Installation Instructions: Technical Specifications
Installation Instructions: Technical Specifications
Installation Instructions: Technical Specifications
TECHNICAL SPECIFICATIONS
Power Source 220-240V AC Class II
Detection Range 10 metres max, 150°
Time Setting Min: 10sec ± 5sec
Max: 4min ± 1min
Dusk Control Day to Night (adjustable)
PIR Aiming adjustment Pan/Tilt
Sensitivity Control Yes
Manual Override Yes
Standby Power <1W (sensor head only)
Rated Load 20 Watts
Lumens 3000K, 1800 lumens
4000K, 2000 lumens
5000K, 2000 lumens
Protection Rating IP54
Mounting Ceiling or wall
Construction Polycarbonate UV stabilised
! IMPORTANT
This product is suitable for use only with a supply voltage of 220-240V AC 50Hz.
All electrical work must be carried out in accordance with local and national electrical codes as applicable.
We strongly recommend that this light fitting is installed by a registered electrician.
Always switch power off prior to installation. A means of mains power isolation must be installed in the circuit
for the purpose of safe access for any internal cleaning, recalibration, or maintenance.
This light fitting is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety. Young children should be
supervised to ensure that they do not play with the appliance.
Any changes or modifications made or attempted to this product, without the prior written approval of the
manufacturer, will void any and all stated warranties.
BEFORE YOU START
The Eco Spot Select should be wired to its own light switch. Do not interconnect with other lights on
the same switch. An earth connection must be used for electrical safety.
To achieve best results, please consider the following points:
Eco Spot Select should be mounted 1.8 to 2.5 metres above the ground.
To avoid false triggering, the sensor should be directed away from heat sources such as barbecues, air
con, flue vents etc.
Do not aim towards reflective surfaces such as smooth white walls, swimming pools, etc.
Before selecting a place to install your Eco Spot Select, note that movement across the scan area
is more effective than movement directly toward or away from the sensor.
INSTALLATION
Fig. 1
Fig. 2
Day
Night
Selecting lamp colour with power supply connected 10 Sec 4 Min 3 mtr 10 mtr
may cause irrepairable damage. Always disconnect
at mains before making any colour seletion.
CALIBRATION
The length of time the Eco Spot Select remains switched on after activation can be adjusted from
(10±5) seconds to (4±1) minutes. Rotating the TIME knob to (+) or (-) will adjust the duration time
accordingly.
Note: Once the light has been triggered by the PIR sensor any subsequent detection will restart the
timed period.
The sensitivity means the maximum distance which PIR Sensor can be triggered by motion. Adjusting the
SENS knob from (+) to (-) will adjust the sensitivity.
The LUX control module has a built-in sensing device (photocell) that detects daylight and darkness.
The ( ) position indicates it will work at day and night, and in the ( ) position - only at night. Set dial to
operate at the desired level by adjusting the LUX knob.
PRODUCT COMPLIANCES
Product complies with:
AS/NZS 60598.1:2017 AS/NZS 60598.2.1:2014 AS/NZS CISPR15:2017
EN61000.3.2:2014 EN61000.3.3:2013 EN55015.2013 EN62031.2015 EN62473.2015
AS/NZS 61347.1:2016 AS/NZS 61058.1:2008 and relevant amendments