Extending The: Power of MR
Extending The: Power of MR
Extending The: Power of MR
1 Accessible is defined as features that are expected to contribute to speed, consistency, user or patient friendliness
2 Definitive is defined as features that are expected to deliver alternative contrasts, functional or quantitative images
2 3
• ScanTools Pro 6
• A la Carte 84
• System compatibility 95
4 5
ScanTools Pro 3D BrainVIEW
View your 3D TSE imaging
Diffusion
Non-invasive assessment
DWI TSE
Diffusion imaging with
Perfusion
T2* perfusion imaging in short
data in any plane of tissue structure reduced distortion scan times
Scantools Pro provides the following generic workflow features for all clinical anatomies:
• ExamCards, for automated scanning and processing of patient studies. Examcards can be edited during scanning.
The Split Exam option provides you the ability to separate imaging series acquired during a single scan session into
multiple scan instances. This allows for correct association of imaging series to ordered/scheduled examinations to
facilitate proper reporting, data handling and billing activities.
3D DRIVE mFFE 3D MSK VIEW DWIBS
• SENSE parallel imaging methods for fast scan times, high resolution or to reduce susceptibility artifacts. Short scan time, brighter fluid Optimal visualization View your 3D TSE imaging Easily visualize lesions
data in any plane throughout the body
of the spinal cord
• CLEAR for signal uniformity correction based on coil-sensitivity and on patient loading.
• PicturePlus to improve appearance of images through edge enhancement and smoothing. Provides full control over
all enhancement parameters, which can be applied automatically post-acquisition or as a post-processing option.
In addition, ScanTools Pro contains fast, high resolution imaging methods for the assessment of morphology of all
anatomical areas including brain and spine, MSK, body and breast, cardiac, and various blood vessels with or without
contrast agents. Specific features per clinical area are listed below.
Real-Time Cardiac Cardiac MS/QF
Benefit from intuitive planning Elevate your cardiac imaging
for cardiac studies to clinical routine level
6 7
dS Performance Suite Plus AutoVoice Page 10
Guiding your patients through the
ComforTone
Reduce acoustic noise and
Page 11 ScanWise Implant
A key to confidence with
Page 12 SmartExam Brain Page 13
Standardized exams forconsistent
MR examination enhance MR experience MR Conditional implants
MRI results
8 9
AutoVoice ComforTone
Guiding your patients Reduce acoustic
through the MR noise and enhance
examination MR patient experience
AutoVoice is a fully integrated and automated solution that guides Additional information: Leveraging our years of experience in acoustic noise reduction Additional information:
your patients through the MR examination by indicating scan duration, technologies, our unique ComforTone solution achieves up to 80%
announcing table movements and providing breathhold guidance, helping acoustic noise reduction1 with similar image quality and contrast
you enhance patient comfort. Automated breathhold commands are • Available in several languages and within the same time slot. • Can be used in routine exams like brain.
aligned with the patient’s respiratory cycle and can be selected to fit customizable for local pronunciation or for a
patient conditions, such as expiration versus Inspiration. staff member’s voice if desired. • Can be applied with high gradient settings.
• Allows export of customized settings to other • Easy to implement and use, only few clicks
Philips MR scanners. are required to get started thanks to our
ready-to-use ExamCards.
• Texts and settings can be further adapted to
meet operator preferences.
ScanWise Implant software helps you to confidently scan patients Additional information: SmartExam1 Brain assists in Additional information:
within the MR Conditional limits by providing step-by-step delivering reproducible planning
guidance to enter the condition values of the implant manufacturer. results in more than 80% of
Your MR system then automatically applies these values for the • Streamline your workflow with easy set-up procedures by using intelligent • Dedicated 3D survey scan is included to
entire examination helping you to simplify your scanning process of scanning parameters as to adhere to the software which automatically determine patient positioning.
for patients with MR Conditional implants. implant’s safety conditions, for all scans just plans the scanning geometries,
once. based on your validated scanning • Automated planning of the imaging stack is
preferences. This enables you based on anatomic landmarks relating those to
• Increase referrals of patients with MR to standardize your MRI exam a previously defined planning.
