Technical Bulletin

Model: MET-C1d

PAGE: 1/1

Date: 17-Feb-14

No.: RD149064

Subject: Trouble shooting: Horizontal banding (rainbow image) Prepared by: M.Kumagai
From: 1st Tech Service Sect., MFP/P Tech Service Dept.
Classification:

Troubleshooting

Part information

Action required

Mechanical

Electrical

Service manual revision

Paper path

Transmit/receive

Retrofit information

Product Safety

Other ()

Tier 2

SYMPTOM
Horizontal banding (rainbow image) may occur at random pitch when printing out at 600dpi
or 1200dpi with 4C gradation.

CAUSE
Slight vibrations are transmitted to the image transfer area, which are then visible as
banding.

SOLUTION
This can be improved by changing the rotational speed of the OPC from -0.2% to -2.8%,
as described below.
1. SP1-801-133: Change from -20 to -280.
2. SP2-111-004: Execute