700-45 Spec Sheet - Rev 3
700-45 Spec Sheet - Rev 3
700-45 Spec Sheet - Rev 3
FLOW ILLUSTRATION
solutions for preset VISCOSITY RANGE: will accurately measure liquids up to 225 SSU (44 CPS)
delivery, flow rate LINEARITY:
control, blending and 5:1 Turndown - capable of ± 0.100% of maximum nominal flow rate
10:1 Turndown - capable of ± 0.125% of maximum nominal flow rate
custody transfer of 15:1 Turndown - capable of ± 0.150% of maximum nominal flow rate
vehicle or wholesale REPEATABILITY: capable of 0.02% over the entire range of flow
measurement applica-
Data provided from test conditions where all system variables were constant. The results are based on the
tions. custody transfer 700 series flow meters (SPA & SPD) and Veeder Root mechanical registration, using 32 SSU
testing fluid..
REGULATORY: NIST, OIML, Canada, SABS, NMI, USA military and other
international weights and measures approved.
OPERATING SPECIFICATIONS
INDUSTRIES SERVED DESIGN TYPE: Positive Displacement Rotary Abutment
Alternative Fuels
Aviation Fuels FLOW CAPACITY: 40 GPM to 600 GPM
151 LPM to 2271 LPM
Petrochemicals
Refined Fuels VISCOSITY: Up to 225 SSU (44 CPS)
Solvents
PRESSURE RATING: 150 PSI (10.5 BAR)
Optional: 275 PSI (19 BAR)
MATERIALS OF CONSTRUCTION
Meter Bearing Bearing Timing Internal
Housing Rotors Journals Seals
Type Plates Sleeves Gears Hardware
REGISTRATION OPTIONS
COUNTER REGISTER ELECTRONIC METER REGISTER MICROSWITCH
Liquid measurement volume indica- Digital liquid measurement volume in- Mechanical signal from the Veeder
tion, using a 5 digit large numeral dication that offers multiple functions to Root preset counter converted into
reset display and an 8 digit non-reset enhance the flow meter's accuracy and an electrical or pneumatic signal to
totalizer. Electronic or mechanical accountability. Most electronic registra- provide control of remotely located
meter counter register is available. tion are available with rate of flow indi- valve, pump, and other system re-
U.S. or Imperial Gallons, Liters, cation, pulse output, valve control, lated equipment.
Dekaliter, Barrels, pounds, etc. RS232 and RS485 communication, cur-
rency and temperature compensation. COUNTER EXTENSION
COUNTER PRESET Raises the elevation of the counter
Select predetermined volume for pre- PULSE TRANSMITTER registration for easy visibility or to
cise batch control, utilizing preset The electronic pulse signal output con- protect from high temperatures.
control valve. Mechanical or elec- verts the register counter volume per Counter Extension is required for
tronic preset counters or batch con- unit value into a electrical pulse stream. temperatures more than 180°F
trollers are available. The electronic pulse stream can be (82°C).
transmitted to other electronic control-
TICKET PRINTER lers for rate of flow, volume indication, RATE OF FLOW INDICATOR
Provides an imprinted ticket record additive injection or data acquisition. Mechanical or digital indicator
of each delivery transaction. Accu- displays the volume at which the
mulative or Zero-Start, Face down or TEMPERATURE COMPENSATION liquid is flowing through the flow
Face Up mechanical ticket printers Automatically corrects changes in vol- meter.
available. Electronic slip or roll ume caused by liquid temperature varia-
printers available for use with vari- tions, during metered delivery. Normal- SWIVEL
ous electronic registration. ly corrects net volume or mass to 60°F Allows mechanical registration to
(15°C) based on the product’s be rotated 360°. Designed for the
coefficient of expansion, API or specific Veeder Root counter register and
gravity. ticket printer only.
METER ACCESSORIES
AIR ELIMINATOR MECHANICAL PRESET VALVE
A float and reed valve operated design senses A normally closed, hydraulically balanced
and removes free air or vapor before it can piston control valve allows for auto-batch
enter the flow meter. Required for custody preset deliveries. The right angle, two–stage
transfer applications to ensure the most pre- control valve is mechanically linked to Veed-
cise measurement. er Root Preset Counter.
ASSEMBLY COMBINATIONS
GROUP COMBINATIONS
2 Meter & Register
3 Meter, Register & Ticket Printer
4 Meter, Register, Air Eliminator & Strainer
4S Meter, Register, Electronic Eliminator & Strainer
5 Meter, Register & Strainer
6 Meter, Register, Ticket Printer, Air Eliminator & Strainer
7 Meter, Register, Printer, & Strainer
GROUP 2 GROUP 4
8 Meter, Register, Preset & Valve
9 Meter, Register, Ticket Printer, Preset & Valve
10 Meter, Register, Preset, Valve, Air Eliminator & Strainer
10S Meter, Register, Preset, Valve, Electronic Air Eliminator & Strainer
11 Meter, Register, Ticket Printer, Preset, Valve, Air Eliminator & Strainer
12 Meter, Register, Preset, Valve & Strainer
13 Meter, Register, Ticket Printer, Preset, Valve & Strainer
GROUP 8 GROUP 10
METER ORIENTATION
A Meter Assembly with Veeder Root Registration E Meter Assembly with TCS3000; 75 Degree Mount
B Meter assembly less Veeder Root Registration D Meter Assembly with TCS3000; 90 Degree Mount
C Meter Assembly for use with Electronic Registration F Meter Assembly (Meter D) with Remote TCS3000
(less calibration adjuster)
D Meter Assembly with direct drive pulse transmitter
0 0 0 5 0 9 7 0
Liters
9 6 1 0 0
S
S
T
E
T
9 6 1 0 0 O
P
9 6 1 0 0
110 12 10 12 32 32 134 25 Consult 17
SPA
(49.9) (5.4) (4.5) (5.4) (14.5) (14.5) (60.8) (11.3)
S
E
T
9 6 1 Factory
0 0
S
T
O
P
(7.7)
275 12 10 12 74 74 144 53 Consult
SPD N/A
(124.7)) (5.4) (4.5) (5.4) (33.6) (33.6) (65.3) (24.0) Factory
WARRANTY
Total Control Systems 700 rotary meters and accessory components sold to the original purchaser for a period of
TWELVE (12) months from installation or EIGHTEEN (18) months from the date of shipment, to be free, under normal
use and service, from defects in material and workmanship. If a warranty dispute occurs the DISTIBUTOR may be re-
quired to provide proof of date of sale. Defects occurring within the stated warranty period, will be repaired or replaced,
at TCS’s option; provided that part or parts are returned to TCS transportation charges prepaid, and TCS’s examination
discloses the parts or workmanship to have been defective upon delivery to the purchaser. All repaired or warranted me-
ters will be shipped Ex-works Fort Wayne, Indiana. Total Control Systems shall not be liable for consequential damages,
whether or not arising out of warranty, negligence or otherwise.
NOTE: The above warranty applies only to Total Control Systems, Fort Wayne, Indiana manufactured products. Private
label and OEM engineered products are specifically excluded from the above warranty. Consult factory for non-TCS
manufacturer’s warranty.