Conditional implants to your institution by process helping you to enhance
confidently offering MR imaging to this growing consistency in follow-up exams • SmartExam planning can be adapted and
patient population. of the same patient and from expanded to fit changing requirements.
patient to patient. Enhanced consistency in follow-up exams
• Automated geometry planning can be shared
and applied across Philips MRI consoles.
SmartExam Spine1 assists in Additional information: SmartExam Shoulder1 assists in Additional information:
delivering reproducible planning delivering reproducible planning
results in more than 80% of results in more than 80% of
procedures by using intelligent • Dedicated 3D survey scan is included to procedures by using intelligent • Dedicated 3D survey scan is included to
software which automatically determine patient positioning. software which automatically determine patient positioning.
plans the scanning geometries, plans the scanning geometries,
based on your validated scanning • Automated planning of the imaging stack is based on your validated scanning • Automated planning of the imaging stack is
preferences. This enables you based on anatomic landmarks relating those to preferences. This enables you based on anatomic landmarks relating those to
to standardize your MRI exam a previously defined planning. to standardize your MRI exam a previously defined planning.
process helping you to enhance process helping you to enhance
consistency in follow-up exams • SmartExam planning can be adapted and consistency in follow-up exams Consistent reading for any patient • SmartExam planning can be adapted and
of the same patient and from expanded to fit changing requirements. of the same patient and from expanded to fit changing requirements.
patient to patient. patient to patient.
• Includes numbering of the vertebrae and • Automated geometry planning can be shared
automatically matches the planning of the axial and applied across Philips MRI consoles.
Consistent reading for any patient stacks to the disc’s orientation.
SmartExam Knee1 assists in Additional information: O-MAR (Metal Artifact Reduction Additional information:
delivering reproducible planning for Orthopedic implants) allows
results in more than 80% of you to improve visualization of
procedures by using intelligent • Dedicated 3D survey scan is included to more soft tissue and bone in the • Reduction of susceptibility artifacts2 caused by
software which automatically determine patient positioning. near vicinity of MR Conditional metal implants1.
plans the scanning geometries, orthopedic implants1. This allows
based on your validated scanning • Automated planning of the imaging stack is you to offer post-operative MR • Supports most relevant image contrasts
preferences. This enables you based on anatomic landmarks relating those to imaging to patients with implants (T1w, T2w, PDw, and STIR).
to standardize your MRI exam a previously defined planning. who could develop implant-
process helping you to enhance related conditions. • Extending MARS (Metal Artifact Reduction
consistency in follow-up exams Consistent reading for any patient • SmartExam planning can be adapted and Traditional T2w TSE (left) versus T2w TSE O-MAR (right) Sequence) with the View Angle Tilting (VAT)
of the same patient and from expanded to fit changing requirements. technique.
patient to patient.
• Automated geometry planning can be shared
and applied across Philips MRI consoles.
mDIXON XD FFE provides Additional information: Whole Body package supports automated head-
more efficient fat-free imaging to-toe imaging coverage. By allowing an extended
in routine scan times. Improve table stroke, it enables whole-body, multi-station,
your fat-free imaging over large • Improved fat-free imaging over large feet-first imaging studies. You can perform all
field-of-views and for high 400-500 mm FOV and for sub-millimetric required imaging sequences per station, reducing
resolution imaging. With up to resolution1. the amount of required table movements.
four image types in one single
scan, including with or without • More efficient, faster scanning2.
fat suppression contrasts,
mDIXON XD FFE will enable • Increased signal-to-noise ratio2.
you to enhance your imaging Multiple image contrasts in one single scan
strategies by simplifying your • Acquire up to four image types in one single
routine FFE procedures. scan (water only, in phase, out phase, fat only)
3D VANE XD Page 25
Free breathing abdominal imaging
20 21
MultiVane XD mDIXON XD TSE
Replace all your FatSat
Motion-free imaging by one single fat-free
in short scan time imaging solution
MultiVane XD delivers high resolution diagnostic mDIXON XD TSE brings a new Additional information:
images even in the case of severe patient motion dimension to fat suppression
by providing motion correction to a full range of by providing uniform, complete
anatomies, in short scan times1. MultiVane XD works and consistent fat-free imaging, • 30% faster scanning and up to 30% reduced
in multiple orientations and for various contrasts even over large field-of-views blurring1.
