JENKA System
1. General Information
The Peikko JENKA anchor is a component of the
Peikko transport anchor system and is in compliance
with the safety regulations set forth by the (German)
Construction Trade Association “Sicherheitsregeln für
Transportanker und -systeme von Betonfertigteilen”
(BGR 106).
Compliance with this installation and operation manual
is necessary for the use of Peikko JENKA anchors. The
anchors are only designed to operate with original Peikko
Lifting Devices. All existing installation and usage manu-
als must also be considered.
The Peikko JENKA System is designed for the transport
of precast concrete construction components. Compo-
nents should not see repeated operation. Construction
components (specifically the transport anchor) may
undergo some erosion during the transport of a com-
ponent from the place of production to the place of
installation, however this is not considered as repeated
operation. Repeated operation is for example, the use of
precast concrete components as a removable dam, or
as counterweight of a crane; this is only permissible if
warranted by the type approvals “Erzeugnisse, Verbind-
ungsmittel und Bauteile aus nichtrostenden Stählen”
(“Products, Connections, and Construction Components
of Stainless Steel”) (DiBT Berlin, Zulassung Nr Z30.3-6). Figure 1:
Dimensions Load
Fs * Fq *
Article Nr. Type ØD h e Øds Capacity
4
Table 2: Dimensions Peikko JENKA WAS-Anchor
Dimensions Load
Fs *
Article Nr. Type ØD h e Øds Capacity
Dimensions Load
Fs * Fq *
Article Nr. Type ØD h e Øds Capacity
www.peikko.com
JENKA System
Table 4: Dimensions Peikko JENKA TF-Anchor
Dimensions Load
Fs * Fq *
Article Nr. Type ØD h e Øds ØD1 Capacity
Dimensions Load
Fs *
Article Nr. Type ØD h e Capacity
Dimensions Load
Fs * Fq *
Article Nr. Type ØD h e Øf Capacity
Dimensions Load
Fs * Fq *
Article Nr. Type ØD h e Øf Capacity
www.peikko.com
JENKA System
Table 8: Dimensions Peikko JENKA PSA-Anchor
Dimensions Load
Fs *
Article Nr. Type ØD h a b t Capacity
da de d dred*
Size
[mm] [mm] [mm] [mm]
RD12 300 150 60 60
RD14 400 200 60 60
JENKA Anchor
RD16 400 200 80 65
RD18 500 250 100 80
RD20 550 275 100 90
RD24 600 300 120 100
Identification Ring RD30 650 325 140 120
RD36 800 400 200 150
RD42 1000 500 240 160
Figure 3: Assembly
RD52 1200 600 275 180
* only for SRA in angular pull angle ß of 12.5º to a max of 30º
d or
dr
ed
Figure 4: Distances
9
www.peikko.com
JENKA System
Table 11: Distances (de), Axial Distances (da), Component Table 12: Distances (de), Axial Distances (da), Component
width (d) valid for WAS in slabs. width (d) valid for WAS in slabs.
da de d da de d
Size Size
[mm] [mm] [mm] [mm] [mm] [mm]
RD12 360 180 80 RD12 350 180 70
RD14 420 210 90 RD14 350 180 80
RD16 180 240 100 RD16 500 250 85
RD18 540 270 110 RD18 600 300 95
RD20 600 300 120 RD20 600 300 100
RD24 690 345 135 RD24 800 400 115
RD30 900 450 170 RD30 1000 500 140
RD36 1300 650 160
RD42 1300 650 175
RD52 1500 750 215
2.4 Reinforcement
Table 13: Minimum reinforcement for walls and beams valid for SRA, WAL, WAS, TF, CSA, and ESA
BS 8666:2005
number
mesh Basic reinforcement For Component width For Component width
reinforce- d d or. dred
Size
ment 12,5° ≤ β ≤ 45° 12,5° ≤ β ≤ 30°
Øds L a b Size
2
[mm /m] Øds L dBr Øds L dBr
[Pc.] [mm] [mm] [mm] [mm]
[mm] [mm] [mm] [mm] [mm] [mm]
RD12 131 A142 2 6 250 60 60
RD12 6 150 24 6 150 24
RD14 131 A142 2 6 360 60 70
RD14 6 200 24 6 200 24
RD16 131 A142 2 8 420 90 70
RD16 8 200 32 6 250 24
RD18 188 A193 2 8 530 90 80
RD18 8 250 32 8 200 32
RD20 188 A193 2 8 640 90 80
RD20 8 300 32 8 250 32
RD24 188 A193 2 10 640 90 100
RD24 10 300 40 8 300 32
RD30 221 A252 2 12 830 90 110
RD30 12 400 48 10 350 40
RD36 221 A252 2 14 1140 140 120
RD36 14 550 56 12 450 48
RD42 513 2 16 1250 140 120
RD42 16 600 64 14 600 56
RD52 513 2 20 1530 140 150
RD52 20 750 140 16 700 64
d or
d red
www.peikko.com
JENKA System
2.4.3 Reinforcement for Lateral Pull
A load in lateral pull with γ ≥ 15º requires an additional
reinforcement to be incorporated following table 16 in
the face counteracting the direction of pull (figure 11).
