC REDUCER SEAMLESS, ASTM A234 WPB-WX, ASME B16.9; SCH XS;
SIZE: 3" X 2"
ECCENTRIC REDUCER, SEAMLESS, SCH XS, ASTM A234, ASM B16.9 WITH
INTERNALLY FBE COATED
ECCENTRIC REDUCER SEAMLESS, ASTM A234 WPB-WX, ASME B16.9; SCH XS;
SIZE: 4" X 6",INTERNALLY FBE COATED

# Saudi Aramco: Confidential


ECCENTRIC REDUCER, SEAMLESS, SCH STD, ASTM A234, ASM B16.9 WITH
INTERNALLY
ECCENTRIC REDUCER SEAMLESS, ASTM A234 WPB-WX, ASME B16.9; SCH STD
SIZE: 10" X 4",INTERNALLY FBE COATED
ECCENTRIC REDUCER SEAMLESS, ASTM A234 WPB-WX, ASME B16.9; SCH STD
SIZE: 6" X 4",INTERNALLY FBE COATED
ECCENTRIC REDUCER SEAMLESS, ASTM A234 WPB-WX, ASME B16.9; SCH STD
SIZE: 3" X 2",INTERNALLY FBE COATED
EQUAL TEE, SEAMLESS, BW, SCH STD, ASTM A234 WPB, INT. FBE LINED
EQUAL TEE 3”, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME B16.9;
SCH STD
EQUAL TEE 4”, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME B16.9;
SCH STD
EQUAL TEE,ASTM A860 WPHY 65
EQUAL TEE , 42",0.750" WT, ASTM A860 WPHY 65,STD WTMSS-SP-75
EQUAL TEE,BARRED ASTM A860 WPHY 65
EQUAL TEE BARRED, 42", 0.688"X0.750" WT, ASTM A860 WPHY 65,STD WTMSS-
SP-75
EQUAL TEE BARRED, 32", 0.500" WT, ASTM A860 WPHY 65,STD WTMSS-SP-75
EQUAL TEE,BARRED, ASTM A860 WPHY 66 INT. FBE LINED
EQUAL TEE BARRED, 10",BARRED, 0.250"X0.279" WT, ASTM A860 WPHY 65,STD
WTMSS-SP-75
EQUAL TEE, SCH STD, ASTM A860 WPHY 65 INT. FBE LINED
EQUAL TEE 16", ASTM A860 WPHY 65,STD WT, INT. FBE LINED, MSS-SP-75
EQUAL TEE, SCH XS, ASTM A860 WPHY 65 INT. FBE LINED
EQUAL TEE 30", ASTM A860 WPHY 65,XS WT, INT. FBE LINED, MSS-SP-75
EQUAL TEE, 0.312" WT, ASTM A860 WPHY 60 INT. FBE LINED
EQUAL TEE 36", 0.312" WT, ASTM A860 WPHY 60,0.279" WT, INT. FBE LINED, MSS-
SP-75

EQUAL TEE,BARRED, 0.250"X0.279" WT, ASTM A860 WPHY 60 INT. FBE LINED

EQUAL TEE 10",BARRED, 0.250"X0.279" WT, ASTM A860 WPHY 60,0.279" WT, INT.
FBE LINED, MSS-SP-75
EQUAL TEE, 0.279" WT, ASTM A860 WPHY 60 INT. FBE LINED
EQUAL TEE 10", ASTM A860 WPHY 60,0.279" WT, INT. FBE LINED, MSS-SP-75
EQUAL TEE, SCH STD, ASTM A860 WPHY 60 INT. FBE LINED
EQUAL TEE 42", ASTM A860 WPHY 60, INT. FBE LINED, MSS-SP-75
EQUAL TEE, SEAMLESS, BW, SCH 40, ASTM A234 WPB, INT. FBE LINED
EQUAL TEE 6”, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME B16.9;
SCH 40
EQUAL TEE 10”, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME B16.9;
SCH 40
EQUAL TEE, SEAMLESS, BW, SCH 80, ASTM A234 WPB

# Saudi Aramco: Confidential


EQUAL TEE 4”, SEAMLESS, BW, ASTM A234 WPB, ASME B16.9; SCH 80
EQUAL TEE, SEAMLESS, BW, SCH 80, ASTM A234 WPB, INT. FBE LINED
EQUAL TEE 2”, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME B16.9;
SCH 80
EQUAL TEE 4”, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME B16.9;
SCH 80
TEE: EQUAL HDPE (HIGH-DENSITY POLYETHYLENE) PER 01-SAMSS-051 (ISO
4427), DESIGN PRESSURE:150 PSIG, DESIGN TEMP. 120F
TEE: EQUAL, 16", HDPE (HIGH-DENSITY POLYETHYLENE)
REDUCING TEE, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME B16.9;
SCH STD
REDUCING TEE 6" X 4", SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME
B16.9; SCH STD; SIZE: 6" X 4"
REDUCING TEE, SEAMLESS, BW, ASTM A234 WPB, ASME B16.9; SCH 80
REDUCING TEE 6" X 4", SEAMLESS, BW, ASTM A234 WPB, ASME B16.9; SCH 80;
SIZE: 6" X4"
REDUCING TEE, SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME B16.9;
SCH 80
REDUCING TEE 6" X 3", SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME
B16.9; SCH 80; SIZE: 6" X 3"
REDUCING TEE 4" X 3", SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME
B16.9; SCH 80; SIZE: 4" X 3"
REDUCING TEE 4" X 2", SEAMLESS, BW, ASTM A234 WPB, INT. FBE LINED, ASME
B16.9; SCH 80; SIZE: 4" X 2"
RED TEE, WELDED, ASTM A860 WPHY 60, MSS-SP-75
REDUCING TEE 48" X 42", WELDED, BW, ASTM A860 WPHY 60, 0.279"X0.500; SIZE:
48" X 42"
RED TEE, SEAMLESS, ASTM A860 WPHY 60, INT. FBE LINED, MSS-SP-75
REDUCING TEE 10" X 8", SEAMLESS, BW,ASTM A860 WPHY 60,, INT. FBE LINED, ;
0.279"X0.500; SIZE: 10" X 8"
RED TEE, WELDED, ASTM A860 WPHY 65, MSS-SP-75
REDUCING TEE 42" X 30", WELDED, BW,ASTM A860 WPHY 65,INT. FBE LINED,
0.500"; SIZE: 42" X 30"
REDUCING TEE 42" X 16", WELDED, BW,ASTM A860 WPHY 65,INT. FBE LINED,;
0.750"; SIZE: 42" X 16"
RED TEE, WELDED, ASTM A860 WPHY 65, INT. FBE LINED, MSS-SP-75
REDUCING TEE 42" X 30", WELDED, BW,ASTM A860 WPHY 65,INT. FBE LINED,
0.750"X0.562"; SIZE: 42" X 30"
REDUCING TEE 18" X 16", WELDED, BW, ASTM A860 WPHY 65, INT. FBE LINED,
0.312"X0.375; SIZE: 18" X 16"

RED TEE,BARRED, WELDED, ASTM A860 WPHY 65, INT. FBE LINED, MSS-SP-75

REDUCING TEE,BARRED, 42" X 30", WELDED, BW,ASTM A860 WPHY 65,INT. FBE
LINED, ASME B16.9; 0.500"; SIZE: 42" X 30"

# Saudi Aramco: Confidential


REDUCING TEE,BARRED, 42" X 30", WELDED, BW,ASTM A860 WPHY 65,INT. FBE
LINED, ; 0.688"X0.562"; SIZE: 42" X 30"
REDUCER TEE, HDPE (HIGH-DENSITY POLYETHYLENE) PER 01-SAMSS-051 (ISO
4427), DESIGN PRESSURE:150 PSIG, DESIGN TEMP. 120F
REDUCER TEE, 16" X 8", HDPE (HIGH-DENSITY POLYETHYLENE)
REDUCER TEE, 8" X 4", HDPE (HIGH-DENSITY POLYETHYLENE)
FLANGE, CLASS 150, WN, FF, ASTM A105N, FBE LINED
FLANGE 2", CLASS 150, WN, FF, ASTM A105N, INT. FBE LINED, ASME B16.5; SCH 80

FLANGE 3", CLASS 150, WN, FF, ASTM A105N, INT. FBE LINED, ASME B16.5; SCH 40

FLANGE 4", CLASS 150, WN, FF, ASTM A105N, INT. FBE LINED, ASME B16.5; SCH 40
FLANGE, CLASS 150, WN, RF, ASTM A707 L3 CL3, INT. FBE LINED
FLANGE 42", CLASS 150, WN, RF, INT. FBE LINED, ASTM A707 L3 CL3, ASME
B16.47A SCH STD
FLANGE 36", CLASS 150, WN, RF, INT. FBE LINED, ASTM A707 L3 CL3, ASME
B16.47A,0.312" WT
FLANGE 40", CLASS 150, WN, RF, INT. FBE LINED, ASTM A707 L3 CL3, ASME
B16.47A SCH STD
FLANGE, CLASS 150, WN, RF, ASTM A707 L3 CL3,
FLANGE 42", CLASS 150, WN, RF, ASTM A707 L3 CL3, ASME B16.47A SCH STD

FLANGE 48", CLASS 150, WN, RF, ASTM A707 L3 CL3, ASME B16.47A SCH STD
FLANGE, CLASS 150, WN, RF, ASTM A105N, INT. FBE LINED
FLANGE 2", CLASS 150, WN, RF, ASTM A105N, INT. FBE LINED, ASME B16.5 SCH
XS
FLANGE 3", CLASS150, WN, RF, ASTM A105N, INT. FBE LINED, ASME B16.5 SCH 40

FLANGE 3", CLASS150, WN, RF, ASTM A105N, INT. FBE LINED, ASME B16.5 SCH XS

FLANGE 4", CLASS150, WN, RF, ASTM A105N, INT. FBE LINED, ASME B16.5 SCH 40

FLANGE 4", CLASS150, WN, RF, ASTM A105N, INT. FBE LINED, ASME B16.5 SCH XS

FLANGE 6", CLASS 150, WN, RF, ASTM A105N, INT. FBE LINED, ASME B16.5 SCH 40
FLANGE 10", CLASS 150, WN, RF, ASTM A105N, INT. FBE LINED, ASME B16.5 SCH
40
FLANGE, CLASS 150, WN, RF, ASTM 182 F316/316L,
FLANGE, PIPE: WN, 2" X 0.154" WT, CL 150, RF, SS, ASTM A182 F316/316L, PER
ASME B16.5 & 02-SAMSS-011.
FLANGE, CLASS 600, WN, RF, ASTM 182 F316/316L,

# Saudi Aramco: Confidential


FLANGE, PIPE: WN, 2" X 0.154" WT, CL 600, RF, SS, ASTM A182 F316/316L, PER
ASME B16.5 & 02-SAMSS-011.
FLANGE, CLASS 300, WN, RF, ASTM A859 A CL2
FLANGE 32", CLASS 300, WN, RF, ASTM A859 A CL2, ASME B16.47A; 0.500" WT

FLANGE 36", CLASS 300, WN, RF, ASTM A859 A CL2, ASME B16.47A; 0.500" WT

FLANGE 42", CLASS 300, WN, RF, ASTM A859 A CL2, ASME B16.47A; 0.750" WT

FLANGE, CLASS 300, WN, RF, ASTM A707 L3 CL3, INTERNALLY FBE COATED
FLANGE 40", CLASS 300, INTERNALLY FBE COATED WN, RF, ASTM A707 L3 CL3,
ASME B16.47A; SCH STD
FLANGE 48", CLASS 300, INTERNALLY FBE COATED WN, RF, ASTM A707 L3 CL3,
ASME B16.47A; SCH STD
FLANGE, CLASS 300, WN, RF, ASTM A105N, INTERNALLY FBE COATED
FLANGE 2", CLASS 300, INTERNALLY FBE COATED WN, RF, ASTM A105N, ASME
B16.5; SCH 80
FLANGE, CLASS 600, WN, RF, ASTM A859 A CL2
FLANGE 42", CLASS 600, WN, RF, ASTM A859 A CL2,ASME B16.47A; 0.688" WT

FLANGE 42", CLASS 600, WN, RF, ASTM A859 A CL2,ASME B16.47A; 0.750" WT

FLANGE 42", CLASS 600, WN, RF, ASTM A859 A CL2,ASME B16.47A; 0.500" WT

FLANGE, CLASS 600, WN, RF, ASTM A859 A CL2,INTERNALLY FBE COATED
FLANGE 16", CLASS 600, WN, RF, ASTM A859 A CL2,INTERNALLY FBE COATED,
ASME B16.5; 0.375"
FLANGE 18", CLASS 600, WN, RF, ASTM A859 A CL2,INTERNALLY FBE COATED,
ASME B16.5; 0.312"
FLANGE 24", CLASS 600, WN, RF, ASTM A859 A CL2,INTERNALLY FBE COATED,
ASME B16.5; 0.500"
FLANGE 30", CLASS 600, WN, RF, ASTM A859 A CL2,INTERNALLY FBE COATED,
ASME B16.47A; 0.562"
FLANGE 30", CLASS 600, WN, RF, ASTM A859 A CL2,INTERNALLY FBE COATED,
ASME B16.47A; 0.500"
FLANGE 47", CLASS 600, WN, RF, ASTM A859 A CL2,INTERNALLY FBE COATED,
ASME B16.47A; 0.750"

FLANGE, CLASS 600, WN, RF, ASTM A707 L3 CL3,INTERNALLY FBE COATED

FLANGE 8", CLASS 600, WN, RF, ASTM A707 L3 CL3,INTERNALLY FBE COATED,
ASME B16.5; SCH 80
FLANGE 10", CLASS 600, WN, RF, ASTM A707 L3 CL3,INTERNALLY FBE COATED,
ASME B16.5; 0.250" WT

# Saudi Aramco: Confidential


FLANGE 10", CLASS 600, WN, RF, ASTM A707 L3 CL3,INTERNALLY FBE COATED,
ASME B16.5; 0.279" WT
FLANGE, CLASS 600, WN, RF, ASTM A105N,INTERNALLY FBE COATED
FLANGE 2", CLASS 600, WN, RF, ASTM A105N, ASME B16.5; SCH 80
FLANGE 4", CLASS 600, WN, RF, ASTM A105N, ASME B16.5; SCH STD
FLANGE 4", CLASS 600, WN, RF, ASTM A105N, ASME B16.5; SCH 80
FLANGE 6", CLASS 600, WN, RF, ASTM A105N, ASME B16.5; SCH 80
FLANGE, HDPE (HIGH-DENSITY POLYETHYLENE) PER 01-SAMSS-051 (ISO 4427),
DESIGN PRESSURE: 150 PSIG, DESIGN TEMP. 120F WITH POLYPROPYLENE (PP)
COATED CS BACKING RING AND TO BE CONNECTED WITH CS CL-150 FF
FLANGES (PER ASME B16.5)
FLANGE, PIPE: 4" NPS, HDPE (HIGH-DENSITY POLYETHYLENE)
FLANGE, PIPE: 8" NPS, HDPE (HIGH-DENSITY POLYETHYLENE)
RTR (EPOXY RESIN), CL 150, FF
FLANGE, NON-METALLIC: 2", RTR (EPOXY RESIN), CL 150, FF,
BLIND FLANGE, CLASS 300, RF, ASTM A105N
BLIND FLANGE 2", CLASS 300, RF, ASTM A105N , ASME B16.5
BLIND FLANGE, CLASS 600, RF, ASTM A105N
BLIND FLANGE 2", CLASS 600, RF, ASTM A105N , ASME B16.5
BLIND FLANGE, CLASS 150, RF, ASTM A105N
BLIND FLANGE 2", CLASS 150, RF, ASTM A105N , ASME B16.5
BLIND FLANGE 2", CLASS 150, RF, ASTM A105N , ASME B16.5 (FBE LINED)
BLIND FLANGE 4", CLASS 150, RF, ASTM A105N , ASME B16.5 (FBE LINED)
BLIND FLANGE 6", CLASS 150, RF, ASTM A105N , ASME B16.5 (FBE LINED)
BLIND FLANGE 10", CLASS 150, RF, ASTM A105N , ASME B16.5 (FBE LINED)
BLIND FLANGE 42", CLASS 150, RF, ASTM A105N , ASME B16.47A
BLIND FLANGE 48", CLASS 150, RF, ASTM A105N , ASME B16.47A
BLIND FLANGE 36", CLASS 150 RF, ASTM A105N, ASME B16.47 SER.A (FBE LINED)
SPECTACLE BLIND , CLASS 150, RF, ASTM A516 GR.70, FBE LINED (REFER
STANDARD DRAWING STD. DWG. AD-036633.001)
SPECTACLE BLIND 6", CLASS 150, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND 4", CLASS 150, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND 3", CLASS 150, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND 10", CLASS 150, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND 36", CLASS 150, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND 40", CLASS 150, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND 42", CLASS 150, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND, CLASS 300, RF, ASTM A516 GR.70, (STD. DWG. AD-
036731.001)
SPECTACLE BLIND 48", CLASS 300, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND 48", CLASS 300, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND, CLASS 600, RF, ASTM A516 GR.70,(STD. DWG. AD-
036636.001)

# Saudi Aramco: Confidential


SPECTACLE BLIND 42", CLASS 600, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND 30", CLASS 600, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND 24", CLASS 600, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND 18", CLASS 600, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND 16", CLASS 600, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND 10", CLASS 600, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND 8", CLASS 600, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND 6", CLASS 600, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND 4", CLASS 600, RF, ASTM A516 GR.70, FBE LINED
SPECTACLE BLIND 2", CLASS 600, RF, ASTM A516 GR.70, FBE LINED
BARE INDUCTION BENDS (SUPPLY AND INSTALLED)
INDUCTION BEND: PIPE, BW, 42" NPS, 35 DEG. x 5D RADIUS, AS PER 
01‐SAMSS‐039; TO MATCH 42" NPS x 0.688" WT, API‐5L X65 MAINLINE
INDUCTION BEND: PIPE, BW, 42" NPS, 35 DEG. x 5D RADIUS, AS PER 
01‐SAMSS‐039; TO MATCH 42" NPS x 0.688" WT, API‐5L X65 MAINLINE
INDUCTION BEND: PIPE, BW, 18" NPS, 20 DEG. x 5D RADIUS, AS PER 01‐SAMSS‐
039; TO MATCH 18" NPS x 0.312" WT, API‐5L X65 (INTERNALLY FBE COATED )

INDUCTION BEND: PIPE, BW, 18" NPS, 30 DEG. x 5D RADIUS, AS PER  01‐SAMSS‐
039; TO MATCH 18" NPS x 0.312" WT, API‐5L X65 (INTERNALLY FBE COATED )

INDUCTION BEND: PIPE, BW, 10" NPS, 20 DEG. x 5D RADIUS, AS PER  01‐SAMSS‐
039; TO MATCH 10" NPS x 0.250" WT, API‐5L X60 (INTERNALLY FBE COATED )

INDUCTION BEND: PIPE, BW, 10" NPS, 30 DEG. x 5D RADIUS, AS PER 01‐SAMSS‐
039; TO MATCH 10" NPS x 0.250" WT, API‐5L X60 (INTERNALLY FBE COATED )
THRUST BORING (SUPPLY AND INSTALLATION)
PIPE, METALLIC: 42" NPS, 0.625" WT, BE, CS, SAW, API 5L GR.X65, PSL-2
PIPE, METALLIC: 18" NPS, 0.281" WT, BE, CS, LSAW, API 5L GR.X65, PSL-2, PER 01-
SAMSS-035 (TO BE INTERNALLY & EXTERNALLY FBE COATED)
PIPE, METALLIC: 10" NPS, 0.250" WT, BE, CS, SEAMLESS, API 5L GR.X60, PSL-2,
PER 01-SAMSS-035 (TO BE INTERNALLY & EXTERNALLY FBE COATED)
PIPING SPECIALTY ITEMS: (SUPPLY AND INSTALLATION)
SIGHT GLASS: 6" NPS, CL 600, RF,A216 WCB BODY WITH INTERNALLY FBE COATING, SS
410 FLAPPER MATERIAL & FLAPPER TYPE FLOW INDICATOR.
SIGHT GLASS: 4" NPS, CL 600, RF, A216 WCB BODY WITH INTERNALLY FBE COATING, SS
410 FLAPPER MATERIAL & FLAPPER TYPE FLOW INDICATOR.

STRAINER:10", CL 150, RF FLANGED, T - TYPE, STRAIGHT FLOW, A216 WCB WITH


INTERNALLY EPOXY LINED BODY, SS316 MESH, EXTERNALLY PAINTED WITH APCS-1E.

SAFETY SHOWER & EYE WASH (SUPPLY AND INSTALLATION)

# Saudi Aramco: Confidential


EYEWASH & SAFTEY SHOWER: SS TUBULAR PULL ROD OPERATED, FREE
STANDING, 1-1/4", FLOOR MTG, VERTICAL SUPPLY, YELLOW ABS PLASTIC HD,
ANSI Z358.1-1998, ASSEMBLY, WITH SS BOWL, HAND OPERATED, FLOOR
FLANGE, SHOWER AND EYE WASH OPERATED SEPARATELY, WITH PRESSURE
CONTROL DEVICE TO ENSURE CONSTANT WATER FLOW, STAY OPEN BALL
VALVES SHOWER FLOW RATE 30 GPM, EYEWASH FLOW RATE 3 GPM.

LINING & COATING (SUPPLY AND INSTALLATION)


48" NPS, 0.375" WT, APCS-102B INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
42" NPS, APCS-104B EXTERNAL FBE COATING, IN ACCORDANCE WITH 09-SAMSS-
089.
42" NPS, 0.750" WT, APCS-102B INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
42" NPS, 0.375" WT, APCS-102B INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
40" NPS, 0.375" WT, APCS-102B INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
36" NPS, 0.312" WT, APCS-102B INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
30" NPS, 0.562" WT, APCS-102B INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
30" NPS, 0.500" WT, APCS-102B INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
18" NPS, 0.250" WT, APCS-1E EXTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
18" NPS, 0.281" WT, APCS-1E EXTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
16" NPS, 0.375" WT, APCS-102B INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
18" NPS, 0.312" WT, APCS-102C INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
18" NPS, 0.250" WT, APCS-102C INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
18" NPS, 0.281" WT, APCS-102C INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
16" NPS, 0.375" WT, APCS-102C INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
10" NPS, 0.365" WT, APCS-102B INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
10" NPS, 0.250" WT, APCS-104A EXTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-089.
8" NPS, 0.500" WT, APCS-102C INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.

# Saudi Aramco: Confidential


6" NPS, 0.280" WT, APCS-102B INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
6" NPS, 0.432" WT, APCS-102C INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
10" NPS, 0.250" WT, APCS-102C INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
10" NPS, 0.279" WT, APCS-102C INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
6" NPS, 0.432" WT, APCS-102B INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
6" NPS, 0.280" WT, APCS-102B INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
4" NPS, 0.237" WT, APCS-102B INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
4" NPS, 0.337" WT, APCS-102C INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
4" NPS, 0.237" WT, APCS-102C INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
4" NPS, 0.337" WT, APCS-102B INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091. (SOUR SERVICE)
3" NPS, 0.216" WT, APCS-102B INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
2" NPS, 0.218" WT, APCS-102C INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
2" NPS, 0.218" WT, APCS-102B INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
2" NPS, 0.218" WT, APCS-102A INTERNAL FBE COATING, IN ACCORDANCE WITH
09-SAMSS-091.
Tie-In Welding

This work includes labor, equipment, paint and materials for preparing the surface
and painting. It also includes the cost of grit blasting or power tool cleaning.
Perform Flange, fitting and or pipe Tie-In Welds , 0.218" - 1.012" WT:
Including but not limited to cutting, beveling, aligning, pre-heat, post weld heat
treatment, welding of pipe to pipe, pipe to fittings or fittings to pipe (flange, tee,
reducer, elbow, etc.), painting or coating of girth welds, radiography of welds &
weld NDT and interpretation of NDT of 100% of the weld. (UT = Ultrasonic Testing;
MP= Magnetic Particle Testing; LP= Liquid Penetrant Testing), WUR for
radiography, UT, MP, LP and ND shall be as per WUR in Item 2.14

2"
3"
4"
6"

# Saudi Aramco: Confidential


8"
10"
12"
16"
18"
30"
32"
36"
40"
46"
48"
HOT TAP FITTINGS: (SUPPLY AND INSTALLATION)

SPLIT TEE: 48" X 30" NPS, TYPE -3 AS PER SA STANDARD DRAWING AB-036719,
TO BE WELDED TO 48" X 0.375" WT, API 5L X60 PIPE, BRANCH SIZE 30" X 0.500"
WT WITH LOCK-O-RING FLANGE, CLASS 300#, THE FITTING SHALL BE SUPPLIED
WITH LOCK-O-RING PLUG AND GUIDE BAR.(TO BE EXTERNALLY FBE COATED)

SPLIT TEE: 46" X 32" NPS, TYPE -3 AS PER SA STANDARD DRAWING AB-036719,
TO BE WELDED TO 46" X 0.375" WT, API 5L X65 PIPE, BRANCH SIZE 32" X 0.500"
WT WITH LOCK-O-RING FLANGE, CLASS 300#, THE FITTING SHALL COMPLY WITH
02-SAMSS-006. THE FITTING SHALL BE SUPPLIED WITH LOCK-O-RING PLUG AND
GUIDE BAR.

SPLIT TEE: 46" X 30" NPS, TYPE -3 AS PER SA STANDARD DRAWING AB-036719,
TO BE WELDED TO 46" X 0.400" WT, API 5L X60 PIPE, BRANCH SIZE 30" X 0.500"
WT WITH LOCK-O-RING FLANGE, CLASS 300#, THE FITTING SHALL BE SUPPLIED
WITH LOCK-O-RING PLUG AND GUIDE BAR.(TO BE EXTERNALLY FBE COATED)

SPLIT TEE: 56" X 42" NPS, TYPE -3 AS PER SA STANDARD DRAWING AB-036719,
TO BE WELDED TO 56" X 0.438" WT, API 5L X60 PIPE, BRANCH SIZE 42" X 0.750"
WT WITH LOCK-O-RING FLANGE, CLASS 300#, THE FITTING SHALL BE SUPPLIED
WITH LOCK-O-RING PLUG AND GUIDE BAR.(TO BE EXTERNALLY FBE COATED)

SPLIT TEE: 46" X 32" NPS, TYPE -3 AS PER SA STANDARD DRAWING AB-036719,
TO BE WELDED TO 46" X 0.375" WT, API 5L X65 PIPE, BRANCH SIZE 32" X 0.500"
WT WITH LOCK-O-RING FLANGE, CLASS 300#, THE FITTING SHALL COMPLY WITH
02-SAMSS-006. THE FITTING SHALL BE SUPPLIED WITH LOCK-O-RING PLUG AND
GUIDE BAR.
SPLIT TEE: 42" X 42" NPS, TYPE -3 AS PER SA STANDARD DRAWING AB-036719,
TO BE WELDED TO 42" X 0.562" WT, API 5L X60 PIPE, BRANCH SIZE 42" X 0.562"
WT WITH LOCK-O-RING FLANGE, CLASS 300#, THE FITTING SHALL COMPLY WITH
02-SAMSS-006. THE FITTING SHALL BE SUPPLIED WITH LOCK-O-RING PLUG AND
GUIDE BAR.

# Saudi Aramco: Confidential


SPLIT TEE-STOPPLE FITTING; 42"X42" NPS, TYPE-9 IN ACCORDANCE WITH STD.
DWG. AB-036719, TO BE WELDED TO 42"X0.562" WT, API 5L GR. X60 PIPELINE,
WITH LOCK-O-RING FLANGE, CL 600, RF, ASME B16.5. THE FITTING SHALL
COMPLY WITH 02-SAMSS-006. THE FITTING SHALL BE SUPPLIED WITH LOCK-O-
RING PLUG WITH SCRAFED NIPPLE.
SPLIT TEE: 42" X 32" NPS, TYPE -3 AS PER SA STANDARD DRAWING AB-036719,
TO BE WELDED TO 0.500" X 0.500" WT, API 5L X65 PIPE, BRANCH SIZE XX" X
0.XXX" WT WITH LOCK-O-RING FLANGE, CLASS 300#, THE FITTING SHALL
COMPLY WITH 02-SAMSS-006. THE FITTING SHALL BE SUPPLIED WITH LOCK-O-
RING PLUG AND GUIDE BAR.

SPLIT TEE: 40" X 16" NPS, TYPE -3 AS PER SA STANDARD DRAWING AB-036719,
TO BE WELDED TO 40" PIPE, BRANCH SIZE 16" X 0.375" WT WITH LOCK-O-RING
FLANGE, CLASS 600#, THE FITTING SHALL BE SUPPLIED WITH LOCK-O-RING
PLUG AND GUIDE BAR.(TO BE EXTERNALLY FBE COATED)

SPLIT TEE: 36" X 36" NPS, TYPE -3 AS PER SA STANDARD DRAWING AB-036719,
TO BE WELDED TO 36" X 0.500" WT, API 5L X60 PIPE, BRANCH SIZE 36" X 0.500"
WT WITH LOCK-O-RING FLANGE, CLASS 300#, THE FITTING SHALL COMPLY WITH
02-SAMSS-006. THE FITTING SHALL BE SUPPLIED WITH LOCK-O-RING PLUG AND
GUIDE BAR.
SPLIT TEE: 32" X 30" NPS, TYPE -3 AS PER SA STANDARD DRAWING AB-036719,
TO BE WELDED TO 30" X 0.312" WT, API 5L X65 PIPE, BRANCH SIZE 32" X 0.500"
WT WITH LOCK-O-RING FLANGE, CLASS 300#, THE FITTING SHALL COMPLY WITH
02-SAMSS-006. THE FITTING SHALL BE SUPPLIED WITH LOCK-O-RING PLUG AND
GUIDE BAR.
SPLIT TEE-STOPPLE FITTING; 30"X30" NPS, TYPE-9 IN ACCORDANCE WITH STD.
DWG. AB-036719, TO BE WELDED TO 30"X0.500" WT, API 5L GR. X60 PIPELINE,
WITH LOCK-O-RING FLANGE, CL 600, RF, ASME B16.5. THE FITTING SHALL
COMPLY WITH 02-SAMSS-006. THE FITTING SHALL BE SUPPLIED WITH LOCK-O-
RING PLUG WITH SCRAFED NIPPLE.

SPLIT TEE: 20" X 10" NPS, TYPE -3 AS PER SA STANDARD DRAWING AB-036719,
TO BE WELDED TO 20" PIPE, BRANCH SIZE 10" X 0.250" WT WITH LOCK-O-RING
FLANGE, CLASS 600#, THE FITTING SHALL BE SUPPLIED WITH LOCK-O-RING
PLUG AND GUIDE BAR.(TO BE EXTERNALLY FBE COATED)

LOCK-O-RING FLANGE: 42" X 0.562" WT, CL 300, RF, CS, ASTM A859 A CL2, PER
ASME B16.47A & 02-SAMSS-006.
LOCK-O-RING FLANGE: 42" X 0.750" WT, CL 600, RF, CS, ASTM A859 A CL2, PER
ASME B16.47A & 02-SAMSS-006.
PIPE, METALLIC: 36" NPS, 0.500" WT, BE, LSAW, API 5L X60, PSL-2, NON-SOUR
SERVICE, IN ACCORDANCE WITH 01-SAMSS-035.
LOCK-O-RING FLANGE: 30" X 0.500" WT, CL 300, RF, CS, ASTM A859 A CL2, PER
ASME B16.47A & 02-SAMSS-006.
LOCK-O-RING FLANGE: 10" X 0.279" WT, CL 600, RF, CS, A707 L3 CL3, PER ASME
B16.5 & 02-SAMSS-006.

# Saudi Aramco: Confidential


LOCK-O-RING FLANGE: 32" X 0.500" WT, CL 300, RF, CS, ASTM A859 A CL2, PER
ASME B16.47A & 02-SAMSS-006.
SPLIT TEE: 56" X 48" NPS, TYPE -3 AS PER SA STANDARD DRAWING AB-036719,
TO BE WELDED TO 56" X 0.438" WT, API 5L X60 PIPE, BRANCH SIZE 48" X 0.375"
WT AS PER ASME B31.4 WITH LOCK-O-RING FLANGE, CLASS 300#, THE FITTING
SHALL COMPLY WITH 02-SAMSS-006. THE FITTING SHALL BE SUPPLIED WITH
LOCK-O-RING PLUG AND GUIDE BAR.
(TO BE EXTERNALLY FBE COATED PER 09-SAMSS-089)
SPLIT TEE: 48" X 48" NPS, TYPE -3 AS PER SA STANDARD DRAWING AB-036719,
TO BE WELDED TO 48" X 0.500" WT, API 5L X60 PIPE, BRANCH SIZE 48" X 0.375"
WT AS PER ASME B31.4 WITH FLANGE, CLASS 300#, THE FITTING SHALL
COMPLY WITH 02-SAMSS-006. THE FITTING SHALL BE SUPPLIED WITH LOCK-O-
RING PLUG AND GUIDE BAR.

LOCK-O-RING FLANGE: 48" X 0.375" WT, CL 300, RF, CS, ASTM A707 L3 CL3, PER
ASME B16.47A & 02-SAMSS-006.
SPLIT TEE: 42" X 40" NPS, TYPE -3 AS PER SA STANDARD DRAWING AB-036719,
TO BE WELDED TO 42" X 0.875" WT, API 5L X52 PIPE, BRANCH SIZE 40" X 0.375"
WT AS PER ASME B 31.3 WITH FLANGE, CLASS 300#, THE FITTING SHALL
COMPLY WITH 02-SAMSS-006. THE FITTING SHALL BE SUPPLIED WITH LOCK-O-
RING PLUG AND GUIDE BAR.

SPLIT TEE: 42" X 40" NPS, TYPE -3 AS PER SA STANDARD DRAWING AB-036719,
TO BE WELDED TO 42" X 0.312" WT, API 5L Gr.B PIPE, BRANCH SIZE 40" X 0.375"
AS PER ASME B31.4 API 5L Gr.X60 WT WITH FLANGE, CLASS 150#, THE FITTING
SHALL COMPLY WITH 02-SAMSS-006. THE FITTING SHALL BE SUPPLIED WITH
LOCK-O-RING PLUG AND GUIDE BAR.

Supply, Installation and Testing of Fire Protection Devices; including excavation,


backfilling, concrete anchor, foundation, transportation, lifting and holding of the
device in place.
With PAINTING, External and Internal COATING as required.

HEAVY DUTY, HIGH FLOW MONITOR 4” FLANGED INLET, 2 ½ “NHT OUTLET WITH 1250
GPM FLOW CAPACITY, 200 PSI MAXIMUM WORKING PRESSURE. THE MONITOR SHALL
BE FM/UL LISTED.HYDRANT WET BARREL MONITOR, 1.2) MONITOR MOUNT FIRE
HYDRANT, 6” FLANGED INLET, 4” BARREL OUTLET; 2 x 2 ½ “ VALVED NHT WITH CAP &
CHAIN, 1 x 5” STORZ VALVED PUMPER NOZZLE WITH CAP & CHAIN AS PER JAMES JONES
MODEL J4060SPL-M, USA. THE HYDRANT SHALL BE FM/UL LISTED, 1.3) BREAK AWAY
CHECK VALVE; FOR BURIED INSTALLATION, 4” NPS, ASME CL 150, FLANGE BOLT
PATTERN PER ASME B16.5, CONSTRUCTED OF CAST IRON AND ALUMINIUM BRONZE
TRIM MATERIAL, INTERNALLY AND EXTERNALLY EPOXY COATED

# Saudi Aramco: Confidential


FIRE HYDRANT, 6” FLANGED INLET, 4” BARREL OUTLET; 2 x 2 ½ “ VALVED NHT WITH CAP
& CHAIN, 1 x 5” STORZ VALVED PUMPER NOZZLE WITH CAP & CHAIN AS PER JAMES
JONES MODEL J4060SPL-M, USA. THE HYDRANT SHALL BE FM/UL LISTED, 1.3) BREAK
AWAY CHECK VALVE; FOR BURIED INSTALLATION, 6” NPS, ASME CL 150, FLANGE BOLT
PATTERN PER ASME B16.5, CONSTRUCTED OF CAST IRON AND ALUMINIUM BRONZE
TRIM MATERIAL, INTERNALLY AND EXTERNALLY EPOXY COATED

FIRE HOSE REEL: CONSISTING OF FIRE HOSE, CABINET STAND, HOSE REEL FOR
STATIONARY MOUNTING WITH MANUAL RIGHT HAND SIDE REWIND WITH 30 INCH
CRANK, 1-1/2 INCH NST FEMALE INLET TO STRAIGHT SWIVEL JOINT AND 1-1/2 INCH NST
MALE OUTLET ON DRUM.
ELECTRICAL
Instrument/Power and Control Cable, in conduit or cable tray.
Provide & install power, control, composite, and instrumentation cables, in
conduits or cable trays including, cable pulling, installation of couplings, fittings,
seals, bends, etc. and ample length of tail for termination, sealing open ends of
cable, cable connections, wire lugs, identification numbers and color bands. The
rates for termination at both ends and testing of cables are to be provided
separately.

GROUNDING CABLES AND ACCESSORIES: PVC INSULATED, GREEN/YELLOW,


70 DEG C, COPPER CONDUCTOR, FRLS. LOW VOLTAGE (600VAC).
Cable/wire and terminations shall be fully compliant to NFPA-70

CABLE: ELECTRICAL, : STRANDED, POWER, 120 mm2, 1C-120 mm2


CABLE: ELECTRICAL, STRANDED, POWER, 70 mm2, 1C-70 mm2
CABLE: ELECTRICAL : STRANDED, POWER, 25 mm2, 1C-25mm2
GROUND ROD WITH TEST WELL: 16MM DIA, 2.4M LONG, COPPER JACKETED
STEEL
MASTER SAFETY GROUND BAR: TINNED COPPER, WITH ALL NECESSARY
HARDWARE, 25 NOS. OF HOLES FOR CONNECTING GROUNDING CONDUCTOR
UP TO 25 NOS. OF INSTRUMENTS
MASTER INSTRUMENT GROUND BAR: TINNED COOPER, WITH 25 HOLES FOR
CONNECTING GROUND WIRE.
THERMITE WELDING CONNECTION: ALL SIZES UP to 120 mm2.
GROUNDING LUG: FOR EQUIPMENT GROUND CONNECTION SUITABLE FOR 25-70
SQ. MM CONDUCTOR

LV ELECTRIC CABLES: SINGLE CONDUCTOR (Armored)


Price to design, engineer, supply, install, complete terminations at each/both end of
cable, and test 600V/1000V Armored CU/Type XLPE (SWA/PVC)/1C conductor
cable, either in cable tray, conduit, direct buried or duct bank, including, but not
limited to, handling, pulling, cutting, stub-ups, glands, lugs, labels, termination kits,
terminating and testing. Including excavation and backfilling, with all accessories.
XLPE INSULATED, PVC SHEATHED, 90 DEG C, COPPER CONDUCTOR. Cable/wire
and terminations shall be fully compliant to NFPA-70 or IEC-60502 & SAES-P-104

# Saudi Aramco: Confidential


Above ground 0-35 mm2
Above ground 50-120 mm2

LV ELECTRIC CABLES: SINGLE CONDUCTOR (Unarmored)


Price to design, engineer, supply, install, complete terminations at each/both end of
cable, and test 600V/1000V Unarmored CU/Type XLPE (PVC)/1C conductor cable,
either in cable tray, conduit, or duct bank, including, but not limited to, handling,
pulling, cutting, stub-ups, glands, lugs, labels, termination kits, terminating and
testing. Including excavation and backfilling, with all accessories. XLPE
INSULATED, PVC SHEATHED, 90 DEG C, COPPER CONDUCTOR. Cable/wire and
terminations shall be fully compliant to NFPA-70 or IEC-60502 & SAES-P-104

Above ground 0-35 mm2


Above ground 50-120 mm2

LV ELECTRIC CABLES: THREE CONDUCTOR


Price to design, engineer, supply, install, complete terminations at each/both end of
cable and test 600V/1000V Armored CU/Type XLPE (SWA/PVC) 3C+ Ground
conductor cable, either in cable tray, conduit, direct buried or duct bank, including,
but not limited to, handling, pulling, cutting, stub-ups, glands, lugs, labels,
termination kits, terminating and testing. Including excavation and backfilling, with
all accessories. XLPE INSULATED, PVC SHEATHED, 90 DEG C, COPPER
CONDUCTOR. Cable/wire and termination shall be fully compliant to NFPA-70 ,
IEC-60502-1 & SAES-P-104

Above ground 0-35 mm2


Above ground 50-120 mm2
Above ground 150-240 mm2

MV ELECTRIC CABLES: THREE CONDUCTOR


Price to design, engineer, supply, install, complete terminations at each/both end of
cable and test 5-15kV Unarmored CU/XLPE(PVC) 3C+ Ground conductor cable,
either in cable tray, conduit, or duct bank, including, but not limited to, handling,
pulling, cutting, stub-ups, glands, lugs, labels, termination kits, terminating and
testing. Including excavation and backfilling, with all accessories. Cable/wire and
termination shall be fully compliant to 15-SAMSS-502, IEC-60502-2 or AEIC CS8

Above ground 0-35 mm2

HV ELECTRIC CABLES 69KV upto 230KV: SINGLE CORE CONDUCTOR


Price to design, engineer, supply, install, complete outdoor terminations at
each/both end of cable, Link Box with accessories and test 69kV 1/C,
CU/XLPE/CUW/LAT/HDPE + Ground continuity cable, Bonding cables, direct buried
or duct bank, including, but not limited to, handling, pulling, cutting, stub-ups,
terminating , labels, termination kits, terminating and testing. Including excavation
and backfilling, with all accessories. 69kV power Cable, Link box and termination
shall be fully compliant to AEIC CS9, IEC60840, SEC Material specification 12-
TMSS-10, 12-TMSS-11.

# Saudi Aramco: Confidential


LIGHTING, RECEPTACLES & WIRING DEVICES.
All electrical devices shall be fully terminated per NFPA-70. Include all termination
lugs, terminals, blanks, barriers, and equipment/tool and testing equipment to
facilite this work. Shall be compliant to SA Material Supply Specifications.All
lighting shall be per SAES-P-123
Power Receptacle;480V; 25W;outlet, Outdoor; weatherproof welding receptacle
30 FEET HIGH FLOOD LIGHT POLE WITH 1-150WATTS, LED LUMINAIRE.

CONDUITS: Price to Design, Engineer, Supply and install RGS Conduit, uncoated or
PVC Coated,hot dip galvanized, above ground, including, but not limited to:
trenching, backfill material, backfilling, compaction, couplings, union bodies,
sealing compound, hubs, deck penetrations, cutting, clamping, fittings and
necessary supports.Conduit and fittings shall be as per SAES-P-104

CONDUITS ACCESSORIES
CONDUITS ELBOWS FOR: 1" to 2", PVC Coated RGS

CONDUITS: Price to Design, Engineer, Supply and install RGS Conduit, uncoated ,
PVC Coated, direct buried , including, but not limited to: trenching, backfill material,
backfilling, compaction, couplings, union bodies, sealing compound, hubs, deck
penetrations, cutting, clamping, fittings and necessary supports.Conduit and
fittings shall be as per SAES-P-104

1" PVC Coated RGS


CONDUITS ACCESSORIES
CONDUITS ELBOWS FOR: 1" to 2", PVC Coated RGS
Miscellaneous Electrical:
Price to Design, Engineer, Excavate, supply, install, backfill and compact road
crossing ducts consisting of PVC ducts with bell-ends, entirely encased with red
coloured, reinforced concrete
1" PVC ducts
POWER PANELS
Panel Board; LV; 400/230V; 100A, 3 Phase, 4W, 10kA ; 36 Ckts; wall mounted; in
compliance with 16-SAMSS-518, Non-hazradous area
Lighting Panel Board; LV; 400/230V; 100A, 3 Phase, 4W, 10kA ; 12 Ckts; in compliance
with 16-SAMSS-518 , Non-hazradous area
Lighting control panel; with HOA selector switch, 400V,100A,3 phase, 60Hz; 3- pole
contactor; NEMA 1 Enclosure , Non-hazradous area
DC PANELBOARD: OUTDOOR (NEMA-4X), 24VDC, 100A, 60HZ, 10KA SYMM
UPS PANEL
Additional Electrical Items :
PAD MOUNTED LOOP FEED DISTRIBUTION TRANSFORMER 75KVA, DYN 1, 13.8kV-
0.48kV, 3 PHASE, 60 HZ, %Z= 4.00%

# Saudi Aramco: Confidential


OFF GRID SOLAR PV SYSTEM, 8 KW OUTPUT POWER, COMPLETE WITH PV
MODULE, PV MOUNTING STRUCTURE, BATTERY BOXES, ENERGY STORAGE
SYSTEM (NI-CAD), PASSIVE COOLING, MPPT CHARGE CONTROLLERS, DC/DC
CONVERTERS, DISTRIBUTION PANEL, SYSTEM ENCLOSURE, ANTI THEFT
MECHANISM AS PER TECG.
SWITCHRACK : OUTDOOR, 100 A BUS, 480 V, 3 PHASE, 3 W, 60 HZ, 10 KAIC, NEMA
4 ENCLOSURE, COMPLETE WITH POWER PANEL, 15 KVA XFMR, CIRCUIT
BREAKERS, LIGHTING CONTACTOR PANEL ETC.
INSTRUMENTATION

Instrument Cables
Provide and install power, control, composite and instrumentation cable in either
cable tray, conduit including cable laying, cable pulling, splicing and cover ample
length of tail for termination of both ends, testing, sealing open ends after cutting,
trays and conduit supports, Identification numbers and color bands. The rates for
the termination and testing are specified separately in column below.

Cable; Instrument; 1pr, 1.5mm² SHLD, CU/XLPE/UA/300V Un Armored


Cable; Instrument; 1pr, 1.5mm² UN SHLD, CU/XLPE/UA/300V Un Armored
Cable; Instrument; 8prs, 1.0mm² IND AND O/A SHLD CU/XLPE/UA/300V Un Armored

Cable; Instrument; 16prs, 1.0mm² IND AND O/A SHLD CU/XLPE/UA/300V Un Armored

Cable; Instrument; 2pr, 1.5mm² IND AND OA SHLD, CU/XLPE/UA/300V Un Armored


Cable; Instrument; 1pr, 12AWG SHLD, CU/XLPE/UA/300V Un Armored
Cable; Instrument; 1Tr, 16AWG SHLD, CU/XLPE/UA/300V Un Armored
Cable; Instrument; 1Tr, 12AWG SHLD, CU/XLPE/UA/300V Un Armored
Cable; Instrument; 3Trs, 12AWG IND AND O/A SHLD CU/XLPE/UA/300V Un Armored

Cable; Instrument; 3prs, 1.5mm² IND AND O/A SHLD CU/XLPE/UA/300V Un Armored

Cable; Instrument; 3prs, 12AWG IND AND O/A SHLD CU/XLPE/UA/300V Un Armored

Cable; Instrument; 4prs, 1.5mm² IND AND O/A SHLD CU/XLPE/UA/300V Un Armored

Cable; Instrument; 8prs, 1.5mm² IND AND O/A SHLD CU/XLPE/UA/300V Un Armored

Cable; Instrument; 6prs, 12 AWG IND AND O/A SHLD CU/XLPE/UA/300V Un Armored

Cable; Instrument; 12prs, 1.0mm² IND AND O/A SHLD CU/XLPE/UA/300V Un Armored

Cable; Instrument; 12prs, 1.5mm² IND AND O/A SHLD CU/XLPE/UA/300V Un Armored

Cable; Instrument; 12prs, 12AWG IND AND O/A SHLD CU/XLPE/UA/300V Un Armored

# Saudi Aramco: Confidential


Cable; Instrument; 24prs, 16AWG IND AND O/A SHLD CU/XLPE/UA/300V Un Armored

Cable; Instrument; 24prs, 18AWG IND AND O/A SHLD CU/XLPE/UA/300V Un Armored

Cable; Instrument;32pr, 16AWG IND AND O/A SHLD, CU/XLPE/UA/300V Un Armored

Cable; Instrument;36pr, 16AWG IND AND O/A SHLD, CU/XLPE/UA/300V Un Armored

Cable; Instrument;36pr, 18AWG IND AND O/A SHLD, CU/XLPE/UA/300V Un Armored

Cable; Instrument;16pr, 18AWG IND AND O/A SHLD, CU/XLPE/UA/300V Un Armored


CABLE: 1-4PR, ETHERNET CABLE: CAT-6 CABLE
CABLE: 1-2PR, 22 AWG, RS-485: SERIAL DATA LINK CABLE
CABLE TRAY & FIXING ACCESSORIES
Cable Tray; Straight; LadderType; w/ cover 24"W' x 6" color hight
Cable Tray; Horizontal Tee; 24"W X 24"W Ladder type w/ cover
Cable Tray; Vertical Inside Elbow, 90 degrees 24"W ladder type w/ cover
Cable Tray; Vertical Outside Elbow, 90 degrees 24"W Ladder type w/ cover
Cable Tray; Horizontal Outside Elbow, 90 degrees 24"W Ladder type w/ cover
HOLD DOWN CLAMP WITH NECESSARY FASTENERS
COVER CLAMP WITH NECESSARY FASTENERS
CABLE TRAY EARTHING JUMPER CABLE OR EARTHING CABLE WITH NECESSARY
FASTENERS
SPLICE PLATES WITH NECESSARY FASTENERS
HORIZONTAL ADJUSTABLE SPLICE PLATES WITH NECESSARY FASTENERS
CONDUIT & CONDUIT FITTING
Conduit; 3/4"Ø; RGS; Hot Dipped Galvanized, with coupling one end.
Conduit; 1"Ø; RGS; Hot Dipped Galvanized, with coupling one end.
Conduit; 1-1/2"Ø; RGS; Hot Dipped Galvanized, with coupling one end.
Coupling; 3/4"Ø; RGS; Hot Dipped Galvanized
Coupling; 1"Ø; RGS; Hot Dipped Galvanized
Coupling; 1-1/2"Ø; RGS; Hot Dipped Galvanized
Elbow; 90Deg, 3/4"Ø; RGS; Hot Dipped Galvanized
Elbow; 90Deg, 1"Ø; RGS; Hot Dipped Galvanized
Elbow; 90Deg, 1.5"Ø; RGS; Hot Dipped Galvanized
Nipple; 3/4"Ø x 2"; RGS; Hot Dipped Galvanized
Nipple; 1"Ø x 2"; RGS; Hot Dipped Galvanized
Nipple; 1.5"Ø x 2"; RGS; Hot Dipped Galvanized
Nipple; 3/4"Ø x 4"; RGS; Hot Dipped Galvanized
Nipple; 1"Ø x 4"; RGS; Hot Dipped Galvanized
Nipple; 1.5"Ø x 4"; RGS; Hot Dipped Galvanized
Union; 3/4"Ø; RGS; Hot Dipped Galvanized
Union; 1"Ø; RGS; Hot Dipped Galvanized
Union; 1.5"Ø; RGS; Hot Dipped Galvanized

# Saudi Aramco: Confidential


Conduit Body type TEE,3/4"Ø; RGS, HD Galvanized
Conduit Body type TEE,1"Ø; RGS, HD Galvanized
Conduit Body type TEE,1.5"Ø; RGS, HD Galvanized
HUB MYERS, 3/4"Ø; RGS, HDG, PVC Coated
HUB MYERS, 1"Ø; RGS, HDG, PVC Coated
HUB MYERS, 1.5"Ø; RGS, HDG, PVC Coated
Conduit Body type LR, 3/4"Ø; RGS, HDG, with cover and gasket
Conduit Body type LR, 1"Ø; RGS, HDG, with cover and gasket
Conduit Body type LR, 1.5"Ø; RGS, HDG, with cover and gasket
Conduit Body type LL, 3/4"Ø; RGS, HDG, with cover and gasket
Conduit Body type LL, 1"Ø; RGS, HDG, with cover and gasket
Conduit Body type LL, 1.5"Ø; RGS, HDG, with cover and gasket
Conduit Body type LB, 3/4"Ø; RGS, HDG, with cover and gasket
Conduit Body type LB, 1"Ø; RGS, HDG, with cover and gasket
Conduit Body type LB, 1.5"Ø; RGS, HDG, with cover and gasket
REDUCERS, RGS, Hot Dipped Galvanized, 1-1/2" x 1"
REDUCERS, RGS, Hot Dipped Galvanized, 1-1/2" x 3/4"
REDUCERS, RGS, Hot Dipped Galvanized, 1" x 3/4"
UNISTRUT CHANNEL
UNISTRUT CLAMP; 3/4" DIA, RGS
UNISTRUT CLAMP; 1" DIA, RGS
UNISTRUT CLAMP; 1-1/2" DIA, RGS
Coupling; 2"Ø; RGS; Hot Dipped Galvanized
Elbow; 90Deg, 2"Ø; RGS; Hot Dipped Galvanized
Nipple; 2"Ø x 2"; RGS; Hot Dipped Galvanized
Nipple; 2"Ø x 4"; RGS; Hot Dipped Galvanized
Union; 2"Ø; RGS; Hot Dipped Galvanized
Conduit Body type TEE,2"Ø; RGS, HD Galvanized
HUB MYERS, 2"Ø; RGS, HDG, PVC Coated
Conduit Body type LR, 2"Ø; RGS, HDG, with cover and gasket
Conduit Body type LL, 2"Ø; RGS, HDG, with cover and gasket
Conduit Body type LB, 2"Ø; RGS, HDG, with cover and gasket
REDUCERS, RGS, Hot Dipped Galvanized, 2" x 1"
UNISTRUT CLAMP; 2" DIA, RGS
JUNCTION BOX
CONTRACTOR shall provide, install JB complete, including mounting, termination,
testing

INSTRUMENT JUNCTION BOX: COMPLETE WITH ALL FITTINGS. NEMA 4X, 316
STAINLESS STEEL, CAPTIVE CLAMPS OTHER ACCESSORIES AS REQUIRED:
TERMINAL BLOCKS (CORROSION RESISTANT) FOR 12 AWG INSTRUMENT CABLE
TERMINATION, VERTICAL DIN RAIL WITH 20% UNUSED RAIL LENGTH. IN
ACCORDANCE WITH SAES-J-902

# Saudi Aramco: Confidential


RS-485 TO ETHERNET CONVERTOR JUNCTION BOX:
RS-485 TO ETHERNET CONVERTOR INDIDE THE JB,COMPLETE WITH ALL
FITTINGS. NEMA 4X, 316 STAINLESS STEEL, CAPTIVE CLAMPS OTHER
ACCESSORIES AS REQUIRED:
TERMINAL BLOCKS (CORROSION RESISTANT) FOR 12 AWG INSTRUMENT CABLE
TERMINATION,
VERTICAL DIN RAIL WITH 20% UNUSED RAIL LENGTH. IN ACCORDANCE WITH
SAES-J-902
JB STAND SUPPORT & ACCESSORIES
CHANNEL STRUCTURAL C6 x13 CS A37, GALVANIZED
CHANNEL STRUCTURAL C4 x 5.4CS A36, GALVANIZED
CHANNEL FRAMING GALV STEEL 10FT LG x 2" WD x 1.5" DP, GALVANIZED
PLATE STEEL 1 SQ FT, GALVANIZED
ANCHOR BOLT MACH TYPE: 1/2" x 75MM LONG,
C-CHANNEL FRAMING STRUCTURAL STEEL UAP-130, GALVANIZED
HEX HEAD CAP SCREW 12.7 x 38.1mm,
FENDER WASHER 12.7mm,
HOLD DOWN CLAMP,
REGULAR SPRING NUT 13mm,
FLAT PLATE FITTINGS,
INSTRUMENT STAND SUPPORT ON PLATFORM
BOLT; WITH NUT; 1/4", 4.5" (114mm) LG
BAR STEEL; 6 x 50x 150mm
2" PIPE, SEAMLESS STEEL, SCH 80
ANGLE BAR 102 x 76 x 300mm
ELECTRICAL CONNECTION & INSTRUMENT INSTALLATION ACCESSORIES
TEE; THREADED, SST316; ANSI Class 3000 1/2"
PLUG; PIPE; SST316;1/2"CONNECTOR MALE THREAD CONNECTOR MALE
SST316ED
CONNECTOR MALE SST316, 1/2" TUBE, 1/2" PIPE
TUBING; SST316, 1/2" O.D. 6m (20 FT)
TUBE; SST 316 1/4"
CONNECTOR MALE SST316, 1/4" TUBE, 1/4" PIPE
UNION; SST316; 1/2 IN" IN THREADED TUBING, CLASS 3000
VALVE GATE; THREADED, SST316; ANSI CLASS 1500; 1/2", RGS, HDG,PVC Coated
NIPPLE; RGS;1/2"X51mm (2") long, PVC COATED, RGS, HDG,PVC Coated
NIPPLE; RGS,PIPE STEEL;1/2"X150mm (6") long, SST316
CONNECTOR MALE SST316, 3/8" TUBE, 1/4" PIPE
CONNECTOR MALE SST316, 3/8" TUBE, 1/2" PIPE
TUBING SST 316 3/8" OD
SST316, CAP FOR TUBE END 1/4"
FLEXIBLE COUPLING, 3/4" NPT x FEMALE UNION

# Saudi Aramco: Confidential


CONDUIT GUAC FITTING, 3/4" WITH TWO (2) STRIPS TERMINALS, 'RGS, Hot Dipped
Galv.
SEAL FITTING 3/4", EYS TYPE, RGS
SEALING COMPOUND W/ CHICO 115 Cu. In
INSTRUMENTS
CONTRACTOR shall supply & install instruments, including supplying and
installing support stands, foundations, process piping, tubing with fittings up to 10
meters, isolation valves, electrical connections, tagging, testing pre-commissioning
and checkouts as per SAES.
RTU (REMOTE TERMINAL UNIT):
CABINETS , PROCESSOR, I/O’S MODULES
AS PER REFERENCE FSD DOCUMENT : PE-J11003,
RTU (REMOTE TERMINAL UNIT) MODIFICATION:

AS PER REFERENCE FSD DOCUMENT : PE-J11005, PE-J15204


PLC (PROGRAMMABLE LOGIC CONTROLLER):
CABINETS , PROCESSOR, I/O’S MODULES
AS PER REFERENCE FSD DOCUMENT : PE-J11003
EMERGENCY SHUTDOWN SYSTEM (ESD) MODIFICATION:

AS PER REFERENCE FSD DOCUMENT : PE-J11006


DISTRIBUTED CONTROL SYSTEM (DCS) MODIFICATION:

AS PER REFERENCE FSD DOCUMENT : PE-J15304, PE-J15404


INSTRUMENTS remaining items
GUIDED WAVE RADAR LEVEL TRANSMITTER: 3" FLANGED 150#, MAT: 316L SS,
AREA CLASS: CL-1,ZN-2, NEMA 4X, TRANSMETTER HOUSING WITH INTEGRAL
LOCAL INDICATOR
MONITOR, CORROSION TYPE INCLUDING PROBES, FITTINGS AND RELATED
INSTRUMENTS. 2" 600# RF FLANGED, SENSOR MATERIAL SS 316 L,
TEMPERATURE THERMOWELL : BODY MTRL: 316L SS, COVE: SCREW
CAP&CHAIN, PROC CONN: FLANGED 2" ANSI 600# RF, INTERAL THREAD: 1/2" NPT,
BORE I. D. :0.26".

TEMPERATURE ELEMENT: TYPE: PLANTINUM WITH R100/RO=1.3926(SAMARC. 21-


4), LEADS: MFG.STD./HERM. SEALED, MTRL: 316L SS, SHEAT O.D. : 1/4", CONN
SIZE: 3/4" NPT, NEMA 4X/7, CONDUIT CONN SIZE:3/4" NPT

ORIFICE PLATE : PLATE MTRL: SS, TYPE OF TAPS: FLANGE, METER TYPE: DP,
DIFF RANGE: 0-100 in H2O, RATING AND TYPE OF FLANGES: ANSI 600#RF

DP FLOW TRANSMITTER : AREA CLASS: CL-1,ZN-2, NEMA 4X , MTRL: 316 SS,


ELECTRICAL & PRO CONN: 1/2 in, MOUNTING: 2 in, MANFOLD: 5 WAY, COMM
PROTOCOL: HART, SIGNAL O/P: 4-20 mA,

# Saudi Aramco: Confidential


FLOW ELEMENT, TRANSMITTER: VENTURI TUBE, 4-20mA, REFER TO ISS No. PE-
J12627
PRESSURE RELIEF VAVES: AS PER DATA SHEETS TYPE: CONVENTIONAL
(THERMAL) TYPE,
CONTROL VALVE : AS PER DATA SHEETS ACTUATOR TYPE:ELEC, AREA CLASS:
CL-1,ZN-2, GLAND PACKING MTRL: PTFE, SHAFT & DISC MTRL:A216-WCB ISS : PE-
J12628
CORROSION MONTORING COUPON:
CORROSION MONTORING COUPON, 600#, FLANGED, SS 316L
CORROSION MONTORING TRANSMITTER: WITH JUNCTION BOX,
MOTOR OPERATED VALVE: AS PER DATA SHEETS, AREA CLASS: CL-1,ZN-2,
SERVICE: INTERMITTENT, MOTOR SUPPLY VOLTAGE V/FREQUENCY Hz: 480 V 3Φ,
60HZ, RATING: 600# RF, STEM POSITION: VERTICAL CONTROL VOLTAGE AC/DC:
24 VDC. ISS : PE-J12017, PE-J12317, PE-J12417, PE-J12517, PE-J12617, PE-J13017,
PE-J13117, PE-J14017, PE-J14117
MOTOR OPERATED VALVE: AS PER DATA SHEETS, AREA CLASS: CL-1,ZN-2,
SERVICE: INTERMITTENT, MOTOR SUPPLY VOLTAGE V/FREQUENCY Hz: 24 VDC,
RATING: 600# RF, STEM POSITION: VERTICAL CONTROL VOLTAGE AC/DC: 24
VDC. ISS : PE-J12117, PE-J12217
COMBUSTIBLE GAS DETECTOR: COMBUSTIBLE (LEL), INFRARED POINT
CALIBRATED RANGE 0 - 100 %, OUTPUT SIGNAL RANGE 0 -22 mA, HART, POWER
SUPPLY 24VDC, ISS : PE-J13024, PE-J13124, PE-J14024, PE-J14124
BEACON RED FOR LEL GAS DETECTOR: AS PER DATA SHEETS, CL1, ZN2, GR
C&D, NEMA 4X/8, BLUE LIGHT, 3/4" NPT, POWER SUPPLY:24 VDC ISS: PE-J13025,
PE-J13125, PE-J14025, PE-J14125
BEACON WHITE: AS PER DATA SHEETS, CL1, ZN2, GR C&D, NEMA 4X/8, BLUE
LIGHT, 3/4" NPT, POWER SUPPLY:24 VDC ISS: PE-J13025, PE-J13125, PE-J14025,
PE-J14125

HORN FOR LEL GAS DETECTOR: AS PER DATA SHEETS, CL1, ZN2, GR C&D,
NEMA 4X/7, 24 VDC 2" PIPE MOUNTING, 3/4" NPTF, SELECTABLE TONE AND
ADJUSTABLE SOUND LEVEL ISS : PE-J13026, PE-J13129, PE-J14026, PE-J14126

PRESSURE GAUGE: DIAL 100 mm (4 1/2) in, 1/2 in NPT, BOTTOM CONN, PIPE
MOUNTING, ELEMENT TYPE: BOURDON, ELEMENT MAT:316 SS, HOUSING:
PHENOLIC, STEM MATERIAL : 316L SS,
PRESSURE TRANSMITTER: MTRL: 316L SST COMM PROTOCOL: HART,WETTED
PARTS: 316L SST PROC CONN SIZE & TYPE: 1/2"NPT,SIGNAL O/P: 4-20 mA,
NEMA4X, INDICATOR:INTEGRAL, MANIFOLD:3 WAY.
GUIDED WAVE RADAR LEVEL TRANSMITTER: AS PER DATA SHEETS, ROD, 3"
FLANGED 150#, MAT: 316L SS, AREA CLASS: CL-1,ZN-2, NEMA 4X, T WITH
INTEGRAL LOCAL INDICATOR ISS : PE-J12629
LEVEL GAUGE: AS PER DATA SHEETS, MAGNATIC, SS 316L, 2" 150# RF,
SIDE/SIDE, CHAMBER DIA. 2" ISS: PE-J12630
LEVEL BEACON: AS PER DATA SHEETS, AMBER, CL-1, ZN-2, NEMA 4X, ISS: PE-
J12631

# Saudi Aramco: Confidential


LEVEL HORN: AS PER DATA SHEETS, AMBER, CL-1, ZN-2, NEMA 4X, ISS: PE-
J12631
SURGE RELIEF SKID (SRS)
TEMPERATURE TRANSMITTER: SIGNAL O/P: 4-20 mA, COMM PROTOCOL: HART,
AREA CLASS: CL-1,ZN-2, NEMA 4X, ELECTRICAL CONN SIZE: 1/2in NPT,
INDICATOR: INTERGRAL.
EMERGENCY ISOLATION VALVE: AS PER DATA SHEET, STEM POSITION:
VERTICAL, NEMA 4X, AREA CL: CL-1,ZN-2, CONTROL SIGNAL: 4-20 mA, ISS : PE-
J12625
SCRAPER PASSAGE INDICATOR: NON-INTRUSIVE TYPE,
SCRAPER PASSAGE INDICATOR (LOCAL): NON-INTRUSIVE TYPE, WITH IN-BUILT
BATTERY
Communication

CONDUIT, 4" PVC TYPE DB 20' LONG


CONDUIT, 4" HDPE
CEMENT; FOR PVC CONDUIT; 1 QT/CN
PRIMER; SOLVENT CEMENT FOR PVC (ONE PRIMER PER TWO CEMENT)
SPACER, CONDUIT PVC 4" BASE
FISHLINE ROPE 1/4" X 2000'/RO (600M)
GMP PLUG CONDUIT, SOLID RUBBER EXPANDABLE, 101.6MM (4") FOR SEALING
UNOCCUPIED DUCT
REINFORCED 6" TAPE MARKING BURIED CABLE, TAPE SAFETY BARRIER MARKING CAUTION:
TELECOMMUNICATIONS CABLE BELOW (305M OR 100 FT PER ROLL), ARABIC AND ENGLISH,
ORANGE IN BLACK LETTERING, PLASTIC,ALKHALI,ACID AND PETROLEUM RESISTANT WITH
METALIZED FOIL COIL, PRINTED ON TAPE.
TRENCHING ACCESSORIES
MARKER POST
SIGN WARNING UNDERGROUND
TELEPHONE CABLE
SIGN WARNING SINGLE POINTED ARROW
SIGN WARNING DOUBLE POINTED ARROW
SIGN - SPLICE NUMBER
SIGN - SPLICE LOCATION & FOC NUMBER
EMS-1250 (3M COMPANY EMS FULL RANGE)
PEDESTAL
BURIED CLOSURE; PEDESTAL UP-1278 TYPE WITH MOUNTING STAKE
PIPE; STEEL SEAMLESS,4" NOM:6.02MM (0.237") FOR PEDESTAL GUARD RAIL
PAINT ENAMEL YELLOW, EXTERIOR/INTERIOR (5 LT/CAN)
PAINT ENAMEL BLACK, EXTERIOR/INTERIOR (5 LT/CAN)
THINNER, METHYL ETHYL KETONE,5LT/CAN
TAG TERM.LEAD SLOT & TONGUE TYPE # 7270-B: 25/PK
TIE: CABLE STRAP & CLAMP; NYLON SELF LOCKING; 13.93 IN LONG; 50/PK
TAPE INSULATING, FIRE PROOF 1 1/2" X 20" LONG
SUB-DUCT
SUB-DUCT PLUG 1" DIA; JACKMOON DUCT PLUGS, MODEL #10D104U

# Saudi Aramco: Confidential


4" DIA. DUCT PLUG
4-HOLE DUCT PLUG FOR 4" DIA. CONDUIT,
JACKMOON MODEL #4OQ136S
SIMPLEX (SPLIT DUCT PLUG 1" JACK MOON DUCT PLUG MODEL #09S050SB)
INNERDUCT,1" DIA., PLAIN POLYETHYLENE E/W PULL ROPE- GREEN
INNERDUCT,1" DIA., PLAIN POLYETHYLENE E/W PULL ROPE- ORANGE
INNERDUCT,1" DIA., PLAIN POLYETHYLENE E/W PULL ROPE- BLUE
INNERDUCT,1" DIA., PLAIN POLYETHYLENE E/W PULL ROPE- RED
INDOOR
FIBER CABLE, 24F PLENUM RATED ITU.G.652D,INDOOR FOC
HORIZONTAL/BACKBONE CABLING
MODULAR IDC-RJ45 OUTLET, CAT 6, GIGAFLEX PS6+ MODULE, T568A/B, BLUE, (BELDEN) , P/N
AX101071
INTERFACE PLATE, FLUSH 2-PORT, SINGLE GANG FLUSH, ALMOND (BELDEN), P/N AX101432
DATATWIST 2400, NONBONDED-PAIR, 4-PAIR 23 AWG, CMP, CAT6, BLUE, 305M (1000FT) PER BOX
(BELDEN), P/N 2413D15U1000
2U PATCH CORD MANAGEMENT (BELDEN), P/N AX100795
19" RACK-MOUNTABLE IDC/RJ 45 DATA PATCH PANEL-24 PORT UTP CAT6, GIGAFLEX PS6, 1U,
BLACK (BELDEN), P/N AX103253
GIGAFLEX PS6+ MODULAR PATCH CORD, 4-PAIR, 23 AWG SOLID, T568A-T568A, BLUE, 2.1M (7 FT.)
(BELDEN), P/N AX350039
GIGAFLEX PS6+ MODULAR PATCH CORD, 4-PAIR, 23 AWG SOLID, T568A-T568A, BLUE, 3.0M (10
FT.) (BELDEN), P/N AX350040
TELECOMMUNICATIONS SPACE
CUBE IT PLUS WALL MOUNT CABINET, 24"Wx24"Hx24"D
(CPI), P/N 11900-224
EXTRA MOUNTING RAILS (CPI), P/N 12787-524
HORIZONTAL WIRE MANAGEMENT BAR (CPI), P/N 11837-201
FAN KIT (CPI), P/N 12804-701
UNIVERSAL RACK, 45U, UL LISTED, 7'H X 19"W (CPI), P/N 48353-103
SINGLE-SIDED WIDE VERTICAL CABLING SECTION, 7'H X 6"W X 6.38"D,
P/N 11374-703
RACK AND FRAME INSTALLATION KITS, CONCRETE FLOOR, 3/8", ZINC,
P/N 40604-001
POWER DISTRIBUTION UNIT, HORIZONTAL RACK-MOUNT, 200/240V, 20A (CPI), P/N 35682-111
HORIZONTAL RACK BUSBAR, FOR 19" RACK, (CPI) P/N 10610-019
#6 AWG INSULATED COPPER WIRE (GREEN), P/N 15-195-359
CABLE RUNWAY, 12" WIDE (CPI), 10FT,
P/N 10250-112
CABLE RUNWAY, 24" WIDE (CPI), 10FT,
P/N 10250-124
JUNCTION SPLICE KIT (CPI), P/N 16302-001
WALL ANGLE SUPPORT KIT FOR 12" CABLE RUNWAY, 2"x2"x3/16" (CPI), PN 11421-112
VERTICAL WALL BRACKET (CPI),
P/N 10608-001
CHANNEL RACK-TO-RUNWAY MOUNTING PLATE, 12" RUNWAY (CPI), P/N 10595-112
CABLETRAY DROP-OUT (ABAHSAIN), P/N 4-215DO
CANTILEVER ARMS, ABAHSAIN,
P/N P2663/300

# Saudi Aramco: Confidential


90 DEG. ANGLE FITTING (ABAHSAIN-COPE),
P/N P1068
CHANNEL SLOTTED 1-5/8" x 1 5/8" (ABAHSAIN), P/N A-12005 x 10', HDG
REGULAR SPRING NUT, 3/8"
GROUNDING
TGB GROUND BUSBAR, 1/4x2x10 (CPI), P/N 13622-010
TMGB GROUND BUSBAR, 1/4 X 4 X20" (ERICO), P/N TMGB-A20L27PT
TWO HOLE TERMINAL LUG, COMPRESSION TYPE #6 AWG (BURNDY), P/N YA28L-2TC38
TWO HOLE TERMINAL LUG, COMPRESSION TYPE #2 AWG (BURNDY)
TWO HOLE TERMINAL LUG, COMPRESSION TYPE #2/0 AWG (BURNDY)
#2 AWG INSULATED COPPER WIRE (GREEN)
#2/0 AWG BARE STRANDED COPPER WIRE
DISTRIBUTION PATHWAYS
CABLE TRAY 215mm W x 90mm H x 2.4M LENGTH, C-PROFILE, (ABAHSAIN), P/N 364-215SL-2.44M

COUPLING BAR, 230mm x 90mm, (ABAHSAIN), P/N C-02CS-90mm


BOLT ZINC PLATED MILD STEEL (ABAHSAIN), P/N E-144-1/4" x 5/8"
U-SHAPE FITTING, HDGAF (ABAHSAIN), P/N AB-288-3/8" HDG
BLIND END 304mm RADIUS, 215mmW (ABAHSAIN), P/N C-364-215 BE
FITTINGS FLAT TEE 300mm RADIUS, 215mmW (ABAHSAIN), P/N 364-215-FT-3
90 DEGREES HORIZONTAL ELBOW 300mm RADIUS, 215mmW (ABAHSAIN), P/N 364-215-9F-3
BOX CONNECTOR, 215mm (ABAHSAIN)
EMT CONDUIT 1" DIAMETER x 10' LONG
COUPLING, 1" DIAMETER, COMP TYPE
CONNECTOR, 1" DIAMETER COMP TYPE
CONDUIT STRAP, 1" DIAMETER GALVANIZED
ADJUSTABLE CLEVIS HANGER 1" DIAMETER ABAHSAIN
BUSHING END, 1" DIAMETER CAST ALUMINUM
LOCKNUT BONDING, 1" DIAMETER RACO
ALL THREADED ROD 3/8" x 10'L, (ABAHSAIN) P/N H-104-3/8" (M10)
ANCHOR MASONRY 3/8" x 2"L, (CPI), P/N 20067-001
STD HEX NUT 3/8" (ABAHSAIN)
HEX HEAD CAP SCREW, 3/8" X 1-1/2" (ABAHSAIN)
FLAT WASHER, 3/8", STEEL (ABAHSAIN)
LOCK WASHER, 3/8" (ABAHSAIN)
SQUARE BOX COVER 4" x 4" x 1/2", RACO
OUTLET BOX, 4" x 4" x 2-1/8"
INSTALLATION, TESTING, COMMISSIONING
NEW 13.8KV SUBSTATION NO. XX2
SINGLE MODE FIBER CABLE 24 STRANDS (ITU-T-G.652D)
IES NETWORK ACCESS SWITCH 7 PORT POE+ SWITCH WITH PREMIUM LICENSE, LOOSE TUBE
FILLED, NON-METALLIC, INCLUDING TERMINATION ACCESSORIES.
TRANSMISSION EQUIPMENT WITH ANALOG TELEPHONE LINE AND ETHERNET SIGNAL
FXS CONVERTER
FXO CONVERTER
24 PORT FIBER OPTIC PATCH PANEL INCLUDING ACCESSORIES

# Saudi Aramco: Confidential


OUTDOOR TYPE TELEPHONE HANDSET WITH, OUTDOOR TYPE ENCLOSURE OUTDOOR RATED
UP TO +65 DEG C
1.2 M (D) X .46 M (W) X 17,000 M (L) FIBER OPTIC TRENCH
CATHODIC PROTECTION - WIRELESS REMOTE MONITORING UNIT
Almulhim, Khalid Y:
MECHANICAL
The of this item and
AHbeneathe
CRUDEitSCRAPER
should be LAUNCHER; 42" LINE X 48" BARREL (INSTRUMENTED SCRAPER TRAP) W/
MOTORORIZED LOADING TRAY
"7" in order to ensure
consistency.
AH CRUDE SCRAPER RECEIVER; 42" LINE X 48" BARREL (INSTRUMENTED SCRAPER TRAP) W/
MOTORORIZED LOADING TRAY
2 TON JIB CRANE FOR SCRAPER LAUNCHER / RECEIVER; MOTORIZED PILLAR MOUNTED AT JIB
CRANE
TREATED GAS SCRAPER LAUNCHER; 18" LINE X 22" BARREL (INSTRUMENTED SCRAPER TRAP)
W/ MANUAL LOADING TRAY
TREATED GAS SCRAPER RECEIVER; 18" LINE X 22" BARREL (INSTRUMENTED SCRAPER TRAP) W/
MANUAL LOADING TRAY
1 TON JIB CRANE FOR SCRAPER LAUNCHER / RECEIVER ,MANUAL PILLAR MOUNTED

CONDENSATE SCRAPER LAUNCHER; 10" LINE X 12" BARREL (INSTRUMENTED SCRAPER TRAP)

CONDENSATE SCRAPER RECEIVER; 10" LINE X 12" BARREL (INSTRUMENTED SCRAPER TRAP)

COLLECTION VESSEL (ID: 1300 mm (4’-3”) x T/T: 7800 mm (25’-7”) FOR SCRAPER RECEIVER AT JT

CRUDE OIL SURGE RELIEF TANKS; 25000 BBL


SRS TANK TRANSFER PUMPS; 750 USGPM
OILY WATER SUMP PUMPS (NORMAL FLOW) VERTICAL PUMPS
(Capacity: 200 USGPM)
OILY WATER SUMP PUMPS (NORMAL FLOW) VERTICAL PUMPS
(Capacity: 1000 USGPM)
PORTABLE FIELD PUMP FOR SRS TANK CLEANING (for T&I) (Direct Acting Reciprocating)

# Saudi Aramco: Confidential


Unit Unit Rate (SR)
ES

Unit
LM
SM
CM
MT
KG
SYS
KT
CN
LOT
LT
PC
PK
PR
RO
EA
Almulhim, Khalid Y:
Please state here what
does "WW" stand for
items like Item 5.8.4.1

Unit Unit Rate (SR)

CM

CM
CM
CM

CM

# Saudi Aramco: Confidential


CM
CM
CM
SM
SM
SM
SM
SM
CM

SM

CM
CM
CM
CM

CM

SM
SM
SM
SM
SM

CM
CM

# Saudi Aramco: Confidential


CM
CM

CM

SM

LM
EA
EA

LM
EA
EA

MT
MT
MT

MT
MT

# Saudi Aramco: Confidential


SM
SM

LM

KG

KG

KG

KG

KG
SM
LM
LM
LM

# Saudi Aramco: Confidential


LM

LM

LM

LM

LM

LM

LM

# Saudi Aramco: Confidential


LM

LM

LM

LM

LM

LM

LM

LM

LM
LM
LM
LM
LM
LM
LM
LM
LM
LM
LM
LM

LM
LM

LM

LM

LM

LM

# Saudi Aramco: Confidential


LM

LM

LM

LM
LM
LM

LM
LM

LM

LM

LM

LM

LM

LM

LM

LM

LM

# Saudi Aramco: Confidential


LM

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

# Saudi Aramco: Confidential


EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

# Saudi Aramco: Confidential


EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

# Saudi Aramco: Confidential


EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

# Saudi Aramco: Confidential


EA

EA

EA

EA
EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA
EA

EA

EA

# Saudi Aramco: Confidential


EA

EA

EA

EA
EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

# Saudi Aramco: Confidential


EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

# Saudi Aramco: Confidential


EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

# Saudi Aramco: Confidential


EA

EA
EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

# Saudi Aramco: Confidential


EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

# Saudi Aramco: Confidential


EA

EA
EA
EA
EA

EA
EA

EA

EA

EA

EA
EA
EA
EA
EA
EA
EA
EA

EA
EA
EA
EA
EA
EA
EA

EA
EA

# Saudi Aramco: Confidential


EA
EA
EA
EA
EA
EA
EA
EA
EA
EA

EA

EA

EA

EA

EA

EA

M
M

EA

EA

EA

# Saudi Aramco: Confidential


EA

# Saudi Aramco: Confidential


M

EA
EA
EA
EA

# Saudi Aramco: Confidential


EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA

EA

EA

EA

EA

EA

EA

# Saudi Aramco: Confidential


EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

# Saudi Aramco: Confidential


EA

EA

EA

EA

EA

EA

EA

# Saudi Aramco: Confidential


EA

EA

LM
LM
LM
EA

EA

EA
EA
EA

# Saudi Aramco: Confidential


LM
LM

LM
LM

LM
LM
LM

LM

# Saudi Aramco: Confidential


EA
SET

EA

LM

EA

LM

EA

EA

EA
EA

EA

# Saudi Aramco: Confidential


SET

SET

LM
LM
LM

LM

LM
LM
LM
LM
LM

LM

LM

LM

LM

LM

LM

LM

LM

# Saudi Aramco: Confidential


LM

LM

LM

LM

LM

LM
LM
LM

LM
EA
EA
EA
EA
EA
EA
EA
EA
EA

LM
LM
LM
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA

# Saudi Aramco: Confidential


EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
LM
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA

EA

# Saudi Aramco: Confidential


EA

LM
LM
EA
EA
EA
LM
EA
EA
EA
EA
EA

EA
EA
LM
EA

EA
EA
EA
LM
LM
EA
EA
EA
EA
EA
EA
EA
LM
EA
EA

# Saudi Aramco: Confidential


EA
EA
EA

Almulhim, Khalid Y:
Please state at the
WW description above what
"WW" stands for.