(T1w, T2w, FLAIR) helping you to increase your and in challenging anatomies.
diagnostic confidence. Providing up to four image types • Increased signal-to-noise ratio2.
in one single scan, including
with/without fat suppression • Acquire up to four image types in one single
contrasts, in routine scan times scan (water only, in phase, out phase, fat only).
and resolution simultaneously, With/without fat suppression contrasts, simultaneously
you can easily replace your
favorite routine TSE scans with
Diagnostic images, even in the case of severe patient motion it. mDIXON XD TSE will enable
you to enhance your imaging
strategies by simplifying your
routine TSE procedures.
Free breathing
abdominal imaging
Suite Premium
The dS PerformanceSuite
Premium will complement the dS Compressed SENSE Body Compressed SENSE Cardiac
Page 30 Page 31
PerformanceSuite Pro by bringing Speed done right, every time Speed done right, every time
26 27
Compressed SENSE Neuro and Spine Compressed SENSE MSK
To meet the increased demand for Additional information: To meet the increased demand for productivity, a Additional information:
productivity, a technology break-through technology break-through in acceleration is required.
in acceleration is required. Leveraging Leveraging our long standing leadership position in
our long standing leadership position • Available for multiple cartesian scan speed (i.e. SENSE), Philips brings a breakthrough in • Available for multiple cartesian scan
in speed (i.e. SENSE), Philips brings a techniques like FFE, SE, TFE and TSE. productivity. Compressed SENSE is about accelerating techniques like FFE, SE, TFE and TSE.
breakthrough in productivity. Compressed full patient examinations to empower your staff to
SENSE is about accelerating full patient • Available for all anatomical contrasts focus where it matters the most, enhanced patient • Available for all anatomical contrasts
examinations to empower your staff to (e.g. T1, T2, PD, FLAIR, DIR, fat sat). care. This new paradigm in productivity is available for (e.g. T1, T2, PD, FLAIR, DIR, fat sat).
focus where it matters the most, enhanced MSK imaging, for all anatomical contrasts, and not only
patient care. This new paradigm in • A break-through acceleration technique 3D scans but also 2D scans are significantly faster (up • A break-through acceleration technique
productivity is available for Neuro and speeding up not only sequences but your to 50%). speeding up not only sequences but your
Spine imaging, for all anatomical contrasts, entire exam. entire exam.
and not only 3D scans but also 2D scans Fast 2D Brain imaging Fast 2D MSK imaging
are significantly faster (up to 50%). • Unique implementation enabling 2D and 3D • Unique implementation enabling 2D and 3D
scans to be up to 50% faster with virtually scans to be up to 50% faster with virtually
equivalent image quality1. equivalent image quality1.
28 1 Compared to scans without Compressed SENSE 1 Compared to scans without Compressed SENSE 29
Compressed SENSE Body Compressed SENSE Cardiac
To meet the increased demand for productivity, Additional information: To meet the increased demand for productivity, Additional information:
a technology break-through in acceleration is a technology break-through in acceleration is
required. Leveraging our long standing leadership required. Leveraging our long standing leadership
position in speed (i.e. SENSE), Philips brings a • Available for multiple cartesian scan position in speed (i.e. SENSE), Philips brings a • Available for multiple cartesian scan
breakthrough in productivity. Compressed SENSE techniques like FFE, SE, TFE and TSE. breakthrough in productivity. Compressed SENSE techniques like FFE, SE, TFE and TSE.
is about accelerating full patient examinations is about accelerating full patient examinations to
to empower your staff to focus where it matters • Available for all anatomical contrasts empower your staff to focus where it matters the • Available for all anatomical contrasts
the most, enhanced patient care. This new (e.g. T1, T2, PD, FLAIR, DIR, fat sat). most, enhanced patient care. This new paradigm (e.g. T1, T2, PD, FLAIR, DIR, fat sat).
paradigm in productivity is available for Liver, in productivity is available for Cardiac imaging, for
Prostate, Breast and Whole Body imaging, for all • A break-through acceleration technique all anatomical contrasts, and not only 3D scans • A break-through acceleration technique
anatomical contrasts, and not only 3D scans but speeding up not only sequences but your but also 2D scans are significantly faster speeding up not only sequences but your
also 2D scans are significantly faster (up to 50%). entire exam. (up to 50%). entire exam.
