Technical Data: - HA?DI
Technical Data: - HA?DI
Technical Data: - HA?DI
DI
Technical Data
400 Series 403C-15G
ElectropaK 22,9 kW @ 3000 rev/min
General installation
Type of operation and application
Designation Units Prime Stand-by
60Hz 60Hz
Gross engine power (to BSAU141A) kW (bhp) 21,7 (29.1) 23,9 (32.1)
Brake mean effective pressure kPa (lbf/in²) 575,1 (83.4) 639 (92.7)
Mean Piston speed m/s (ft/s) 9 (29.5) 9 (29.5)
ElectropaK net engine power kW (bhp) 20,7 (27.8) 22,9 (31.0)
Engine coolant flow (coolant pump ratio 1.5:1) l/min (UK gal/min) 72,3 (15.9) 72,3 (15.9)
Combustion air flow m³/min (ft³/min) 2 (70.6) 2 (70.6)
Exhaust gas flow (max) m³/min (ft³/min) 5,52 (195) 5,93 (209)
Exhaust gas temperature (max) °C (°F) 515 (959) 575 (1067)
Cooling fan air flow (zero duct allowance) m³/min (ft³/min) 73,8 (2606) 73,8 (2606)
Cooling fan air flow (0,125 kPa duct allowance) m³/min (ft³/min) 69 (2436) 69 (2436)
Energy balance
Energy in fuel (heat of combustion) kW (Btu/min) 66,9 (3807) 74,6 (4244)
Gross heat to power kW (Btu/min) 21,7 (1235) 23,9 (1360)
Energy to coolant and lubricating oil kW (Btu/min) 21,4 (1218) 23,9 (1358)
Energy to exhaust kW (Btu/min) 17,7 (1007) 19,9 (1132)
Heat to radiation kW (Btu/min) 6,3 (358) 6,9 (395)
Caution: The airflows shown in this table will provide acceptable cooling for an open power unit operating in ambient temperatures of up
to 53 °C (46 °C if a canopy fitted). If the power unit is to be enclosed totally, a cooling test should be done to check that the engine cooling
is acceptable. If there is insufficient cooling, contact Perkins Technical Service Department.
403C-15G ElectropaK, left side view
541
791
682
250
341 260 90
820
403-15G ElectropaK, front view
233 243
183 183
162 162
Ø13
MOUNTING
HOLES
354
403-15G ElectropaK, front view
233 243
183 183
162 162
Ø13
MOUNTING
HOLES
354
400 Series 403C-15G 22,9 kW @ 3000 rev/min
Cooling system Governor type ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... .Mechanical
Radiator
--face area. ... ... ... ... ... ... ... ... ... ... ... ... ... ... . 0,167 m² (1.79 ft²) Fuel Specification
-rows and materials.. ... ... ... ... ... ... ... ... ... ... .2 rows, Aluminium Density (kg/l @ 15°C) 0,835 - 0,855
-matrix density and material . ... ... ... 14.5 fins per inch, Aluminium Viscosity (mm²/s @ 40 °C) 2,0 - 4,5
-width of matrix. ... ... ... ... ... ... ... ... ... ... ... ... 334,2 mm (13.2 in) Sulphur Content 0.2% mass maximum
-height of matrix ... ... ... ... ... ... ... ... ... ... ... ... ...500 mm (19.7 in) Cetane Number 45 minimum
-pressure cap setting ... ... ... ... ... ... ... ... ... ..90 kPa (13.05 lb/in²) Specific Fuel consumption g/kWh (litres/hr)
Estimated cooling air flow reserve ... ... ... ... ... ... ... ... .. 0,125 kPa
Power rating %
Fan
-diameter .. ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...320 mm (12.6 in) 110 100 75 50
-drive ratio ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 1·1 : 1 264 (7,5) 264 (6,8) 284 (5,5) 338 (4,4)
-number of blades ... ... ... ... ... ... ... ... . .. ... ... ... ... ... ... ... ... ... 7
-material ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... Plastic Induction system
-type . ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...Pusher Maximum air intake restriction
Coolant -clean filter. ... ... ... ... ... ... ... ... ... ... ... ... ... 3 kPa (0.435 in H2O)
