FIR No. JSL-KAN-OGC-92091-FIR-007 Date. 30.04.2021
FIR No. JSL-KAN-OGC-92091-FIR-007 Date. 30.04.2021
FIR No. JSL-KAN-OGC-92091-FIR-007 Date. 30.04.2021
TABLE – 1: LOA Status (Cumulative Qty is accepted qty from Final Visual & Dimensional Inspection)
Ordered
Ordered Previous Today’s Cumulative Balance
Qty
Qty Qty Qty Qty Qty
Sr. combined %
Item Description
No. In Meters In Meters In Meters Completed
In In
(No's of (No's of (No's of In Meters
Meters Meters
Pipe) Pipe) Pipe)
48" Pipe, 20.6 mm WT, API 5L
1 4200 0.000 0.000 0.000 0.000 0.00%
Gr. X70MS / L485MS, PSL2, SAWL
26700
48" Pipe, 20.6 mm WT, API 5L
2 22500 0.000 0.000 0.000 0.000 0.00%
Gr. X70MS / L485MS, PSL2, SAWL
48" Pipe, 23.8 mm WT, API 5L
*** 3 39000
Gr. X70MS / L485MS, PSL2, SAWL
48" Pipe, 23.8 mm WT, API 5L 39670 0.000 398.595 398.595 39271.405 1.00%
*** 4 300
Gr. X70MS / L485MS, PSL2, SAWL
48" Pipe, 23.8 mm WT, API 5L
*** 9 370
Gr. X70MS / L485MS, PSL2, SAWL
48" Pipe, 27.0 mm WT, API 5L
*** 5 60
Gr. X70MS / L485MS, PSL2, SAWL
338 0.000 261.120 261.120 76.880 77.25 %
48" Pipe, 27.0 mm WT, API 5L
*** 8 278
Gr. X70MS / L485MS, PSL2, SAWL
52" Pipe, 28.6 mm WT, API 5L
6 72 72 73.555 0.000 73.555 -1.555 100%
Gr. X70MS / L485MS, PSL2, SAWL
48" Pipe, 34.0 mm WT, API 5L
*** 7 36 36 49.180 11.545 60.725 NIL 100.00 %
Gr. X70MS / L485MS, PSL2, SAWL
16" Pipe, 10.0 mm WT, API 5L
10 60 60 0.000 0.000 0.000 0.000 0.00%
Gr. X70MS / L485MS, PSL2, SAWL
*** - Total Completed % acceptable subject to test results of Mechanical test results of MPQT and RP.
Production Status - For Production status please see on Daily Production report.
Witnessed All WELD tensile test as per ITP Sr.No.B.21- Found meeting the requirements.
Witnessed Guided bend test as per ITP Sr.No.15.A.7- Found satisfactory.
Witnessed visual inspection of inside and outside pipes as per ITP Sr.No. 10.1- No injures surface defect
observed.
Witnessed pipe inspection for the dents as per ITP Sr.No. 10.2- No found dent.
Witnessed radial offset of plate edges as per ITP Sr.No. 10.3- Found satisfactory.
Witnessed misalignment of weld bead as per ITP Sr.No. 10.4- Found within acceptable limit.
Witnessed height of weld bead (inside& outside) as per ITP Sr.No. 10.5- Found within acceptable limit.
Witnessed pipe inspection for the hard spot as per ITP Sr.No. 10.6- No hard spot observed.
Witnessed visual inspection for free from cracks, sweats and leaks as per ITP Sr.No. 10.7- No injures surface
defect observed.
Witnessed visual inspection for lamination as per ITP Sr.No. 10.8- Found satisfactory.
Witnessed weld inspection for undercuts as per ITP Sr.No. 10.9- Found satisfactory.
Witnessed other surface imperfections as per ITP Sr.No. 10.10- Found satisfactory.
Witnessed visual inspection for arc burns as per ITP Sr.No. 10.11- Found satisfactory.
Witnessed wall thickness of pipe as per ITP Sr.No. 11.1- Found within acceptable limit.
Witnessed pipe length as per ITP Sr.No. 11.2- Found within acceptable limit.
Witnessed straightness of pipe as per ITP Sr.No. 11.3- Found within acceptable limit.
Verified during visual inspection for no jointers as per ITP Sr.No. 11.4- Found satisfactory.
Witnessed inside diameter at pipe ends as per ITP Sr.No. 11.5- Found within acceptable limit.
Witnessed outside diameter at pipe body as per ITP Sr.No. 11.6- Found within acceptable limit.
Witnessed out of roundness at pipe end for inside diameter as per ITP Sr.No. 11.7- Found within acceptable limit.
Witnessed out of roundness at pipe body for outside diameter as per ITP Sr.No. 11.8- Found within acceptable
limit.
Witnessed peaking and flat sports at end at pipe ends as per ITP Sr.No. 11.9- Found acceptable limit.
Witnessed weight of pipes as per ITP Sr.No. 11.10- Found within acceptable limit.
Witnessed bevel angle and root face as per ITP Sr.No. 12.1- Found within acceptable limit.
Witnessed end squareness as per ITP Sr.No. 12.2- Found within acceptable limit.
Witnessed inside and outside weld bead grinding before MPI as per ITP Sr.No. 12.3- Found within acceptable
limit.
For Regular Production Pipe Size: 48” OD X 34 MM WT, 48” OD X 27 MM WT & 48” OD X 23.80 MM WT,
Surveillance visual & dimensional inspection of incoming plats as per ITP Sr. No. 2.1 – Found within tolerance.
Reviewed reports for control Chemical analysis as per ITP Sr.No.2.2 - Found within acceptable limit.
Reviewed reports for control Tensile test as per ITP Sr.No.2.3 - Found meeting the requirements.
Note: -
Reviewed raw material test certificates for plates – Found meeting the requirements except below point
incorporate in RMTC. (Continuous casting method not specified)
As per Physical plate Marking verification and RMTC provided data some points not match (Heat No. 6 digit after
4 more numbers are available and as per marking RMTC number not match with RMTC) - same as conformation
required by plate manufacturer and client concern required.
27mm WT – RPQT Done Sampling Not Completed, testing balance for repair approval.
Identification: Nil
Remark: Photographs not attached due to USB access not permitted to JSL premises.
Attending Inspectors: Kaushikkumar Patel & Nimesh Patel (Day Shift) & Mohit Solanki (Night Shift)
Category: (1) Accepted, (2) Conditionally Accepted, (3) Re-Inspection Required, (4) Rejected, (5) Advice / Instruction from Client Required.
Inspection Date(s): ANY NON Yes
28/04/2021 to
CONFORMITY
29/04/2021
FOUND? No
Complete
Inspection Place(s): Kaushikkumar Patel
ORDER
JCO – III, Jindal Saw Date: 30.04.2021
STATUS
Ltd, Nanakapaya, Balance Supplier’s Signature & Date Mobile No. +91-9687000073
Mundra Telephone No.