Fast 2D imaging with a short breath hold Fast 2D Cardiac imaging with a short
breath hold
• Unique implementation enabling 2D and 3D • Unique implementation enabling 2D and 3D
scans to be up to 50% faster with virtually scans to be up to 50% faster with virtually
equivalent image quality1. equivalent image quality1.
30 1 Compared to scans without Compressed SENSE 1 Compared to scans without Compressed SENSE 31
dS Neuro
Suite Plus
3D SpineVIEW Page 34 SWIp Page 35
View your 3D TSE imaging data in Exquisite susceptibility contrast
any plane
32 33
3D SpineVIEW SWIp
3D SpineVIEW is an advanced Additional information: SWIp has a high sensitivity Additional information:
3D TSE technique that lets you to enhance contrast for
acquire high resolution data in deoxygenated (venous) blood or
multiple directions, including • Isotropic voxel size enabling reformats in any calcium deposits and may help • High signal-to-noise ratio1.
oblique, in one scan helping you plane without loss of resolution. you, when used in combination
enhance your confidence when with other clinical information, • Includes detailed phase maps to support
diagnosing lesions. • Allows for up to 20% shorter scan times1. in the diagnosis of various advanced diagnosis.
neurological pathologies.
• Available for a range of contrasts. SWIp offers high resolution 3D
susceptibility weighted brain
imaging allowing you to easily
integrate it into your mainstream
practice. 3D susceptibility weighted brain imaging, including phase maps
Black Blood imaging helps you Additional information: Spectroscopy Specialist provides extra information about the spatial distribution of
better differentiate the vessel metabolites in the brain. This package provides a set of single voxel, multi-voxel and
lumen from the intra lumen multi-slice proton spectroscopy, fully integrated into the MRI console. To reduce scan
blood signal. This enhances • Fast scan times3 of five minutes. time, a combination of Turbo Spectroscopic Imaging and dS SENSE can be used.
your diagnostic confidence by Anisotropic matrix can be used to further reduce acquisition time. Includes SpectroView
performing your 3D brain imaging • 3D isotropic acquisition enables reformats in Analysis package for visualization and processing of all spectroscopic data.
with higher and isotropic imaging any plane (including oblique) without loss of
resolution1 with a reduction of resolution.
the intra-lumen brain blood
signal2 over the complete imaging
volume. Reduction of the intra-lumen brain blood signal
Spectroscopic imaging
1 Compared to our 2D double inversion methods with same brain coverage and scan time. 3 Compared to our 2D double inversion recovery methods
36 2 Compared to our 3D T1w scan without MSDE pre-pulse. with same full brain coverage. 37
dS Neuro Suite Pro 3D NerveVIEW
Review nerve plexus,
Page 40
non-invasively
38 39
3D NerveVIEW Zoom Diffusion
Small FOV diffusion
Review nerve plexus, imaging for improved
non-invasively image quality
3D NerveVIEW improves visualization of the Zoom Diffusion allows you to acquire small FOV
brachial and lumbar plexus by providing you with imaging, down to 200 x 50 mm, with reduced
a high resolution T2w TSE acquisition with reduced geometrical distortion, due to reduced EPI echo
remaining intra-lumen signal of the veins1. In train length in DWI-EPI compared to conventional
addition, the 3D isotropic imaging method allows full FOV DWI-EPI, and higher spatial resolution,
for reformats in any plane (including oblique) due to smaller acquisition voxel size compared to
without loss of resolution helping you to save scan full FOV DWI-EPI, with same level of geometrical
time and improve spinal nerve plexus assessment. distortion.
Improved visualization of the spinal nerve plexus Small FOV diffusion imaging with high spatial resolution
40 1 By use of MSDE black blood pre-pulse with STIR/SPAIR, compared to our STIR/SPAIR sequence without MSDE pre-pulse. 41
DTI FiberTrak
Visualize specific white matter fiber tracts in the brain with Diffusion
Tensor Imaging (DTI) data and fiber tracking. This package allows you
to trace, analyze and process fibers in real-time with minimal mouse
clicks. It supports pre-operative surgical planning, post-surgery
evaluation, and general evaluation of fiber tracts around tumors and
lesions in connection with functional areas. DTI FiberTrak supports up
to 32 directions and 16 b-values and includes automatic calculation of
Fractional Anisotropy (FA) maps.
