Liebert 80 Exl 100 1200 KW Brochure English PDF
Liebert 80 Exl 100 1200 KW Brochure English PDF
Liebert 80 Exl 100 1200 KW Brochure English PDF
About Vertiv™
Vertiv brings together hardware, software, analytics and ongoing services to ensure its customers’ vital
applications run continuously, perform optimally and grow with their business needs. Vertiv solves the
most important challenges facing today’s data centers, communication networks and commercial and
industrial facilities with a portfolio of power, cooling and IT infrastructure solutions and services that
extends from the cloud to the edge of the network. Headquartered in Columbus, Ohio, USA, Vertiv
employs around 20,000 people and does business in more than 130 countries. For more information,
and for the latest news and content from Vertiv, visit Vertiv.com.
Vertiv.com
OUR PURPOSE
We believe there is a better way to meet the world’s accelerating demand for data - one driven by passion and innovation.
US AND CANADA LATIN AMERICA EUROPE, MIDDLE EAST AND ASIA PACIFIC
Manuf. and Assembly Locations 7 Manuf. and Assembly Locations 1 AFRICA Manuf. and Assembly Locations 6
Service Centers 120+ Service Centers 20+ Manuf. and Assembly Locations 5 Service Centers 60+
Service Field Engineers 850+ Service Field Engineers 300+ Service Centers 70+ Service Field Engineers 950+
Technical Support/Response 120+ Technical Support/Response 25+ Service Field Engineers 600+ Technical Support/Response 90+
Customer Experience Centers/Labs 4 Customer Experience Centers/Labs 2 Technical Support/Response 95+ Customer Experience Centers/Labs 5
Customer Experience Centers/Labs 6
2
Liebert® EXL S1 from 100 to 1200 kW
Liebert® EXL S1 the New T-free Monolithic UPS Generation Delivering Secure Power and
Maximized Energy Saving
Liebert EXL S1, the new generation of Liebert EXL S1 can operate with both
80-NET UPS, delivers unsurpassed standard VRLA and new Li-ion batteries HIGHLIGHTS
performance to medium-large data thus adapting to all possible
centers as a result of proven track requirements in terms of runtime, life
record, successes, a reliable large expectancy and TCO, and showing y Extraordinary double conversion
installed base and more than 10 years of extreme flexibility. efficiency up to 97%
acquired experience with the 80-NET y Dynamic Online mode for
Furthermore, its higher power density in
technology. highest availability and up to
a minimum footprint optimizes the
The new Liebert S1 is a monolithic availability of IT space and reduces 99% efficiency
product that features a transformer-free related costs. y Intelligent ECO mode efficiency
design with a full IGBT three-level above 99%
Liebert EXL S1, available from 100 to
topology. It provides extraordinary y Intelligent paralleling feature
1200 kW, delivers secure power while
features, including a double conversion optimizes efficiency at partial
providing first class load protection and
efficiency of up to 97%, further improved load
maximum energy saving for mission
to 99% with the dynamic online mode. y Maximized active power at unity
critical applications.
Moreover, the intelligent paralleling power factor
optimizes efficiency at partial load,
y Compact footprint for optimum
achieving superior running cost savings
space utilization
as well as reduced TCO and CO2
emissions. y Backward compatibility with
previous 80-NET generation
y Li-ion battery option to adapt to
all scenarios
y Optional integrated backfeed
protection
>2.5
GW
WORLDWIDE
3
Liebert® EXL S1 from 100 to 1200 kW
100
Liebert EXL S1 also features a full IGBT 40 y Transformer-free design
%K
three-level rectifier allowing for electrical
VA
20 y Full IGBT three-level NPC2
infrastructure cost saving, reducing the
Cosφ 1 topology
size of gensets, circuit protection, 0
25 50 75 100% kW
cabling and transformers. 20 y Excellent input performances:
KVA
Flexibility and Compatibility y - PF > 0.99
40
0%
y - THDi < 3%
10
Liebert EXL S1 can be fully adapted to 60
meet diverse system requirements in y Automatic output power upgrade
80 of up to +10%
terms of power capacity and redundancy
allowing for different system designs, 100 Cosφ 0.4
y Three and four wire electrical
thus ensuring maximum flexibility: compatibility
Lagging
y Output Power Factor up to 1 y Centralized and distributed
y No power derating from 0.4 lagging to Figure 8: Power Factor Output Diagram parallel capabilities
0.7 leading y Seismic compliance
y Optimum space/power ratio
4
Improved Efficiency
Liebert® EXL S1 delivers an outstanding Liebert EXL S1 levels of efficiency and The dynamic online mode ensures Class
double conversion efficiency of up to consequent electricity cost savings can 1 output performance under most
97%, which further increases up to 99% be attribuited to: stringent conditions:
with the dynamic online mode, y Latest generation IGBT y Network fault (voltage variation, high/
consequently reducing operating costs y Adoption of a three-level NPC2 low impedance mains failures)
and energy dissipation (kW) to a topology for both rectifier and inverter
minimum. This significantly minimizes y Load fault (short circuit downstream of
y DC controlled fan speed the UPS)
the consumption of the cooling system, y Intelligent paralleling mode
providing an overall TCO reduction and y Type of load connected (PDU
y Advanced digital technology and fast
rapid payback time. transfer transformer)
Furthermore, through its intelligent ECO The unit is able to discriminate between
The seamless activation of Liebert EXL
mode efficiency and the intelligent various types of interferences and
S1’s functioning modes ensures the rapidly respond, while at the same time
paralleling feature Liebert EXL S1 can highest level of efficiency without
optimize efficiency even at partial load ensuring compatibility with downstream
compromising power quality and equipment such as servers,
achieving additional superior cost availability.
savings. transformers, STS or mechanical loads.
Intelligent Paralleling
33%
Four units at 33% load each = 96%
efficiency.
65%
Liebert EXL S1 Intelligent
Paralleling: two units at 65% load
each = 96.8% efficiency
6
Parallel Configurations
The Liebert® EXL S1 can be connected with up to 8 units in parallel, where single units can be serviced while the remaining units
continue to power the load. A Liebert EXL S1 unit continues to operate even while it’s being upgraded to a parallel system due to
the upgrade occurring via software settings. Furthermore, Liebert EXL S1 is backward compatible with the previous 80-NET
generation, so as to facilitate any legacy system power upgrade. Liebert EXL S1 can support both distributed and centralized
parallel configurations providing maximum energy saving via double conversion and intelligent ECO mode, allowing to operate with
a system efficiency of up to 99%.
Load
7
Liebert® EXL S1 from 100 to 1200 kW
8
Reduced TCO
9
Liebert® EXL S1 from 100 to 1200 kW
Vertiv's service program is designed to ensure that your critical power protection system is
maintained in an optimum state of readiness at all times.
Unit
m e nt
al M anage
T h e rm al
N o rm D ata n
ctio
Colle
rs R
Serve
CE NTE
S Un
it
I CE
UP
C ri t i
cal S ERV
™ 24/7
LIFE
er
gine
m e r E n s it
Y t o i
ILIT C u s - s ite V
R FAC On
YOU
10
11
Liebert® EXL S1 from 100 to 1200 kW
12
Customer Experience Center
Vertiv™ state-of-the-art Customer to 1.2 MVA of capacity. Testing includes Our Customer Experience Center offers
Experience Center located in individual modules, as well as complete three validation experiences:
Castel Guelfo (Bologna - Italy), power systems, with the added y Demo - carried out on new products
enables our customers to possibility of the customer’s switchgear to demonstrate UPS performance
experience first-hand a wide support systems being connected, thus y Standard - validation test showing
guaranteeing smooth, rapid installation UPS standard technical performances
variety of data center
and commissioning of large power in compliance with UPS catalogue and
technologies, supported by systems. IEC 62040-3 standards
constant consultation from R&D Testing is also customized based on the y Customized - session tailored to
and engineering specialists. complexity, size and number of UPS validating customer’s specific technical
components in the configuration. performance needs.
Customers visiting the center will be
able to witness pre-installation
demonstrations, covering the technical
performance, interoperability and
efficiency of Vertiv UPS systems under
real field conditions. These processes
can be experienced from the facility’s
control room, where real-time
performance measurements and
reporting will be available while providing
full visibility of the demonstration area.
The center can host simultaneous tests
at full load of up to 4000 A.
13
Liebert® EXL S1 from 100 to 1200 kW
Technical Specifications
UPS Rating (kVA) 100 120 160 200 300 400 500 600 800 1000 1200
Output active power at 35 °C*(kW) 100 120 160 200 300 400 500 600 800 1000 1200
Output active power at 40 °C (kW) 90 108 144 180 270 360 450 540 720 900 1080
Input
Nominal mains input voltage / voltage range* (V) 400 (200 to 460), 3Ph or 3Ph + N
Nominal bypass input voltage / voltage range* (V) 400 (380/415 selectable), 3Ph or 3Ph + N
Nominal frequency / frequency tolerance (Hz) 50±10%(60 selectable)
Input Power Factor ≥ 0.99
Input current distortion (THDi) (%) ≤3
Integrated Backfeed Protection Device Optional
Output
Nominal output voltage (V) 400 (380/415 selectable), 3Ph or 3Ph + N
Nominal output frequency (Hz) 50 (60 selectable)
Output voltage stability by load variation 0-100% (%)
±1
y static
Complies with IEC/EN 62040-3, Class 1
y dynamic
Output frequency stability
y synchronized with bypass mains (%) ±2 (1, 2, 3, 4, 5 selectable)
y synchronized with internal clock (%) ±0.1
Inverter Overload Capacity* 110% continuous, 125% for 10mins, 150% for 1min
Short circuit current for 200 ms 2.2 In
Load crest factor handled without derating the ups (Ipk/Irms) 3:1
Compatibility with loads Any power factor (leading or lagging) up to 1
Battery
Permissible battery voltage range (V) 396 to 700
Float voltage for VRLA @ 20 °C (V/cell) 2,27
End cell voltage for VRLA (V/cell) 1.65
Float Voltage stability in steady state condition (%) ≤1
DC ripple voltage without battery (%) ≤1
Battery Switch Not included
Bypass
Manual Maintenance Bypass Included 100-500 kW Not included 600-1200 kW
General and System Data
Classification according to IEC/EN 62040-3 VFI-SS-111
Operating Temperature (°C) 0-40
Maximum relative humidity @ 20 °C (non condensing) (%) up to 95
Protection degree with open doors IP 20
Frame colour (RAL scale) 7021
65 67 69 71 76 78
Noise @ 1 metre as per ISO 3746 (dBA ± 2dBA) 64 dBA @partial
65 dBA @partial load 70 dBA @partial load 72 dBA @partial load
load
Parallel configuration up to 8 units in parallel
Access Front and Top (no rear access required)
y VFI efficiency up to 97%
y Dynamic Online (VI) efficiency up to 99%
y VFD efficiency above 99%
Dimension and Weight
Height (mm) 1950
Width (mm) 500 750 1000 1250 1600 2000 2650
Depth (mm) 900
Net Weight (kg) 370 510 725 990 1135 1550 2275
*Conditions apply
14
Data Center Infrastructure for Large Applications
7
3 1 5
UPS
Liebert® Trinergy™ Cube 3.4 MW 2 Remote Diagnostics
y Highest average operating efficiency in the
industry: 99%, with dynamic online mode Vertiv™ LIFE™ Services
y Unprecedented levels of installation Remote Diagnostic and
flexibility 4 Preventive Monitoring
With Vertiv LIFE Services
y Hot scalability up to 3.4 MW.
you will benefit from:
Liebert® EXL S1 1200 kW y Uptime assurance
y Three-level double conversion efficiency of
y First time fix rate
up to 97% plus intelligent paralleling
y Dynamic online mode (VI) efficiency up to y Proactive analysis
99%
y Minimized total cost of
y Intelligent ECO mode (VFD) efficiency
ownership of your
above 99%
equipment
y Enhanced energy density and compact
footprint y Fast incident response
y Parallel system configuration up to 8 units
y Reporting.
with both centralized and distributed
parallel capabilities.
Power Switching
1 AC Power 3 & Controls 5 Racks & Integrated Cabinets
Infrastructure Management
2 & Monitoring 4 Thermal Management 6 Surge Protection
7 DC Power
15
Vertiv.com | Vertiv Infrastructure Limited, George Curl Way, Southampton, SO18 2RY, VAT Number: GB188146827
© 2020 Vertiv Group Corp. All rights reserved. Vertiv™ and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Group Corp. assumes no
responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.
MKA4L0UKEXLS1 Rev.7-01/2020