Total system capacity -dirty filter... ... ... ... ... ... ... ... ... ... ... . .. ... 6,4 kPa (0.928 in H2O)
-with radiator ... ... ... ... ... ... ... ... .. . ... ..5,98 litres (10.5 UK pints) -air filter type.. ... ... ... ... ... ... ... ... ... ... ... ... ... ..Dry element type
-without radiator ... ... ... ... ... ... ... ... ... ... ..2,6 litres (4.6 UK pints)
-draindown capacity ... ... ... ... ... . ... ... ..TBA litres (TBA UK pints) Lubrication system
Maximum top tank temperature ... ... ... ... ... ... ... . 110 °C (230 °F) Lubricating oil capacity
Minimum temperature to engine .. ... ... ... ... ... ... TBA °C (TBA °F) Total system.. ... ... ... ... ... ... ... ... ... ... ... . 6 litres (10.5 UK pints)
Temperature rise across engine .. ... ... ... ... ... ... TBA °C (TBA °F) Minimum ... ... ... ... ... ... ... ... ... ... ... ... ... 4,5 litres (7.9 UK pints)
Max permissible external system resistance TBA kPa (TBA lbf/in²) Maximum engine operating angles
Thermostat operation range. ... ... ... . .. ...82 - 95 °C (180 - 203 °F) -front up, front down, right side or left side ... ... ... . 35° continuous
Recommended coolant: Lubricating oil pressure
50% ethylene glycol with a corrosion inhibitor (BS 6580 :1992 or -relief valve opens . ... ... ... ... ... ... 262 - 359 kPa (38 - 52.1 lbf/in²)
ASTM D3306-89 or AS2108) and 50% clean fresh water. -at maximum no-load speed.. ... ... ... ... ... ... .. . ... ... ... ... ... ..TBA
Normal oil temperature.. ... ... ... ... ... ... ... ..... ... . . 125 °C (257°F)
Electrical System Recommended SAE viscosity
-alternator. ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... . 55 A, 12 V A single or multigrade oil must be used which conforms API-CH-4
-starter motor ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... .2 kW, 12 V or ACEA E5..
Cold start recommendations
Minimum cranking speed . ... ... ... ... ... ... ... ... ... ... .. TBA rev/min
Minimum 0W
starting Battery specifications 5W20
Grade of
temperature engine
10W30
lubricating BS3911 SAEJ537 Number 15W40
oil Cold Cold of Perkins 20W50
°C °F
start cranking batteries Type 20
amps amps needed
30
0 32 20W 420 590 1 072 40
-15 5 10W 420 590 1 072 -30 -20 -10 0 10 20 30 40 50oC
-22 -4 14 32 50 68 86 104 122oF
-20 -4 5W 540 740 1 647
Ambient temperature
W1355
Exhaust system
Maximum bending moment
Maximum back pressure .. ... ... ... ... ... ... .. 10,2 kPa (3.012 in Hg)
at rear face of block ... ... ... ... ... ... ... ... ... ... TBA Nm (TBA lb ft)
Exhaust outlet size... ... ... ... ... ... . .. ... ... ... ... ... .42 mm (1.65 in)
Publication No. TPD 1496E, Issue 1. Printed in England. ©Perkins Engines Company Limited.
Fuel system
Type of injection... ... ... ... ... ... ... ... ... ... ... ... ... Indirect injection
Fuel injection pump.. ... ... ... ... ... ... . .. ... ... ... ... ... Cassette type
Fuel injector.. ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ..Pintle nozzle
Nozzle opening pressure . ... ... ... ... ... ... ..14,7 MPa (2133 lbf/in²)
Fuel lift pump
-flow/hour . ... ... ... ... ... ... ... ... ... ... . 63 litres/hr (16.6 UK gals/hr)
-pressure .. ... ... ... ... ... ... ... ... ... ... ... ... ... ...10 kPa (1.45 lbf/in²)
Maximum suction head ... ... ... ... ... ... .. . ... ... ... ... ..0,8 m (2.6 ft)
Maximum static pressure head ... ... ... ... . .. ... ... ... ...3 m (9.84 ft)
-;HA?DI Distributed by