With alternator energize input
Similarly to diode battery isolators, FET isolators allow simultaneous charging of two or more
batteries from one alternator (or a single output battery charger), without connecting the batteries
together. Discharging the accessory battery for example will not result in also discharging the
starter battery.
In contrast with diode battery isolators, FET isolators have virtually no voltage loss. Voltage drop is
less than 0,02 Volt at low current and averages 0,1 Volt at higher currents.
Argo FET 100-3
3bat 100A When using ARGO FET Battery Isolators, there is no need to also increase the output voltage of the
alternator. Care should taken however to keep cable lengths short and of sufficient cross section.
Example:
When a current of 100 A flows through a cable of 50 mm2 cross section (AWG 0) and 10 m length
(30 ft), the voltage drop over the cable will be 0,26 Volt. Similarly a current of 50 A through a cable
of 10 mm2 cross section (AWG 7) and 5 m length (15 ft) will result in a voltage drop of 0,35 Volt!
Argo FET 100-3 Argo FET Battery Isolator Argofet 100-2 Argofet 100-3 Argofet 200-2 Argofet 200-3
3bat 100A
Maximum charge current (A) 100 100 200 200
Maximum alternator current (A) 100 100 200 200
Number of batteries 2 3 2 3
Connection M8 bolts M8 bolts M8 bolts M8 bolts
Weight kg (lbs) 1,4 (3.1) 1,4 (3.1) 1,4 (3.1) 1,4 (3.1)
Dimensions h x w x d in mm 65 x 120 x 200 65 x 120 x 200 65 x 120 x 200 65 x 120 x 200
(h x w x d in inches) (2.6 x 4.7 x 7.9) (2.6 x 4.7 x 7.9) (2.6 x 4.7 x 7.9) (2.6 x 4.7 x 7.9)