GRAUER & WEIL (INDIA) LTD.

(Paints Division)

PENTADUR EPOXY PHENALKAMINE ZINC PHOSPHATE PRIMER.

DESCRIPTION : PENTADUR EPOXY PHENALKAMINE ZINC PHOSPHATE


PRIMER is a two-component phenalkamine cured Epoxy Primer
containing Zinc Phosphate as corrosion inhibiting pigment. It
cures to a tough and highly rust preventive coat. It can cure at
low temperature
.
TYPICAL USE :As a primer in PENTADUR systems on steel and other metal
surfaces in moderate to severe corrosive marine and industrial
environment.

PRODUCT DATA:
MIXING RATIO : Base: 5 parts by volume
Curing Agent : 1 part by volume

POT LIFE : 6 – 8 hours at 300 C

APPLICATION : Airless Spray, Air Spray, Brush

NOZZLE ORIFICE : 0.021”

NOZZLE PRESSURE : 2540 psi

VOLUME SOLIDS : 65 %

RECOMMENDED DFT : 75 microns

CORRESPONDING WFT : 125 microns

THEORETICAL SPREADING
RATE AT ABOVE DFT : 8.66 M2 / Ltr.

SURFACE DRY : 2 hrs. at 300 C

HARD DRY : 16 Hrs.

FULLY CURED : 1 week at 300 C

COLOUR : Red Oxide, Grey


FINISH : Matt
OVERCOAT INTERVAL : Min. 16 hrs. Max. 30 days

E-33. ..2..
::2::

PENTADUR EPOXY PHENALKAMINE ZINC PHOSPHAT PRIMER.


FLASH POINT : Above 260 C

THINNER : 145

SHELF LIFE : 12 months

SURFACE PREPARATION :

NEW STEEL : Abrasive blasting to Sa 2½. If a shop primer is used, all


damages to shop primer and contamination from storage
and fabrication should be thoroughly cleaned prior to final
painting. For repair and touch up use PENTADUR
EPOXY PHENALKAMINE ZINC PHOSPHATE PRIMER..

ON OTHER METAL AND LIGHT ALLOYS: Thorough


degreasing and light abrasive sweeping to remove all
contamination.

MAINTENANCE : Remove oil and grease with a detergent solution and


high pressure fresh water hosing. Galvanized steel may
require light blasting with a fine abrasive depending on the
condition of the surface and the degree of contamination.

HEALTH & SAFETY : As a general rule, avoid inhalation of solvent vapours or


paint mist and contact of paint with skin and eyes. Provide
forced ventilation when working with solvent borne coating
in confined spaces or stagnant air. Also provide
respiratory, skin and eye protection. Also follow local and
national safety regulations.