Webinar Kice Baghouse Basics PDF
Webinar Kice Baghouse Basics PDF
Webinar Kice Baghouse Basics PDF
• Magnehelic Gauge
• Measures Pressure Differential across filter bags
• The difference in static pressure upstream (dirty air side)
and downstream (clean air side) of the bags = pressure
drop.
• Magnehelic gauge mounted to filter, visible to operator.
– EXAMPLE:
• 8,000cfm air required for dust control
• Kice VR96-10 Filter offers 1,131ft² of filtration area
– EXAMPLE:
• 8,000cfm air required for dust control
• Kice VR96-10 Filter offers 43.43ft² of open area between bags
When valve
operating correctly,
will feel slight
“puff/blast” of air
here when operated
Baghouse Cleaning System – Low Pressure/High Volume
Kice Pneu-Jet Valve
Baghouse Cleaning System Valve & Solenoid Problems
Kice Pneu-Jet Valve or any
“PD Blower air system
• Cracked large or small diaphragm
• Worn seat
• Broken spring
• Solenoid epoxy coil loose or open
– (Red Hat missing)
• 3” gasket to lateral leaking/dried out
• PD blower issues
When valve
operating correctly,
will feel slight
“puff/blast” of air
here when operated
Troubleshooting Issues
• Condensation / moisture within baghouse: