710 1.

0 e

KRT RETENTION MEASUREMENT

Retention measurement system


for monitoring and control
KPM offers a retention measurement system for
paper machine retention monitoring and control.
KPM KRT retention package is applicable for
paper and board machines with or without ash
addition.
All needed hardware is included in the system
where separate configuration for headbox and
whitewater measurements are available. KPM
KRT retention package measures total consistency
of the headbox and whitewater sample.
Measurement range is 0–1.5% Cs. The
sensor measures fibers and particles from 0.01%
(100ppm) to 1.5%, (depending on type of stock).
The measuring principle is based on the ability
of fibers to depolarize light to a much greater
degree than denser solid particles.

Connection to headbox and whitewater


KPM KRT by-pass sensors are connected to the
headbox and the whitewater with sample valve
and PP sample line. The whitewater sensor
includes an automatic backflush valve that keeps
the sensor and sample line clean. The whitewater
sensor can also be equipped with a deaeration
device and a sample pump.
The sensors measure total consistency of the
sample and the consistency signals are
connected to DCS, where retention is calculated.

No maintenance needed
The sensor has a 3 mm gap between the lenses,
which produces a self-cleaning effect due to the
increased velocity. In addition, automatic flushing
with 3-way valves can be supplied to keep the
sensors clean without maintenance. Each sensor
can have four remotely selectable calibration
curves for applications with varying furnishes.

Robust design in SS316 steel


The sensor is constructed of 316SS with
unbreakable stainless steel sample funnel, making
the sensors withstand the most aggressive
media. The sensor pressure class is PN10.
The display unit and sensor have protection class
of IP65 (Nema 4X) and do not need protective
housing to stand difficult conditions at the paper
machine wet end.
Output signal 4 - 20 mA
Binary inputs 5 binary inputs 24 VDC, process stop, Inverter alarm, sampling and 2 for remote
calibration selection
Binary output 3 relay outputs for alarm, flushing control and pump, Max 110VAC or 24VDC, 2 A
Total Consistency range 0 – 1.5 %
Process temperature 10 – 60 °C (50 – 140 °F)
Process pressure max 10 Bar (140 psi)
Sample flow rate minimum 10 l/min (2.5gmp)
Pressure Class PN10 (150 psi)
Process Connection sample tab 3/4 in
Minimum consistency 0.01 %, 10 ppm
Ambient temperature Sensor, 0 - 60°C (32 - 129°C )
Cabling 10 m interconnect cable from Sensor to Display Unit; max 5 cables in series
Wetted materials 316 SS
Flushing water temperature 25 – 60 °C (77 – 129°F)
Flushing water pressure 2 – 6 Bar (30 – 90 psi)
Instrument air 4 – 8 Bar (60 – 120 psi)
Conformance 73/23/EEC, 89/336/EEC, EN 61000-6-4:2001, EN 61000-6-2:2001, EN 61010-1:2001
Enclosure class IP65, Nema 4X
Power supply 85–250 VAC, 50/60Hz; 20VA

Dimensions Weight
HB sensor 850 x 1250 x 550 mm (33 x 50 x 22 in) 23 kg (110 lbs)
WW sensor 850 x 1250 x 550 mm (33 x 50 x 22 in) 50 kg (110 lbs)

www.prokajaani.com

KAJAANI PROCESS MEASUREMENTS Ltd., Kettukalliontie 9 E, FIN-87100 Kajaani, FINLAND. Phone: +358 10 548 7600. Fax: +358 8 612 0683. E-mail: kpm@prokajaani.com
KPM products comprise applications for consistency control, sampling and sheet break detection – and represent the most progressive solutions of the field. All prod-