42 43
dS Neuro Suite
Premium
Bold Page 46
Motion-free imaging in short scan
time
44 45
BOLD 3D ASL
Accurately acquiring fMRI BOLD data during 3D ASL enables you to consistently quantify
neuro imaging helps visualize task-related areas brain perfusion with an accuracy of 15%1 in a
of activation in the brain. The fMRI paradigms that non-contrast manner with full brain coverage,
deliver and control stimuli are fully automated via and better background suppression, compared
dedicated ExamCards to make fMRI fast, easy, and to 2D pCASL method. 3D ASL includes fully
reliable. The iView BOLD analysis package provides automated calculation of color coded ASL maps.
real-time processing of fMRI BOLD data into
functional activation maps.
Visualize task-related areas of activation in the brain Quantification of brain perfusion in a non-contrast manner
48 49
O-MAR XD 2k imaging
O-MAR XD (Metal Artifact Additional information: 2k Imaging offers a scan matrix of 2048 x 2048, providing high resolution
Reduction for Orthopedic even with large FOVs, or lower resolution scans with a 2048 matrix
implants) allows you to improve reconstruction. Compatible with all imaging methods.
visualization of more soft tissue • Reduction of in- and throughplane
and bone in the near vicinity susceptibility artifacts2 caused by metal
of MR Conditional Orthopedic implants1.
implants1. This allows you to
offer postoperative MR imaging • Supports most relevant image contrasts
to patients with implants who (T1w, T2w, PDw, and STIR).
could develop implant-related
conditions. Traditional PDw TSE (left) versus PDw TSE O-MAR XD (right) • Extending MARS (Metal Artifact Reduction
Sequence) with the View Angle Tilting (VAT)
and Slice Encoding for Metal Artifact Correction
(SEMAC) techniques. Ultra high resolution imaging
52 53
3D PelvisVIEW 4D-THRIVE/BLISS
Accelerate dynamic
View your 3D TSE body and breast
imaging data in any plane imaging
Data in multiple directions, in one scan 2 Due to time-efficient, low SAR flip angle sweep technology.
54 Compared to standard 3D TSE. 55
dS Liver Suite mDIXON Quant Page 58
Non-invasive liver fat fraction
quantification
56 57
mDIXON Quant MR Elastography
mDIXON Quant brings a fast and Additional information: MR Elastography allows for a Additional information:
simple 3D procedure for non- non-invasive assessment of
invasive liver fat quantification differences in tissue stiffness
by providing high quality 3D • Single breathhold acquisition. of the liver in a fast breathhold • Image processing is fully integrated at the
fat fraction maps of the whole scan providing trained physicians scanner.
liver, even for short T2*, with • Based on state of the art 6-echo acquisition, with additional input to help
high accuracy (± 3.5%) and 7-peak fat modeling reconstruction, correction make informed decisions about • Automated calculation of Elastograms,
reproducibility (± 1.4%)1 allowing for T2* confounding effect and low flip angle treatment. reflecting tissue stiffness in kPa.
you to expand your MRI to minimize T1 bias.
capabilities. T2*/R2* relaxation • Statistical confidence map is provided for
maps are provided to further help Fat fraction maps (left) and T2*/R2* relaxation maps (right) • Fat fraction maps are displayed in colors with Elastograms reflecting tissue stiffness in kPa reliability assessment.
your diagnostic assessment. a quantification bar.
