Nothing Special   »   [go: up one dir, main page]

Appendix 1-Geochain and ACQ Compatibility Guide (USB Drivers and Driver Signature Enforcement) July 2019

Download as pdf or txt
Download as pdf or txt
You are on page 1of 32

 

APPENDIX I ‐ GEOCHAIN COMPATIBILITY GUIDE:  
 
UPDATED July 2019 
 
Below is an overview of where we currently are with firmware and software for the Digital ASR and GSR tools 
and panels. Hope this helps clarify things. Revised Electronics compatibility guide also attached to the bottom 
of this doc. 
 
TAS‐1 
Compatible with AS270 42dB digitisers only. Maximum telemetry rate is 768kbps. It is unlikely you will still see 
one  of  these  as  most  were  upgraded  to  TAS‐2.  ACQ  no  longer  supports  TAS‐1  Operation.  Please  email 
sales@avalonsciences.com to receive a quote to exchange your TAS‐1 for latest X‐TAS. 
 
TAS‐2 
Firmware V13 or later supports AS270 and AS271 digitisers when used with ACQ 1.93 or later. 
Firmware V15 or later supports AS270, 271, 272, 273 in ASR and AS250, 251 in GSR. ACQ 2.15.2 or later is needed 
to support different digitisers in the same string as long as the Digitisers have the required minimum firmware. 
TAS‐2 with V15 firmware supports bypass capabilities in compatible tools from Ver. 2.04 ACQ.
 
XTAS and SXTAS 
Latest  addition  to  ASL  portfolio  –  please  ensure  that  you’re  running  the  latest  versions  of  the  FPGA  and 
Microcontroller code.  Current versions are FPGA version 6 for  the 16 MHz boards / FPGA version 7 for the          
32 MHz boards and microcontroller version 10 for both types of board. These will give you compatibility with all 
the previous versions of Digitiser as long as the digitiser firmware is up to date. XTAS can be used with ACQ 2.25 
for discrete recording but will produce warnings. Ver. >=4.08.9 will work better and is required if using X series 
(AS272/AS251) digitisers and/or DFU 
You can record gapless with XTAS/SXTAS, DFU, X or non X digitiser and ACQ >=4.08.9 
Firmware versions prior to micro 8/FPGA 6 will not allow HSI functionality and will cause GSP resets if the HSI 
button is selected in tool Config.   XTAS/SXTAS supports bypass capabilities in compatible tools. 
 
DFU 
Again relatively new so wise to make sure you’re using the latest version of firmware. Current firmware is FPGA 
V18, Micro V13, use with XTAS/SXTAS and X series digitisers for gapless, formatted  and discrete recording  or  
XTAS/SXTAS and non X series Digitisers for gapless and discrete recording.  
The DFU with the latest version of Firmware also has the ability to operate as a Data buffering unit for Discrete 
recording when used with all X series equipment. ACQ ver. 4.08.x has a ‘Discrete Record Planning’ button on 
the second page of the ‘Tool System’ configuration which will advise how long you can record before buffering 
of data occurs. Since this is dependent on a number of factors (number of tools, sample rate, telemetry rate, 
error control, record length etc.) it is essential to use the discrete record interactive planning tool. Firmware 
versions prior to micro 10/FPGA 17 will not allow HSI functionality and will cause GSP resets if the HSI button is 
selected in tool Config. 
 
                                          1 
 
 

 
DIGITISERS 
How and what you are recording will have a direct impact upon which version of firmware/software you need 
as a minimum. For example, shooting conventional discrete record surveys with all AS271 digitisers does not 
require the latest versions of software/firmware so there may be little point in changing from the known setup 
that you already have. The only thing you should try and achieve is to at least have all the digitiser running the 
same firmware versions. 
If  you  have  the  requirements  to  shoot  gapless,  you  should  consider  the  minimum  firmware/software 
requirements and whether all your equipment is at a level to support the operation you wish to perform. Below 
is a section from the current ‘Geochain Overview user Manual’. This has two useful information sections for 
shooting  discrete  and  gapless  surveys  which  should  give  you  all  you  need  to  know  for  the  minimum 
requirements in an easy to follow format. Something to remember is that the AS273 and AS250 share the same 
architecture in different packages 
 (ASR  –  GSR).  Likewise  the  AS272  and  AS251  share  very  similar  architecture  in  a  different  package.  The  251 
contains a power supply crowbar circuit to give additional protection to the power supply. 
 
GSP 
Be aware that the GSP has undergone some modifications over the years to deal with the increased capacity of 
the Geochain system. Refer to the section later for latest info  
The ‘Electronics Compatibility Guide’ shown at the end of this document has a more in depth review  
of the  individual Geochain sections. This has been updated to show the most recent versions of the firmware. 
 
ACQ ‐ (Always refer to the latest release notes for the latest bug fixes and firmware revisions) 
 Version 2 software will run on all Windows platforms prior to Windows 10. You should use ACQ ver. 2.13 or 
later to run on Windows 10 as the ACQ installer prior to this is incompatible with Windows 10 and difficult to 
install. Latest series 2 version of ACQ software is 2.30 
 
All version of Ver. 4 ACQ software will run on all Windows platforms. This is constantly improving so use the 
latest version possible. New installs of ACQ can trigger ‘Driver Signature Enforcement’ in various versions of 
Microsoft Windows. We do have details of how to disable this but the best method is to look it up on the Internet 
for the version of Windows that you are using. Company provided PC’s and Laptops may require Administrator 
intervention to allow you to do this. They may also have hard drive encryption software which could lock you 
out of the machine unless you either temporarily deactivate it or have the correct password (code) to get you 
back in. 
 
Ver.  4  ACQ  introduces  ACQ‐S  which  runs  in  the  background  and  should  be  transparent  to  the  user.  It’s 
responsible for writing data to disc. You may see an ACQ‐S fault come up during ACQ start‐up, usually on slower 
P.C’s. If this happens, simply cancel out of ACQ and restart. 
   

                                          2 
 
 

SUMMARY COMPATIBILITY OVERVIEW 
Analog Record Mode 
 
To perform an Analog survey you will need:
DCP 
GSP (any revision) 
Up to 2 ASR/GSR tools, fitted with DHAs (ASR‐53)
PC (Win 7/8/10) running ACQ,
Any version of ACQ can be used; no benefit is gained from using v4.x, 
 
Optional:
RSS, 
Analog Gamma. 
Analog Record Supported Features:
Feature  Supported
Surface Channels  Y (16 – 3 x Number of Tools) 
By‐pass  N
Gapless  N
Formatted  N
High Side Indicator  N
Mix and Match  N
Discrete Buffering  N
 

                                          3 
 
 

Geochain Discrete Record Mode  
 
In theory you can use any version of ACQ to perform a VSP or non‐gapless Passive Seismic survey. 
 