EA

EA

EA

EA

EA

# Saudi Aramco: Confidential


EA

EA

EA

EA
EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

# Saudi Aramco: Confidential


EA
EA

EA

EA

EA
EA

PC
MT
CN
CN
EA
RO

EA

RO

EA

EA

EA
EA
EA
EA
EA

EA
KG
CN
CN
CN
PK
PK
EA

EA

# Saudi Aramco: Confidential


EA

EA

EA
MT
MT
MT
MT

MT

EA

EA

RO

EA

EA

EA

EA

EA

EA
EA
EA
EA

EA

EA

EA
EA
LM
EA

EA

KT
KT

PR

EA
EA

EA

# Saudi Aramco: Confidential


EA

EA
EA

EA
EA
EA
EA
EA
LM
LM

EA

PR
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
LOT

EA

EA
EA
EA
LT

# Saudi Aramco: Confidential


EA

LT
LT

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA
EA

EA

EA

EA

# Saudi Aramco: Confidential


COMPENSATION FOR CHANGES
LABOUR UNIT RATES

ITEM. JOB TITLE Unit


DESIGN PERSONNEL
1 Senior / Lead Engineer HR
2 Discipline Engineer HR
3 Control / ESD Systems Engineer HR
4 Control / ESD Specialist Engineer HR
5 Civil/Structural Engineer HR
6 Process Engineer HR
7 Mechanical Engineer HR
8 Electrical Engineer HR
9 Piping Engineer HR
10 Fire Detection Specialist Engineer HR
11 Fire Protection Specialist Engineer HR
12 Communication Engineer HR
13 Senior Designer HR
14 Designer HR
15 Senior Draftsman HR
16 Project Manager - Design HR
17 Project Control Manager HR
18 Purchasing Manager HR
19 Engineering Manager HR
20 Interface Manager HR
21 QA/QC Manager HR
22 QA/QC Supervisor HR
23 Principal Engineer HR
24 Consultant Engineer HR
25 Supervising Engineer HR
26 Senior Project Engineer HR
27 Project Engineer HR
28 Engineer (Mechanical - Vessels) HR
29 Engineer (Mechanical, Fire Alarm & Detection) HR
30 Engineer (Electrical) HR
31 Engineer (Relay & Protection) HR
32 Engineer (Civil/Structural) HR
33 Engineer (Instrumentation/Automation) HR
34 Engineer (Distributed Control Systems) HR
35 Engineer (Process) HR
36 Engineer (QA/QC) HR
37 Engineer (Piping) HR
38 Scheduler HR
39 Design Specialist HR
40 Supervising Designer HR

# Saudi Aramco: Confidential


41 Drafting Coordinator HR
42 CADD Operator HR
43 CADD Coordinator HR
44 Draftsman HR
45 Procurement / Material Specialist HR
46 Material Coordinator HR
47 Technical Writer HR
48 ETAP/CYME Specialist Engineer HR
49 Commissioning/Start-Up Specialist HR
PROCUREMENT PERSONNEL
50 Buyer HR
51 QA/QC Engineer HR
52 Senior Inspector HR
53 Inspector (Critical coating, NACE Level III) HR
54 Inspector (Vendor and Manufacturer Locations) HR
55 Expediter HR
56 Traffic Coordinator HR
57 Senior Materials Engineer HR
58 Materials Engineer HR
59 Materials Control/Coordinator HR
60 Spare Parts Coordinator HR
SUPPORT PERSONNEL
61 Senior Secretary HR
62 Secretary HR
63 Document Control Clerk HR
64 Clerk HR
SKILLED
65 General Foreman HR
66 Craft Foreman - Structural HR
67 Craft Foreman - Civil HR
68 Craft Foreman - Piping HR
69 Craft Foreman - Mechanical HR
70 Craft Foreman - Electrical HR
71 Craft Foreman - Instrumentation HR
72 Craft Foreman - HVAC HR
73 Plumber HR
74 Pipefitter HR
75 Certified Pipe Welder HR
76 Certified Structural Welder HR
77 Electrical Technician HR
78 Instrument Technician HR
79 Stress Relieving Technician HR
80 Telephone Technician HR
81 HVAC Technician HR
82 NDT Tech-ASNT-Level I HR

# Saudi Aramco: Confidential


83 NDT Tech-ASNT-Level II HR
84 NDT Tech-ASNT-Level III HR
85 Ironworker HR
86 Carpenter HR
87 Sandblaster HR
88 Certified Painter HR
89 Rigger-Level I HR
90 Rigger-Level II HR
91 Rigger-Level III HR
92 Concrete Finisher HR
93 Insulator HR
94 Certified Medium Voltage Cable Splicer HR
95 Certified High Voltage Cable Splicer HR
96 Fibre Optic Cable Splicer HR
97 Sheet Metal Worker HR
98 Rebarman HR
99 Rodman HR
100 Boilermaker HR
101 Labor Foreman HR
102 Laborer HR
103 Work Permit Receiver HR
104 Safety Officer HR
105 Safety Manager HR
106 Civil Foreman HR
107 Electrical Foreman HR
108 Instrument Foreman HR
109 Mechanical Foreman HR
110 Piping Foreman HR
111 Surveyor Foreman HR
112 QA/QC Inspectors HR
113 Certified Welder - Aluminum HR
114 Electrician HR
115 Painter HR
116 Millwright HR
117 Insulator HR
118 Sheet Metal Worker HR
119 Mason HR
120 Grinder HR
121 Skilled Craftsman (General) HR
122 Scaffolding Supervisor HR
123 Scaffolder HR
124 Surveyor HR
125 Mechanical Technician HR
126 Commissioning / Precommissioning Technician HR
TECHNICAL

# Saudi Aramco: Confidential


127 Commissioning Manager HR
128 Superintendent - Civil HR
129 Superintendent - Piping HR
130 Superintendent - Mechanical HR
131 Superintendent - Electrical HR
132 Superintendent - Instrumentation HR
133 Trainer HR
134 Senior Designer HR
135 Designer HR
CADD Operator with associated work station “Rate HR
136 includes complete CADD Systems inclusive of all required
2D and 3D equipment and consumables.”
137 Draftsman HR
138 Commissioning and Start-Up Supervisor HR
139 Telecom Technician HR
140 Certified Functional Safety Expert (CFSE/CFSP) HR
141 Civil Engineering Consultant HR
142 Mechanical Engineering Consultant HR
143 Piping Engineering Consultant HR
144 Electrical Engineering Consultant HR
145 Instrumentation Engineering Consultant HR
VENDOR REPRESENTATIVES
146 Control System and Subsystem Representative HR
147 DCS Representative HR
148 ESD Representative HR
149 VMS Representative HR
150 Static Mech. Equipment Representative HR
151 Rotating Mech. Equipment Representative HR
152 Mechanical Representative HR
153 Control Representative HR
154 Electrical Representative HR
Power Management System/ Power System Automation HR
155
Representative
156 Buckling Pin Valve Representative HR
157 Protection / Relay System Representative HR
158 Fire / Gas Detection System Representative HR
159 Switchgears/MCC Representative HR
160 Power Transformer Representative HR
161 Gas Insulated Switchgear 230KV Representative HR
Instrumentation (level, pressure, flow, temperature, HR
162 vibration monitor, gas detector,gauges, deluge valves)
Representative
Fire Monitors, hydrants, hose reels, water spray nozzles, HR
163
extinguishers etc Representative
164 Communication Equipment Representative HR

# Saudi Aramco: Confidential


165 Pumps Representative HR
166 Surge Relief Skid Representative HR
167 Solar System Representative HR
Commissioning and Start-Up Assistance - Labor
168 Pipe Fitter HR
169 Electrician HR
170 Instrument and Control Technician HR
171 Labor, Skilled HR
172 Welding Engineer HR
173 Laborer, Non-skilled HR
174 Scaffolder HR
175 General Foreman HR
176 Rigger Level 1 HR
177 Rigger Level 2 HR
178 Rigger Level 3 HR
179 Commissioning & Start Up Specialist HR
180 Commissioning & Start Up Manager HR
181 Commissioning & Start Up Lead Engineers HR
182 Discipline Engineer HR
183 Craft Foreman – Civil HR
184 Craft Foreman – Piping HR
185 Craft Foreman – Mechanical HR
Almulhim, Khalid Y:
Commissioning and Start-Up Assistance - Equipment These items should be
moved to III TUR
Equipment
186 Light Vehicle HR
187 Pick-Up Truck-3/4 Ton 4 x 4 HR
188 Light Trucks HR
189 Flatbed Truck- 10 Tons HR
190 Flatbed Truck C/W Crane - 3 Tons HR
191 Tankers HR
192 Vacuum - 22700 Liters (6,000 GAL) HR
193 Cranes HR
194 18 Tons - Grove or Equivalent HR
195 35 Tons - Grove or Equivalent HR
196 55 Tons - Grove or Equivalent HR
197 Compressors and Tools HR
198 Diesel-385 CFM w/Filter and Oiler ACC w/100 ft hose HR
199 Diesel-1200 CFM w/Filter and Oiler ACC w/100 ft hose HR
Portable Fan Blower/Exhauster, 11,000 CFM and 100 ft. of HR
200
hose
201 Pumps HR
202 Bumble Bee (Submersible) w/100 ft hose HR
Injection Pump, Chemical -Complete with valves, gauges HR
203
and hoses, Connections
204 Welding/Cutting Equipment HR

# Saudi Aramco: Confidential


205 Diesel - 400 AMPS w/200 ft of Leads HR
Tig Welding Set complete with accessories including but HR
206
not limited to gas.
207 Floodlight/LTG Equipment HR
208 Portable Diesel Light Tower, 5 to 9 Kw HR
209 Portable Diesel Light Tower, 10 to 25 kW HR
210 Portable Diesel Light Tower, 26 to 50 kW HR
211 Pile Driving Equipment HR
212 Concrete Drilled Pile Equipment w/a accessories HR
213 Generator Sets Complete with Control Panel, Tanks HR
214 10kW HR
215 100- 150 kW HR
216 Tools / Equipment Misc. HR
Torque Wrenches 8000 PSI with Full Range Sockets ¾" HR
217
Drive
Impact Wrenches W' Drive with full range of Sockets HR
218
(lmperial1-3/8" to 4-3/4" Metric 41 mm- 135 mm)
219 Chain Hoist (up to 1-1/2 tons) HR
220 Portable Drill with Magnet Base HR
221 Electric Power Tools HR
Air Mover (Explosion Proof) 5200 CFM w/100 ft. Flexible HR
222
Hose and Couplings
Commissioning and Start-Up Assistance - Vendor
Assistance
223 PAS Hardware Engineer HR
224 PAS Hardware Technician HR
225 PAS Software Engineer HR
226 PAS System Engineer HR
227 Rotating Equipment Engineer HR
228 Static Mechanical Engineer Technical Representatives HR
229 Vendor Representative for Nano Filtration Package HR
Vendor Representative for Emergency Diesel Generator HR
230
Package
231 Vendor Representative for Air Compressor Package HR
232 Electrical Equipment Technical Representatives HR
233 Vendor Representative for Air Dryer Package HR
234 Vendor Representative for Nitrogen Package HR
235 Vendor Representative for Large Motors HR
236 Vendor Representative for Vibration systems HR
237 Vendor Representative for Large Pumps >500 kW HR
238 Vendor Representative for Pumps <500 kW HR
239 Vendor Representative HVAC HR
240 Vendor Representative ESD HR
241 Vendor Representative Analyzers HR
242 Vendor Representative 13.8kV Transformers HR

# Saudi Aramco: Confidential


243 Vendor Representative 34.5kV Transformers HR
244 Vendor Representative 115kV Transformers HR
HR
245 Vendor Representative 115kV switchgear / circuit breakers
246 Vendor Representative Power System Automation HR
247 Vendor Representative Control and On/Off Valves HR
248 Vendor Representative UPS and DC System HR
HR
249 Vendor Representative Switchgears & Protection Relays
Vendor Representative Guided Wave Radar HR
250
Instrumentation
Vendor Representative for Free Space Radar HR
251
Instrumentation
252 Vendor Representative for security systems HR
253 Vendor Representative for chemical dosing systems HR
Vendor Representative for Continues Emission Monitoring HR
254 System CEMS analyzer / Predictive Emission Monitoring
System PEMS.
255 Vendor representative for Paging System. HR
256 Vendor representative for Data Network HR
257 Vendor representative for CCTV system HR
258 Vendor representative for Cable TV system HR
259 Vendor for TETRA Radio infrastructure (EADS). HR
260 Vendor representative for security IDAS system HR
Additional resources
261 Cable Splicer – Foreman HR
262 Carpenter - Finish HR
263 Carpenter - Foreman HR
264 Carpenter - Rough HR
265 Construction Engineers HR
266 Construction General Foreman HR
267 Construction Manager HR
268 Control Systems Engineer HR
269 DCS Technician HR
270 Electrical/Instrument Engineer HR
271 Electrician - Craftsman HR
272 Fireproofer - Craftsman HR
273 Fireproofer - Foreman HR
274 Instrument Fitter HR
275 Insulator - Craftsman HR
276 Insulator - Foreman HR
277 Iron Worker – Craftsman HR
278 Laborer - Foreman HR
279 Mason - Craftsman HR
280 Mason - Foreman HR

# Saudi Aramco: Confidential


281 Mechanical/Piping Engineer HR
282 Millwright - Foreman HR
283 Millwright - Mechanic HR
284 Painter - Craftsman HR
285 Painter – Foreman HR
286 Pipefitter - Craftsman HR
287 Pipefitter - Foreman HR
288 Plasterer - Craftsman HR
289 Plasterer - Foreman HR
290 Plumber - Craftsman HR
291 Plumber - Foreman HR
292 Safety Officer/Supervisor HR
293 Certified Scaffolding Inspector HR
294 Sheet Metal Worker - Craftsman HR
295 Sheet Metal Worker - Foreman HR
296 Site Superintendent HR
297 Surveyor - Instrument Man HR
298 Surveyor - Party Chief HR
299 Welder - Foreman HR
300 Certified Welder – Structural HR
301 Asphalt Worker HR
302 Cable Splicer – Helper HR
303 Carpenter - Helper HR
304 Concrete - Helper HR
305 Electrician - Helper HR
306 Fireproofer - Helper HR
307 Instrument helper HR
308 Insulator - Helper HR
309 Ironworker – Helper HR
310 Laborer - General HR
311 Mason - Helper HR
312 Millwright - Helper HR
313 Painter - Helper HR
314 Pipefitter - Helper HR
315 Plasterer - Helper HR
316 Plumber - Helper HR
317 Pot Fireman/Tarman HR
318 Project Manager HR
319 QA/QC Engineers HR
320 Gritblaster HR
321 Sheet Metal Worker - Helper HR
322 Surveyor - Assistant HR
323 Surveyor - Chainman HR
324 Secretary / Document Controller HR
325 Health and Safety Coordinator HR

# Saudi Aramco: Confidential


326 Mechanical - Foreman HR
327 Welding QA/QC HR
328 Mechanical QA/QC HR
329 Electrical QA/QC HR
330 Instrument QA/QC HR
331 Permit Receiver HR
332 Supervisor HR
333 Structure - Foreman HR
334 Rigging - Foreman HR
335 Architect, Building and Structural Engineer HR
336 Civil Engineer HR
337 PCS Software Engineer HR
338 PCS Hardware Engineer HR
339 Stress Relieving Foreman HR
340 Hydroblaster HR
341 Lagger HR
342 Heavy Vehicle Driver HR
343 Light Vehicle Driver HR
344 Safety Fire Watch/Hole Watch HR
345 Flagman HR
346 Fabricator - Structural Steel HR
347 Machinist HR
348 Certified Welding Inspector HR
349 Mechanical Inspector HR
350 Electrical Inspector HR
351 Instrument Inspector HR
352 Telecommunication Foreman HR
353 Mechanical Fitter HR
354 Lineman HR
355 Cable Puller HR
356 Rigger Helper HR
357 Scaffolder QA/QC HR
358 Field Engineer HR
359 Nurse HR
360 Quantity Surveyor HR
361 Sr. Quantity Surveyor HR
362 Janitor HR

All labor rates shall be considered with small tools and instruments required to perform job

# Saudi Aramco: Confidential


Unit Rate (SR)

# Saudi Aramco: Confidential


# Saudi Aramco: Confidential
# Saudi Aramco: Confidential
# Saudi Aramco: Confidential
Almulhim, Khalid Y:
These items should be
moved to III TUR
Equipment

# Saudi Aramco: Confidential


# Saudi Aramco: Confidential
# Saudi Aramco: Confidential
# Saudi Aramco: Confidential
equired to perform job

# Saudi Aramco: Confidential


EQUIPMENT RATES

Item Equipment Description Unit Unit Rate (SR)


