HQ Catalog PDF
HQ Catalog PDF
HQ Catalog PDF
2009.4.17
7:30
PM페이지20
ELECTRIC ACTUATOR
HQ - SERIES
Weather proof
Explosion proof
Special options
Valve Automation
www.hkcon.co.kr
HKC CO.,LTD We, HKC, thank all of you for giving us endless
support and heartfelt advice for the progress of the
company.
We will keep our best efforts to be a global leading corporation of valve automation industry in 21st century by
creating a great contribution towards the future of the world with the best quality products, endless development of
technical know-how, and perfect customer service.
Best Regards,
S. M. Han
President of HKC.Co.,Ltd.
HQ20P카탈로그
2009.4.17
7:32
PM페이지4
4 5
HQ20P카탈로그
2009.4.17
7:32
PM페이지6
Manual
handle
Indicator sustained by spring
Mechanical
stoppers - Direction of visual indicator is set by factory.
(rear side) - In case of changing it's direction, just grip the indicator plate
and change the position.
- Spring beneath indicator plate sustains the set position
unchanged.
Dual conduit connection - No need to loose screw and tight it again at all !
(rear)
6 7
HQ20P카탈로그
2009.4.17
7:33
PM페이지8
%
PCU Proportional control unit (input, output 0~10V DC, 4~20mA DC) HQ-series
00
Additional torque switches (SPDT x 2EA 250V AC 10A Rating) except HQ-008/010
70 ty
ATS
~1
Du
LCU-B lntegral control (LCU + IMS + phase protect indicator) except HQ-008/010
LCU-C Digital display control (LCU + IMS + auto phase discriminator) except HQ-008/010
CPT Current position transmitter (output 4~20mA DC) HQ-series
EXT Extension 120 , 180 , 270 turn except HQ-200, 300
RBP Rechargeable battery backup HQ-008/010, 015, 020, 030
DCM DC motor (24V DC) HQ-008/010, 015, 020, 030
ADCM Multi AC/DC 24V(integral) HQ-008/010, 015, 020, 030
LPA Lever plate actuator except HQ-008/010
SLU Signal lamp unit (white-power on, red-open, green-close, yellow-over torque) except HQ-008/010
FPA1 Fire Proofing Actuator 1050 5 / 50min Engineering consult in advance
FPA2 Fire Proofing Actuator 250 5 / 150min Engineering consult in advance
Performance
Maximum Operating Maximum Motor class F Rated current(A) 60Hz/50Hz Duty Number
HQ output time(sec.) bore size power( W ) cycle of handle Weight
torque 60/50Hz 60Hz/50Hz 1 Phase 3 Phase IEC 34-1 turn
(MODEL)
Kg-m 90。 mm 1 Phase 3 Phase 110V 220V 380V 440V S4(%) N Kg
HQ-008 8 13/16 20 106/103 N/A 1.00/0.97 0.45/0.45 N/A N/A 70 10 7.4
HQ-010 10 16/20 20 106/103 N/A 1.00/0.97 0.47/0.45 N/A N/A 70 10 7.4
HQ-015 15 21/25 22 185/166 112/216 1.70/1.50 0.84/0.73 0.28/0.37 0.36/0.59 70 11 16.6
HQ-020 20 21/25 22 185/166 112/216 1.70/1.50 0.84/0.73 0.28/0.37 0.36/0.59 70 11 16.6
HQ-030 30 26/31 35 177/148 130/171 1.67/1.37 0.81/0.68 0.27/0.33 0.34/0.55 70 13.5 22 (Standard cam) (Cam block) (D-Type cam)
HQ-050 50 26/31 35 390/410 184/236 3.56/4.27 1.30/1.40 0.42/0.51 0.47/0.66 70 13.5 23
HQ-060 60 26/31 35 390/410 184/236 3.56/4.27 1.30/1.40 0.42/0.51 0.47/0.66 13.5 23 - 2 travel limit switches for operation
70
HQ-080 80 31/37 45 483/389 312/427 4.93/3.59 2.20/1.80 0.61/0.83 0.67/1.10 70 16.5 29 - 2 auxiliary limit switches as dry contact for customer usage
HQ-120 120 31/37 45 483/389 312/427 4.93/3.59 2.20/1.80 0.61/0.83 0.67/1.10 70 16.5 29 - Easy setting from upside by two screws for tight lockup
HQ-200 200 93/112 65 483/389 312/427 4.93/3.59 2.20/1.80 0.61/0.83 0.67/1.10 70 49.5 75 - Each cam be set independently
HQ-300 300 93/112 65 483/389 312/427 4.93/3.59 2.20/1.80 0.61/0.83 0.67/1.10 70 49.5 75
Standard Specification
Enclosure Weatherproof enclosure IP67, NEMA 4 and 6
Power supply 110 / 220V AC 1PH, 380 / 440V AC 3PH 50 / 60Hz, 10%
Control power supply 110 / 220V AC 1PH, 50 / 60Hz, 10%
Duty cycle(on-off) S2, 100% Max 30Min
Duty cycle(modulating) S4, 70% Max 300~1600 start/hour
Motor Induction motor (Reversibe motor)