Loads in lateral pull (with the use of chain overhead
conveyors) requires no further measures, as the stirrup
provides for this load as well. During lowering and rais-
ing of the component, the direction of the reinforcement
should always be checked (figure 11). Lateral lifting is
allowed only for components with minimum thickness
“d” according to table 9.
Attention: for Peikko JENKA anchor types BSA, PSA,
and WAS, lateral pull is not permissible.
2.5 Corrosion
Lifetime of installed Peikko JENKA Anchors is limited
due to corrosion. Even through the use of electric zinc
plated anchors, corrosion damage can occur and cause
rust damage to the component surface. Corrosion dam-
age can be avoided if after final placement the anchor is
covered with mortar and sufficient concrete covering. If
Lateral-Angular Pull
the JENKA anchor is to be consistently used in outdoor
environments, Industrial environments, or in the vicinity
of sea, we recommend the use of Peikko JENKA an-
chors made of stainless steel. Electric zinc plated Peikko
JENKA anchors should only be stored for a longer time
in dry environmental. To protect the anchors against rust
we recommend to use JENKA CPP plastic plugs.
Figure 9: Angle of Lateral Pull γ
12
3. Lifting Device followed. While following the instructions of this guide,
user shall also follow the regulations UVV BGV D6 Krane
JENKA TLL and BGR 500, “Betreiben von Lastaufnahmeeinrichtun-
gen im Hebezeugbetrieb”. The Peikko JENKA TLL wire
rope lifting loop is only designed to operate with Peikko
3.1 Materials and Dimensions JENKA anchors, other use is not permitted (BGR 106
section 5.2). Prior to use the intended allocation and use
The Peikko JENKA TLL wire rope lifting loop (table 17) is of the system component must be reviewed. Through
a component of the Peikko transport anchor system and a clear label, the manufacturer, the type, and the load
is in compliance with the safety regulations set forth by capacity can be easily identified.
the (German) Construction Trade Association “Sicherheit-
Peikko JENKA TLL wire rope lifting loops are made
sregeln für Transportanker und -systeme von Betonfer-
from electric zinc plated wire strands and a crimped
tigteilen” (BGR 106).
steel shell. Upon the crimped shell an outside thread
For the use of Peikko JENKA TLL wire rope lifting loop, is established (metric thread according to DIN 13 or
this brochure, the installation and usage manual for special roundthread). The installation of the JENKA TLL
JENKA transport anchors, and the General Instruction is designed for the transport of precast concrete com-
and Usage Manual for Transport Anchors must all be ponents. The Peikko JENKA TLL wire rope lifting loop is
suitable for load classes 0,5t to 12,5t.
Dimensions Load
Fs *
Article Nr. Type h e Capacity
3.2 Usage
Labeling
All Peikko JENKA TLL wire rope lifting loops are fitted TLL20 2000kg
with a load capacity tag (figure 12). The tag includes the
manufacturer, the load capacity, and the type, much like
the CE labelling. Additionally the load capacity tags are
colour coded, this makes identification of which JENKA
anchor and JENKA TLL wire rope lifting loop to use in
combination both quick and easy.
www.peikko.com
JENKA System
Usage
Prior to use of the Peikko JENKA TLL wire rope lifting
loop the intended use of the system component must
be reviewed for safety, the Peikko identification tags
makes this easier. The Peikko JENKA TLL wire rope
lifting loop can only be used with JENKA anchors. The Allowed
JENKA TLL can be used multiple times. Improperly
used, corroded, or otherwise damaged Peikko JENKA
components should not be installed or see further use. Not Allowed
Alterations or welding of JENKA components is not
allowed.
The Peikko JENKA TLL is to be fully screwed into the
JENKA anchor so that the threaded end is inside the
socket of the anchor. The JENKA anchors are designed
so that the JENKA TLL threads can always be complete-
ly screwed into the anchor. Incompletely screwed lifting
loops can not bear load.
The following points must be reviewed during installa-
tion: Figure 14: Case of Operation Straight Pull
14
3.4 Checking the Peikko 4. Lifting Device
JENKA TLL JENKA JL
The amount of inspection and the required concrete
maturity for loading and load capacity components 4.1 Materials and Dimensions
conforms to the regulations in BGR section 3.15.4. The
following is a list of inspection criteria to be reviewed. The Peikko JENKA Lifter (table 17) is a component of the
• Damage to the threads Peikko JENKA transport anchor system and is in compli-
ance with the safety regulations set forth by the (Ger-
• Kinks man) Construction Trade Association “Sicherheitsregeln
• Breaking of strands für Transportanker und -systeme von Betonfertigteilen”
(BGR 106).