LIGHT VEHICLE
1 Car (sedan) HR
2 Pick-up Truck ½ Ton HR
3 Pick-up Truck ¾ Ton HR
4 Pick-up Truck, Crew L-200 HR
5 Pick-Up Truck - 1 Ton 4 x 4 HR
6 1 ton extended cab 4 door HR
7 Carry All - 1/2 Ton 4X2 HR
8 Carry All - 3/4 Ton 4X2 HR
9 3/4 ton extended cab 4 door HR
10 4x4 Crew Car - 3/4 Ton HR
11 Pick-Up (2 X 2) HR
12 Pick-Up Truck - ½ Ton HR
13 Bus HR
14 Ambulance HR
LIGHT TRUCKS
15 Flatbed Truck - 10 Tons HR
16 Flatbed Truck C/W Crane - 3 Tons HR
17 Boom Truck with crane 2 ton HR
18 Fuel / Water Truck, 2000-4000 Gallons HR
19 Fuel / Water Truck, 5000-10000 Gallons HR
20 Flatbed Truck - 2 Ton HR
21 Flatbed Truck - 5 Ton HR
22 Flatbed Trailer 40 ft. bed HR
HEAVY DUTY TRUCK
23 Dump Truck - 5 C.M. HR
24 Dump Truck - 20 C.M. HR
25 Tractor Unit - 4 x 2 HR
26 Tractor Unit - 6 x 4 HR
27 Trailer, 25 Ton with tractor HR
28 Trailer, 30 Ton with tractor HR
29 Flat Bed Trailer (30 T) HR
30 Heavy Haul Trailer (Cap. 200-250 Ton) with Operator & Crew HR
31 4x4 A-Frame Truck 6 Ton HR
32 Steel wheeled roller HR
33 Rubber tired roller HR
34 Excavator HR
35 Boom Truck (2-8 Ton) HR
36 Bucket Truck, Hi-Ranger w/ double Bucket HR
37 Compactor Vibratory Roller 10 Tons HR
38 Compactor Vibratory Roller 20 Tons HR
39 Compactor Trench Roller Self-propelled - 2 Tons HR
40 Concrete Pump Truck 60 CM/H HR
41 Dump Belly (Up to 30 CY) HR
42 Dump Truck - 12 CY HR
43 Dump Truck - 16 CY HR
44 Dump Truck - 20 CY HR
45 Dump Truck - 30 CY HR
46 Dump Truck - 6 CY HR
47 Dump Truck 15 Cubic Meters HR
48 Flat Bed (100 Ton) HR
49 Flat Bed (50 Ton) HR
50 Fuel/Water Truck, 2000-4000 Gallons HR
51 Manlift Bucket Truck HR

# Saudi Aramco: Confidential


52 Heavy Duty Trucks HR
53 Stakeside - 1 Ton HR
54 Water Truck with pump 1000 GAL HR
55 Water Truck with pump 6000 gallon HR
56 Water Truck with pump 8000 gallon HR
57 Water Truck with pump 10,000 gallon HR
58 Crude Oil Tanker 6000 gallon HR
59 Fork Lift - 2 ton HR
60 Fork Lift - 5 ton HR
61 Fork Lift 7.5 ton HR
62 Fork Lift - 10 ton HR
63 Fork Lift - 20 ton HR
64 Highway Haul Truck, 3-6 T HR
65 Highway Haul Truck, 7-15 T HR
66 Highway Truck - 20 Ton HR
67 Highway Truck - 30 Ton HR
68 Highway Truck - 6 Ton HR
69 Pipelayer/Sideboom HR
70 Roller, Self Propelled – 7 Ton HR
71 Sanitary Water Disposal Truck (3000 Gals) HR
72 Spreader, Asphalt 3 meters HR
73 Spreader, Oil - 2000 Gals. HR
74 Stakebed 1 ton HR
75 Street Sweeper, Vacall, 6x6 HR
76 Transformer Termination Equipment HR
77 Truck Tractor - 200 Ton HR
78 Truck Tractor - 100 Ton HR
79 Truck Tractor - 80 Ton HR
80 Truck Tractor - 50 Ton HR
81 Truck Tractor - 30 Ton HR
82 Vacuum Tank Truck w/ pump 10,000 Gals. HR
83 Vacuum Tank Truck w/ pump 5000 Gals. HR
84 Vacuum Tank Truck w/ pump 8000 Gals. HR
85 Air Tract Drill and Compressor complete with 1" to 1-1/2" Drill Steel HR
86 Bulldozer CAT D6 or SAUDI ARAMCO approved equivalent (with Blade) HR
Bulldozer CAT D7 or SAUDI ARAMCO approved equivalent (with Side Boom)
87 HR
Bulldozer CAT D8 or SAUDI ARAMCO approved equivalent (with heavy duty
88 HR
winch and single point ripper)
Bulldozer CAT D9 or SAUDI ARAMCO approved equivalent (with heavy duty
89 HR
winch and single point ripper)
90 Grader CAT M Series or SAUDI ARAMCO approved equivalent HR
TANKERS
91 Water - 37,800 Liters with Pump (10,000 GAL) HR
92 Vacuum -Water- 22,700 Liters (6,000 GAL) HR
93 Tanker, Crude Oil - 2000 Gals. HR
94 Tanker, Crude Oil - 6000 Gals. HR
95 Tanker, Water - 4000 Gals. HR
96 Tanker, Water - 5000 Gals. HR
97 Tanker, Water - 6000 Gals. HR
TRAILERS
98 Lowboy - 200 Tons with Tractor HR
99 Stake Bed truck 2 ton HR
100 Dolly, Pipe HR
101 Tractor and Trailer (40 feet) HR
102 Trailer - 100/150 Ton HR
103 Trailer - 45 Ton HR
104 Trailer Flatbed - 15 Ton HR

# Saudi Aramco: Confidential


105 Trailer Flatbed - 4W (6 Ton) HR
106 Trailer, Lowboy - 40 Ton HR
107 Trailer, Lowboy - 60 Ton HR
108 Trailer, Water Tank 10000 Gals HR
109 Trailer, Water Tank 2000 Gals. HR
110 Trailer, Water Tank 5000 Gals. HR
FRONT END LOADERS
111 Bobcat HR
112 Backhoe/Excavator JCB HR
113 Cat D9 or Equivalent HR
114 Cat 980 or Equivalent HR
115 Cat with Rock Drill HR
116 Front loader / backhoe, 1 Cu. Meter HR
117 Backhoe - 5 CM HR
118 Backhoe - 1/2 CM HR
119 Backhoe - 3/4 CM HR
120 Front End Loader - 1 3/4 CY HR
121 Front End Loader 3 CY HR
122 Front End Loader 5 CY HR
123 CAT 950 or SAUDI ARAMCO approved equivalent HR
124 CAT 966 or SAUDI ARAMCO approved equivalent HR
125 CAT 980 or SAUDI ARAMCO approved equivalent HR
COMPACTORS
126 Vibratory Plate HR
127 Jumping Jack HR
128 Trench Roller/Compactor, 600 kg HR
129 Trench Roller - Self Propelled - 2 Tons HR
130 Sheepsfoot Roller 2 x 60” HR
131 Vibratory Roller - 20 Tons HR
CRANES
Includes minimum of two (2) sets of rigging for each crane comprising a
total of eight (8) slings and eight (8) shackles per crane, lengths and
strengths compatible with crane capacity and reach.

132 80 Tons – Grove or Equivalent HR


133 200 Tons – Grove or Equivalent HR
134 300 Tons – Grove or Equivalent HR
135 400 Tons – Grove or Equivalent HR
136 600 Tons – Grove or Equivalent HR
137 800 Tons – Grove or Equivalent HR
138 Certified crane operator HR
139 Crane (100 to 150 Ton) HR
140 Crane, Hydraulic Boom 20 Ton HR
141 Crane, Hydraulic Boom 30 Ton HR
142 Crane, Hydraulic Boom 40 Ton HR
143 Crane, Hydraulic Boom 60 Ton HR
144 Crane, Self Propelled, 30-50 T HR
145 Crane/Crawler - 100 Ton HR
146 Crane/Crawler - 250 Ton HR
147 Crane/Crawler - 30 Ton HR
148 Crane/Crawler - 50 Ton HR
149 Crane/Crawler - 90 Ton HR
150 Crane 800 Tons HR
151 Crane 1200 Tons HR
152 Flat-Bed Truck w/ Uni-Crane (10 Ton) HR
153 Flatbed 3 Ton with Hydraulic Crane and Outriggers HR
COMPRESSORS AND TOOLS
154 Diesel-385 CFM w/Filter and Oiler ACC w/100 ft. hose HR

# Saudi Aramco: Confidential


155 Diesel-1200 CFM w/Filter and Oiler ACC w/100 ft. hose HR
156 Jackhammer and accessories HR
Jackhammer - 65 lbs. min with breaking tools and 100 ft. length hose including
157 HR
coupling
Sandblasting Set - Abrasive blasting pot complete, Hose, Gun, Protective Suit,
158 HR
Hood and 100 ft. of Airline
159 Paint Spraying Set and 100 ft. hose HR
160 Portable Fan Blower/Exhauster, 11,000 CFM and 100 ft. of hose HR
161 Additional 100 ft. length hose for items 10.1/2/3 and 10.4 HR
PUMPS
162 Bumble Bee (Submersible) w/100 ft. hose HR
163 Centrifugal - 4” w/100 ft. Hose HR
164 Pressure Pump (10000 PSI) w/recorder w/100 ft. Hose HR
Additional 100 ft. length of hose and couplings for items 11.1, 11.2, 11.3 and
165 HR
11.4
Injection Pump, Chemical - Complete with valves, gauges and hoses,
166 HR
connections
Wellpoint Dewatering System, 3” header and 6 well points at 10 ft. on center x
167 22 ft. deep, complete with vacuum pump to deliver 5 psi absolute pressure HR

168 Dewatering Pump Inc., Suct. and Disch. Hoses, 2400 Gpm 200 ft 8" hose HR
169 Dewatering Pump Inc., Suct. and Disch. Hoses, 1200 Gpm 200 ft 6" hose HR
Dewatering Pump Inc., Suct. and Disch. Hoses, 600 Gpm 200 ft of 4" hose
170 HR
171 4" Dewatering Pump Hose 100 feet with Quick couplings HR
172 6" Dewatering Pump Hose 100 feet with Quick couplings HR
173 8" Dewatering Pump Hose 100 feet with Quick couplings HR
174 Pump, Dewatering 4”* HR
WELDING/CUTTING EQUIPMENT
175 Diesel - 400 AMPS w/200 ft. of Leads HR
176 Welding Mach., Miler, Mark VIII-2, Electric 8x200 HR
177 Welding Machine Miller, SRH-333, Electric 300A HR
178 Welding Machine Miller, TrBizr 44D, Diesel 300A HR
179 Welding Machine, 100 AMP (Diesel) HR
Tig Welding Set complete with accessories including, but not limited to, gas
180 HR
181 Air Arc Cutting Equipment Set HR
Oxy/Acetylene Cutting Set complete with accessories including, but not limited
182 HR
to, gauges, gases, bottle rack, cutting torch
183 Stress Relief, Heat Blankets and Power Supply HR
184 Grinder, electric – 6 in. HR
FLOODLIGHTS/LTG EQUIPMENT
185 Light Tower (Mobile), 4 x 1000W HR
186 Lights – Portable 2000 Watts with Generator HR
187 Portable Diesel Light Tower, 5 to 9 kW HR
188 Lighting Plant (Generator) 5-6 kW HR
PILE DRIVING EQUIPMENT
189 Pile Driving Hammer, Steam or Air, 4150 ft-lb @225 BPM HR
190 Pile Driving Hammer, Steam or Air, 15,000 ft-lb @ 60 BPM HR
191 Pile Driving Hammer, Steam or Air, 24,450 ft-lb @ 111 BPM HR
192 Diesel Type Hammer, 22,400 ft-lb HR
193 Diesel Type Hammer, 41,300 ft-lb HR
CONCRETE EQUIPMENT
194 Concrete Pump, Truck Mounted, 4” Line, 80’ Boom HR
195 Concrete Mixer, 6 cu ft. HR
196 Ready Mix Truck HR
197 Concrete Vibrator HR
198 Concrete Finisher HR

# Saudi Aramco: Confidential


199 Boring Machine HR
200 Concrete Bucket 3/4 Cubic Yard, Manual HR
201 Concrete Saw 10” HR
202 Concrete Saw for 4” cut HR
PIPING EQUIPMENT
203 WACHS Saw - Travel Cutter w/Chain to 56” HR
204 Chop Saw HR
205 Band saw, electric HR
206 Holiday Detector HR
207 Pipe Cutting/Beveling Machine (up to 48 in. diameter) HR
208 Jack – 10 Tons HR
209 Jack - 50 Tons, Enerpack HR
210 Pipe Cut/Bevel Machine HR
211 Pipe Cutting/Threading Machine HR
212 Bender, Hydraulic, Pipe/Conduit HR
GENERATOR SETS COMPLETE WITH CONTROL PANEL, TANKS
213 Generator Set Diesel, 10 KW, 480V HR
214 Generator Set Diesel, 50 KW, 480V HR
215 Generator Set Diesel, 60 KW, 480V HR
216 Generator Set Diesel, 150 KW, 480V HR
217 Generator Set Diesel, 250 KW, 480V HR
218 Generator Set Diesel, 300 KW, 480V HR
219 Generator Set Diesel, 400 KW, 480V HR
220 Generator Set Diesel, 500 KW, 480V HR
221 Generator Set Diesel, 10 KW, 220V HR
222 Generator Set Diesel, 50 KW, 220V HR
223 Generator Set Diesel, 60 KW, 220V HR
224 Generator Set Diesel, 150 KW, 220V HR
225 Generator Set Diesel, 250 KW, 220V HR
226 Generator Set Diesel, 300 KW, 220V HR
227 Generator Set Diesel, 400 KW, 220V HR
228 Generator Set Diesel, 500 KW, 220V HR
229 Generator Set 5-6 KW (with plug-in for power tools and extension cord) HR
230 Generator Set 10 KW (with plug-in for power tools and extension cord) HR
231 Generator Set 15 KW (with plug-in for power tools and extension cord) HR
232 Generator Set 20 KW (with plug-in for power tools and extension cord) HR
233 Generator Set 35 KW (with plug-in for power tools and extension cord) HR
234 Generator Set 60 KW (with plug-in for power tools and extension cord) HR
235 Generator 100-200 KW (with plug-in for power tools and extension cord) HR
236 Generator 400-600 KW (with plug-in for power tools and extension cord) HR
237 Instrument MA Source Generator HR
TOOLS AND MISC. EQUIPMENT
238 Rebar Bender HR
239 Rebar Shear HR
240 Rebar Tire Roller (7 wheel minimum) HR
241 Torque Wrench with Sockets HR
Impact Wrenches 1/2" Drive with Full range of Sockets (Imperial 1-3/8" to 4-
242 HR
3/4" Metric 41 mm - 135mm)
243 Hydrotest Pressure Recorder with charts HR
244 Chain Hoist (up to 1-1/2 tons) HR
245 Come-A-Long (up to 1-1/2 tons) HR
246 Megger 100V – 2.5 kV HR
247 600 volt, portable, electrical cable megger test set HR
248 5,000 volt, portable, electrical cable megger test set HR
249 100 kV, portable, electrical cable hi-pot test set HR
250 Portable circuit tester, volt/ohm/amp meter HR
251 Portable grounding tester HR
252 Rollers, Cable Pulling (up to 4 in. OD cable) HR