   
To perform a Geochain Discrete Record survey you will need: 
TAS: 
  TAS‐2 (AS‐281), current firmware v15 (see TAS‐2 Note), or,
  X‐TAS (AS‐283), current Micro v10, FPGA (v6 or v7 depending 
on oscillator), or,
  Slim TAS (AS‐260), current firmware v17, or, 
  Slim  X‐TAS  (AS‐261),  current  Micro  v10,  FPGA  (v6  or  v7 
depending on oscillator,
Up to 62 Seismic Receivers:  
  ASRs with AS‐270 digitizers, minimum firmware v13, or v16 
for mix and match, and/or,
  ASRs with AS‐271 digitizers, minimum firmware V13, or v16 
for mix and match, and/or,
  ASRs  with  AS‐272  digitizers,  minimum  Micro  v7,  FPGA  v6, 
and/or,
  ASRs with AS‐273 digitizers, minimum firmware v33, and/or, 
  GSRs with AS‐250 digitizers, minimum firmware v33, and/or, 
  GSRs with AS‐251 digitizers, minimum Micro v7, FPGA v6,
VRS: 
  VRS, or
  Slim VRS
Power Supply: 
  GPP, or,
  GMP (use ACQ >= 4.x.x), 
Rev 2, with LRX2 card, or LRX2B if using by‐pass tools, USB2b 
GSP  
preferred.
PC   (Win 7/8/10) running ACQ.
ACQ  Any Version (Discrete buffering requires >= 4.x.x)
Optional:   
  For discreet buffering you require all X series and a DFU (AS‐
284) minimum Micro v10, FPGA v17  ‐  or 
  For discreet buffering you require all X series and a Slim DFU 
(AS‐262), minimum Micro v10, FPGA v17 
  RSS,
  Gamma,
  TCU,
  Slim Gamma,
  Slim TCU (use ACQ 4.x.x).

                                          4 
 
 

Geochain Discrete Record Supported Features:
Feature  Supported
Surface Channels  Y 
By‐pass  Y (with AS273/272/250/251 digitizers) 
Gapless  N
Formatted  N
High Side Indicator  Y (with X‐Series X‐TAS AS‐272/251 digitizers) 
Mix and Match  Y
Y (with X‐series X‐TAS AS‐272/251s, with DFU) and 
Discrete Buffering  ACQ >=4.x.x)
 

                                          5 
 
 

Geochain Gapless Record Mode 
 
To perform a Geochain gapless microseismic monitoring survey you will need:
TAS: 
X‐TAS (AS‐283), with current firmware Micro v10, FPGA (v6 or v7 depending on 
  oscillator or, 
Slim X‐TAS (AS‐261), with current firmware Micro v10, FPGA (v6 or v7 depending 
  on oscillator, 
 
Buffering: 
  DFU (AS‐284), with minimum Micro v13, FPGA v17, or,
  Slim DFU (AS‐262), with minimum Micro v13, FPGA v17,
 
Seismic Receivers:  
  ASRs with AS‐270 digitizers, minimum firmware v16, and/or, 
  ASRs with AS‐271 digitizers, minimum firmware v16, and/or, 
  ASRs with AS‐272 digitizers, minimum Micro v7, FPGA v6, and/or, 
  ASRs with AS‐273 digitizers, minimum firmware v31, (preferably v33) and/or,
  GSRs with AS‐250 digitizers, minimum firmware v31, (preferably v33)  , and/or,
  GSRs with AS‐251 digitizers minimum Micro v7, FPGA v6, 
 
VRS  VRS  or SVRS 
 
 
Power Supply:  GPP, or, 
  GMP(use ACQ >= 4.x.x), 
 
GSP   Rev2.x, with LRX2B and USB 2b card,
PC   (Win 7/8/10) running,
ACQ   > 4.x.x 
Optional: 
  Analogue or Digital Gamma 
  Slim/ Standard TCU
 
   
 
   

                                          6 
 
 

 
Geochain Gapless Record Supported Features: 
Feature  Supported
Surface Channels  N
By‐pass  Y (with AS273/272/250/251 digitizers) 
Gapless  Y
Formatted  Y (All X series and DFU fitted) 
High Side Indicator  Y (with X series TAS and AS‐272/251 digitizers) 
Mix and Match  Y
Discrete Buffering  Y (All X Series and DFU) and ACQ >=4.3 
 

 
 

   

                                          7 
 
 

ELECTRONICS COMPATIBILITY DETAILED OVERVIEW 
TAS‐1  TAS‐2 XTAS (AS283)
Compatible with AS270  With firmware v13 or later TAS‐2 is compatible with  In conjunction with a DFU (AS284) and 
42dB digitisers only.  AS270 and AS271 digitisers. ACQ 1.93 or later is  non X series digitisers, the XTAS supports 
Maximum telemetry rate is  needed for AS271 support.  true gapless recording.  
768kbps. 
  With all X‐digitisers (AS272 or AS251), 
  formatted mode is also available.  The 
With firmware v15 or later TAS‐2 is compatible with all 
latest version of 4.x.x ACQ should be 
Can be upgraded to TAS‐2.  current digitisers AS270, AS271, AS272 and AS273 in 
used for gapless or formatted recording. 
Early TAS’s had an  ASR tools and AS250, AS251 in GSR tools. ACQ 2.15.2 
Gapless mode can be used with XTAS, 
aluminium transformer  or later is needed to support mixing different digitisers 
DFU and any digitisers. Full formatting 
block. This can be replaced  in the same toolstring. Digitisers need to have recent 
capability and improved telemetry are 
by the current stainless  firmware to support mixing (see below). 
 
steel version.
 
available when all downhole equipment 
is X‐series. 
Current Firmware version is v15   X‐TAS is fully backward compatible with 
TAS‐2. 
Current firmware for FPGA is v7  – there 
are two versions of v7 for 16 and 32MHZ 
 
oscillators.   Micro ver. 10

 
 
DFU (AS284) 
The data formatting unit, DFU, is an addition to the Geochain system intended to provide gapless recording capability and (with X 
digitisers) improved telemetry functionality (Formatted). DFU connects below an XTAS and can only be used with an XTAS. The 
latest version of 4.x.x ACQ should be used for gapless or formatted recording.  
Current firmware is FPGA ver. 18  Micro ver. 13       ‐       Minimum firmware is FPGA ver. 17  Micro ver. 10 

