r300x Quick Basic English PDF
r300x Quick Basic English PDF
r300x Quick Basic English PDF
Electronic
Quick Reference Guide
Total Station
www.pentaxR300X.com
Total Surveying Solutions
1 Basic Operation 9
1.1 Removing the Battery 9
1.2 Attaching the Battery 9
1.3 Turning the Power On and Off 9
1.4 Centering and Leveling 9
1.5 Target Sighting (Focusing) 10
1.5.1 Auto-Focus 10
1.5.2 Power Focus 10
1.5.3 Manual Focus 10
1.5.4 Continuous AF mode 10
1.6 Angle Measurement 11
1.6.1 Horizontal Angle 11
1.6.2 Vertical Angle 11
1.7. Distance Measurement 12
1.7.1 Select your target 12
1.7.2 Distance Measurement 12
1.7.3 Changing Target constants 12
1.7.4 Input Temperature and Atmospheric pressure 13
1.7.5 Laser pointer 13
1.7.6Adjusting Laser Plummet brightness 13
1.7.7 Adjusting LCD contrast 13
1.7.8 Adjusting Illumination brightness 14
4 Specifications 19
Notice to the user of this product 20
5
Instruction Manuals
Quick Reference Guide is intended to provide a quick reference in the
field. For ease of use in the field, the following Quick Reference Guide
booklets are provided in the carrying case.
1. Basic procedure
2. PowerTopoLite for R-300X series, Operating procedure
WARNING
Solar Observation
Never view the sun directly using the telescope as this may result
in loss of sight.
Laser Safety
R-300NX is a class-IIIa (3R) Laser product. Avoid direct eye exposure.
R-300X without “NX” is a class-II (2) Laser product. Do not stare into
laser beam.
6
Risk of Explosion
Do not use this product in a location where there is coal dust, or
near flammable material as there is a risk of explosion.
USAGE PRECAUTIONS
Target Constant
Confirm the Target Constant of the instrument before measurement.
Auto focus
The Auto focus may not function under every condition depending
on brightness,contrast,and the shape and size of the target.In such
a case, use the Power Focus buttons or the manual focus ring.
Atmospheric correction
During surveys for which the survey precision or atmospheric
measurement method is defined, measure the atmospheric
temperature and pressure separately and enter those values rather
than using the Automatic Atmospheric Correction function.
7
1. Basic Operation
1.1 Removing the Battery
(1) Place the channel on the bottom of the battery pack, onto the
protrusion of the instrument and push the battery pack down
into place.
(2) Turn the knob clockwise.
To shut down :
NOTE: The power is automatically turned off after 10 minutes
of inactivity (Factory default setting).
PLUM.ADJ ENT
To activate laser plummet : (for the first time
F3
after power on)
or:
ESC
To deactivate : or:
NOTE: The laser plummet and the electronic vial are always
activated at the same time.When the power is switched on,
however, only electronic vial is activated (Factory default setting).
To change the power-on activation of laser plummet, refer to
“2.3 Instrument setting items”.F
9
1.5 Target Sighting (Focusing)
1.5.1 Auto-Focus
Aim using the telescope collimator, and press
NOTE: Track the target by keeping the target close to the center
of the reticle as much as possible.
NOTE: In case the focus does not change for one minute, the
continuous AF mode will also terminate automatically.
10
1.6 Angle Measurement
[ ]
or MODE A screen
HOLD
To release HOLD : F3
11
1.7.1 Select your target
Select target type (measurement mode):
TARGET TARGET
(Reflecting sheet) F2
(Prism) F2
(Reflectorless)
TARGET
F2
NOTE: The selected target is maintained until next time you change.
1.7.2 Distance measurement
For a single shot measurement:
MEAS
F1
[ When “Long Range
Mode” is displayed
ENT
]
NOTE: “Long Range Mode”is displayed only when measuring with
higher laser power (in reflectorless measurement with the
instrument setting “REF.LESS RANGE”set as “LONG”and
“Warning Message”set as “ON”.)
