Culligan®
Heavy Duty
Commercial
Filter
cafeterias
casinos
corporate campuses
educational facilities
food service
grocery
hotel/ hospitality
institutions
laundry
theme parks
vehicle wash
• Single or Multiple Tank Configurations – Flow rates • Corrosion resistant tanks – Made of low carbon steel
up to 77 gpm(carbon) and 193 gpm(depth). with epoxy interior lining and finish coat painted
exterior.
• Regeneration initiation by choice or combination of
time clock, flow meter or differential pressure switch.
Trust The Water Experts®
Culligan’s CSM™ Commercial Filter
Applications and Benefits
• Food and Beverage–Superior taste and increased • Light Industry Processes—Reduces particulate matter.
cost savings. • Pretreatment—For softeners, RO’s and DI systems.
• Drinking Water–Reduces turbidity and chlorine; • Vehicle Wash—Turbidity reduction.
improves taste and clarity.
• Boilers—Turbidity reduction, minimize sludge
blowdown.
Specifications Table
Water Quality
Superior1 High2 Utility3 Backwash Valve
Flow Rate Pressure Flow Rate Pressure Flow Rate Pressure Flow Rate Size
Model (GPM) Loss (PSI) (GPM) Loss (PSI) (GPM) Loss (PSI) (GPM) (inches)
CSM-201R 9 1 14 2 18 3 20 1.25
Carbon Filters
CSM-242R 13 2 19 3 26 5 30 2
CSM-302R 20 3 30 4 40 6 45 2
CSM-362R 29 2 42 4 57 7 70 2
CSM-422R 39 3 58 6 77 9 95 2
CSM-201D 22 6 33 12 44 19 30 1.25
CSM-202D 22 3 33 5 44 8 30 2
Depth Filters
CSM-242D 32 4 48 8 63 13 45 2
CSM-302D 50 6 74 13 99 20 70 2
CSM-362D 71 9 107 17 142 27 105 2
CSM-422D 97 11 145 22 193 33 150 2
CSM-423D 97 6 145 11 193 16 150 3
1
Superior – Best quality water with lowest pressure loss. Recommended for influent suspended solid loads up to and greater than 300 ppm.
2
High – Very good quality water with increased pressure loss. Recommended for influent suspended solid loads less than 300 ppm.
3
Utility – Satisfactory quality water with greatest pressure loss. Shorter on line time between backwashing. Recommended for influent suspended solid
loads less than 150 ppm.
All pressure drop figures are based on new filter media and a water temperature of 60°F.
Depth filters are capable of 10 micron effluent water quality, whereas all other filter types are capable of 40 micron effluent water quality.
Products manufactured and marketed by Culligan International Company (Culligan) and its affiliates are protected by patents issued or pending in the United States and other
countries. Culligan reserves the right to change the specifications referred to in this literature at any time, without prior notice. , Brunermatic, Hey Culligan Man,
Culligan Man, Culligan Commercial @ Work, www.culligan.com and Culligan Service Network are trademarks of Culligan International Company or its affiliates.
CSM®
Automatic Depth Filters
For Sediment Reduction
Specifications and Operating Data
Service Flow Rates1
Back- Approx.
wash Pipe Media Filter Tank Ship.
Single Tank Superior Quality High Quality Utility Quality Flow2 Size Qty Size Weight
gpm @ psi drop gpm @ psi drop gpm @ psi drop gpm in. lbs in lb
Models m³/hr @ kPa drop m³/hr @ kPa drop m³/hr @ kPa drop m³/hr in. kg mm kg
CSM-201D 22 @ 6 33 @ 12 44 @ 19 30 2 571 20 x 54 1046
5 @ 41.4 7.5 @ 82.7 10 @ 131 6.8 2 259 508 x 1,372 474
CSM-202D 22 @ 3 33 @ 5 44 @ 8 30 2 571 20 x 54 1096
5 @ 20.7 7.5 @ 34.5 10 @ 55.2 6.8 2 259 508 x 1,372 497
CSM-242D 32 @ 4 48 @ 8 63 @ 13 45 2 830 24 x 54 1658
7.3 @ 27.6 10.9 @ 55.2 14.3 @ 89.6 10.2 2 376 610 x 1,372 752
CSM-302D 50 @ 6 74 @ 13 99 @ 20 75 2 1244 30 x 60 2414
11.4 @ 41.4 16.8 @ 89.6 22.5 @ 138 17 2 564 762 x 1,524 1095
CSM-362D 71 @ 9 107 @ 17 142 @ 27 105 2 1765 36 x 60 4030
16.1 @ 62 24.3 @ 117 32.2 @ 186 23.8 2 801 914 x 1,524 1828
CSM-422D 97 @ 11 145 @ 22 193 @ 33 150 2 2488 42 x 60 5008
22 @ 75.8 32.9 @ 152 43.8 @ 228 34.1 2 1129 1,067 x 1,524 2272
CSM-423D 97 @ 6 145 @ 11 193 @ 16 150 3 2488 42 x 60 5008
22 @ 41.4 32.9 @ 75.8 43.8 @ 110 34.1 3 1129 1,067 x 1,524 2272
1
Service flow rates are based on:
Superior (10 gpm/ft² - 24 m³/hr/m²) - Best quality effluent at specified flow. Lowest pressure loss. Recommended for suspended solids loads up to and
greater than 300 ppm.