 
   

                                          8 
 
 

ASR 
AS270 42dB  AS271 54dB  AS273  AS272 (X‐digitiser) 
AS270 is the original Geochain  AS271 54dB digitisers were  AS273 digitisers have bypass  AS272 digitisers have bypass 
digitiser. It can be used with  introduced in response to the  functionality which resets  functionality which only 
TAS‐1, TAS‐2 or XTAS’s  requirement to detect very  when power is cycled to the  resets when a reset codes 
Generally AS270’s will be used  small signals for passive  tool. ACQ 2.12 or later is  from ACQ is sent to the tool. 
in a toolstring which contains  monitoring applications. They  needed for AS273 support.  They will also go into bypass if 
only AS270 digitisers. The  can be used with a TAS‐2 with  not enumerated by the TAS 
 
difference in gain compared  v13 or later firmware or  within 5 mins of powering up. 
to other types of digitiser  XTAS’s. ACQ 1.93 or later is  AS273 with v25 or later 
AS272 digitisers support:‐ 
renders them incompatible.  needed for AS271 support.  firmware supports toolstrings 
Formatting (They are 4MB ITC 
with a mixture of digitisers. 
    data capable). mix’n’match 
ACQ 2.15.2 or later is needed 
and are HSI capable when 
With firmware v16 AS270  AS271’s with firmware v16 or  for mixed toolstring support.  
used with an XTAS. 
digitisers can technically be in  later can be used in a mixed 
AS273 digitisers would 
a mixed toolstring (with a  toolstring with AS273  In order to use the formatting 
normally be deployed in the 
TAS‐2 v15 or later). However,  digitisers and AS250 digitisers  capability, all digitisers in the 
upper tools of a mixed string. 
the gain difference will  (in GSR tools). Most  toolstring must be X‐series. X‐
Tools below could be fitted 
generally be considered  commonly AS271’s would be  TAS and DFU are also 
with either AS250 digitisers 
unacceptable.  deployed below tools fitted  mandatory for formatting to 
(bypass capable GSR tools) or 
with AS273 digitisers. Tools  work. 
  AS271 digitisers (ASR tools). It 
fitted with AS273 would have 
is inadvisable to deploy 3”  AS272’s can be used in 
Current  firmware version is  bypass functionality. TAS‐2 
ASR tools below 1 11/16” GSR  toolstrings with earlier 
v18  fitted with v15 or later 
tools so the lower digitisers in  digitisers and TAS’s but 
firmware is needed for mixed 
the string would be  formatting capability will not 
toolstrings and bypass 
AS250/AS251 or AS271/AS272  be available. 
support. 
but probably not a mixture of 
 The latest version of 4.x.x 
  the two. 
ACQ should be used for 
Current  firmware version is  Current preferred firmware  formatting capability. 
v18  version is v33 to solve issues 
Current firmware is FPGA ver. 
when using at low temps 
6    Micro ver.  7  
FPGA ver. 3 had a monitor 
scaling issue and should be 
updated as soon as possible.  
Compatible sensor cartridges:  Compatible sensor cartridges: Compatible sensor cartridges:  Compatible sensor cartridges:
ASR‐38 Gimbal geophone  ASR‐223, ASR‐225 & ASR‐232  ASR‐223, ASR‐225 & ASR‐232  ASR‐223, ASR‐225 & ASR‐232 
cartridge.  dual fixed geophone  dual fixed geophone  dual fixed geophone 
cartridges.  cartridges.  cartridges. 
ASR‐153 single fixed 
geophone cartridge.  ASR‐227 quad geophone  ASR‐227 quad geophone  ASR‐227 quad geophone 
cartridge.  cartridge.  cartridge. 

   

                                          9 
 
 

Slim TAS (AS260)  Slim XTAS (AS261) 
STAS is generally only used with GSR tools fitted with AS250  Slim XTAS aka SXTAS can be used with a SDFU (AS262) to 
digitisers. Firmware v15 or later supports bypass operation.  support true gapless recording for a Geochain Slim toolstring. 
The latest version of 4.x.x ACQ should be used for gapless 
 
recording. SXTAS and SDFU can be used with any digitisers. 
Although it is technically possible to use ASR tools with a Slim 
 
TAS it is operationally inadvisable. The slim TAS is not 
mechanically strong enough to support the use of heavy ASR  SXTAS and SDFU support X‐series digitisers AS251. Full 
toolstrings.  formatting capability and improved telemetry are available 
when all downhole equipment is X‐series. 
 
 
Current  firmware version is v17 
SXTAS is fully backward compatible with STAS. 
Current firmware is FPGA v7. There are two versions of v7 
depending on whether you have a 16 or 32MHz oscillator.   
Micro ver. 10 , minimum requirements should be FPGA ver. 6       
Micro ver. 8 

SDFU (AS262) 
The slim data formatting unit, SDFU, is an addition to the Geochain Slim system intended to provide gapless recording capability 
and (with X digitisers) improved telemetry functionality (Formatted). SDFU connects immediately below an SXTAS and can only be 
used with an SXTAS. The latest version of 4.x.x ACQ should be used for recording.  
Current firmware is FPGA ver. 18  Micro ver. 13  ‐    Minimum firmware is FPGA ver. 17  Micro ver. 10 

GSR 
AS250  AS251 (Slim X‐digitiser) 
AS250 digitisers have bypass functionality which resets when  AS251 digitisers have bypass functionality which will only reset 
power is cycled to the tool. ACQ 2.04 or later is needed for  when a reset code from ACQ is sent to the tool. They will also 
AS250 support.  go into bypass if not enumerated by the TAS within 5 mins of 
powering up. 
AS250 with v25 or later firmware supports toolstrings with a 
mixture of digitisers. ACQ 2.15.2 or later is needed for mixed  AS251 digitisers support:‐ Formatting (They are 4MB ITC data 
toolstring support.  capable). mix’n’match and are HSI capable when used with an 
SXTAS. In order to use the formatting capability, all digitisers in 
It is not advisable to deploy 3” ASR tools below 1 11/16” GSR 
the toolstring must be X‐series. SXTAS and SDFU are also 
tools so AS250 digitisers would be deployed in the lower tools 
mandatory for formatting to work. 
of a mixed toolstring. 
AS251’s can be used in toolstrings with earlier digitisers and 
 
TAS’s but only Discrete recording will be available. 
Current preferred firmware version is V33 to solve issues when 
The latest version of 4.x.x ACQ should be used for recording. 
using at low temps.  V31 is acceptable  
Current firmware is FPGA ver. 6   Micro ver.  7  
FPGA ver. 3 had a monitor scaling issue and should be updated 
as soon as possible. 

