Fire and Smoke dampers

Author: Jan Šimsa


2017
Company Mandík
Ø Family owned company since 1990
Ø Total company surface 9.000 m2,
including 2 production halls - 6.200m2
Ø 210 employees
Ø Sales
Year Sales in Mil. Eur
2016 18,1
2015 15,2
2014 11,8
2013 9,5
2012 8,2

Ø Active in 31 countries, above all inside E.U. and


in C.I.S.
Ø 55.000 fire and smoke dampers made in 2016
Ø Subsidiaries in Germany, Slovakia and Ukraine
Ø Excellent financial rating (by BISNODE
and Dun&Brandstreet, class: AAA)
HQ in Central Bohemia, Hostomice
Production Unit in Hostomice
Production Unit in Hostomice
Products overview Mandík 2017

Fire and smoke dampers Air distribution components

Air handling/conditioning units HVAC components


Products overview Mandík 2017

Industrial heating

Special application
Fire products overview
• Fire dampers FDMA, FDMB, FDMC, FDMD, CFDM, prepared FDMS
Fire ventilation and Smoke exctraction dampers, they
belong to „passive fire protection“ in buildings
MGM Grand Hotel – Las Vegas
The fire was caused by an electrical ground fault inside a wall socket.
Due to faulty smoke dampers within the ventilation duct network,
the toxic fumes circulated throughout the hotel's air circulation system,
accelerating the spread of the poisonous gases.
75 people died from smoke inhalation and carbon monoxide poisoning (many of them
in their sleep), four from smoke inhalation alone, three from burns and smoke inhalation,
only one person died from burns alone.

Collectives night club - Bucharest


Firework ignited the club's flammable polyurethane acoustic foam, and the fire spread rapidly.
27 people died from burns and smoke inhalation.
Most of the victims were poisoned by toxins released from the burning foam.
Romanian government had resigned and since then Passive Fire Protection regulations
have been improved.
Romanian authorities follows and requires strictly the EN in fire passive and active
fire protection in buildings.
Fire ventilation and Smoke exctraction dampers, they
belong to „passive fire protection“ in buildings
Lakhani House
The Lakanal House fire occurred in a tower block on 3 July 2009 in Camberwell,
London. Six people were killed, and at least twenty injured, when a high-rise fire
developed and spread through a number of flats in the twelve-storey building.
The inquest concluded that years of botched renovations had removed
fire-stopping material between flats and communal corridors, allowing
a blaze to spread, and that the problem was not picked up in safety inspections
carried out by Southwark council.

Grenfell Tower fire


The Grenfell Tower fire occurred on 14 June 2017 at the 24-storey, 67 m.
It caused at least 80 deaths and over 70 injuries.
The fire started in a fridge-freezer on the fourth floor.
The growth of the fire is believed to have been accelerated by the building's
exterior cladding. No „exit-way“ with efficient smoke extraction system
have been used.
Classification of fire dampers
according to EN 13501 – 3 A1

Ø Certificate of Constancy of Performance (CE marking)


Ø CE certified according to EN 15650
Ø Tested in accordance with EN 1366-2
Ø Classified according to EN 13501-3 A1

Ø Resistance EIS 60, 90, 120 minutes


(depending on the type and installation)
E – body compactness
I – temperature insulation
S – smoke tightness
Ø Leakage class „C“ according to EN 1751
Classification of fire dampers
according to EN 13501 – 3 A1 - explanation
Fire dampers FDMC - Label
Fire dampers - construction

Ø Galvanized metal sheet – Zn 275 gr/m2


Ø Cement Bound Matrix board – Promatect H
Ø Mechanical actuating mechanism
Ø Electromagnetic activator 230V or 24V AC/DC
Ø Electrical actuator – BL-T1, BLF-T1
Ø Terminal switch
Ø Thermal fuse
Ø Flange
Ø Tape – temperature active sealant
Ø Access door 2x, resp. 1x
Ø Labels
Actuating mechanism

