Koolfog Misting Design
Koolfog Misting Design
Koolfog Misting Design
1 A common mistake people make when designing a system is to plan on sitting "in" the
mist. If you're working with a covered patio area it is sometimes better to surround the
area and let the mist create a wall that actually cools the entire area. It brings the total
area temperature down and at the same time guests are not getting wet from mist
being sprayed directly at them. If the area is very wide, additional lines can be located
on the interior to allow for more cooling.
2 Remember to give yourself options when designing a system so that you can adjust
things slightly after the initial installation. For example, build in the capability of
rotating the lines slightly to adjust the angle of the mist. Remember to work around
obstructions such as speakers, televisions, umbrellas, planters, or ceiling fans. You do
not want the mist to collect and drip.
3 Every misting pump makes noise. Plan on tucking it away with other equipment like
air conditioning units or pool pumps.
4
When selecting a misting system, quality matters. Consider these factors when
determining which system is right for you:
• Does the system come with a full set of gauges that will help pinpoint
service issues?
• Are serviceable parts easily accessible?
• Do the nozzles include check valves in order to prevent dripping?
• Are the components used in the system designed to protect against dust
and water?
• Do you need a system that is enclosed to protect critical components or to
dampen sound?
MEASURE AREA
Measure the length of misting line and the distance from the pump to the misting line.
Be sure to include changes in elevations.
Koolfog's Misting System Kits make it easy to customize your outdoor cooling system. Our kits
include misting line, misting nozzles, stainless steel or nylon tubing, compression or push-in
fittings and fasteners. You only need to select your pump and nozzle type.
Kit Size 20' 30' 40' 50' 60' 70' 80' 90' 100'
See Kit See Kit See Kit See Kit See Kit See kit See Kit See Kit See Kit
Humid G2-20 , G2-20 , G2-20 , G2-20, G2-20, G2-20, G2-40, G2-40, G2-40,
M20 M20 M20 M20 M20 M20 M44 M44 M44
Dry G2-20 , G2-20 , G2-20, G2-20, G2-40, G2-40, G2-40, G2-40, G2-40,
M20 M20 M20 M20 M44 M44 M44 M44 M44
Nylon
20 20 20 20 20 20 20 20 20
Tubing
Nozzles
(Humid or 10 15 20 25 30 35 40 45 50
Dry)
3/8" SS
20 30 40 50 60 70 80 90 100
Misting Line
3/8" SS
Compression 1 1 1 1 1 1 1 1 1
Endcap
3/8" SS
Compression 2 3 4 6 7 8 9 11 12
Union
3/8" SS
Compression 2 2 2 2 2 2 2 2 2
Elbow
3/8" SS
Compression
x 1/4" SS 1 1 1 1 1 1 1 1 1
Male
Connector
Nickel Plated
Push In
2 2 2 2 2 2 2 2 2
Female
Connector
SS
Cushioned 20 25 30 35 40 45 50 55 60
Loop Clamps
Tube Cutter 1 1 1 1 1 1 1 1 1
Kit Size 20' 30' 40' 50' 60' 70' 80' 90' 100'
See Kit See Kit See Kit See Kit See Kit See kit See Kit See Kit See Kit
Humid G2-20 , G2-20 , G2-20 , G2-20, G2-20, G2-20, G2-40, G2-40, G2-40,
M20 M20 M20 M20 M20 M20 M44 M44 M44
Dry G2-20 , G2-20 , G2-20, G2-20, G2-40, G2-40, G2-40, G2-40, G2-40,
M20 M20 M20 M20 M44 M44 M44 M44 M44
Nylon
40 50 60 70 80 90 100 110 120
Tubing
Nozzles
(Humid or 10 15 20 25 30 35 40 45 50
Dry)
Nickel Plated
Nozzle Push 10 15 20 25 30 35 40 45 50
In Unions
Nickel Plated
Push In 3 3 3 3 3 3 3 3 3
Elbows
Brass Push In
1 1 1 1 1 1 1 1 1
Plug
Nickel Plated
Push In
1 1 1 1 1 1 1 1 1
Female
Connector
SS
Cushioned 20 25 30 35 40 45 50 55 60
Loop Clamps
Tube Cutter 1 1 1 1 1 1 1 1 1
Contact
one
of
our
design
engineers
for
a
custom
plan
for
your
needs
at
+1
760-‐321-‐9203.