Nothing Special   »   [go: up one dir, main page]

Analisa Balok 400

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Project Job Ref.

TUGAS AKHIR
Section Sheet no./rev.

JTS FT UNRAM 406*403 1


Calc. by Date Chk'd by Date App'd by Date
ILMANSYAH 10/10/2017

STEEL MEMBER DESIGN (AISC 360)


In accordance with AISC360 14th Edition published 2010 using the LRFD method
Tedds calculation version 4.3.01

Resistance factors
Shear; v = 0.90
Flexure; b = 0.90
Tensile yielding; t,y = 0.90
Tensile rupture; t,r = 0.75
Compression; c = 0.90

Design section 1
Section details
Section type; UC 400x400x197 (JIS)
ASTM steel designation; A992
Steel yield stress; Fy = 345 N/mm2
Steel tensile stress; Fu = 448 N/mm2
Modulus of elasticity; E = 199948 N/mm2

UC 400x400x197 (JIS)
21

Section depth, d, 400 mm


Section breadth, bf, 408 mm
Weight of section, Weight, 1.776 kN/m
Flange thickness, tf, 21 mm
Web thickness, tw, 21 mm
Area of section, A, 25070 mm2
Radius of gyration about x-axis, rx, 168.157 mm
Radius of gyration about y-axis, ry, 97.454 mm
400

Elastic section modulus about x-axis, Sx, 3544400 mm3


Elastic section modulus about y-axis, Sy, 1167120 mm3
Plastic section modulus about x-axis, Zx, 3992460 mm3
21 Plastic section modulus about y-axis, Zy, 1793740 mm3
Second moment of area about x-axis, Ix, 708881000 mm4
Second moment of area about y-axis, Iy, 238093000 mm4
21

408

Analysis results
Required flexural strength - Major axis; Mr,x = 296.7 kNm
Required shear strength - Major axis; Vr,x = 302.85 kN
Restraint spacing
Major axis lateral restraint; Lx = 7000 mm
Minor axis lateral restraint; Ly = 7000 mm
Torsional restraint; Lz = 7000 mm
Classification of sections for local buckling - Section B4
Classification of flanges in flexure - Table B4.1b (case 10)
Width to thickness ratio; bf / (2  tf) = 9.71
Limiting ratio for compact section; pff = 0.38  [E / Fy] = 9.15
Project Job Ref.
TUGAS AKHIR
Section Sheet no./rev.

JTS FT UNRAM 406*403 2


Calc. by Date Chk'd by Date App'd by Date
ILMANSYAH 10/10/2017

Limiting ratio for non-compact section; rff = 1.0  [E / Fy] = 24.08; Noncompact

Classification of web in flexure - Table B4.1b (case 15)


Width to thickness ratio; (d - 2  k) / tw = 14.95
Limiting ratio for compact section; pwf = 3.76  [E / Fy] = 90.55
Limiting ratio for non-compact section; rwf = 5.70  [E / Fy] = 137.27; Compact
Section is noncompact in flexure
Design of members for shear - Chapter G
Required shear strength; Vr,x = 302.9 kN
Web area; Aw = d  tw = 8400 mm2
Web plate buckling coefficient; kv = 5
(d - 2  k) / tw <= 2.24  (E / Fy)
Web shear coefficient - eq G2-2; Cv = 1.000
Nominal shear strength - eq G2-1; Vn,x = 0.6  Fy  Aw  Cv = 1737.5 kN
Resistance factor; v = 1.00
Design shear strength; Vc,x = v  Vn,x = 1737.5 kN
Vr,x / Vc,x = 0.174
PASS - Design shear strength exceeds required shear strength

Design of members for flexure - Chapter F


Required flexural strength; Mr,x = 296.7 kNm
Plastic moment - eq F2-1; Mp,x = Fy  Zx = 1015.1 kips_ft

Lateral-torsional buckling - Section F3.1


Unbraced length; Lb = Ly_s1 = 7000 mm
Limiting unbraced length for yielding - eq F2-5; Lp = 1.76  ry  (E / Fy) = 4131 mm
Distance between flange centroids; ho = 384 mm
c=1
rts = 110 mm
Limiting unbraced length for inelastic LTB - eq F2-6;Lr = 1.95  rts  E / (0.7  Fy)  ((J  c / (Sx  ho)) + ((J  c / (Sx  ho))2 +
6.76  (0.7  Fy / E)2)) = 15311 mm
LTB modification factor; Cb = 1.000
Nominal flexural strength for lateral-torsional buckling - eq F2-2
Mn,ltb,x = min(Cb  (Mp,x - (Mp,x - 0.7  Fy  Sx)  (Lb - Lp) / (Lr - Lp)), Mp,x) =
1242.6 kNm
Compression flange local buckling - Section F3.2
 = bf / (2  tf) = 9.714
Nominal flexural strength for compression flange local buckling - eq F3-1;
Mn,flb,x = Mp,x - (Mp,x - 0.7  Fy  Sx)  ( - pff) / (rff - pff) = 1356.7 kNm

Design flexural strength - F1


Nominal flexural strength; Mn,x = min(Mn,ltb,x, Mn,flb,x) = 1242.6 kNm
Design flexural strength; Mc,x = b  Mn,x = 1118.4 kNm
Mr,x / Mc,x = 0.265
PASS - Design flexural strength exceeds required flexural strength
Project Job Ref.
TUGAS AKHIR
Section Sheet no./rev.

JTS FT UNRAM 406*403 3


Calc. by Date Chk'd by Date App'd by Date
ILMANSYAH 10/10/2017

You might also like