Compatible sensor cartridges:  Compatible sensor cartridges: 
GSR‐222 quad geophone cartridge.  GSR‐222 quad geophone cartridge. 

 
 
                                          10 
 
 

GSP Modules 
Backplane  GSP’s prior to serial number 100 were fitted with a Mark 1 backplane. 
GSP’s from serial number 100 onwards are fitted with a mark 2 backplane which provides support 
for higher data throughput. If more than 16 tools at 1ms sampling (768kbps) are required the 
backplane of the GSP should be upgraded to Mark 2. 
Looking at the back of the GSP, if the module in the rightmost slot is an LRX module, the backplane 
is Mark 1. If the module in the rightmost slot is a TSG module the backplane is Mark 2. 
CPU  Early GSP’s were fitted with a CPU1 module. 
From 2006 onwards, GSP’s have been fitted with CPU2 modules. CPU2 added GPS time stamp 
support and the depth encoder interface to support gamma logging. CPU2 or later is needed to fully 
support TAS‐2 and USB2 or later. 
If the CPU module has two D9 connectors on the end plate it is a CPU2, CPU1 modules without the 
D9 connectors are the original CPU’s. 
USB  Early GSP’s were fitted with a USB module and a DSP module. In 2007 the functionality of these two 
modules was combined in the USB2 module so GSP’s with a USB2 module do not have a DSP 
module. USB2 is needed for support of telemetry rates higher than 768kbps. USB2 requires that the 
GSP is fitted with CPU2 or later CPU module. 
A small number of GSP’s were shipped with a combination of USBx and DSPx modules. If any of 
these are still in use they should be upgraded to USB2. 
In order to enable a GSP to be used for gapless recording or formatted mode the USB module must 
be version USB2b. Any existing USB2 module can be upgraded to USB2b by re‐programming the 
Firmware. 
DSP  Early GSP’s were fitted with a DSP module. Please read the USB section for more information on 
these. 
LRX  Early GSP’s were fitted with an LRX module. This was superseded in 2004 by LRX2. Any GSP’s still 
fitted with an original LRX module should have it replaced with an LRX2 asap.  
To support the bypass capability of AS273, AS250 and X‐series digitisers, the firmware of the LRX2 
has been updated. When the firmware is updated the module is designated LRX2b and the label on 
the end plate is changed accordingly. If a GSP is to be used with bypass capable digitisers the LRX2 
must be updated to LRX2b to support bypass functionality. LRX2b is also mandatory to use 
formatted recording mode (because X‐series digitisers also have bypass capability). 
Some earlier chassis contained LRX2 boards that could not be updated. To upgrade these chassis to 
LRX2b, the board must be replaced. 
Programming GSP Modules 
  There is a special adapter that you can plug any GSP module into. You plug the adapter into the 
mains and then the module is powered up. You access the programming port through a header on 
the module. There are a couple of different programmers used depending on the chip family. Each 
of the programmers plugs into a PC via USB and has a custom connector to connect to the GSP 
module programming port. Software is run on the PC which transfers the appropriate executable to 
the module and verifies the transfer. You then function test the module back in the GSP. 

 
                                          11 
 
 

FIRMWARE RELEASE NOTES 
AS251 (X‐GSR) & AS272 (X‐ASR) DIGITISER FIRMWARE 
MICROCONTROLLER 
Revision  Date  Notes 
1.0  30/04/2015  Initial revision 
2.0  17/11/2015  Fixed bug in selection of ADC input in EPULSE, SINE and DC tests. 
3.0  03/12/2015  Adjusted ADC sample point to align with surface channels 
4.0  01/03/2016  1) Fixed bug in enumeration which limited enumeration to 48 tools. 
2) Added updating of watchdog in FPGA on driving of arm/motor H bridge. Watchdog in 
FPGA will remove drive from H bridge unless updated within 100mS 
5.0  06/07/2017  Added lifetime stats to eeprom. Added extra debug commands 
6.0  09/11/2017  Set damping value based on tool type 
7.0  16/03/2018  Added ResetAllStatusData debug message to allow the lifetime status information 
stored in EEPROM to be reset. Added Serial Number and Enumeration Tool Id to the 
status information reported during formatted recording. This release is available for 16 
and 32MHz versions of the boards. Be sure to select the correct version for the board. 
 
FPGA 

Revision  Date  Notes 


1.0  19/11/2015  Initial release  
2.0  11/12/2015  First release to production for use in deliverable tools  
Timeout features added to prevent motor overrun. Serial comms made more robust in 
3.0  07/03/2016 
motor noise. Two variants exist, 16MHz and 32MHz. 
4.0  07/07/2017  Fixed monitor mode bug, previous version was oversensitive when used with quad packs.
The clock divider is configured by fitment / non fitment of Resistor. 
For AS251 this is R420 
For  AS272  a  wire  ended  resistor:  RES‐RC55‐1k;  should  be  fitted  between  T406  and 
T605(0V). 
Fitted = 16.384MHz Oscillator, Not fitted = 32.768MHz Oscillator. 
Project, configuration and pin mapping files added to enable build for the AS251B digitiser.
5.0  10/08/2017  Selectable High/low gain bug fix  
6.0  05/03/2018  VRS Motion Sensor bug fix.  
 
 
 
 

                                          12 
 
 

 
 
 

AS270 (ASR) & AS271 (ASR) DIGITISER FIRMWARE 
Microcontroller only – No FPGA 
Revision  Date  Notes 
18.0  15th Sept 2015   Store 3 copies of EEPROM data to avoid problems with EEPROM corruption.  
 