1 Accuracy and reproducibility were assessed using a reference liver protocol, on fat phantoms [range: 0-100%].
58 Reproducibility assessed over systems. 59
dS Breast Suite SmartExam Breast
Consistent fat suppression
Page 62
60 61
SmartExam Breast 3D BreastVIEW
1 SmartExam is not available to patients with 1 Due to time-efficient, low SAR flip angle sweep technology.
Consistent fat suppression for every patient
62 MR Conditional implants. Compared to standard 3D TSE. 63
dS Cardiac Suite Pro Cardiac Expert
Expand your cardiac MR
Page 66
functionality
64 65
Cardiac Expert CardiacQuant
Non-invasive
Expand your cardiac assessment of
MR functionality myocardial tissue
Cardiac Expert supports the acquisition of multi- With CardiacQuant you get access to
T2* map T2 map T1 map
slice, dynamic tissue studies with T1 weighting exciting new applications for cardiology,
and uniform tissue suppression1 by including which can help in the non-invasive
Look Locker methods for determining an optimal assessment of myocardial tissue
inversion delay time. Cardiac Expert also provides characteristics by providing you with
myocardial tagging2 to allow assessment of regional comprehensive graphs and pixel-based,
wall motion and allows for real-time interactive quantitative information in different
planning of challenging cardiac views. regions of the myocardium helping you
to make early decisions for therapy. Quantitative T2*, T2 and T1 maps in a single breathhold scan
→ Slices
→ Dynamics
1 With a (B1 insensitive) saturation pre-pulse
66 2 By means of REST grids 67
dS Cardiac Suite
Premium
k-t BLAST Page 70
Accelerate your cardiac studies
68 69
k-t BLAST Coronary Acquisition
Perform non-invasive
Accelerate your imaging of coronary
cardiac studies arteries
K-t BLAST provides up to five fold acceleration using Coronary Acquisition allows for non-invasive
an alternative parallel imaging technique employing imaging of coronary arteries by displaying good
undersampling in time and space. Suited for dynamic contrast between myocardium and vessels
and real-time cardiac studies as well as single breath by deploying 3D sequences combined with
hold, multi-slice cine studies. Can be combined with MotionTrak respiratory navigators for real-time
most other imaging methods. motion correction and T2-preparation.
70 71
dS Vascular Suite 4D-TRANCE
Contrast-free imaging of
Page 74
72 73
4D-TRANCE 4D-TRAK XD
Flexibility in your
Contrast-free imaging of MR Angiography
brain vascular anatomy studies
4D-TRANCE is a time-resolved technique for non- 4D-TRAK XD provides a fast, dynamic contrast-
contrast angiography, promoting patient comfort enhanced MR Angiography method with flexible
and enabling you to evaluate the patency of the sampling of both the arterial- and venous phase, by
vascular anatomy in the brain using endogenous applying view sharing technique, enabling high spatial
contrast with MIP visualization of multiple phases. and temporal resolution simultaneously.
4D-TRANCE enables high temporal resolution
down to 160 msec.
of coils and accessories can help you differentiate torso and cardiac studies
78 79
dS Ped NeuroSpine coil dS Ped Torso coil
High SNR for your High SNR for your
pediatric brain pediatric torso and
and spine studies cardiac studies
The dS Ped NeuroSpine 8ch coil is an open- The dS Ped Torso coil is a dedicated 8-element coil
design 8-element coil for high resolution pediatric designed to provide excellent pediatric torso and
brain and spine imaging. Specifically designed for cardiac imaging. The coil is optimized for neonates,
neonates, but will accommodate pediatric patients but will accommodate pediatric patients up to 10kg.
up to 10kg. Open, cradle shaped design enables the Split design allowing the top of the coil to be taken off,
operator to position and prepare the patient outside enabling easy access to the patient. An insert cradle can
the examination room. Examinations of brain and be used for additional patient support. A surrounding
spine can be performed without having to move the mattress is available to accommodate larger patients.
patient.