Limit switches Open / close, SPDT, 250V AC 16A rating Proportional Control Unit (PCU) Potentiometer Kit (PIU)
Additional limit switches Open / close, SPDT, 250V AC 16A rating (except HQ-008/010) - Input signal range : 0~10VDC, 1~5VDC, 4~20mA, 20~4mA - 0~1K ohm( 0.5%), high resolution
Torque switches Open / close, SPDT, 250V AC 16A rating (except HQ-008/010) - Output signal range : 4~20mA, 0~10VDC
Stall protection/operating temp Built-in thermal protection, open 150℃ 5℃� / close 97℃ 15℃ - Adjustable range : Zero 8mA, Open 16mA
Travel angle 90Ņ 10Ņ (0 ~110Ņ) - Position conversion accuracy :
Indicator Continuous position indicator
0.5~1.5%(depends on installation)
Manual override Declutching mechanism
Self locking Provided by double worm gearing
Mechanical stopper 2 š external adjustable screws
Space heater 10W(110/220V AC) Anti-condensation
Cable entries Three PF3/4 tap (standard type only)
Lubrication Grease moly (EP type)
Terminal block Spring loaded lever push type
Materials Steel, Aluminium alloy, AI bronze, Polycarbonate
Ambient temperature -20 ~+70 (except option electronic board)
Ambient humidity 90% RH Max.(non-condensing)
Anti vibration X Y Z 10g, 0.2~34Hz, 30minute
External coating Anodizing treatment before dry powder, Polyester Fire Proofing Actuator (FPA) Rechargeable Battery Backup
8 9
HQ20P카탈로그
2009.4.17
7:33
PM페이지10
HQ200, HQ300
Dimension XQLWPP
%DVH,62 @ '
0RGHO ( ) * + , - . / 0 1 2 3 4 5 6 ; < =
& A PD[
) 0
+4
) 0
+4
)) 00
+4
)) 00
+4
)) 00
+4
)) 00
+4
)) 00
+4
)) 00
+4
)) 00
+4
)
) 0
0
+4
)
) 0
0
+4
White ˩Power
Blue ˩Remote
Yellow ˩Fault
Red ˩Open/
Opening
Green ˩Close/
Closing
12 13
HQ20P카탈로그
2009.4.17
7:33
PM페이지14
%DVH,62 $
0RGHO ' ( ) * + , - . / 0 1 2 3 4 5 6 : ; < =
&پ % PD[
)) 00
+4
پپ
)) 00
+4
پپ
)) 00
+4
پ پ
)) 00
+4
پ پ
)) 00
+4
پ پ
)) 00
+4
پ پ
)) 00
+4
پ پ
14 15
HQ20P카탈로그
2009.4.17
7:33
PM페이지16
LCU-C : Digital Display Control Electric Actuator Order Coding System (EXA : EEx d B T4)
- Light, Compact & Integrated design
- Wide range of electric power application
(AC 220V~AC460V/3-phase, No Fuse Break Max.AC600V/5A) HQ - XXX X X X X X X X
- Built-in auto phase discriminator (Easy & convenient wiring)
- Digital indicator with number, bar graph & literature
- Seperate terminal chamber
(Reliable against water, vibration, temp, etc)
- Easy application for HQ-series actuators
- Various option available
OPTION 5
SIZE 0 : N/A
1 : FPA 1
008 : 80Nm OPTION 4
010 : 100Nm 2 : FPA 2
015 : 150Nm 0 : N/A
ENCLOSURE
020 : 200Nm 1 : SLU
030 : 300Nm 1 : Weather proof (IP67) OPTION 3
2 : LPA
050 : 500Nm 2 : Submersible (IP68) 0 : N/A 3 : SLU+LPA
060 : 600Nm 3 : EX type
LCU-C Wiring (3-phase, 50/60Hz, proportional type) 080 : 800Nm
OPTION 1 OPTION 2 1 : 2ALS
2 : 2ATS
0 : N/A 0 : N/A
120 : 1200Nm
1 : LCU-C 1 : PIU
200 : 2000Nm MOTOR VOLTAGE
2 : LCU-B 2 : CPT *1
300 : 3000Nm
3 : RBP 1 : 110V AC / 1Ph 3 : PCU *1
2 : 220V AC / 1Ph
3 : 220V AC / 3Ph *1
4 : 380V AC / 3Ph *1
5 : 440V AC / 3Ph *1
6 : 460V AC / 3Ph *1
7 : 24V AC / DC *2
8 : 24V DC *2
Remarks)
- Asterisk*1 : HQ-008 through 010 actuators shall not be applied to the above condition.
- Asterisk*2 : HQ-050 through 300 actuators shall not be applied to the above condition.
- 2ATS/2ALS shall not be available for HQ-008 and for HQ-015 through 020 actuators with PCU.
- When LCU-B option applied, HQ-015 through 300 actuators shall be available on the full condition of motor
voltages except DC 24v.
- When LCU-C option applied, HQ-015 through 300 actuators shall be available on the condition of
220V through 460V 3 phase of voltages and shall not be available with PIU/CPT.
- Option RBP is available only for HQ-008/010, 015, 020, 030.
- More details should be advised to the manufacturer.
16 17
HQ20P카탈로그
2009.4.17
7:35
PM페이지18
Option Configuration
Proportional Control Unit (PCU) AC-DC 24V Control Unit
18 19