 
 
 
AS250 (GSR) & AS273 (ASR) DIGITISER FIRMWARE 
Microcontroller only – No FPGA 

Revision  Date  Notes 


34.0  25th April 2016  Built with auto arm close disabled (for NAM tools only) 
33.0  25th April 2016  Modified temperature sensing function to correctly report sub‐zero  
Temperatures. Modified Phase Locked Loop function to enable operation at sub‐zero 
temperatures  
32.0  17th March 2015  Rebuilt for AS250B with auto arm close disabled (for NAM tools only) 
31.0  29th Oct 2014  Modified ICP interrupt to solve compatibility problem with AS270/1 when generating 
test signals.  
30.0  14th Oct 2014  Modified EEPROM Storage to help prevent serial number corruption.  
29.0  9th Apr 2014  Modified ADS1282 start‐up parameters to conform with data‐sheet  
28.0  4th Mar 2014  Updated all test signal levels to be similar to AS270/1  
27.0  10th Feb 2014  Fixes to solve arm problems in large strings  
26.0  10th Feb 2014  Special build for Shell Magicman tools with arm auto‐close feature disabled  
25.0  20th Jan 2014  Fixed timing of test modes to align with AS270/1 digitisers  
 
   

                                          13 
 
 

AS261 (SLIM XTAS) & AS283 (XTAS) FIRMWARE 
Microcontroller  
Revision  Date  Notes 
01  30/04/2014   Initial release  
02  20/05/2014   Added new command number 148 to turn on MTX ramp test in TAS FPGA. 
03  08/07/2014   Changed SPI interface to FPGA to use mode 0 transfers. 
04  08/07/2014   Added Gray coding 
05  01/10/2014   Fixed problem with switching between samples as intervals greater than 2mS. 
06  12/11/2014   Moved non‐volatile settings back into EEPROM. There have been instance of whole of 
FLASH becoming corrupt this MAY be due to previous move of non‐volatile settings into 
FLASH. Now 3 copies of data to try and avoid corruption problems. 
07  03/02/2015   Added commands to set TAS symbol delay.  
Corrected error in writing symbol  
Added debug reporting of temperature 
08  28/10/2015   Support for formatting and high side indicator 
09  07/07/2017   Added temperature stats to eeprom. Added extra debug commands 
10  16/03/2018  Added ResetAllStatusData debug message to allow the lifetime status information 
stored in EEPROM to be reset.  This release is available for 16 and 32MHz versions of 
the boards. Be sure to select the correct version for the board. 
 
FPGA 

Revision  Date  Notes 


01  28/04/2014  Initial release  
02  Not Released  Engineering Development  
03  Not Released  Engineering Development  
04  Not Released  Engineering Development  
05  02/02/2015  Major change to PLL, tested with ACQ 3.12 
(This  version  is  for  boards  with  16Mhz  Oscillators)  MRX  command  extractor  delay 
06  27/03/2015  changed so that the time to start a recording now matches the XTAS  
(This  version  is  for  boards  with  32Mhz  Oscillators)    MRX  command  extractor  delay 
07  26/03/2018  changed so that the time to start a recording now matches the XTAS  
 
   

                                          14 
 
 

AS284B DATA FORMATTING UNIT (DFU) & AS262B (SDFU) FIRMWARE 
Microcontroller  
Revision  Date  Notes 
01  30/04/2014  Initial release  
02  20/05/2014  1) Added release of FPGA power supply voltage pin to allow FPGA programmer to set 
voltage for programming.  
2) Removed timeouts in enumeration, DFU now waits in enumeration until 1st non‐
enumeration command received.  
03  08/07/2014  Changed SPI interface to FPGA to use mode 0 transfers.  
04  07/10/2014  Moved non‐volatile data into FLASH memory  
05  23/10/1014  Added support for formatting   
06  12/11/2014  Moved non‐volatile settings back into EEPROM. There have been instance of whole of 
FLASH becoming corrupt this MAY be due to previous move of non‐volatile settings into 
FLASH. Now 3 copies of data to try and avoid corruption problems.  
07  17/12/2014  Added support for formatting registers in FPGA.  
08  03/02/2015  Added debug control of i/o pins and reading of temperature  
Added control of sending status words and fixed bug in writing default status values to 
FPGA RAM.  
09  28/10/2015  Added support for formatting.  
Added support for high side indicator.  
10  09/03/2016  Added support for DBU mode.  
12  06/07/2017  Added lifetime stats to eeprom. Added extra debug commands  
13  16/03/2018  Added ResetAllStatusData debug message to allow the lifetime status information 
stored in EEPROM to be reset. .  This release is available for 16 and 32MHz versions of 
the boards. Be sure to select the correct version for the board. 
 
FPGA 
Revision  Date  Notes 
06  02/02/2015  Initial release based on 3001‐05 but now built for the BGA variant  
07  27/03/2015  Increased SI check guard band.  
16  11/11/2015  1st release of formatting DFU  
17  04/03/2016  Added DBU mode  
18  09/01/2019  Added clock divider and built version for both 16.384MHz and 32.768MHz oscillators.

 
   
                                          15 
 
 

 
Procedure for upgrading firmware for Digitiser/TAS/DFU 
There are now three types of programmable device in use in our electronics modules.  

Microcontroller, CPLD and FPGA. Downhole tools require access to the programming port for the device while the 
module is powered on and different programmers are used for the different devices. For all, you need to remove the 
flask to get access to the programming ports. You power the module using a bench top power supply connected to a 
couple of pins on the 22‐21 connector on the end of the module. Software on the PC transfers the executables via the 
programmer. Digitisers/TAS and DFU’s require that you have the skills and jigs for disassembly and re‐assembly of the 
flask. This is not difficult but it is easy to get wrong. The later hermetically sealed versions have additional procedures for 
drying the molecular sieve and re‐installing whilst avoiding absorption of atmospheric moisture. The latest X‐series 
AS272/AS251 digitisers with High Side Indicators (HSI) are particularly troublesome as the HSI needs recalibrating after 
flask disassembly.  This requires a heated calibration jig to calibrate at temperature. 

 
 
 
ACQ Software Suite Release Notes for Version 4 
 
4.10.2 February 2019 

Improvements to the reliability and error handling of Gapless Recording. 

GSP code (loaded automatically) is V8 

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 

4.10.1 December 2018 
This version changes the MIRF specification to MIRF 7. 

Minor bug fixes regarding journal entry length. 

Change to MIRF specification to use 0 to 360 for HSI roll (rather than ‐180 to +180). 

Ensure that the Hint button is always shown on the New Depth dialog. 

Show the progress dialog when taking Analog records. 

Ensure that downhole channels always have a valid descriptor. 

Show the units (lbs) when logging Tension to the journal. 

Fixed coding error that prevented Tertiary Storage files from being created. 

 
                                          16 
 
 

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 

4.10.0 August 2018 
Fixed bug that could cause us to lose data during Gapless (not Formatted) recording. 

Fixed bug that results in incorrect channel assignments for SURFACE channels in discrete recording. 

Fixed bug that caused no RCD files to be created when performing discrete recording with the last Receiver in Bypass. 

Fixed potential bug when using TAS2 with X‐Receivers. 

Removed long delay (several seconds) before starting auto‐recording (discrete). 

Continuous Recording (Gapless and Formatted) can now be started with Receivers in Bypass. 

The reading from the Depth Encoder (if fitted) will be used as the starting depth on the "New Depth" dialog when selecting Discrete 
or Continuous recording. 

