Release Notes: Analyzer Update December 2019
Release Notes: Analyzer Update December 2019
Release Notes: Analyzer Update December 2019
The content of this manual is provided for information only, is subject to change without notice, and should
not be construed as a commitment by Amdocs. Amdocs assumes no responsibility or liability for any errors
or inaccuracies that appear in this documentation.
The content of this manual is provided for information only, is subject to change without notice, and should
not be construed as a commitment by Actix. Actix assumes no responsibility or liability for any errors or
inaccuracies that appear in this documentation.
The product is protected under national and international copyright, trademark and trade secret, patent
and other intellectual property laws and treaties. The product is covered by at least one or more of the
following U.S. patents: 8364141; 7653395; 8032131; 7941136; 8150417; 7881319; 7830812; 7904080; 7839846;
7062264; 7349692; 7224968; 7792032; 7634267; 7353160; 8428171; 7877095; 7768968; 8855675; 9154977;
9380170; Sweden Patent: 524414; Great Britain Patents: 2,461,242; 2,467,474; 2,196,050; 1,759,549; 1,716,668;
1,678,972; 2,382,502; 2,384,663; 2,404,314; 1,606,965; Australia Patent: 2003301796; Patents registered in
China P.R.: 1,934,882; ZL200480007621.7; CN1817056; Patents registered with the European Patent Office:
EP1604278; EP1559289; EP1614313; EP2196049; French Patents: 2,196,050; 1,759,549; 1,716,668; 1,678,972;
1,468,542; 1,606,965; German Patents: 2,196,050; 1,759,549; 1,716,668; 1,678,972; 1,468,542; 102004002145;
103 07 408; 102 51 993.5; 101 04 926; Holland Patent: 2,196,050; India Patent: 1130/CHENP/2005; Italian
Patent: 2,196,050; Patents registered in Japan: 4,499,746; 4,452,710; JP549116/2004; JP5139462; JP6125530;
Patents registered in Korea: 10-11-21435; 10-09-39132; New Zealand Patent: NZ540378; Patents registered in
Spain: 2,196,050;1,606,965; and pending patents.
Copyright © 2007-2019 Actix, an Amdocs company. All rights reserved. All trademarks are hereby
acknowledged.
Contents
In This Version ...................................................................................................................................... 4
Technology Improvements.............................................................................................................. 5
5G-NR support ............................................................................................................................................... 5
o Support added for LTE MIMO antenna radio paths with PCTel scanners
o Further Qualcomm X55 message decode support, with a further three LTE
log codes, and nine NR log codes supported
o Stability improvements for R&S ROMES4 and QualiPoc v19.2
o Further 5GNR NSA event detection changes
5G-NR support
• Support has been added for Samsung Galaxy S10 5G (SM-G977U) and ZTE Axon
10 Pro 5G (A2020N3) devices with TEMS Investigation.
• Decode improvements have been made for Nemo Outdoor 5G UE (attributes have
been extracted from 14 new messages).
• Qualcomm X55 message decode support has been improved, with a further 3 LTE
log codes and 9 NR log codes supported.
• Support has been added for the nrcelllookup() function in query expressions.
• Added support for NR5G RLC DL Control PDU and NR 5G MAC CSF Report into the
Qc_Log_Code format group enumeration.
• Resolved a problem where file loading appeared to freeze for RSCMD files
captured from ROMES4 v19.2.
• Improvements have been made to the 5GNR UE detection for QualiPoc v19.2 SQC
files.
• Improvements have been made to the stability of loading v19.2 files collecting
5GNR measurements.
Event Detection
• Improvements have been made to the reporting of LTE_5GNSARelease_Cause
in cases where:
o Quick ping-pong between EN-DC and LTE occurs;
LTE_5GNSARelease_Cause and
LTE_5GNSARelease_5GNRBearerRelease are now being set.
o The file ends shortly after the reconfiguration;
LTE_5GNSARelease_Cause and
LTE_5GNSARelease_5GNRBearerRelease are now being set.
General
• Improvements have been made to the reporting of Physical_Throughput_UL, to
calculate it every 500ms, which keeps it aligned with Physical_Throughput_DL
in both LTE and LTE-NSA modes, and corrected the calculation to convert to Kbps.
o data volume (bytes) * 8 (bits) / 0.5 (seconds) * 1000
Format Groups
• Added support for the NR5G RLC DL Control PDU and NR 5G MAC CSF Report into
the Qc_Log_Code format group enumeration.
Spotlight
• Resolved a problem that cause a misalignment in the legend and values in the
Spotlight Radio Network Explorer task panel, at certain screen resolutions:
Task Pages
• Resolved a problem where previous task pages including custom repository
templates were no longer compatible with the latest versions of Analyzer,
regarding the addition of the Description field to the XML schema.
Data Processing
• Extended the query function language to include cell lookup functions for 5G NR
cells. Example syntax is as follows:
o nrcelllookup( "Sector_ID",
state(Latitude),
state(Longitude),
state(NR_UE_NR_ARFCN_DL[0]),
state(NR_UE_PCI[0])
)
o nrsitelookup( "SiteID",
state(Latitude),
state(Longitude),
state(NR_UE_NR_ARFCN_DL[0]),
state(NR_UE_PCI[0])
)
Diagnostics
• PC date and time have been added to the Diagnostics report to assist Product
Support activities.
Following the end of June 2020, support for Actix Analyzer running on Windows 7
shall be deprecated and support cases shall no longer be accepted if they relate to
issues arising from these OS versions.