# Saudi Aramco: Confidential


253 Digital VOM Meter HR
254 Line frequency rotation indicator HR
255 Pipe Bending Machine up to 24" (CRC or Equal) HR
256 Roller/Compactor, 10T HR
257 Compactor Vibratory Shoe HR
258 Rubber Tire Roller (7 wheel minimum) HR
259 Sand Blasting Equipment (Complete) HR
260 Hydrostatic Test Pressure Pump with accessories HR
261 Hydrostatic Test Water Fill Pump HR
Hydrostatic Test Pressure Pump, Hand Operated, 3,000 psi, with accessories
262 HR
and manifold
263 Hydrotest Relief Valve and Gauges HR
264 Survey Equipment (Crew Kit) HR
265 Pipe Air Dryers HR
266 Nitrogen Fillings Units complete set with evaporator and operator HR
267 internal clamp 20” HR
268 external clamp 2” to 30” HR
269 Vacuum Tanker-decruding HR
270 Decruding pump HR
271 Scaffolding HR
272 Scissorlift 32” HR
273 Scissorlift 42” HR
274 Alignment clamps for pipe 2” through 12” O.D. HR
275 Analog Volt Ohm Meter (VOM, Simpson 260 or equal) HR
276 Bench Saw 10” HR
277 Bull Wire Rewinder HR
278 Cable Rollers HR
279 Cold Cutting Saw (Wachs) HR
280 Conductor Jointing Machine HR
281 Conduit Bending Machine HR
282 Conduit Threading Machine HR
283 Current / mV Simulator (Transmission 1040 or equal) HR
284 D9 Cat Dozer with Ripper or equal HR
285 D9 Cat Dozer or equal HR
286 Drill Air or Electric Operated HR
287 Drum Roller (15 T Minimum) HR
288 Ductor Tester HR
289 Fluke Digital Multimeter HR
290 Ground Tester HR
291 Grinder 7” Electric HR
292 Hydraulic Dead Weight Calibrator HR
Relay Tester: Omicron CMC 356; Universal Relay Test & Commissioning Tool
293 HR
Non Destructive Equipment (NDE) / Ultrasonic Testing (UT) / Magnetic Particle
294 HR
Inspection (MPI) including test reports
Oxy-Acetylene set with complete accessories, including cylinders and gases
295 HR
296 Personnel Basket HR
297 Pilot Wire HR
298 Plate Tamper HR
299 Pneumatic Calibrator HR
300 Puller HR
301 Instrument Calibrator RIS CL-6000 or equal HR
302 Radial Arm Drill HR
303 Raychem Thermofit Marking System HR
304 Stands for Conductor Reel HR
305 Tamper/Rammer, hand held HR
306 Tensioner HR

# Saudi Aramco: Confidential


307 Test instrument – Multi Amp, 3 phase Current HR
308 Theodorne T-1AE or equal with tripod HR
309 Thermocouple Calibrator (Type J,K,T) HR
310 Travellers/Pulleys HR
311 Wire-Test Telephones HR
OTDR (Optical Time Domain Reflectometer) and associated Communication
312 HR
Test Equipment
313 Hi-Pot Tester up to 115kV with Electrical Cable - Portable HR
314 Adjustable Floor Centers HR
315 Analog VOM (Simpson 260 or equal) HR
316 Hydraulic Hammer for Backhoe HR
317 6 meter long 42" high Self Supporting Barricade with Battery Lights HR
318 Barricades with Lights HR
319 Bender – Pipe/Conduit (Electric) HR
320 Chain Hoist - Up to 1 1/2 Tons HR
321 Chain Hoist - Up to 3 Tons HR
322 Chipping Hammer Elec/Pneumatic HR
323 Cold-Cutting Saw up to 30" pipe and 1" WThk HR
324 Cold-Cutting Saw up to 12" pipe & .75" WThk HR
325 Cold-Cutting Saw up to 18" pipe & 1.5" WThk HR
326 Compactory Vibratory Plate HR
327 Compactor, diesel 6 HP 30x36 plate HR
328 Compactor, Hand (Plate) HR
329 Compactor, hand tampers HR
330 Air Compressor and accessories, 125-175 CFM (with 100 ft. min hose) HR
331 Air Compressor and Accessories, 200-375 CFM (with 100 ft. min hose) HR
332 Air Compressor and Accessories, 600-750 CFM (with 100 ft. min hose) HR
333 Additional 100 ft. length hose including couplings HR
334 Concrete Core Drill and All Accessories (up to 6” dia.) HR
335 Concrete Curb Machine HR
336 Concrete Mixer – 1 CM HR
337 Concrete Mixer – 2 CM HR
338 Concrete Power Finishing HR
339 Concrete Power Trowel HR
Concrete or Asphalt Cutting Saw with Diamond Blades, Target Model 3518 or
340 HR
SAUDI ARAMCO approved equivalent with water pump
341 Concrete Vibrator - Air Operated HR
342 Concrete Vibrator – Electric HR
343 Current/MV Simulator (Transmission 1040 or equal) HR
344 Drill Press - 1 1/4" HR
345 Drill, Radial Arm HR
346 Ductor test equipment HR
347 Electric Grinder, 6" HR
348 Freja Metering and Relay Tester HR
349 Hacksaw, Electric HR
350 Heli-Arc Welding Machine HR
351 Hi potential test equipment HR
352 Hi-Pot Tester HR
353 Hot Stick w/ Tools (1 Lot) HR
354 7.5 kw light plant HR
355 10 kw light plant HR
356 Portable Diesel Light Tower, 5 to 9 KW, explosion proof HR
357 Portable Diesel Light Tower, 10 to 25 KW, explosion proof HR
358 Portable Diesel Light Tower, 26 to 50 KW, explosion proof HR
359 Lighting Plant, 300W HR
360 Lighting, Portable - 2000 Watts HR
361 Lighting, Portable - 4000 Watts HR

# Saudi Aramco: Confidential


Lighting, Portable, Floodlight 1000 Watt, High Pressure Sodium Vapor w/
362 HR
Connection
363 Megger Test Instrument 500V Set with Cable - Portable HR
364 Megger Test Instrument 1000V Set with Cable - Portable HR
365 Multi-Amp test equipment HR
Gas Cutting Rig including Oxygen/Acetylene, with complete accessories
366 HR
including bottle rack, gauges, cutting torch, striker, etc.
367 Paint Spraying Equipment w/ Compressor HR
368 Pedestal Grinder - 6" HR
369 Pedestal Grinder - 12" HR
Threading Machine, Pipe and Bolt Complete with three sets of Dies 1/8"-2"
370 HR
(set), 2-1/4"-4" (set) and 4"-6"
371 Portable Drill w/ Magnet Base HR
372 Post Hole Drilling Machine HR
373 Primary Injector HR
374 Pump, Fill 200 gpm HR
Calibrated hydrotest pump equipment 20 GPH minimum at 6000 PSI complete
375 with fittings, guages, hoses, test charts, deadweight, pressure recorder, set of HR
calibrated relief valves and matching springs
376 Pump, Submersible 200 gpm HR
377 Rebar Bender up to 20 mm HR
378 Rebar Shear Cutter HR
379 Saw, Guillotine (for line size to 56"Ø) HR
380 Saw, Masonry HR
381 Saw, Radial Arm/Table HR
382 Saw, Rotary Hand HR
383 Saw, WACHS or approved equivalent - Travel Cutter with Chain to 56" HR
384 Scaffolding (Bay 6x6x6.5 ft) HR
385 Secondary Conduit Injector HR
386 Sheet Metal Auto Shear HR
387 Sheet Metal Break HR
388 Sheet Metal Cross Breaking Machine HR
389 Sheet Metal for Bending and Cutting Machine HR
390 Sheet Metal Lock Former (Seam Roller) HR
391 Single Post Shoring HR
392 Surveying Equipment HR
393 Tape Machine, Clean 16-26" HR
394 Tape Machine, Clean 8-16" HR
395 Three Phase Injector HR
Tig Welding Machine complete with accessories including, but not limited to,
396 HR
gas
397 Welding Machines - 200 Amp HR
398 Welding Machines - 300 Amp HR
399 Welding Machines - 400 Amp HR
400 Wheatstone Bridge HR
Backfill Tamper (Jumping Jack) Model 441 as manufactured by Ingersoll Rand
401 HR
or SAUDI ARAMCO approved equivalent
Impact wrench, drive 1" with full range of sockets (Imperial 1-1/16" to 3-1/2"
402 HR
metric 27 mm to 80 mm)
Impact wrench, drive 1/2" with full range of sockets (Imperial 1-3/8" to 4-3/4"
403 HR
metric 41 mm to 135 mm)
Impact wrench, drive 1" with full range of sockets (Imperial 1-3/8" to 4-3/4"
404 HR
metric 41 mm to 135 mm)
Abrasive blasting pot complete, CLEMCO model 2048 or SAUDI ARAMCO
405 approved equivalent, including hose, gun, protective suit, hood and 100 ft. HR
hose
Fire Retardant Blanket Material (heavy duty) for shielding Welding Operations.
406 HR
6 sides

# Saudi Aramco: Confidential


Exp proof Portable fan blower/exhauster 2,000 cfm and 200 ft. of Flex Duct 10"
407 HR
Exp Proof Portable fan blower/exhauster 1,000 cfm and 200 ft. of Flex Duct 8"
408 HR
409 Portable fan blower/exhauster 11,000 cfm and 100 ft. of hose HR
Hydraulic Lifting Tool - Enerpac Jack 25 Tons or SAUDI ARAMCO approved
410 HR
equivalent
Hydraulic Lifting Tool - Enerpac Jack 50 Tons or SAUDI ARAMCO approved
411 HR
equivalent
Diaphragm Pump 3" Air Model PDA 300 as manufactured by Ingersoll Rand (or
412 SAUDI ARAMCO approved equivalent) with 100 ft of suction hose and 100 ft. HR
of discharge hose
Centrifugal Pump 4" with 100 ft of suction hose and 100 ft. of discharge hose
413 HR
Centrifugal Pump 6" with 100 ft of suction hose and 100 ft. of discharge hose
414 HR
Submersible Pump with 100 ft. of suction hose and 100 ft. of discharge hose
415 HR
416 Hydrotest Pump with 100 ft of 3/4" hose and 2-Valves. (10,000 psi) 2-gpm HR
417 Theodolite, Tripod and Accessories HR
418 Self-Levelling Level, Tripod and Accessories HR
419 Torque Wrenches 8000 PSI with Full Range Sockets 3/4" Drive HR
420 Transformer/Motor Low Resistance and Power Factor Tester HR
421 Diesel-385 CFM w/Filter and Oiler ACC w/100 ft hose HR
422 Diesel-600 CFM w/Filter and Oiler ACC w/100 ft hose HR
423 Diesel-750 CFM w/Filter and Oiler ACC w/100 ft hose HR
424 Diesel-1200 CFM w/Filter and Oiler ACC w/100 ft hose HR
425 Concrete Drilled Pile Equipment with Accessories HR
Dead Weight Tester, 10,000 psi with Full Set of Weights from 2 lbs to 50 lbs
426 HR
Hydrotest Temperature / Pressure Recorder with Charts minimum of 750 psi
427 HR
rated
Scizzor Lift/Hydraulic Access Platform self propelled 12 meter reach 2-person
428 HR
Scizzor Lift/Hydraulic Access Platform self propelled 8 meter reach 2-person
429 HR
430 Engine Powered, Hydraullic, Auto Tension Sensing Cable Puller HR
431 Instrument Loop Calibrator HR
432 Temperature Bath HR
433 Instrument Calibrators (i.e. Pressure Calibrator, Dead Weight Tester) HR
434 Air Drying Skids 750 SCFM to Dewpoint of -5C HR
435 Hydraulic Flange Spreaders 5 Ton HR
436 SS Ball Pipe Rollers Bottom Flange type capacity each ball 1000 Kg HR
ELECTRIC POWER TOOLS
Air Mover (Explosion Proof) 5200 CFM w/100 ft. Flexible Hose and Couplings
437 HR
438 Additional 100 ft. length of hose and couplings for item 19.1 HR
Threading Machine, Pipe and Bolt Complete with two sets of dies 1/8” - 2” (set)
439 HR
and 2-1/4” - 4” (set) Rigid 300
Threading Machine, Pipe and Bolt Complete with three sets of Dies 1/8” - 2”
440 HR
(set) and 2-1/2”-4” (set) and 4” - 6”
Electric cable puller with capstan and accessories for all cable sizes up to
441 HR
750MCM.
442 Forklift 2 Ton HR
443 Forklift 3 Ton HR
444 Forklift 7 Ton HR
445 Transportation bus (20 passenger). HR
446 Scissor man lift HR

# Saudi Aramco: Confidential


447 Boom man lift HR
448 Construction barricades with battery powered beacons HR
449 Trench plates HR
450 Garbage or Trash Dumpster HR
451 Wire & cable reel jacks HR
452 Hi-Pot Tester (DC) HR
453 Hi-Pot Tester (AC) HR
ROAD EQUIPMENT
454 Barber-Greene (or equal) Asphalt Layer 10 ft wide HR
455 Road Brush - Self Propelled HR
456 Line Marker - Self Propelled HR
457 Asphalt Cutter HR
458 Steel-Wheeled Roller HR
459 Road Grader HR
460 Asphalt Laydown Machine (Barber Greene 6 M Wide or Equiv) HR
461 Asphalt paver HR
OTHER EQUIPMENT
462 Design Office Rent per Unit Month
463 Parking Space per Unit Month
464 Midsize Desktop Computer Month
465 File Server Computer Month
466 Desktop All-in-one Printer Month
467 Network Black/White Copier- Printer Month
468 Network Color Copier-Printer Month
469 Laptop Computer Month
470 Portable Paper Shredders Month
471 Color Network Server Printer Month
472 Scanner Month
473 Copy Machine (D-E size) HR
474 CADD station HR
Monthly rate is defined as an all-inclusive rate to cover CONTRACTOR's direct and indirect costs and all
overhead costs as well as profit. For the purposes of calculating compensation or credit for partial months, the
following formula shall be used:

Daily Rate = Monthly Rate / 30 days

B MISCELANEOUS ITEMS Unit Rate


B1 Desktop Computer, as identified in Sch. B att. IV Month
B2 Laptop Computer, as identified in Sch. B att. IV Month
B3 Licensed Primavera P6, as identified in Sch. B att. IV Month
B4 Licensed Adobe Acrobat Professional, as identified in Sch. B att. IV Month
B5 Licensed Latest Version of ETAP, as identified in Sch. B att. IV Month
B6 Desktop Laser-jet Fax/Scanner/Printer/Copier, as identified in Sch. B att. IV Month
B7 Network Capable Multi-Function Laser Printer, as identified in Sch. B att. IV Month
B8 CellPhones, as identified in Sch. B att. IV Month
B9 Satellite Camp Elements as identified in Sch. B att. IV Month
B10 Satellite Camp Operations, as identified in Sch. B att. IV Month
B11 Satellite office Elements as identified in Sch. B att. IV Month
B12 Satellite office Operations, as identified in Sch. B att. IV Month

C Scaffolds Rate Unit Rate

Initial fourteen (14) calendar day rental (including erecting & dismantling) for Tower
1 scaffold and vertical sided Vessel/column/tank/interior/exterior scaffolds
1.1 Floor level to 15’ high by 6’ wide SFFA

# Saudi Aramco: Confidential


1.2 Greater than 15’ high to 25’ high by 6’ wide SFFA
1.3 Greater than 25’ high to 65’ high by 6’ wide SFFA
1.4 Greater than 65’ high to 105’ high by 6’ wide SFFA
1.5 Greater than 105’ high to 145’ high by 6’ wide SFFA
1.6 Greater than 145’ high to 185’ high by 6’ wide SFFA

Initial fourteen (14) calendar day rental (including erecting & dismantling) for
2 Independent tied scaffold and vertical sided Vessel/column/tank/interior/ exterior
scaffolds
2.1 Floor level to 15’ high by 6’ wide SFFA
2.2 Greater than 15’ high to 25’ high by 6’ wide SFFA
2.3 Greater than 25’ high to 65’ high by 6’ wide SFFA
2.4 Greater than 65’ high to 105’ high by 6’ wide SFFA
2.5 Greater than 105’ high to 145’ high by 6’ wide SFFA
2.6 Greater than 145’ high to 185’ high by 6’ wide SFFA

Initial fourteen (14) calendar day rental (including erecting & dismantling) for Mobile
3 Tower Scaffolds
3.1 Floor level to 21’ high by 6’ wide SFFA

Initial fourteen (14) calendar day rental (including erecting & dismantling) for
4 Suspended Scaffolds
4.1 To 25’ above/below main working level SFWP
4.2 Greater than 25’ to 50’ above/below main working level SFWP
4.3 Greater than 50’ to 100’ above/below main working level SFWP
4.4 Greater than 100’ above/below main working level SFWP

Initial fourteen (14) calendar day rental (including erecting & dismantling) for Cantilever
5 Working Platform Scaffolds
5.1 From main working level to 25’ high SFWP
5.2 Above 25’ to 50’ high SFWP
5.3 Above 50’ to 100’ high SFWP
5.4 Above 100’ high SFWP

Daily rental rate after initial fourteen (14) calendar day period for all types (i, ii, iii, iv,
6 and v) of scaffolds. SF

UNITS DEFINITION
SFFA - is defined as SQUARE FOOT FRONTAL AREA
SFWP - is defined as SQUARE FOOT WORKING PLATFORM
SF - is defined as SQUARE FOOT

END OF ATTACHMENT I TO SCHEDULE "C"