Improvements to try to fix “Problem finding LRX gain at 256Ksps, please try again” and related issues (including record number 
problem): 

4.09.9 April 2018 
DC Offsets for Surface channels were incorrectly set to Zero when an X‐Tool System was used. 

Some work has been done to attempt to fix an intermittent failure to find the LRX Gain at 256KSymbols/second. 

Note: There is a known bug in this version of ACQ that will result in no data file being created during discrete recording if the last 
tool is in Bypass. 

This will be fixed in a release of ACQ in the very near future. 

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 

4.09.8 Unreleased 
Some RCD files recorded in a Test Mode incorrectly indicated that they were recorded with Test Mode set to TEST_OFF. 

Source positions in RCD files were corrupted when using a Source Fix messages from extrnal source positioning system. 

RCD files were corrupt when recording TAS ZERO or TAS SINE test modes with a DFU in DBU‐Buffering mode. 

When recording in Gapless or Formatted modes, the timing of the Periodic Tool Reset (if selected) was inaccurate. 

When recording in Gapless or Formatted modes, the display would incorrectly show a large DC offset on all channels after a Periodic 
Tool Reset. 

When recording in Gapless or Formatted modes, the DFU status data would be incorrect in the journal after a Periodic Tool Reset. 

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 

4.09.7 Dec 2017 
This build improves Monitor Mode reliability, speeds up discrete recording when taking short (one minute or less) records, 

Improves reliability of continuous recording and removes some debug text from the journal. 

                                          17 
 
 

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 

4.09.6 Nov 2017 
This build adds the ability to set the file format for the Tertiary output when recording.  The user can select from MIRF (default), 
SEG2 and Avalon SEGY 

Note: There is a known bug in this version of ACQ that will result in no data file being created during discrete recording if the last 
tool is in Bypass. 

This will be fixed in the next release of ACQ in the very near future. 

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 

4.09.5 Oct 2017 
This build fixes an issue with HSI orientation of AS251s (Slim X‐tools). 

Note: There is a known bug in this version of ACQ that will result in no data file being created during discrete recording if the last 
tool is in Bypass. 

This will be fixed in the next release of ACQ in the very near future. 

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 

4.09.4 Sep 2017 
This build fixes a problem that caused data corruption following a periodic reset during Continuous recording. 

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 

4.09.3 Aug 2017 
This build combines the 4.08.9 build (HSI fixes) with 4.09.2 (RSS2 – 3D / Walkaway Mode). 

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 

4.09.2 Jun 2017 
This build incorporates some fixes to RSS2 ‐ 3D / Walkaway mode. 

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 

4.09.1 Jan 2017 
This build incorporates RSS2 ‐ 3D / Walkaway mode into the ACQ Software Suite. 

                                          18 
 
 

ACQ Software Suite Release Notes for Version 2 
 
2.30 Build June 2019 
 
It fixes a bug causing corruption in the journal when reporting certain tool‐types during Match Cable. 
It prompts the user to change channel assignments after configuring the number of tools in an Analog job. 
It also improves ARM operation reliability in the presence of telemetry errors. 
 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.29 Build Jan 2016 
 
It fixes the bug introduced in 2.27, XASRs were not coming out enhanced bypass mode upon a tool reset 
Also made the Arm operation stop window smaller so it doesn't obscure the monitor window. 
 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.28 Build Jan 2016 
 
It performs a tool reset if an arm open/close operation times out, in case the digitiser micro‐controller has crashed, 
to prevent motor burn out. 
 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.27 Build Jan 2016 
 
It allows for tools which stay permanently in by‐pass mode, ie.AS‐272s and AS‐251s to be taken out of by‐pass mode, 
upon 
Performing a tool reset. 
 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.26 Build Dec 2015 
 
It provides support for X series hardware i.e. the XTAS(AS‐283), SXTAS(AS‐261), XASR(AS‐272) and XGSR(AS‐251). 
 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.25 Build Sept 2015 
 
It fixes the library dependencies for Mirf Info 
 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.24 Build Sept 2015 
 
This build constitutes version 2.24 of the ACQ Software Suite. 
It fixes problems with the folder selection dialog used in MirfCopy and other ancillary applications.  
 
 
                                          19 
 
 

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.23 Build Sept 2015 
 
Changes to the RSS application only. 
Enhancements to the data logged after each shot. 
The transfer of slave log data to the master after each shot. 
Graphical display of the log data at the master and slave. 
Log data is now stored in named folders. 
Log data is now stored in the same file, regardless of how many times you enter RUN mode. 
New shot data can be appended to existing logs if you select he same log folder on re‐starting the application. 
You can test fire Remote sources as Master in RUN mode 
You can now test fire local sources as a Slave in RUN mode. 
Improvements to holding mode options 
Improvements to status bar readability on Notebooks 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.22 Build July 2015 
 
This build includes MIRF Info in the installer. 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.21 Build May 2015 
 
This build fixes the printing problems of the previous releases 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.20 Build May 2015 
 
This build constitutes fixes the backwards compatibility problem where RCD files produced by previous versions of Acq 
could not be replayed 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.19 Build May 2015 
 
This build corrects the time stamping of records with a DBU fitted 
Fix TCU problem 
Set offset before sending command to go into monitor mode 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.18 Build Mar 2015 
 
This build corrects the time stamping of records with a DBU fitted 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.17 Build Mar 2015 
 
This build constitutes writes the GPRMC message to the Mirf header (at word 55) 
 
 
 

                                          20 
 
 

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.16 Build Oct 2014 
 
This build addresses issues with arm operation on large tool strings plus ACQ crashes with tools going into bypass 
on large tool strings. 
The Automatic sequential closing of arms, 20 tools up from the bottom of the string has now been removed due to 
Firmware upgrades in digitisers. 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.15.5 Build Feb 2014 
 
This build wraps up a few issues that have been spotted as a result of more comprehensive testing of the 2.15.4 build, 
namely: 
 
1. Improved warnings after Match Cable for out‐of‐date firmware 
2. Improved messaging when tool goes into by‐pass mode, the specific tool number is specified, 
3. Fixed error where an LRX Card 2B warning was being generated for non‐by‐pass toolstrings 
4. Automatic sequential closing of arms, 20 tools up from the bottom of the string now works. 
5. High Gain mode is now selected again for the Noise Test. 
6. Serial numbers are no longer retained upon changing jobs, 
7. Several monitor mode fixes display have gone in as incorrect data was being shown when a tool has been by‐passed. 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.15.4 Build Feb 2014 
 
This build fixes the following: 
1. ACQ crash when opening arms. 
 