• Loosening of the exterior length in free length
For the use of the Peikko JENKA Lifter, this brochure,
• Corrosion marks the installation and usage manual for JENKA transport
• Damage or heavy wear upon the loop or the con- anchors, and the General Installation and Usage Manual
nection head. of the Peikko transport anchors must all be followed.
Adherence to this guide does not absolve the user from
• Any wire breaks. following the regulations UVV BGV D6 Krane and BGR
500, “Betreiben von Lastaufnahmeeinrichtungen im He-
The complete extent of the inspection can be found in
bezeugbetrieb”. The Peikko JENKA Lifter is only designed
BGR 500 chapter 2.8, 3.15.1.
to operate with Peikko JENKA anchors and Peikko nail-
plates NPP, other use is not permitted (BGR 106 section
5.2). Prior to use the intended allocation and use of the
3.5 Corrosion Protection system component must be reviewed. Through a clear
label, the manufacturer, the type, and the load capacity
The durability of reinforced concrete components with can be easily identified.
installed Peikko JENKA TLL load suspension compo-
nents is assured, damage through corrosion is limited. Peikko JENKA Lifters are made from tempered steel
Lifting loops can leave corrosion scars upon the surface with a welded forged threaded screw adapter. Installa-
of a concrete component. tion is designed for precast construction components.
Peikko JENKA Lifter can be ordered with metric threads
according to DIN 13 or with a special roundthread. The
JENKA Lifter is available for load classes 0.5t to 12.5t.
Dimensions Load
Article Fs * Fq *
Type B H e Ød Capacity
Nr.
R or M [mm] [mm] [mm] [mm] [kg] [kN] [kN]
JL12 12 50 150 19 13 500 5 2,5
JL14 14 50 150 21 13 800 8 4,0
JL16 16 50 150 24 13 1200 12 6,0
JL18 18 50 162 27 16 1600 16 8,0
JL20 20 50 162 29 16 2000 20 10,0
JL24 24 50 162 35 16 2500 25 12,5
JL30 30 50 177 43 22 4000 40 20,0
JL36 36 50 177 52 22 6300 63 31,5
JL42 42 65 218 60 26 8000 80 40,0
JL52 52 65 218 73 26 12500 125 62,5
www.peikko.com
JENKA System
4.2 Usage
Labelling
All Peikko JENKA Lifters are imprinted with a perma-
nent marking on its ring (figure 16). This includes the
manufacturer, the load capacity, and the type, much like
the CE labelling. Finding compatible Peikko anchors and
Lifters is possible through these markings.
Usage
The installation of the Peikko JENKA Lifter must take
into consideration the General Information for Installa-
tion of Peikko transport anchors, this brochure, and the
usage manual for Peikko JENKA anchors. Prior to use
the intended allocation and use of the system compo-
nent must be reviewed. The load suspension devices
of the Peikko JENKA System (JENKA TLL and JENKA
Lifter) are only designed to operate with the Peikko
JENKA anchor. The JENKA load suspension devices can
undergo multiple loads from the place of casting to the Figure 16: JENKA Lifter Identification
place of installation. Improperly used, corroded, or oth-
erwise damaged Peikko JENKA components should not
be installed or see further use. Alterations or welding of
JENKA components is not allowed.
The following points must be reviewed during installa-
tion.
• Unclean threads must be cleaned
• Visual inspection of the JENKA JL must be estab-
lished.
• Concrete maturity must be verified according to ac-
cident prevention regulations (BGR 500, BGI 556).
• Thread is completely screwed into the anchor.
• Appropriate lifting components (hook size and hook
form) is used.
• Peikko JENKA components should not come in
contact with acids or lye.
• The Peikko JENKA Lifter should only undergo loads Figure 17: JENKA Lifter Installation for Axial and Angular Pull
from the directions shown in figures 17 - 18, loads
as shown in figures 19 - 21 are impermissible.
The Peikko JENKA Lifter is used with the JENKA nail- Allowed
plate NPP. After fully screwed into place, the load sus-
pension device is ready to apply force to the concrete ed
A llow
(figure 22). For the alignment in the direction of pull, the t
No
Lifter can be unscrewed a maximum of half a rotation.
Improper direction of pull (Pulling over corners, or in
angular pull greater than 45º) can lead to damage of
the ring or the threaded head. The concrete maturity is
greatly effected.
ed
A llow
N ot
Figure 19: JENKA Lifter Installation for Lateral Pull Figure 22: JENKA Lifter Installation
www.peikko.com
JENKA System
Damaged or worn out load suspension devices can no
longer be installed or used. Table 19 has inspection and
wear values for the ring head of the Peikko JENKA Lifter.
Tmax = Ødmin =
T Ød
Type 1,05 x T 0,9 x Ød
[mm] [mm] [mm] [mm]
RD/M12 115 121 13 11,7
RD/M14 115 121 13 11,7
RD/M16 115 121 13 11,7
RD/M18 115 121 16 14,4 Figure 24: Average Link Thickness
19