01-08 Overview of Boards
01-08 Overview of Boards
01-08 Overview of Boards
8 Overview of Boards
For the OSN 1800, the electrical-layer service boards are named in accordance
with the following naming structure:
CAUTION
Always wear an ESD wrist strap when holding a board, and ensure that the ESD
wrist strap is well grounded, to prevent static discharge from damaging the board.
Universal single-slot board (such as 19.8 x 193.8 x 205.9 (0.8 x 7.6 x 8.1)
ELOM, LDX, SBM2, FIU, and OBU)
Universal dual-slot board (such as 40.1 x 193.8 x 205.9 (1.6 x 7.6 x 8.1)
C12X5, LTX, and EX40)
1800 I&II Compact System control 19.8 x 193.8 x 205.9 (0.8 x 7.6 x 8.1)
board (TNF3SCC)
1800 V System control, cross-connect, 24.9 x 388.4 x 205.9 (1.0 x 15.3 x 8.1)
and clock board (XCH, UXCM, UXCME,
and UXCMS)
1800 I Enhanced System control, cross- 19.82 x 388.4 x 220 (0.8 x 15.2 x 8.6)
connect, and clock board (TMA1UXCL)
1800 II Enhanced System control, 22.4 x 193.8 x 205.9 (0.9 x 7.6 x 8.1)
cross-connect, and clock board
(TNZ1UXCL and TNZ2UXCL)
1800 II TP System control board 19.8 x 193.8 x 205.9 (0.8 x 7.6 x 8.1)
(TMB1SCC)
Turbo WDM Boards(NP200, NP200E) 40.1 x 193.8 x 208.7 (1.6 x 7.6 x 8.2)
1800 I fan unit (TNF1FAN02) 41.4 x 27.5 x 205.8 (1.6 x 1.1 x 8.1)
1800 II compact fan unit (TNF1FAN01) 85.7 x 27 x 205.8 (3.4 x 1.1 x 8.1)
1800 I&II Compact DC power board 41.4 x 20 x 205.8 (1.6 x 0.8 x 8.1)
(TNC1PIU and TND1PIU)
1800 I&II Compact AC power board 40.1 x 193.8 x 205.9 (1.6 x 7.6 x 8.1)
(TNF1APIU)
1800 V Fan unit (TNF5FAN) 218 x 50.5 x 208.2 (8.6 x 2.0 x 8.2)
1800 V DC power board (TNF5PIU02) 19.8 x 95.5 x 208.9 (0.8 x 3.8 x 8.2)
1800 V AC power board (TNF5APIU) 40.1 x 193.8 x 208.9 (1.6 x 7.6 x 8.2)
1800 I Enhanced Fan unit (TMA1FAN) 27.5 x 42 x 235.4 (1.1 x 1.7 x 9.3)
1800 I Enhanced AC power board 19.8 x 193.8 x 196.3 (0.8 x 7.6 x 7.7)
(TNF2APIU)
1800 II Enhanced Fan unit (TNZ1FAN) 85.7 x 27 x 205.8 (3.4 x 1.1 x 8.1)
1800 II TP Fan unit (TMB1FAN) 85.5 x 34.9 x 207.5 (3.4 x 1.4 x 8.2)
1800 II TP/1800 II Pro/1800 V Pro AC 40.1 x 193.8 x 208.9 (1.6 x 7.6 x 8.3)
power board (TMB1APIU)
NOTE
The depth of a board refers to the length from the backplane connector to the front panel,
excluding dimensions of protruding components such as ejector levers, terminals, and optical
modules.
DANGER
It is strictly forbidden to stare into optical ports during fiber installation and
maintenance, because the laser beam inside the fibers would hurt your eyes.
NOTE
The barcode shown in the figure is used as an example only and it may differ in practice.
2 BOM Code Indicates the last four digits of an 8-bit BOM number.