Platform Load Cell, PWS Type 10 ... 700 KG

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Platform Load Cell, PWS Type 10 ...

700 kg

• Very low corner load error

• Good cost-benefit ratio

• Available with 0.05 % accuracy and in a


legal-for-trade version

• Use in hazardous zone with protection class


Ex ia IIC T4 Gb / Ex ia IIIC T125 °C Da
or protection class
Ex nA IIC T4 Gc / Ex tc IIIC T125 °C Dc

• ATEX and IECEx certification

• Optimized by exact calibration for


parallel circuits

• Six-wire circuitry

• 100 % Stainless steel

Application Construction Functions

PWS-type load cells convert propor- The PWS load cells are produced • High calibration accuracy which
tionally the mechanical input varia- entirely from stainless steel. provides ideal conditions for the
ble force into the electrical variable They are connected electrically by parallel arrangement of load
voltage. a high-quality, 6-wire screened PVC cells
cable.
They are ideal for use in platform The six-wire circuitry makes the • High reproducibility of the
scales, weighfeeders and bin measuring signal insensitive to differ- measuring signals
weighers. The compact design ences in lengths of the connection • Extremely low interference by
facilitates planning into any given cables. transverse loads of the meas-
construction. ured values

BV-D2214GB
Dimensions [mm]

Arrow-head on front side = Measuring force direction

Emax = Tightening Nominal


Accuracy ATEX
Nominal Part No. "A" "B" "C" measuring
load
class torque route
Category

10 kg 0,05 % V058895.B01 8,5 M8 23,8 32 N m 0,30 mm -


30 kg 0,05 % V058895.B02 8,5 M8 30,7 32 N m 0,35 mm -
60 kg 0,05 % V058895.B03 8,5 M8 30,7 32 N m 0,35 mm -
100 kg 0,05 % V058895.B04 8,5 M8 30,7 32 N m 0,45 mm -
150 kg 0,05 % V058895.B05 8,5 M8 30,7 39 N m 0,45 mm -
300 kg 0,05 % V058895.B06 8,5 M8 30,7 39 N m 0,50 mm -
500 kg 0,05 % V058895.B07 10,4 M10 36,5 79 N m 0,50 mm -
700 kg 0,05 % V058895.B08 10,4 M10 36,5 79 N m 0,50 mm -
10 kg C3 V058896.B01 8,5 M8 23,8 32 N m 0,30 mm -
30 kg C3 V058896.B02 8,5 M8 30,7 32 N m 0,35 mm -
60 kg C3 V058896.B03 8,5 M8 30,7 32 N m 0,35 mm -
100 kg C3 V058896.B04 8,5 M8 30,7 32 N m 0,45 mm -
150 kg C3 V058896.B05 8,5 M8 30,7 39 N m 0,45 mm -
300 kg C3 V058896.B06 8,5 M8 30,7 39 N m 0,50 mm -
10 kg 0,05 % V058895.B31 8,5 M8 23,8 32 N m 0,30 mm 1D/2G
30 kg 0,05 % V058895.B32 8,5 M8 30,7 32 N m 0,35 mm 1D/2G
60 kg 0,05 % V058895.B33 8,5 M8 30,7 32 N m 0,35 mm 1D/2G
100 kg 0,05 % V058895.B34 8,5 M8 30,7 32 N m 0,45 mm 1D/2G
150 kg 0,05 % V058895.B35 8,5 M8 30,7 39 N m 0,45 mm 1D/2G
300 kg 0,05 % V058895.B36 8,5 M8 30,7 39 N m 0,50 mm 1D/2G
500 kg 0,05 % V058895.B37 10,4 M10 36,5 79 N m 0,50 mm 1D/2G
700 kg 0,05 % V058895.B38 10,4 M10 36,5 79 N m 0,50 mm 3GD
10 kg 0,05 % V058895.B41 8,5 M8 23,8 32 N m 0,30 mm 3GD
30 kg 0,05 % V058895.B42 8,5 M8 30,7 32 N m 0,35 mm 3GD
60 kg 0,05 % V058895.B43 8,5 M8 30,7 32 N m 0,35 mm 3GD
100 kg 0,05 % V058895.B44 8,5 M8 30,7 32 N m 0,45 mm 3GD
150 kg 0,05 % V058895.B45 8,5 M8 30,7 39 N m 0,45 mm 3GD
300 kg 0,05 % V058895.B46 8,5 M8 30,7 39 N m 0,50 mm 3GD
500 kg 0,05 % V058895.B47 10,4 M10 36,5 79 N m 0,50 mm 3GD
700 kg 0,05 % V058895.B48 10,4 M10 36,5 79 N m 0,50 mm 3GD
Technical Data