High (15 gpm/ft² - 37 m³/hr/m²) - Very good quality effluent at specified flow. Increased pressure loss. Recommended for suspended solids loads < 300
ppm.
Utility (20 gpm/ft² - 49 m³/hr/m²) - Satisfactory quality effluent at specified flow. Greatest pressure loss. Recommended for suspended solids loads of <
150 ppm.
2
Backwash flow rates are based on 12-14 gpm/ft² (29-34 m³/hr/m²) using 50° F (10° C) water. A different backwash rate may be required depending upon
water temperature.
NOTE: Operational, maintenance and replacement requirements are essential for this product to perform as advertised. Specifications shown are for
single models. Also available in multiple tank configurations.
Commercial Systems
©2004 Culligan 5/04
1-800-Culligan
www.culligan.com
CSM®
Automatic Cullar® Filters
For Dechlorination and Organic Adsorption
Specifications and Operating Data
Service Flow Rates
Approx.
Taste, Odor & Back-wash Pipe Media Ship.
Single Tank Organic Removal1 Dechlorination2 Flow3 Size Qty Filter Tank Size Weight
gpm @ psi drop gpm @ psi drop gpm in. ft³ in lb
Models m³/hr @ kPa drop m³/hr @ kPa drop m³/hr in. m³ mm kg
CSM-201R 9@1 18 @ 3 20 2 6 20 x 54 690
2 @ 6.9 4.1 @ 20.7 4.5 2 0.17 508 x 1,372 313
CSM-242R 13 @ 2 26 @ 5 30 2 8 24 x 54 1048
3 @ 13.8 5.9 @ 34.5 6.8 2 0.227 610 x 1,372 475
CSM-302R 20 @ 3 40 @ 6 45 2 12 30 x 60 1500
4.5 @ 20.7 9.1 @ 41.4 10.2 2 0.34 762 x 1,524 680
CSM-362R 29 @ 2 57 @ 7 70 2 18 36 x 60 2760
6.6 @ 13.8 12.9 @ 48.3 15.9 2 0.51 914 x 1,524 1252
CSM-422R 39 @ 3 77 @ 9 95 2 24 42 x 60 3180
8.9 @ 20.7 17.5 @ 62 21.6 2 0.68 1,067 x 1,524 1442
1
Service flow rates for taste, odor & organic removal are based on 5 gpm/ft² (12 m³/hr/m²).
2
Service flow rates for dechlorination are based on 10 gpm/ft² (24 m³/hr/m²).
3
Backwash flow rates are based on 10 gpm/ft² (24 m³/hr/m²) using 50° F (10° C) water. A different backwash rate may be required depending upon water
temperature or the type of carbon used.
NOTE: Operational, maintenance and replacement requirements are essential for this product to perform as advertised. Specifications shown are for
single models. Also available in multiple tank configurations.
Commercial Systems
©2004 Culligan 5/04
1-800-Culligan
www.culligan.com
More
M
• Hi-Flo ® 55E
• Hi-Flo ® 50 Multifunctional
Sequences the regeneration process of water
softeners or filtration systems
Filters
• Hi-Flo ® 2E Time, Volume, Aqua-Sensor®*or external device
• Hi-Flo ® 42
• CSM Can be used as a simple timer or more
complex system integrator
• Hi-Flo ® 55E
• Hi-Flo ® 50
V
Versatile
Patented Progressive Flow** feature permits
smaller systems to provide greater flow rates
and treatment capacities
Will adapt to many types of water softeners,
filters or dealkalizers
As many as 6 controls may be linked together,
allowing for simple, future expansion
Operates on 24 VAC
P
Programmable
Time based regeneration schedule can be
interval of days or hours or specific day of
week
®
“Hey Culligan Man!”
, Aqua-Sensor, www.culligan.com and Hey Culligan Man are trademarks of Culligan International Company.
More
TM
REGENERATION CONTROLS
Product Description
The XLF flow sensor package is an input device for the IQS type controller used to measure
treated water flow. Flow data then provides one or all of the following functions:
•repeatedly measure and deliver a specified volume of treated water.
•digital instantaneous flow rate.
•digital instantaneous total treated water usage.