Note: 
For 273/271 mix and match operation both 'High‐Gain' mode and 'Damping Disconnect' should be selected 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.15.3 Build Feb 2014 
 
This build fixes the following: 
1. Incorrect gain levels between 273s and 271s 
2. Arm opening/closing is now always sequential 20 tools up from bottom of string 
3. Arm motor currents now displayed correctly for tools below tools which are in by‐pass mode  
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.15.2 Build Jan 2014 
 
This is the ACQ build which fully supports Mix and Match. 
You can now have toolchains with any combination of AS‐270, AS‐271, AS‐250 and AS‐273 tools. 
Instead of selecting 'GEOCHAIN‐ASR', 'GEOCHAIN‐ASR273' or 'GEOCHAIN‐GSR', you now select just the generic 
'GEOCHAIN' option 
After each 'Match Cable' operation, ACQ will do its best to understand what tools are connected and take the 
appropriate action.  
ACQ will generate a warning if: 
1. You place FAT tools below slim tools 

                                          21 
 
 

2. You have both AS‐270s and AS‐271s in the same string 
3. If you place tools which support by‐pass mode, ie. AS‐250s or AS‐273s below tools which don't, ie. AS‐270s or AS‐271s. 
4. If you have out‐of‐date firmware in any of the tools. 
   If you are using toolchains which support by‐pass mode, ie. AS‐250s or AS‐273s then the  
   TAS firmware must be at least V15,  
   AS‐250 and/or AS‐273 digitiser firmware must be at least V25. 
   AS‐270 and/or AS‐271 digitiser firmware must be at least V16. 
5. All digitisers of the same type must be at the same firmware revision level 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.14.3 Build Oct 2013 
 
It fixes the error whereby the downhole and uphole data were out of sync by 2 samples for ASR AS‐270/271 tools 
The font size in the journal has also been made larger, to improve readability 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.14.2 Build Oct 2013 
 
It introduces support for ASR AS‐273 tool system. 
It also includes support for sequential arm opening and closing. 
It also supports mixing AS‐273 and GSRs in the same toolstring. 
It has fixed an ACQ crash when using the TAS sine test at 4msecs 
It has fixed problems with the wrong amount of data being sent when data‐disabled tools go into by‐pass mode. 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.13 Build July 2013 
 
It fixes several issues related to the use of 'High‐Gain' mode. 
It can now only be selected for GSRs, also when doing a GSR 'Noise' test the correct scale values are displayed 
when replaying records. 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.12 Build May 2013 
 
It fixes the error of GSR tools reporting their status during monitoring. 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.11 Build April 2013 
 
It fixes the error of ASR tools being reported as GSR tools on Monitor display and in journal. 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.10 Build March 2013 
 
It fixes the error of the missing 'MonitoringCoeffs.dat' file when performing a Match Cable for the first time when 
using GEOCHAIN‐GSR tools. 
 
 
 
 

                                          22 
 
 

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.09 Build March 2013 
 
Changes in this version of software include: 
 
1. As part of By‐Pass mode, serial numbers are now requested at the lower 'monitoring' telemetry rate, at the 
start of each record.  
Unreliable serial number data was causing bad records/channels when working in By‐Pass mode. 
2. In 'passive monitoring' mode when 'error control' in on, a re‐equalisation is now only performed whenever 
The telemetry rate drops below 99.95%. 
3. Any telemetry rate > 99.95% is now reported as 'OK'. 
 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.08 Build January 2013 
 
1. RSS ‐ Modify the Trace Identification Code in the gun trace headers of SEG Y files from 0 (Unknown) 
         to 7 (Timing). 
         NB Hydrophone traces are still given the ID code of 9 (Near‐field gun signature) 
 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.07 Build November 2012 
 
1. ACQ ‐ Resolve issues surrounding the use of 8 or more GSR's in a tool chain 
         NB If 8 or more tools are in the chain then changing the telemetry settings so values other than  
         those suggested by Acq can stop the software working correctly 
2. ACQ ‐ Changed toolbox password 
3. ACQ ‐ Added FIXED_QUAD option 
4. ACQ ‐ Amended warning for GSR firmware 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.06 Build June 2012 
 
1. ACQ ‐ Fix tool arm operation for ASR tools 
 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.05 Build June 2012 
 
1. RSS ‐ Fixed problem whereby 2.4s hydro delay was not maintained when more than one hydrophone was being used. 
2. RSS ‐ New manual 
3. RSS ‐ New installer, you can now select which Avalon applications to install. 
 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.04 Build May 2012 
 
1. ACQ ‐ Incorporate By‐pass Mode  
2. ACQ ‐ Incorporate VibPro fix 

                                          23 
 
 

‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.03 Build May 2012 
 
1. RSS ‐ The problem with the RSS resetting itself occasionally has been fixed. 
2. RSS ‐ The Radio sync time has been lengthened so the number of 'missed' records at the Master should be greatly 
reduced. 
3. RSS ‐ The 'Sync Guns From Hydrophone' functionality has been simplified and streamlined following customer 
feedback,  
In particular a 'Fast Sync' button has been introduced on the main window. 
4. RSS ‐ Further MMI enhancements have been implemented, with the aim of making the RSS simpler to use. 
5. Configuration of the 'Sync From Hydrophone' feature has been moved to a separate 'Configure' ‐‐> 'Sync From Hydro' 
option on the menubar, rather than being presented each time the sync option is invoked. 
6. The 'Gun Configuration' dialog has been simplified, an 'Advanced' options drop‐down has been created and the 
'Search Window' options have been removed altogether. 
7. The 'Current Loop Calibration' feature has been renamed as 'Configure' ‐‐> 'Transducers' on the menubar, users can 
now optionally add a 'Description' to the transducer readings, which appears on the status bar. 
8. The SIU Link Rate option has been moved to the 'Configure SIU' dialog 
9. The 'Target Fire Time' option has been removed from the 'Master Start Control' window, as this is now automatically 
determined from the 'Survey Type' selected on the 'Start‐Up' window. 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.02 Build Feb 2012 
 
1. RSS ‐ Renamed the modes of operation and introduced 'Seismic Whilst Drilling' mode, Tz asserted 50 msecs after 
contact closure. 
Display is cleared upon new firing, to avoid old data being shown when misfire occurs. 
Introduced 'Sync Guns From Hydrophone' feature. 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.01 Build Jan 2012 
 