D1 C3
Nominal characteristic value 2 ±0,002 mV/V
Combined error 0,05 % *) 0,02 % *)
Sensitivity temperature coefficient, TKc 0,045 % / 10 K *) 0,018 % / 10 K *)
Zero signal temperature coefficient, TKo 0,045 % / 10 K *) 0,014 % / 10 K *)
Zero signal tolerance ≤ 2,0 % *)
Max. number of increments - n = 3000
Min. utilization - Bamin. = 42 % (at 3000 d)
Nominal load
Min. load cell increment value ***) - V min WZ =
7143
Nominal temperature -20 °C … +40 °C
Operating temperature -40 °C … +70 °C
Explosion-proof design -30 °C … +70 °C
Storage temperature -50 °C … +85 °C
Max. excitation voltage. 15 V
Input resistance 390 ±10 Ω
Output resistance 350 ±2 Ω
Isolation resistance > 5000 MΩ
Limit load rel. to nominal load 150 %
Breaking load/ nominal load 300 %
Corner load error at 50 % nominal load 0,05 % / 100 mm
Corner load error at 50 % nominal load **) 0,5 % / 100 mm
Material Stainless steel
Protection class IP65
Explosion-proof design IP67

*) Error related to nominal characteristic value


**) at nominal load 500 kg and 700 kg
***) Example: PWS 100 kg
min. utilization Bamin = 42 kg

= 14 g (theor.Größe )
min. increment value V min WZ =
100kg
7143
i. e., the weighing electronics increment value is the next possible increment = 20 g
Electrical cable: 6 conductor and shield, 5 m long

Cable colour code:


Input voltage + green
Input voltage – black

BV-D2214GB 1614.1 All information is given without obligation. All specifications are subject to change. © by Schenck Process Europe GmbH, 2016
Measuring signal + white
Measuring signal – red
Sensor cable + orange
Sensor cable – blue

Shield yellow, pigtail isolated over its entire length

The connecting cable shield is not connected to the measuring body. Therefore, load cell grounding
has to be provided for, e.g. via the connecting structure.

Optional feature ATEX/IECEx approval

Intrinsically safe ATEX explosion-proof design category 1D/2G and IECEx EPL Da, Gb
Gas-Ex II 2G Ex ia IIC T4 Gb (Zone 1)
Dust-Ex II 1D Ex ia IIIC T125 °C Da, IP67 (Zone 20)

Warning: The verification of intrinsically safe circuit must be verified. New barriers are provided in particular
for new systems. The verifications of intrinsically safe circuit are available for all load cells and barriers.

Load cells marked as intrinsically safe - Ex "i" - are also operated intrinsically safely irrespective of the zone.

Non intrinsically safe ATEX explosion-proof design category 3GD and IECEx EPL Dc, Gc
Gas-Ex II 3G Ex nA IIC T4 Gc (Zone 2)
Dust–Ex II 3D Ex tc IIIC T125 °C Dc, IP67 (Zone 22)

Schenck Process Europe GmbH


Pallaswiesenstr. 100
64293 Darmstadt, Germany
Phone :+49 (0) 6151 1531 0
Fax: +49 (0) 6151 1531 66
sales@schenckprocess.com
www.schenckprocess.com