MEAS MEAS
For tracking measurement : F1 F1
ENT
input value , , 0 9 , . x2
by using : F1 F2
12
MODE CORR SELECT
To change Sheet constant: F5 F4 F4 F5
ENT
input value by using: , , 0 9 , . x2
F1 F2
ENT
input value by using: , , 0 9 , . x2
F1 F2
ENT
input value by using: , , 0 9 , . x2
F1 F2
LD POINT
To quit Laser pointer : F2
13
1.7.8 Adjusting Illumination brightness
ILLU RECTICLE ENT
+ F5
for LCD F3
(for Reticle) F1
or F2
SELECT ENT
F5
Change the setting x2
SELECT ENT
F5
Change the setting x2
14
007 code HELP menu list Default Other options
401 TARGET CONST PRISM CONST -30mm 0mm, INPUT
SHEET CONST 0mm INPUT
402 ATM CORR AUTO ATM INPUT, ppm INPUT, NIL
501 MEAS. MIN DISP COARSE FINE
502 SHOT COUNT SHOT CONT 1 time 3 times, 5 times, INPUT
SHOT INPUT 01 times (input)
503 CRV/REF CORR 0.14 0.2, NIL
504 MIN UNIT ANG. FINE COARSE
505 V. ANG. STYLE Z.0 H.0, COMPASS
508 DIST.BUZ ON OFF
509 QUAD BUZ OFF ON
510 AUTO OFF 10 MIN 20 MIN, 30 MIN, NIL
511 EDM OFF 3 MIN 5 MIN, 10 MIN, NIL
512 ILLU.OFF 3 MIN 5 MIN, 10 MIN, NIL
514 MEAS.SIGNAL MARK VALUE
515 PRIORITY SELECT PRIM.MEAS KEY MEAS SHOT MEAS CONT, TRACK SHOT, TRACK CONT
SEC.MEAS KEY TRACK CONT TRACK SHOT, MEAS CONT, MEAS SHOT
15
AUTO MEAS. NIL MEAS., TRACK
PRIORITY DISP HA/HD/VD HA/VA/SD, HA/VA/HD/SD/VD
517 COMP AXIS 3 Axis (2/3”model) or 2 Axis 2 Axis (2/3” model), 1Axis, , NIL
520 LD PLUM.&E.VIAL LD PLUM. OFF (when Power On) ON (automatically ON)
TILT DISP. OFF ON
TILT DISP.UNIT COARSE FINE
521 REF.LESS RANGE RANGE NORMAL LONG
MESSAGE ON (when Range is LONG) OFF
SETUP EACH TIME (w/ Power ON) PERMANENT
522 QUICK MEAS OFF ON
701 ATM UNIT TEMP.UNIT Centigrade Fahrenheit
PRESS UNIT hPa mmHg, inchHg
702 DIST.UNIT m ft, ft+inch
703 ANG.UNIT DEG DEC, GRD, MIL
801 SET UP COM. BAUD RATE 1200 2400, 4800, 9600
DATA LENGTH 8 7
PARITY BITS NIL EVEN, ODD
STOP BITS 1 2
SIGNAL CONTROL ON OFF
XON/XOFF ON OFF
THROUGH COMMAND NIL a, b, c, d, e,f
3. Basic Field Checking Procedures
Checks and Adjustments should be performed before and during
measurement.
Check if the bubble stays at the center of each vial, when rotating
the instrument by 180°.
NOTE: Press these two keys for 1 second longer, then release
key first.
(for the first time after Power on) or (from measurement screen)
Check if the laser spot on the ground stays at the same position when
rotating the instrument around the vertical axis.
To adjust the laser plummet: Contact your local dealer
LD POINT
or (from measurement screen) F2
Check if the projected laser spot points at the same position that is
aimed by the center of the cross-hair line of the telescope.
To adjust the laser pointer: Consult your local dealer.
16
3.4 Warning and Error Messages
Excess data The input data exceeds the allowable Press the [ESC] key and
range. enter the correct data.
Li-batt.voltage is • The Date Clock is powered by the Have the lithium battery
low. built-in lithium battery. replaced by the dealer
• The lithium battery needs to be from whom the
replaced in five years. instrument was purchased.
17
Error Message Meaning What to do
ERROR!! EDM ERROR Distance measurement system problem Turn the power
04 -05, 34-39, 50-53 off, and then turn on
again. Repair is
ERROR!! Angle measurement system problem needed when the
ETH ERROR 70-76 message appears
consistently.
ERROR!! Memory problem
MEMORY ERROR 19
The speed at which light travels through the air varies depending
on the temperature and atmospheric pressure. The R-300X series is
designed to measure distances at the speed of light in order to
measure accurately, atmospheric correction needs to be used.
The instrument is designed to correct for weather conditions
automatically if the temperature and pressure are input.
Correction is then carried out based on the following formula.
Calculation formula:
18
4. Specifications Reflectorless items are applicable to “NX” models only.
B) Radiant power
The R-300X is designed and built to radiate a maximum average
radiant power of 4.75mW (0.95mW for the model without “NX”)
from the telescope,and 0.95mW from the center hole of the base
plate.The user may be subject to this radiation as a beam while
operation until such time that the instrument is turned off.
21
C) Warning logotype is located on the surface of the telescope:
“CAUTION LASER RADIATION DO NOT STARE INTO BEAM”
22
AVOID EXPOSURE
Laser radiation
is emitted from
this aperture
R325EX R325NX
R335EX R335NX
R315EX R315NX
23
R322EX R322NX
R323EX R323NX
R326EX
Identification label
AVOID EXPOSURE
Laser radiation
is emitted from
this aperture
Aperture label
24
from this aperture
2-5-2 Higashi Ozumi Nerima-ku. Tokyo 178-8555 Japan LED is turned on at the time of emission
This Laser product is complied with the provisions of 21
CFR 1040-10 and 1040-11 For a class II product
ASSEMBLED BY PENTAX VN Co. LTD
Sai Dong B Industrial zone. Gia Lam. Hanoi Vietnam
CAUTION
LASER RADIATION - DO NOT
STARE INTO BEAM
620-690nm/0.95mW max.
CLASS II LASER PRODUCT
Laserclass II, conform FDA 21 CFR
Ch. 1 § 1040
DANGER
LASER RADIATION - DO NOT STARE
INTO BEAM OR VIEW DIRECTLY
WITH OPTICAL INSTRUMENT
INTO SUNLIGHT
620-690 nm/4.95mW max.
CLASS IIIa LASER PRODUCT
Laserclass IIIa, conform FDA 21 CFR
Ch. 1 § 1040
26
PENTAX Industrial Instruments Co., Ltd.
2-5-2 Higashi-Oizumi
Nerima-ku, Tokyo 178-0063, Japan
Tel. +81 3 5905 1222
Fax +81 3 5905 1225
E-mail: international@piic.pentax.co.jp