Platform Load Cell, PWS Type 10 ... 700 KG
Platform Load Cell, PWS Type 10 ... 700 KG
Platform Load Cell, PWS Type 10 ... 700 KG
700 kg
• Six-wire circuitry
PWS-type load cells convert propor- The PWS load cells are produced • High calibration accuracy which
tionally the mechanical input varia- entirely from stainless steel. provides ideal conditions for the
ble force into the electrical variable They are connected electrically by parallel arrangement of load
voltage. a high-quality, 6-wire screened PVC cells
cable.
They are ideal for use in platform The six-wire circuitry makes the • High reproducibility of the
scales, weighfeeders and bin measuring signal insensitive to differ- measuring signals
weighers. The compact design ences in lengths of the connection • Extremely low interference by
facilitates planning into any given cables. transverse loads of the meas-
construction. ured values
BV-D2214GB
Dimensions [mm]
D1 C3
Nominal characteristic value 2 ±0,002 mV/V
Combined error 0,05 % *) 0,02 % *)
Sensitivity temperature coefficient, TKc 0,045 % / 10 K *) 0,018 % / 10 K *)
Zero signal temperature coefficient, TKo 0,045 % / 10 K *) 0,014 % / 10 K *)
Zero signal tolerance ≤ 2,0 % *)
Max. number of increments - n = 3000
Min. utilization - Bamin. = 42 % (at 3000 d)
Nominal load
Min. load cell increment value ***) - V min WZ =
7143
Nominal temperature -20 °C … +40 °C
Operating temperature -40 °C … +70 °C
Explosion-proof design -30 °C … +70 °C
Storage temperature -50 °C … +85 °C
Max. excitation voltage. 15 V
Input resistance 390 ±10 Ω
Output resistance 350 ±2 Ω
Isolation resistance > 5000 MΩ
Limit load rel. to nominal load 150 %
Breaking load/ nominal load 300 %
Corner load error at 50 % nominal load 0,05 % / 100 mm
Corner load error at 50 % nominal load **) 0,5 % / 100 mm
Material Stainless steel
Protection class IP65
Explosion-proof design IP67
= 14 g (theor.Größe )
min. increment value V min WZ =
100kg
7143
i. e., the weighing electronics increment value is the next possible increment = 20 g
Electrical cable: 6 conductor and shield, 5 m long
BV-D2214GB 1614.1 All information is given without obligation. All specifications are subject to change. © by Schenck Process Europe GmbH, 2016
Measuring signal + white
Measuring signal – red
Sensor cable + orange
Sensor cable – blue
The connecting cable shield is not connected to the measuring body. Therefore, load cell grounding
has to be provided for, e.g. via the connecting structure.
Intrinsically safe ATEX explosion-proof design category 1D/2G and IECEx EPL Da, Gb
Gas-Ex II 2G Ex ia IIC T4 Gb (Zone 1)
Dust-Ex II 1D Ex ia IIIC T125 °C Da, IP67 (Zone 20)
Warning: The verification of intrinsically safe circuit must be verified. New barriers are provided in particular
for new systems. The verifications of intrinsically safe circuit are available for all load cells and barriers.
Load cells marked as intrinsically safe - Ex "i" - are also operated intrinsically safely irrespective of the zone.
Non intrinsically safe ATEX explosion-proof design category 3GD and IECEx EPL Dc, Gc
Gas-Ex II 3G Ex nA IIC T4 Gc (Zone 2)
Dust–Ex II 3D Ex tc IIIC T125 °C Dc, IP67 (Zone 22)