1. Mechanical – contents of thermal fuse (one-time use), return spring –


actuating and moving the mechanism
2. Mechanical - by electromagnetic initiating mechanism
3. Electrical – 24 or 230V Belimo or Gruner
Juventa, or Schischek (Ex)
Fire dampers – Mandík´s possible designs
Damper design Additional digit
Manual and thermal .01
Manual and thermal, mechanism outside the body, covered in the casing .01v2
Manual and thermal with a terminal switch ("CLOSED") .11
Manual and thermal with a terminal switch ("CLOSED"), mechanism outside the
.11v2
body, covered in the casing
Manual, thermal and with an electromagnet AC 230 V .20
Manual, thermal and with an electromagnet AC 24 V .21
Manual, thermal and with an electromagnet DC 24 V .22
Manual, thermal and with an electromagnet AC 230 V, with a terminal switch
.23
("CLOSED")
Manual, thermal and with an electromagnet AC 24 V, with a terminal switch
.24
("CLOSED")
Manual, thermal and with an electromagnet DC 24 V, with a terminal switch
.25
("CLOSED")
With actuating mechanism BF 230-T (BFL, BFN 230-T) .40
With actuating mechanism BF 230-T (BFL, BFN 230-T) and with optical smoke
.41
detector MHG 231 and with supply device BKN 230 - 24 - MA (power supply AC 230
With actuating mechanism BF 24-T (BFL, BFN 24-T) .50
Se servopohonem BF 24-T (BFL, BFN 24-T) and with optical smoke detector MHG
.51
231 (power supply AC/DC 24 V)
With communication and supply device BKN 230-24 and actuating mechanism
.60
BF 24-T-ST (BFL, BFN 24-T-ST)
With communication and supply device BKN 230-24 and actuating mechanism
.61
BF 24-T-ST (BFL, BFN 24-T-ST) and with optical smoke detector MHG 231
With communication and supply device BKN 230-24MP and actuating mechanism
.62
BF 24TL-T-ST (Top-Line) for connection to MP-Bus
With communication and supply device BKN 230-24LON and with actuating
.64
mechanism BF 24TL-T-ST (Top-Line) for connection to LonWorks
Manual and thermal with two terminal switches ("OPEN", "CLOSED") .80
Manual and thermal with a terminal switches ("CLOSED", "OPEN"), mechanism
.80v2
outside the body, covered in the casing
Manual, thermal and with an electromagnet AC 230 V and two terminal switches
.82
("OPEN", "CLOSED")
Manual, thermal and with an electromagnet AC 24 V and two terminal switches
.83
("OPEN", "CLOSED")
Manual, thermal and with an electromagnet DC 24 V and two terminal switches
.84
("OPEN", "CLOSED")
Fire dampers – EU regulations/ „CE marking“

EU regulations

Ø New Construction Products Regulation (CPR) are effective from 1.7. 2013
Ø MANDÍK fire dampers have carried the CE marking from 29.8. 2012 in compliance
with EN 15650.
Ø The CE marking ensures that MANDÍK fire dampers and AHUs can be used for all
approved applications across the EU.
Ø On 1 July 2013, the European Construction Products Regulation (305/2011) has
replaced the Construction Products Directive (89/106/EEC).

Ø The Construction Products Regulation, or CPR, has become immediately effective


in all member states of the European Union.
Testing – fire dampers
Ø Certificate of Constancy of Performance

Ø CE certified according to EN 15650

Ø Tested in accordance with EN 1366-2


Ø Classified according to EN 13501-3 A1
Ø Resistance EIS 60, 90, 120 minutes
(depending on the type and installation)
E – body compactness
I – temperature insulation
S – smoke tightness
Ø Leakage class „C“ according to EN 1751
Certificate of Constancy of Performance
Declaration of performance
Installation of fire damper
• See technical specification on www.mandik.cz
• Manual is enclosed in plastic bag to each fire damper, in different
languages
Fire damper FDMA
Fire damper FDMB
Fire damper FDMC
Fire damper FDMD
Fire damper CFDM (cartridge machanical fire damper)
Oversized FDMA and FDMB – „twins composition“ and
„double twins composition“ – tested/approved
Smoke dampers with CE marking - overview

Ø SEDS

Ø SEDS-R

Ø SEDS-L

Ø MSD, MSD-W

Ø SEDM

Ø BRK-J
SEDS – smoke damper for single comparment with AA
SEDS-R – round smoke damper for single comparment
with MA
SEDS-L – multi-blade smoke damper for single
comparment with MA
MSD – round and rectangular, single blade smoke
damper for multiple comparments with AA
SEDM – rectangular, single blade smoke damper for
multiple comparments with MA
BRK- J – rectangular, multi-blade smoke damper for
multiple comparments with AA
Smoke extraction dampers, difference between MA/AA
Tempetarure in Degr. C and Time in Minutes
Example: Fire dampers on normal ventilation and
smoke dampers on smoke exhaust system

SEDS-L
FDMA/B

SEDS-L rectangular smoke damper


SEDS-R round smoke damper
FDMA/B rectangular fire damper
FDMC/FDMD/CFDM round fire damper
Smoke extraction dampers, single/multiple-
compartment
SEDS, SEDS-R, SEDS-L
MSD
SEDM
Installation, transport of fire dampers
Fire damper
• must be installed independently to the air ductwork – no connective load is allowed
• the opening and the sealing is according installation instructions – see TPM or IM (attached in
plastic bag as hard copy or QR code on label)
• for revisions use the pre-installed inspection door, opening for micro-camera or opening on
the duct
• handling and transportation of fire damper is recommended in „close“ position
Note: FDMA fire dampers has additional steel holders of blade, which have to be removed before
installation!!!
• actuator can be exceed to temperature max. 50 degr. Celsius and always in shadow place (do
not leave it on the sunshine).
Selected Refereces
Selected Refereces
Thank you for your attention!

www.mandik.com

Jan Šimsa – export director