Input Values
Footing Geometry
Footing Thickness (Ft) = 305.000 mm
Footing Length - X (Fl) = 1000.000 mm
Footing Width - Z (Fw) = 1000.000 mm
Eccentricity along X (Oxd) = 0.000 mm
Eccentricity along Z (Ozd) = 0.000 mm
Column Dimensions
Column Shape =Rectangular
Column Length - X (Pl) =0.400 m
Column Width - Z (Pw) =0.300 m
Design Parameters
Concrete and Rebar Properties
Unit Weight of Concrete = 25.000 kN/m3
Strength of Concrete = 25.000 N/mm2
Yield Strength of Steel = 415.000 N/mm2
Minimum Bar Size = Ø6
Maximum Bar Size = Ø32
Minimum Bar Spacing = 50.000 mm
Maximum Bar Spacing = 500.000 mm
Pedestal Clear Cover (P, CL) = 50.000 mm
Footing Clear Cover (F, CL) = 50.000 mm
Soil Properties
85
Unit Weight = 21.000 kN/m3
Soil Bearing Capacity = 290.000 kN/m2
Soil Surcharge = 30.000 kN/m2
Depth of Soil above Footing = 1500.000 mm
Cohesion = 0.000 kN/m2
Design Calculations
Footing Size
Initial Length (Lo) = 1.000 m
Initial Width (Wo) = 1.000 m
Uplift force due to buoyancy = 77.338 kN
Effect due to adhesion = 0.000 kN
86
Area from initial length and width, Ao = Lo X Wo = 1.000 m2
Min. area required from bearing pressure, Amin = P / qmax = 3.852 m2
87
If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to
account for uplift, areas of negative pressure will be set to zero and the pressure will be
redistributed to remaining corners.
Summary of adjusted Pressures at Four Corner
Critical Load Case And The Governing Factor Of Safety For Overturning and Sliding X
Direction
88
Minimum Sliding Ratio for the Critical Load Case = 25.738
Critical Load Case for Overturning about X-Direction = 3
Governing Overturning Moment = 43.005 kNm
Governing Resisting Moment = 1214.046 kNm
Minimum Overturning Ratio for the Critical Load Case =28.231
Critical Load Case And The Governing Factor Of Safety For Overturning and Sliding Z
Direction
89
As Per IS 456 2000 ANNEX G G-1.1C
Limiting Factor1 (Kumax) = = 0.479107
DX = 0.453 m
Shear Force(S) = 268.499 kN
Shear Stress(Tv) = 275.680035 kN/m2
Percentage Of Steel(Pt) = 0.1343
As Per IS 456 2000 Clause 40 Table 19
Shear Strength Of Concrete(Tc) = 276.571 kN/m2
Tv< Tc hence, safe
90
Check Trial Depth for one way shear (Along Z Axis)
(Shear Plane Parallel to Z Axis)
DZ = 0.453 m
Shear Force(S) = 229.128 kN
Shear Stress(Tv) = 235.256029 kN/m2
Percentage Of Steel(Pt) = 0.1558
As Per IS 456 2000 Clause 40 Table 19
Shear Strength Of Concrete(Tc) = 295.961 kN/m2
Tv< Tc hence, safe
Check Trial Depth for two way shear
91
Shear Stress(Tv) = 668.326 kN/m2
As Per IS 456 2000 Clause 31.6.3.1
Ks = = 1.000
Shear Strength(Tc)= = 1250.00 00 kN/m2
Ks x Tc = 1250.0000 kN/m2
Tv<= Ks x Tc hence, safe
Reinforcement Calculation
Calculation of Maximum Bar Size along X Axis
Bar diameter corresponding to max bar size (db) = 20 mm
As Per IS 456 2000 Clause 26.2.1
92
For moment w.r.t. X Axis (Mx)
As Per IS 456 2000 Clause 26.5.2.1
Minimum Area of Steel (Astmin) = 1308.060 mm2
Calculated Area of Steel (Ast) = 1517.448 mm2
Provided Area of Steel (Ast,Provided) = 1517.448 mm2
Astmin<= Ast,Provided Steel area is
accepted
Selected bar Size (db) = Ø8
Minimum spacing allowed (Smin) = 48.000 mm
Selected spacing (S) = 68.067 mm
Smin <= S <= Smax and selected bar size < selected maximum bar size...
The reinforcement is accepted.
Based on spacing reinforcement increment; provided reinforcement is Ø8 @ 65.000 mm
o.c.
Along X Axis
93
For moment w.r.t. Z Axis (Mz)
As Per IS 456 2000 Clause 26.5.2.1
Minimum Area of Steel (Astmin) = 1308.060 mm2
Calculated Area of Steel (Ast) = 1295.608 mm2
Provided Area of Steel (Ast,Provided) = 1308.060 mm2
Astmin<= Ast,Provided Steel area is accepted
Selected bar Size (db) = Ø8
Minimum spacing allowed (Smin) = = 50.000 mm
Selected spacing (S) = 78.538 mm
Smin <= S <= Smax and selected bar size < selected maximum bar size...
The reinforcement is accepted.
Based on spacing reinforcement increment; provided reinforcement is Ø8 @ 75.000 mm
o.c.
Top Reinforcement Design
Along Z Axis
94
Minimum Area of Steel (Astmin) = 1308.060 mm2
Calculated Area of Steel (Ast) = 1308.060 mm2
Provided Area of Steel (Ast,Provided) = 1308.060 mm2
Astmin<= Ast,Provided
Steel area is accepted
Governing Moment = 75.780 kNm
Selected bar Size (db) = Ø8
Minimum spacing allowed (Smin) = 50.000 mm
Selected spacing (S) = 78.538 mm
Smin <= S <= Smax and selected bar size < selected maximum bar size...
The reinforcement is accepted.
95
Minimum Area of Steel (Astmin) = 1308.060 mm2
Calculated Area of Steel (Ast) = 1308.060 mm2
Astmin<= Ast,Provided
Steel area is accepted
Governing Moment =67.809kNm
96