Nothing Special   »   [go: up one dir, main page]

IRIS1 NV (New) Spec Data Sheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

IRIS1 NV(new) Spec Data Sheet

BOMCO
No. Parameter 630kg 800kg 1000kg Range Unit Remark
60 90
105 60 90 105 60 90 105
F00 Adjust starting acceleration 550 550
550 550 550 550 550 550 550 200-1500 mm/s2
F01 Adjust braking deceleration 550 550
550 550 550 550 550 550 550 200-1500 mm/s2
F02 S Jerk T0(S curve jerk start at start 1300 1300
1300 1300 1300 1300 1300 1300 1300 300-3000 ms
F03 S Jerk T1(S curve jerk at end of 1100 1100
1100 1100 1100 1100 1100 1100 1100 300-2000 ms
F04 S Jerk T2(S curve jerk at start of 1100 1100
1100 1100 1100 1100 1100 1100 1100 300-2000 ms
F05 S Jerk T3(S curve jerk at end of 1300 1300
1300 1300 1300 1300 1300 1300 1300 30-3000 ms
F06 Rated speed Refer to “Different Parameter” 200-6000 mm/s
F08 Encoder Pulses 8192 8192 8192 8192 8192 8192 8192 8192 8192 100-10000 ppr 2048
F09 Locked home landing 1 1 1 1 1 1 1 1 1 1-64
F10 Floor offset 0 0 0 0 0 0 0 0 0 0-64
F11 No. of Floor Based on jobsite 2-64
F12 Inspection Speed 250 250 250 250 250 250 250 250 250 0-500 mm/s
F13 Relevelling Speed 20 20 20 20 20 20 20 20 20 10-150 mm/s
F14 Door-closing delay for calls 30 30 30 30 30 30 30 30 30 0-300 0.1s
F15 Door-closing delay for registrations 30 30 30 30 30 30 30 30 30 0-300 0.1s
F16 Brake delay 2 2 2 2 2 2 2 2 2 0-20 0.1s
F17 Operation removal delay 6 6 6 6 6 6 6 6 6 2-30 0.1s
F18 Fire home 1 1 1 1 1 1 1 1 1 0-64
F19 Second fire home 1 1 1 1 1 1 1 1 1 0-64
F20 Homing Delay 0 0 0 0 0 0 0 0 0 0-65535 s
F21 Level adjust distance(Tolerance in 6 6 6 6 6 6 6 6 6 0-40 mm
F22 1st main landing by duplex control 1 1 1 1 1 1 1 1 1 1-64
F23 Group mode 3 3 3 3 3 3 3 3 3 0-4
F25 Input Type 1(X0-X15 Input N/O,N/C 32819 0-65535
F26 Input Type 2(X16-X31 Input N/O,N/C 2 0-65535
F27 Input type 3(N.O./ N.C. setting for 0 0 0 0 0 0 0 0 0 0-65535
F28 Input type 4(N.O./ N.C. setting for Refer to “Different Parameter” 0-65535
F29 Service floor setting 1(whether stop 65535 65535 65535 65535 65535 65535 65535 65535 65535 0-65535
on Fl. 1-16)
F30 Service floor setting 2(whether stop 65535 65535 65535 65535 65535 65535 65535 65535 65535 0-65535
on Fl. 17-32)
F31 Service floor setting 3(whether stop 65535 65535 65535 65535 65535 65535 65535 65535 65535 0-65535
on Fl. 33-48)
F190 Service floor setting 4(whether stop 65535 65535 65535 65535 65535 65535 65535 65535 65535 0-65535
on Fl. 49-64)
F32 Standby 0~7
F33 Interval between trips in automatic 5 5 5 5 5 5 5 5 5 0-60
F34 Number of trips in automatic running 0 0 0 0 0 0 0 0 0 0-65535
F35 firefeighter mode 0 0 0 0 0 0 0 0 0 0-65535
F36 Brake switch detection mode 0 0 0 0 0 0 0 0 0 0-65535
F40 Load Device Learn 48 48 48 48 48 48 48 48 48 0-100
F41 Load Device Learn 0 0 0 0 0 0 0 0 0 0-65535
F43 Bit function param- -eter 19 19 19 19 19 19 19 19 19 0-255
F44 Monitor Address 255 255 255 255 255 255 255 255 255 0-255
F48 Zero Load Value 0 0 0 0 0 0 0 0 0 0-1024
F49 Full Load Value 1024 1024 1024 1024 1024 1024 1024 1024 1024 0-1024
F50 Front door-opening allowed 1 for Fl.1- 65535 65535 65535 65535 65535 65535 65535 65535 65535 0-65535
16
F51 Front door-opening allowed 2 for Fl.17- 65535 65535 65535 65535 65535 65535 65535 65535 65535 0-65535
F52 Front door-opening allowed 3 for Fl.33- 65535 65535 65535 65535 65535 65535 65535 65535 65535 0-65535
F191 Front door-opening allowed 4 for Fl.49- 65535 65535 65535 65535 65535 65535 65535 65535 65535 0-65535
F53 Rear door-opening allowed 1 for Fl.1- 0 0 0 0 0 0 0 0 0 0-65535
16
F54 Rear door-opening allowed 2 for Fl.17- 0 0 0 0 0 0 0 0 0 0-65535
32
F55 Rear door-opening allowed 3 for Fl.33- 0 0 0 0 0 0 0 0 0 0-65535
48
F192 Rear door-opening allowed 4 for Fl.49- 0 0 0 0 0 0 0 0 0 0-65535
64
F56 Leveling adjustment up(50 for 50 50 50 50 50 50 50 50 50 0-65535 mm
baseline)
F57 Leveling adjustment down(50 for 50 50 50 50 50 50 50 50 50 0-65535 mm
baseline)
F58 Speed curve delay at start 5 5 5 5 5 5 5 5 5 0-250 0.1s
F59 Zero-speed band brake delay 0 0 0 0 0 0 0 0 0 0-65535 0.01s
F60 KMC testing mode ( the 2nd contactor 3~3
3 3 3 3 3 3 3 3 3
of the main circuit)
F61 Distance for triggering arrival gong 1200 1200 1200 1200 1200 1200 1200 1200 1200 0-65535 mm
F62 Time limit for anti-slippage operation 32 32 32 32 32 32 32 32 32 20-45 s
F65 Base block mode 0 0 0 0 0 0 0 0 0 0-1
F66 ALP mode 0 0 0 0 0 0 0 0 0 0-1
F67 Extension Board Enable 0 0 0 0 0 0 0 0 0 0-1
F68 Limit switch enable 0 0 0 0 0 0 0 0 0 0-1
F70 Up gain(light load) 100 100 100 100 100 100 100 100 100 0-300 %
F71 Down gain(light load) 100 100 100 100 100 100 100 100 100 0-300 %
F72 Up gain(heavy load) 100 100 100 100 100 100 100 100 100 0-300 %
F73 Down gain(heavy load) 100 100 100 100 100 100 100 100 100 0-300 %
F74 Height gain(light load) 512 512 512 512 512 512 512 512 512 0-1024
F75 Height gain(heavy load) 512 512 512 512 512 512 512 512 512 0-1024
F115 Open door overtime 15 15 15 15 15 15 15 15 15 40632 (s)
BOMCO
No. Parameter 630kg 800kg 1000kg Range Unit Remark
60 90
105 60 105 90
60 105 90
F116 Close door overtime 15 15
15 15 15 15
15 15 15 40632 (s)
F117 Holding time before forced door closing 60 60
60 60 60 60
60 60 60 0-65535 s
F118 Holding time for the handicapped 30 30
30 30 30 30
30 30 30 0-65535 s
F120 Number of registrations for anti- 0 00 0 0 0 0 0 0 0-65535
nuisance
F121 Forced door-closing enable 0 0 0 0 0 0 0 0 0 0-1
F122 Release direction delay during 3 3 3 3 3 3 3 3 3 0-65535 0.1s
F123 Landing call classification 0 0 0 0 0 0 0 0 0 0-65535
F124 Failure time of light curtain 60 60 60 60 60 60 60 60 60 0-1300 s
F125 rear door light curtain disable time 60 60 60 60 60 60 60 60 60 0-1300 s
F128 Separate door control 0 0 0 0 0 0 0 0 0 0-65535
F129 Relevelling with door open and/or pre- 0 0 0 0 0 0 0 0 0 0-65535
door-opening Enable.
F130 Holding door-opening/closing torque 0 0 0 0 0 0 0 0 0 0-65535
F131- Parameter for the functions related to 0 0 0 0 0 0 0 0 0
133 time
F137 Service floor setting 1(whether stop 65535 65535 65535 65535 65535 65535 65535 65535 65535 0-65535
on Fl. 1-16)by NS-SW
F138 Service floor setting 2(whether stop 65535 65535 65535 65535 65535 65535 65535 65535 65535 0-65535
on Fl. 17-32)by NS-SW
F139 Service floor setting 3(whether stop 65535 65535 65535 65535 65535 65535 65535 65535 65535 0-65535
on Fl. 33-48)by NS-SW
F199 Service floor setting 4(whether stop 65535 65535 65535 65535 65535 65535 65535 65535 65535 0-65535
on Fl. 49-64)by NS-SW
F140 Weighing value of full load 80 80 80 80 80 80 80 80 80 0-65535 %
F141 KMY release delay 100 100 100 100 100 100 100 100 100 100-65535 5ms
F142 Anti-crime floor 2 2 2 2 2 2 2 2 2 1-64
F145 Bus voltage gain 100 100 100 100 100 100 100 100 100 100-120 %
F146 Allowed gap between actually position 180 180 180 180 180 180 180 180 180 180-65535 mm
F147 Selection of the protection method for 0 0 0 0 0 0 0 0 0 0-65535
F148 Door open time of the base floor 30 30 30 30 30 30 30 30 30 0-12000 0.1s
F150 Set SM.04V12/A, SM.04HS/E or 0-4
0 0 0 0 0 0 0 0 0
SM.04VS/T output of LED
F151 Set SM.04H12/B output of LED 0 0 0 0 0 0 0 0 0 0-4
F152 Delay for car-lighting before 5 5 5 5 5 5 5 5 5 0-65535 60s
automatically switching off car-lighting
and fan
F153 Hall door lock check enable 1 1 1 1 1 1 1 1 1 0-65535
F154 Voice information selection 1 0 0 0 0 0 0 0 0 0 0-65535
F155 Voice information selection 2 34 34 34 34 34 34 34 34 34 0-65535
F156 Door lock and safe loop relay check 3 3 3 3 3 3 3 3 3 0-65535
F160 Clearing error registrations manually 1 1 1 1 1 1 1 1 1 0-65535
F161 Time-sharing door blocking function 0 0 0 0 0 0 0 0 0 0-65535
F163 Run in emergency power 0 0 0 0 0 0 0 0 0 0-65535
F164 Load-weighing signal 9 9 9 9 9 9 9 9 9 0-65535
F165 0-65535
Door open selection in testing traveling 0 0 0 0 0 0 0 0 0
F168 Elevator numbering for IC card service 0 0 0 0 0 0 0 0 0 0-65535
F169 Setting landings for up/down calls by IC 0 0 0 0 0 0 0 0 0 0-65535
card
F170 With IC control in car, 1-16 Fl. for 0 0 0 0 0 0 0 0 0 0-65535
selection of identification by IC card
F171 With IC control in car, 17-32 Fl. for 0 0 0 0 0 0 0 0 0 0-65535
selection of identification by IC card
F172 With IC control in car, 33-48 Fl. for 0 0 0 0 0 0 0 0 0 0-65535
selection of identification by IC card
F175 Creeping speed at start 6 6 6 6 6 6 6 6 6 0-100 mm/s
F180 Velocity increment 1000 1000 1000 1000 1000 1000 1000 1000 1000 0-65535 ‰
F181 Elevator numbering in duplex control 0 0 0 0 0 0 0 0 0 0-65535
F182 Steps of speed reduction switches 1 1 1 1 1 1 1 1 1 0-65535
F183 Speed at self-tuning 800 800 800 800 800 800 800 800 800 0-65535 mm/s
F186 Creeping speed at start 50 50 50 50 50 50 50 50 50 0-65535 10ms
F187 Monitoring Item 14 14 14 14 14 14 14 14 14 0-65535
F193 Standby 0 0 0 0 0 0 0 0 0 0-1000 0,001
F194 Standby 1000 1000 1000 1000 1000 1000 1000 1000 1000 0-1000 0,001
F195 Standby 0 0 0 0 0 0 0 0 0 0-1000 0,001
F196 2nd main landing by duplex control 0 0 0 0 0 0 0 0 0 0-64
F200 DSP software revision number Read only
F201 Drive mode of inverter 3 3 3 3 3 3 3 3 3
F202 Motor type 1 1 1 1 1 1 1 1 1 0-65535
F203 40-16000 0.01K
Rated power of motor Refer to “Different Parameter”
W
F204 Rated current of motor Refer to “Different Parameter” 0-65535 0.1A
F205 Rated frequency of motor Refer to “Different Parameter” 0-12000 0.01HZ
F206 RPM of motor Refer to “Different Parameter” 0-65535 rpm
F207 Rated voltage of motor 380 380 380 380 380 380 380 380 380 0-65535 V
F208 Motor poles Refer to “Different Parameter” 0-65535
F209 0-65535 0.01HZ
Motor rated slip frequency 140 140 140 140 140 140 140 140 140
BOMCO
No. Parameter 630kg 800kg 1000kg Range Unit Remark
60 90 105 60 90 105 60 90 105
F210 Encoder type 0 0 0 0 0 0 0 0 0 0-65535
F211 Encoder pulses 8192 8192 8192 8192 8192 8192 8192 8192 8192 0-65535 PPr
F212 Zero speed PID P0 13000 13000 13000 13000 13000 13000 13000 13000 13000 0-65535 0,01
F213 Zero speed PID I0 8000 8000 8000 8000 8000 8000 8000 8000 8000 0-65535 0,01
F214 Zero speed PID D0 50 50 50 50 50 50 50 50 50 0-65535 0,01
F215 Low speed PID P0 7000 7000 7000 7000 7000 7000 7000 7000 7000 0-65535 0,01
F216 Low speed PID I0 3000 3000 3000 3000 3000 3000 3000 3000 3000 0-65535 0,01
F217 Low speed PID D0 50 50 50 50 50 50 50 50 50 0-65535 0,01
F218 Middle speed PID P0 12000 12000 12000 12000 12000 12000 12000 12000 12000 0-65535 0,01
F219 Middle speed PID I0 2500 2500 2500 2500 2500 2500 2500 2500 2500 0-65535 0,01
F220 Middle speed PID D0 20 20 20 20 20 20 20 20 20 0-65535 0,01
F221 High speed PID P0 14000 14000 14000 14000 14000 14000 14000 14000 14000 0-65535 0,01
F222 High speed PID I0 500 500 500 500 500 500 500 500 500 0-65535 0,01
F223 High speed PID D0 10 10 10 10 10 10 10 10 10 0-65535 0,01
F224 Low speed switchover frequency 10 10 10 10 10 10 10 10 10 0-1000 0,10%
F225 High speed switchover frequency 500 500 500 500 500 500 500 500 500 0-1000 0,10%
F226 Zero speed servo time 5 5 5 5 5 5 5 5 5 0-300 0.1s
F227 Brake open time 25 25 25 25 25 25 25 25 25 0-3000 0.01s
F228 Current strike time 0 0 0 0 0 0 0 0 0 0-1000 0.01s
F229 Torque compensation direction 0 0 0 0 0 0 0 0 0 0-1
F230 Torque compensation gain 1000 1000 1000 1000 1000 1000 1000 1000 1000 0-2000 0,10%
F231 Torque compensation bias 0 0 0 0 0 0 0 0 0 0-1000
F232 Filtering time for feedback signal of 0-30 ms
0 0 0 0 0 0 0 0 0
encoder
F233 Feedback direction of encoder 1 1 1 1 1 1 1 1 1 0-1
F234 Motor phase sequence 1 1 1 1 1 1 1 1 1 0-1
F235 Motor no-load current coefficient 3200 3200 3200 3200 3200 3200 3200 3200 3200 0-6000 0,01%
F236 1100 - HZ
PWM carrier frequency 6000 6000 6000 6000 6000 6000 6000 6000 6000
11000
F237 PWM carrier width 0 0 0 0 0 0 0 0 0 0-1000 HZ
F238 Adjuster mode 1 1 1 1 1 1 1 1 1 0-3
F239 Output torque limit 175 175 175 175 175 175 175 175 175 0-200 %
F240 Input voltage of transducer 380 380 380 380 380 380 380 380 380 0-460 V
F241 Read Read Read Read Read Read Read Read Read
Rated power of inverter
only only only only only only only only only
F242 0 0 0 0 0 0 0 0 0 0-3600 0.1deg
Phase angle of encoder
ree
F243 Zero position correction of encoder 0 0 0 0 0 0 0 0 0 0-2