Packages are available for use in treated water pipe sizes from 1 inch through 6 inch. A wide
variety of installation fittings are available to assure compatibility with many commonly used
plumbing materials:
XLF Flow Sensor •Threaded galvanized
•Copper sweat
•PVC; CPVC
•Iron
•Steel
How It Works
The solid state paddlewheel flow sensor
works on a simple, but precise, electro-
mechanical principle. A magnetic rotor
positioned in the flow stream spins past a
solid state switch which in turn pulses a
low voltage DC current proportional to the
Copper/Bronze Tees rate of flow. The rotor design ensures an
accurate, repeatable output throughout the
sensor's entire operating range with
Iron Tee negligible head loss and no cavitation.
▲ Choose the Installation Fitting Pipe Size principally on the MINIMUM flow rate that would
occur REGULARLY in the treated water stream of each water treatment tank.
Temperature/Pressure Relationship Table DO NOT OVERSIZE THE INSTALLATION FITTING!
For Temperature/Pressure Conditions beyond ■ C = flow rate (GPM) @ 1.0 psi head loss; 60°F water temperature.
V
Operating Range of XLF Sensors see OPTIONS
includes worst case requirement of 50 pipe diameters before and 5 pipe diameters
200 ( following the flow sensor location assuring minimum flow turbulence. )
Me
tal
Te
es
Pressure (PSIG)
150 to Pressure Loss @ maximum rated flow: Less diameters required 55 maximum
tal
2 in.
We
/M
eta than 3.5 psig. See formula † adjacent to flow
ld-o
l We sensor location
• includes head loss of required straight length
-let
ld-
o-l dependent on source
sa
to
nS
Operating Range 8
Iron Saddles 2 to 8 in.
TM
Commercial Systems
©2000 Culligan International Co.
1-800-CULLIGAN
www.culligan.com
DCO 992196
Printed in USA 01/00
SL-0064
Moore Part No. 49004
Limited
WARRANTY
Culligan® Hi-Flo® 2 and 2e Series, Hi-Flo® 52 series, Hi-Flo® 42 Series, Hi-Flo® 55e Series,
CSM Series and Hi-Flo® 50 Series
You have just purchased one of the finest water conditioners made. As an expression of our confidence in Culligan
International Company products, this product is warranted to the original end-user, when installed in accordance with
Culligan specifications, against defects in material and workmanship from the date of original installation, as follows:
* The tank must be protected by a vacuum breaker device as described in the unit's operating manual. Damage to the tank
caused by vacuum is not covered by this warranty. The unit must be used in operating conditions that conform to Culligan's
recommended design guidelines. This warranty will not apply if the unit has been modified, repaired or altered by someone not
authorized by Culligan.
If a part described above is found defective within the specified period, you should notify your independently operated Culligan
dealer and arrange a time during normal business hours for the dealer to inspect the water conditioner on your premises. Any
part found defective within the terms of this warranty will be repaired or replaced by the dealer. You pay only freight from our
factory and local dealer charges.
We are not responsible for damage caused by accident, fire, flood, freezing, Act of God, misuse, misapplication, neglect, oxidizing
agents (such as chlorine, ozone, chloramines and other related components), alteration, installation or operation contrary to our
printed instructions, or by the use of accessories or components which do not meet Culligan specifications, is not covered by this
warranty. Refer to the specifications section in the Installation and Operating manual for application parameters.
Our product performance specifications are furnished with each water conditioning unit. TO THE EXTENT PERMITTED BY
LAW, CULLIGAN DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE; TO THE EXTENT REQUIRED BY LAW, ANY SUCH
IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE ONE-YEAR PERIOD SPECIFIED ABOVE FOR THE ENTIRE
CONDITIONER. As a manufacturer, we do not know the characteristics of your water supply or the purpose for which you are
purchasing this product. The quality of water supplies may vary seasonally or over a period of time, and your water usage rate
may vary as well. Water characteristics can also differ considerably if this product is moved to a new location. For these rea-
sons, we assume no liability for the determination of the proper equipment necessary to meet your requirements, and we do
not authorize others to assume such obligations for us. Further, we assume no liability and extend no warranties, express or
implied, for the use of this product with a nonpotable water source or a water source which does not meet the conditions for
use described in the installation and operation manual(s) that accompany the equipment. OUR OBLIGATIONS UNDER THIS
WARRANTY ARE LIMITED TO THE REPAIR OR REPLACEMENT OF THE FAILED PARTS OF THE WATER CONDITIONER,
AND WE ASSUME NO LIABILITY WHATSOEVER FOR DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, SPECIAL,
GENERAL, OR OTHER DAMAGES.
Some states do not allow the exclusion of implied warranties or limitations on how long an implied warranty lasts, so the above
limitation may not apply to you. Similarly, some states do not allow the exclusion of incidental or consequential damages, so
the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have
other rights which vary from state to state. Consult your telephone directory for your local independently operated Culligan
dealer, or write Culligan International Company for warranty and service information.