FOR
1|Page
INTRODUCTION: Opened-cycle
cycle cooling water(OCCW) from the condenser circulating water inlet
pipe, through the OCCW pump pressure, supplied to users, and return to the circulating water return
pipe, this system mainly provide cooling water to the generator hydrogen cooler, the generator stator
cooling water cooler, MD-BFP BFP work oil cooler, lu
lubricating
bricating oil cooler, motor air cooler, A, B TD-BFP
TD
lubricating oil cooler, A, B condensate pump motor cooler, CCCW cooler, vacuum pump cooler, turbine
lubricating oil cooler, forced draft fan, induced draft fan, primary air fan, mill lube oil station, air
compressor and provide miscellaneous water to the turbine house.
2|Page
SAFTEY PRECAUTIONS:
1. Ensure no permit to work is pending on regarding this system by checking with EE/MRSE.
3|Page
OPERATING PROCEDURE -
Sr. RESPONSIBILITY
Description
No. UCE DE FE EE
PRE- START CHECKS:
1 All permits and cross permits have been returned. √ √ √ √
2 Power supply and control power supply available. √ √
3 Oil level in Bearing and Gear box √ √
4|Page
START Permissive :
1 OCCWP inlet MOV opened √
5|Page
2 Stop the Pump giving stop command from DCS, discharge MOV will be √
closed in Auto.
2 Cases:- √
Emergency shutdown
1 Press the emergency push button of faulted pumps immediately and pump
stops. √
2 Release the interlocking switch of faulted pumps and the operating pump √
should be normal. √
3 Report to the shift incharge and work order raised for removing the fault , √
put it into standby after removing fault. √
6|Page
ABRIVIATIONS / NOTATIONS
NOTATIONS:-
o SOP: Standard Operating
perating Procedure
o UCE: Unit Control Engineer
o DE: Desk Engineer
o FE: Field Engineer
o DCS: Distributed Control
ontrol System
o EE:: Electrical Shift Engineer
Important Note:--
7|Page