1. RSS ‐ Corrected the hydro ref delay to 2.4s, rather than 3 secs. 
 
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ 
2.00 Build Dec 2011 
 
1. RSS ‐ Now ships with both 32‐bit and 64‐bit USB Driver files, so will now run under 32‐bit or 64‐bit Windows 7 or XP. 
2. RSS ‐ Menubar options split out 
3. RSS ‐ Status Bar now shows more details ‐ MASTER/SLAVE mode, Unit ID, RUN/HALT/HOLD mode, Simulation mode 
4. RSS ‐ RSS can now operate independently of ACQ/GSP, via an option on the Startup dialog 
5. RSS ‐ When in Third‐Party Recorder mode, source selection is made via RSS, when in ACQ/GSP mode all local RSS 
source control options are disabled 
6. RSS ‐ Modem IC has been implemented, in Third‐Party mode, Hydro is now transmitted at 9600bps, otherwise hydro 
is transmitted at 1200 bps(as previously)  
7. RSS ‐ Fire Sync is still implemented at 1200 bps. 
8. RSS ‐ Supports Analogue Hydro output at MASTER, via AHA in Third‐party mode. 
9. RSS ‐ Slave hydro data now displayed at MASTER. 
10. RSS ‐ FC charge status now shown on Status Bar. 
11. RSS ‐ Holding Mode introduced. 
 

                                          24 
 
 

Warnings 
 
Always read the release notes before updating firmware. They contain key information on any bug fixes or known 
limitations etc. 
Note that: 
 
1.  Although upgrading to the latest firmware is generally a good idea (and in some instances certain features will 
not work without), it may not be worth the effort of dissembling & reassembling an otherwise satisfactorily 
operating tool. 
 
2.  In some instances the latest firmware may break compatibility with other tools or older versions of ACQ. This is 
particularly so in the case of mixed tool string systems. 
 
3.  Some firmware versions disable tool auto arm closure and others are support specific hardware builds. If the 
incorrect version is loaded the tool will not work as intended if at all.   
 
4.  X series digitisers store key calibration & usage statistics in flash memory. This can be lost during firmware 
update.   
 
5.  As a general rule if the tool is dissembled to board level for any reason, then firmware upgrade is generally  
advised unless there will be unacceptable consequence such as those indicated above.     
 

USB Drivers for Windows 7 
 
If the USB drivers do not install in Windows 7, you may have to disable ‘Driver Signature Enforcement’. 
A temporary method from the internet is shown below. Read below to see if the issues you are having 
are similar to those being shown for windows 8 and 10. 
** Be aware of the possible issues if your Hard Drive is encrypted – check with your IT dept.** 
 

 
 
                                          25 
 
 

USB drivers for Windows 8, 8.1 and 10 
 
The ACQ install software will load all main programs and a copy of the USB drivers to the directory you choose
during installation.
When a GSP is connected to your PC or Laptop, Windows will realise that a USB device has been connected
and attempt to load the drivers. Generally it will fail to do this although Windows may indicate that the device is
ready.
If you start ACQ at this point and click on Monitor, ACQ will advise that the GSP is Off-line indicating that you
either haven’t got it switched on, it’s not connected or the most likely, (if you have just installed ACQ), the USB
drivers have not been installed.
Calling up “device manager” will give you the indications below.
You can see that the GSP-1 has a yellow triangle next to it indicating that the device has a problem.

Windows 8 and 10 has “Driver Signature enforcement” enabled as standard. If you attempt to install the USB
drivers without temporarily switching this off in Windows, the error below will be displayed. This is because our
drivers (along with many others) are not part of Microsoft’s Signed driver program.

To install the USB drivers, you can follow the procedure below to temporarily disable the “Driver Signature
Enforcement”

                                          26 
 
 

Driver Signature Enforcement on Windows 8 or 10

This process makes changes to the security options of your machine and may upset machines
that are locked by your Administrator. In particular, machines with Bitlocker or other types of
drive encryption installed will request a key or password if you enter the advanced boot options
without suspending them in advance. Always check with your Administrator that you will not
lock yourself out of your machine before attempting this. Always install and test in the workshop
and give yourself plenty of time to sort out problems.

You can use the advanced boot option to disable Driver Signature Enforcement. This isn’t a permanent
configuration change. The next time you restart Windows, it will boot with Driver Signature Enforcement
re-enabled.

**Be aware of the comments above regarding Bitlocker etc. before proceeding**

To do this, follow the path below:-

                                          27 
 
 

Select the “Troubleshoot” tile on the “Choose an option” screen.

Select “Advanced options”.

                                          28 
 
 

Click the “Startup Settings”.

Click the “Restart” button to restart your PC into the Startup Settings screen. Your PC will reboot at this
point.

***At this point, if you have ‘Bitlocker’ or similar Hard drive encryption software installed but not
suspended. Your PC or laptop will restart and ask you for the key*** Be Warned.

                                          29 
 
 

Type “7” or “F7” at the Startup Settings screen to activate the “Disable driver signature enforcement”
option.

Your PC will boot with Driver Signature Enforcement disabled and you’ll be able to install unsigned
drivers. The next time you restart your computer, Driver Signature Enforcement will be re-enabled. You
would need to go through this procedure again to disable it. You’re now free to install drivers that haven’t
been officially signed by Microsoft.

Assuming you have successfully disabled “Driver Signature enforcement”, you can now go back to
device manage and follow the procedure below to install the drivers.

                                          30 
 
 

Double click on the “GSP-1 Geochain System Panel” and follow update driver path.

Click on the “Browse my computer for driver software” to locate the USB drivers.
On 32-bit machines, the default folder for the USB drivers is
‘C:\Program Files\ASL\USB Driver Files\32-bit’
On 64-bit machines, the default folder for the USB drivers is
‘C:\Program Files(x86)\ASL\USB Driver Files \64-bit’

If you installed ACQ into a non-default directory, the USB driver files will be in the directory you created. In my
case I used an “ASL 4.09.9” directory.

If you are unsure whether you have a 32-bit or 64-bit machine, right clicking on the Windows button in Windows
8, 8.1 and 10 and clicking on the “System” button will give you information similar to below.

                                          31 
 
 

On installing the drivers you will most likely get a warning that the drivers have not been authenticated by
Microsoft. This is expected therefore select the “Install this driver software anyway” option.

After installation of the GSP-1, you will notice that a “USB Serial port” will appear under the “other devices”
heading. Double click on this and follow the same procedure to install an Avalon USB driver.

This will complete the process of installing the USB drivers.


You should be able to connect different GSP’s without the need to install the drivers again. Only occasionally
have we had to install drivers more than once. It may happen after a big Windows update for no particular
reason.
 

                                          32 
 

You might also like