T2w and T1w Spine imaging 3D T1w Brain imaging T2w abdominal imaging Cardiac cine imaging
80 81
Pediatric positioning pack
82 83
A la carte FiberTrak Extension 3D APT Page 87
Enhanced diagnostic confidence
MultiBand SENSE
High acceleration for your
Page 88 NeuroScience
Explore brain connectivity
Page 89
Page 86
High definition fiber tracking in neuro oncology fMRI and DTI sequences
in the brain or spine
Next, to all the previously mentioned packs, there is also the option to
choose the various software applications individually. All the options that
are available on the packaging are also available individually, according
to regulatory approval and system compatibility. However, if a package is
selected the individual applications of that package cannot be selected Real-Time Specialist Page 90
Benefit from intuitive planning
StarQuant
Non-invasive assessment
Page 91 CardiacQuant Extension Page 93
Flexibility in creation of
a-la-carte. Furthermore, there are also some applications that are only for cardiac studies
of myocardial tissue
T1 maps for cardiac
84 85
FiberTrak Extension 3D APT
High definition Enhanced diagnostic
fibertracking in confidence in
the brain or spine Neuro oncology
The FiberTrak Specialist Extension package Allows 3D APT (Amide Proton Transfer) is a new unique, Additional information:
for diffusion imaging with up to 128 b-vectors and contrast-free, brain MR imaging method addressing
16 b-values, delivering input for very high definition the need for more confident diagnosis in neuro
fiber tracking in the brain or spine. oncology. 3D APT uses the presence of endogenous • 3D APTw images are calculated automatically
cellular proteins, to produce an MR signal that and displayed as color maps
directly correlates with cell proliferation, a marker
of tumoral activity. 3D APT can support trained • Whole glioma coverage can be obtained with
medical professionals in differentiating low grade a resolution of 2.0 x 2.0 x 5.0 mm
from high grade gliomas and, in differentiating
tumor progression from treatment effect1,2
MultiBand SENSE allows Additional information: NeuroScience comprehensive package helps you to Additional information:
you to use state-of-the-art explore brain connectivity by supporting advanced
acceleration factors in the brain acquisition schemes allowing for high-definition
by simultaneously exciting • Accelerate EPI scans in the brain with virtually brain fiber tracking, including crossing fibers and • Allows diffusion-weighted multi-shell acquisitions with up
multiple slices. Due to a shorter no impact on SNR3. advanced fMRI capabilities. to 32 b-values and up to 128 unique diffusion directions
minimum TR for fMRI, larger
anatomical coverage or higher • Reduce scan time in your diffusion weighted • Easy workflow for user defined gradient direction input
temporal resolution can be used. protocols up to 73%4.
In your DWI/DTI sequences larger • Perform your fMRI studies with enhanced nyquist ghost
anatomical coverage or higher • Acceleration factors of up to 8 for fMRI. stability and extended data storage (up to 64k images)
number of diffusion directions
can be acquired1. With MultiBand • Acceleration factors of up to 4 for diffusion MRI. • Enables monitoring of consistency in longitudinal fMRI
SENSE you can perform fMRI and fMRI exams with large anatomical coverage studies with a quality assurance tool, in line with fBRIN
DTI exams with high speed and Diffusion acquisition with a b-value standards
of 15.000
high resolution, simultaneously2.
• Includes B0 mapping for offline data correction and
image processing
Real-Time Specialist enables real-time interactive With StarQuant you get access to exciting T2* map T2 map
imaging for planning, while changing geometry and new applications for cardiology, which
contrast parameters during scanning with real-time can help in the non-invasive assessment
reconstruction. Anatomic views can be stored and of myocardial tissue characteristics by
recalled for subsequent scans. providing you with comprehensive graphs
and pixel-based, quantitative T2/R2 and
T2*/R2* maps in a single breathhold
scan helping you to make early decisions
for therapy.
Flexibility in creation
of T1 maps for cardiac
T1 map
92 92 93
Compatibility overview
Ingenia 1.5T Ingenia 1.5T HP Ingenia 1.5T CX Ingenia 3.0T Ingenia 3.0T CX
ScanTools Pro • • • • •
Towards first time right imaging
dS PerformanceSuite Plus • • • • •
dS PerformanceSuite Pro
dS PerformanceSuite Premium
dS NeuroSuite Plus
dS NeuroSuite Pro
dS NeuroSuite Premium
dS MSKSuite
dS BodySuite
dS LiverSuite
dS BreastSuite
dS PediatricSuite 1.5T
dS PediatricSuite 3.0T
dS VascularSuite
dS CardiacSuite Pro
dS CardiacSuite Premium
94 • Standard Options 95
Compatibility overview
Multiva 1.5T Multiva 1.5T Ingenia Prodiva Ingenia Elition Ingenia Elition
8ch 16ch 1.5T CX 3.0T S 3.0T X
ScanTools Pro • • • • •
Towards first time right imaging
dS PerformanceSuite Plus • • • • •
dS PerformanceSuite Pro
dS PerformanceSuite Premium
dS NeuroSuite Plus
dS NeuroSuite Pro
dS NeuroSuite Premium
dS MSKSuite
dS BodySuite
dS LiverSuite
dS BreastSuite
dS PediatricSuite 1.5T
dS PediatricSuite 3.0T
dS VascularSuite
dS CardiacSuite Pro
dS CardiacSuite Premium
96 • Standard Options 97
98
© 2018 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice.