GA1000 Series Digital Storage Oscilloscope: 2017 Product Catalog Electronic Measurement Instruments

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3
At a glance
Powered by AI
The document discusses specifications and features of GA1000 series digital storage oscilloscopes including bandwidth, sampling rate, memory depth, inputs, triggers, measurements and more.

It has two analog channels, bandwidths up to 200MHz, 1Gsa/s sampling rate, 40K memory depth and supports various trigger types. It also has a 7-inch LCD display and multilingual interface.

It provides 32 automatic measurement functions as well as manual cursor measurements to analyze waveform parameters. It can also perform FFT analysis and has XY mode for phase analysis.

GA1000 Series Digital Storage Oscilloscope

Summary
GA1000 Series is a two channels, 1GSa/s、2GSa/s sampling rate digital storage oscilloscope. It has easy-to-keyboard layout and

enterprises research and development and industrial production.

Main features
● 2 analog channels, Max 200MHz bandwidth, 40Kpts memory depth, 1Gsa/s sampling rate
● Various trigger functions: Edge, Pulse, Video, slope and Alternation
● 32 kinds of automatic measurement and manual cursor tracking measurement functions
● Pass/fall function
● Flexible waveform recording and playback function

● Various kinds of language interface display


11 2017 Product Catalog | Electronic Measurement Instruments


For more information, visit our website: www.gratten.cn

DIGITAL STORAGE OSCILLOSCOPE

Technical Parameters
GA1000CAL/CAM Series
GA1062CAL GA1102CAL GA1202CAL
Model
(GA1072CAM) (GA1112CAM) (GA1202CAM)
Bandwidth 60MHz (70MHz) 100MHz (110MHz) 200MHz

Real-time Sampling Rate 1Gsa/s

Storage Depth 40Kpts; 2Mpts(only CAM Series)

Rise Time <5.8ns <3.5ns <1.7ns

Input Impedance 1MΩ±2%∥16±3pF 1MΩ±2%∥20±3pF 50Ω 5vrms

Time Base 5ns-50s/div (step-by-step 1-2-5) 5ns-50s/div (step-by-step 1-2-5) 2ns-50s/div (step-by-step 1-2-5)

Vertical Sensitivity 2mV-10V/div (step-by-step 1-2-5)(CAL);2mV-5V/div (step-by-step 1-2-5)(CAM)

GA1000CEL/CEM Series
GA1112CEL GA1202CEL GA1302CEL
Model
(GA1112CEM) (GA1202CEM) (GA1302CEM)
Bandwidth 110MHz 200MHz 300MHz

Real-time Sampling Rate 2Gsa/s

Storage Depth 40K (only CEL Series)、2M (only CEM Series)

Rise Time <3.5ns <1.7ns

Input Impedance 1MΩ±2%∥16±3pF 1MΩ±2%∥20±3pF 50Ω 5vrms

Time Base 2ns-50s/div (step-by-step 1-2-5) 1ns-50s/div (step-by-step 1-2-5) 1ns-50s/div (step-by-step 1-2-5)

Vertical Sensitivity 2mV-5V/div (step-by-step 1-2-5)

GA1000DAL/DEL Series
Model GA1072DAL GA1102DAL GA1202DAL/DEL GA1302DEL
Bandwidth 70MHz 110MHz 200MHz 300MHz

Real-time Sampling Rate 1Gsa/s (only DAL Series); 2Gsa/s (only DEL Series)

Storage Depth 40Kpts

Rise Time <5.8ns <3.5ns <1.7ns

Input Impedance 1MΩ±2%∥16±3pF 1MΩ±2%∥20±3pF 50Ω 5vrms

2ns/div-50s/div (1-2-5)(Only DAL Series)


Time Base 2ns-50s/div
1ns/div-50s/div (1-2-5)(Only DEL Series)

Vertical Sensitivity 2mV-10V/div (step-by-step 1-2-5) 2mV-5V/div (step-by-step 1-2-5)

Vertical Resolution 8 bits

Channels 2

Trigger Signal Source CH1, CH2, EXT, EXT/5, AC LINE

Trigger mode Edge﹑Pulse﹑Video﹑Slope﹑Alternate

Arithmetical operation +, -, ×, ÷ , FFT

Digital Filtering High pass、Low pass、Band elimination、Band pass

Max Input Voltage 400V (DC+AC peak, 1MΩinput impedance)

Internal Storage 2 groups of reference waveform,20 groups of setups,16 groups of waveform

External Storage

Display Language

Port USB Host, USB Device, RS-232, Pass/Fail out

TFT 7-inch (178mm)LCD


Display
800 (horizontal)pixels × 480 (vertical)pixels

Power Voltage 100~240V (AC), 45~440Hz, 30VA Max

2017 Product Catalog | Electronic Measurement Instruments 12


Features

Small signal capture Advanced trigger settings Automatic measurement function


Better noise function with excellent performance, Various triggering options are available to capture any The full featured acquisition model and 32 automatic
accurately captures even the faint signal giving you the signal of interest with Edge, slope, video, pulse, width, measurement functions help user to measure captured
waveform parameters more accurately. Auto measure
observation, analysis signal types, saving the cost of function can eliminate user error consumedly, and users
testing. will measure parameters what they need faster and more
accurately using it.

XY mode display Reference waveform storage FFT split–screen display


Use XY format to analyze phase. In this mode the data is Two reference waveforms can be stored into the internal FFT waveform and its Channel waveform can display on
displayed as dots. memory and can be opened simultaneously, thus showing split screen at the same time. In split display mode, the
the sample and reference waveforms in comparison. screen is divided is divided into two parts and each part is
divided eight divides in vertical direction. User can
observe and analyze two waveforms simultaneously
making it more clearer and convenient.

Waveform recording/playback Pass/Fail


Wavefomr recorder can record input waveform form CH1 Users may use the Pass/Fail function to carry on the
and CH2, with maximum recod length of 1000 frames. This product test. Through a series of setups, the oscilloscope
record behaviour can also be activated by the pass/fail test can output the test result automatically which enhanced
output which makes this function specially useful to
capture abnormal signals in long term without keeping an
eye watching it.

User-friendly Design

A waveform adjustable brightness Signal persistence view PC software


Waveform brightness adjustable to clearly observe the Display the signal path of the frequency. When acquisitions Easy to use PC control software is the easiest and convenient
waveforms. The screen displays parameter value and the are stopped, the screen may show data from many way to remotely capture and analyzer the waveform data. This
waveforms are visible clearly and form a broad range of acquisitions or the last acquisition. The past acquisition can software can be compatible RS-232 and USB Device to
viewing angle. be displayed based on 4 different time based options of communicate between the computer and the oscilloscope useful
for remote operation. It can automatically refresh realtime
waveform data, provide waveforms sampling data, read storage
and printing functions.
13 2017 Product Catalog | Electronic Measurement Instruments