EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.
LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.
SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
A General Requirements ... Additional Requirements Shall be as agreed upon in SAIC-RT-2010. See Note 1.
Weld has been visually examined and accepted prior to release for SAEP-1143
A6
radiography. Para. 5.3.2
Lead letter "B" is attached to the back of each film holder during each
exposure to determine if backscatter radiation is exposing the film.
SAEP-1143
A7 Note: Para. 5.4
The dimensions of letter "B" shall be 13mm (0.5 inch) of height and
1.5mm (0.0625 inch) thickness.
g) BI Number
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
Location markers are placed on the part being examined and not on
SAEP-1143
B3 the exposure holder/cassette. Location markers shall not intrude into
Para. 8.3.1
the area of interest.
The starting point and the direction of numbering shall be identified SAEP-1143
B4
adjacent to the weld. Para. 8.3.1.1
C Exposure Techniques
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
SAEP-1143
C2
Para. 7.1
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
The voltage for examinations with x-ray tubes shall be selected to SAEP-1143
D2
insure that the required IQI wire is visible on the radiograph. Para. 8.1.1
Gamma Radiation i.e Ir-192, Se-75 and Co-60 (together with the
SAEP-1143
D3 radiographic technique used) shall be selected to produce the
Para. 8.1.2
required radiographic sensitivity.
Lead intensifying screens are used and the minimum thickness of the
front lead screen is.
1. 0.13 mm (0.005 inch) for Ir-192 and Se-75. SAEP-1143
D5
2. 0.25 mm (0.010 inch) for Co-60 or the linear accelerator. Para. 6.3
Note: Lead screens which are an integral part of "ready pack"
(i.e., Pb contact pack) film are acceptable.
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
Image Quality Indicators of one of the following types are used.
A) DIN type penetrameters described in DIN 54 109.
B) ISO type penetrameters described in ISO 1027.
C) ASTM type penetrameters described in ASTM SE-747/90.
Tables 1, 2 and 3 below show the standard identification numbers
found on the penetrameter packs and the wire sizes found in the DIN
type, ISO type and ASTM type typical packs.
SAEP-1143
E1
Para. 6.4
IQIs shall be from either the same alloy material group or grade or
from an alloy material group or grade with less radiation absorption SAEP-1143
E2
than the material being radiographed. Para. 6.4.3
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
Penetrameters (IQI) shall be selected to insure the designated wire
required by Table 7 shall be included in the penetrameter pack used.
SAEP-1143
E3
Para. 8.5.1
SAEP-1143
E4 IQIs are not damaged, e.g., bent wires.
Para. 6.4.2
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
Only a source side penetrameter are used for the double wall viewing SAEP-1143
E11
technique (DWV technique). Para.7.4.1
ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
F Geometric Unsharpness
NOTES:
1. Items indicated as "Best Practice" shall be agreed upon by Contractor, SAPMT and Inspection. These will then be
incorporated in the project requirement and in the Project Quality Plan and will be mandatory for implementation.
REMARKS:
NOTES: 1. This checklist shall be utilized per SAIC-RT-2010, RT Process Control Procedure relative to Selection of NDE & Repairs
REFERENCE DOCUMENTS:
1. SAEP-1143, Radiographic Examination, (2 Oct, 2014)
2. SAEP-1141, Radiation Protection For Environmental, 12 July 2016