1.
Status of the Commissioning of the LIGHT Prototype / Degiovanni, Alberto (Unlisted, CH) ; Adam, Joel (Unlisted, CH) ; Aguilera Murciano, Debora (Unlisted, CH) ; Ballestrero, Sergio (Unlisted, CH) ; Benot-Morell, Alfonso (Unlisted, CH) ; Bonomi, Rossana (Unlisted, CH) ; Cabaleiro Magallanes, Francisco (Unlisted, CH) ; Caldara, Michele (Unlisted, CH) ; Cerv, Matevz (Unlisted, CH) ; D'Auria, Gerardo (Unlisted, CH ; Sincrotrone Trieste) et al.
The company A.D.A.M. (Application of Detectors and Accelerators to Medicine), a CERN spin-off, is working on the construction and testing of its first linear accelerator for medical application: LIGHT (Linac for Image-Guided Hadron Therapy). [...]
2018 - 4 p. - Published in : 10.18429/JACoW-IPAC2018-MOPML014 Fulltext: PDF;
In : 9th International Particle Accelerator Conference, Vancouver, Canada, 29 Apr - 4 May 2018, pp.MOPML014
2.
Simulations and Measurements of the CCL Modules of the LIGHT Accelerator / Khan, Vasim (Unlisted, CH) ; De Michele, Giovanni (Unlisted, CH) ; Esposito, Marco (Unlisted, CH) ; Fanella, Stefano (Unlisted, CH) ; Gibson, Stephen (Unlisted, CH) ; Gradassi, Paolo (Unlisted, CH) ; Ivanisenko, Yevgeniy (Unlisted, CH) ; Mellace, Claudio (Unlisted, CH) ; Navarro Quirante, Jose Luis (Unlisted, CH) ; Zannini, Carlo (Unlisted, CH)
A 230 MeV proton LINAC system for medical applications is being developed and commissioned for the LIGHT (Linac Image Guided Hadron Therapy) project by AVO-ADAM. The LINAC system consists of a 750 MHz RFQ (Radio frequency quadrupole) for the low energy proton acceleration, 2998 MHz SCDTL (Side Coupled Drift Tube Linacs) for the medium energy and 2998 MHz CCL (Coupled Cavity Linacs) for the high energy. [...]
2018 - 3 p. - Published in : 10.18429/JACoW-IPAC2018-MOPML015 Fulltext: PDF;
In : 9th International Particle Accelerator Conference, Vancouver, Canada, 29 Apr - 4 May 2018, pp.MOPML015
3.
Beam Commissioning of the 750 MHz Proton RFQ for the LIGHT Prototype / Dimov, Veliko (Unlisted, CH) ; Caldara, Michele (Unlisted, CH) ; Degiovanni, Alberto (Unlisted, CH) ; Esposito, Luigi Salvatore (Unlisted, CH) ; Fink, Daniel (Unlisted, CH) ; Giunta, Marina (Unlisted, CH) ; Jeff, Adam (Unlisted, CH) ; Lombardi, Alessandra (CERN) ; Mathot, Serge (CERN) ; Valloni, Alessandra (Unlisted, CH) et al.
ADAM (Application of Detectors and Accelerators to Medicine), a CERN spin-off company, is developing the Linac for Image Guided Hadron Therapy, LIGHT, which will accelerate proton beams up to 230 MeV. The design of the linac will allow fast intensity and energy modulation for pencil-beam scanning during cancer treatment. [...]
2018 - 3 p. - Published in : 10.18429/JACoW-IPAC2018-TUPAF002 Fulltext: PDF;
In : 9th International Particle Accelerator Conference, Vancouver, Canada, 29 Apr - 4 May 2018, pp.TUPAF002
4.
Linac Design within HITRIplus for Particle Therapy / Ratzinger, Ulrich (Unlisted, DE) ; Höltermann, Holger (Unlisted, DE) ; Koubek, Benjamin (Unlisted, DE) ; Podlech, Holger (Unlisted, DE) ; Vretenar, Maurizio (CERN)
Within the EU Horizon 2020 programme a linac was designed, which is starting from the concept as used at the 4 European cancer therapy centers applying light ions up to carbon. The new linac will in its simpliest version allow ion beam injection into synchrotrons at 5 A MeV, with high beam transmission and allowing currents up to 5 mA 𝛼 - particles. [...]
2022 - 4 p. - Published in : JACoW LINAC 2022 (2022) 134-137 Fulltext: PDF;
In : 31st Linear Accelerator Conference (LINAC22), Liverpool, UK, 28 Aug - 2 Sep 2022, pp.134-137
5.
Emittance reconstruction techniques in presence of space charge applied during the Linac4 beam commissioning / Dimov, Veliko (CERN) ; Gaur, Rahul (Raja Ramanna Ctr.) ; Lallement, Jean-Baptiste (CERN) ; Lombardi, Alessandra (CERN)
The classical emittance reconstruction technique, based on analytic calculations using transfer matrices and beam profile measurements, is reliable only if the emittance is conserved and the space charge forces are negligible in the beamline between the reconstruction and measurement points. The effects of space charge forces prevent this method from giving sound results up to a relativistic beta of about 0.5 and make it inapplicable to the Linac4 commissioning at 50 and 100 MeV. [...]
2016 - 6 p. - Published in : 10.18429/JACoW-HB2016-WEPM1Y01 Fulltext: PDF;
In : 57th ICFA Advanced Beam Dynamics Workshop on High-Intensity and High-Brightness Hadron Beams, Malmö, Sweden, 3 - 8 Jul 2016, pp.WEPM1Y01
6.
High-frequency compact RFQs for medical and industrial applications / Vretenar, Maurizio (CERN) ; Dimov, Veliko (CERN) ; Garlaschè, Marco (CERN) ; Grudiev, Alexej (CERN) ; Koubek, Benjamin (CERN) ; Lombardi, Alessandra (CERN) ; Mathot, Serge (CERN) ; Mazur, David (CERN) ; Montesinos, Eric (CERN) ; Timmins, Marc (CERN)
CERN has completed the construction of a 750 MHz RFQ reaching 5 MeV proton energy in a length of only 2 meters, to be used as injector for a compact proton therapy linac. Beyond proton therapy, this compact and lightweight design can be used for several applications, ranging from the production of radioisotopes in hospitals to ion beam analysis of industrial components or of artworks. [...]
CERN-ACC-2017-350.- 2017 - 6 p. - Published in : 10.18429/JACoW-LINAC2016-TH1A06 Fulltext: PDF;
In : 28th Linear Accelerator Conference, East Lansing, Michigan, 25 - 30 Sep 2016, pp.TH1A06
7.
Testing of the ESS MB-IOT Prototypes / Jensen, Morten (ESS, Lund) ; Bel, Claude (Thales Electron Devices, Velizy) ; Beunas, Armel (Thales Electron Devices, Velizy) ; Boyle, Michael (Unlisted, US) ; Bussiere, Denis (Thales Electron Devices, Velizy) ; Cacheux, Philippe (Thales Electron Devices, Velizy) ; Cipolla, Gino (CERN) ; Hermann, Virgile (Thales Electron Devices, Velizy) ; Kimura, Takuji (CPI, Palo Alto) ; Kirshner, Mark (Los Alamos) et al.
ESS is considering the use of MB-IOTs for parts of the high-beta linac. Two prototypes have been built by indus-try, namely L3 and CPI/Thales and have passed the factory acceptance test with excellent results. [...]
2018 - 6 p. - Published in : 10.18429/JACoW-IPAC2018-WEXGBF1 Fulltext: PDF;
In : 9th International Particle Accelerator Conference, Vancouver, Canada, 29 Apr - 4 May 2018, pp.WEXGBF1
8.
Control and Interlock Systems for the LIGHT Prototype / Moser, Roland ; Cerv, Matevz ; Magnoni, Stefano ; Pavetits, Hannes ; Paz Neira, Pablo ; Stachyra, Katarzyna
LIGHT (Linac Image Guided Hadron Technology) is a particle therapy system* developed by Advanced Oncotherapy plc. Accelerator, control and interlock systems are developed by its subsidiary A.D.A.M.SA, a CERN spin-off [...]
2018 - 5 p. - Published in : 10.18429/JACoW-ICALEPCS2017-THPHA130 Fulltext: PDF;
In : International Conference on Accelerator and Large Experimental Physics Control Systems, Barcelona, Spain, 8 - 13 Oct 2017, pp.THPHA130
9.
Beam Dynamics in a High Frequency RFQ / Lombardi, Alessandra (CERN) ; Dimov, Veliko (CERN) ; Garlaschè, Marco (CERN) ; Grudiev, Alexej (CERN) ; Mathot, Serge (CERN) ; Montesinos, Eric (CERN) ; Myers, Stephen (CERN) ; Timmins, Marc (CERN) ; Vretenar, Maurizio (CERN)
CERN is constructing a 750 MHz Radio Frequency Quadrupole (RFQ) which can accelerate a proton beam to 5 MeV in a length of 2 m. The beam dynamics strategic parameters have been chosen to make this RFQ a good candidate for the injector of a medical facility operating at frequency of 3 GHz. [...]
CERN-ACC-2015-260.- 2015 - 5 p. - Published in : (2015) , pp. WEYB2 Published version from JACoW: PDF; External link: JACOW
In : 6th International Particle Accelerator Conference, Richmond, VA, USA, 3 - 8 May 2015, pp.WEYB2
10.
Beam Commissioning of Linac4 up to 12 MeV / Dimov, Veliko (CERN) ; Belli, Eleonora (CERN) ; Bellodi, Giulia (CERN) ; Lallement, Jean-Baptiste (CERN) ; Lombardi, Alessandra (CERN) ; Yarmohammadi Satri, Masoomeh (IPM, Tehran)
CERN Linac4 is made of a 3 MeV front end including a 45 keV source , a 3 MeV Radio Frequency Quadrupole (RFQ) and a fast chopper, followed by a 50 MeV Drift Tube Linac (DTL), a 100 MeV Cell-Coupled Drift Tube Linac (CCDTL) and a 160 MeV Pi-Mode Structure (PIMS). The Linac4 beam commissioning is performed in 6 stages of increasing energy. [...]
CERN-ACC-2015-016.- 2015 - 4 p. - Published in : (2015) , pp. THPF085 Published version from JACoW: PDF; External link: JACOW
In : 6th International Particle Accelerator Conference, Richmond, VA, USA, 3 - 8 May 2015, pp.THPF085

Haven't found what you were looking for? Try your search on other servers:
recid:2665490 em Amazon
recid:2665490 em CERN EDMS
recid:2665490 em CERN Intranet
recid:2665490 em CiteSeer
recid:2665490 em Google Books
recid:2665490 em Google Scholar
recid:2665490 em Google Web
recid:2665490 em IEC
recid:2665490 em IHS
recid:2665490 em INSPIRE
recid:2665490 em ISO
recid:2665490 em KISS Books/Journals
recid:2665490 em KISS Preprints
recid:2665490 em NEBIS
recid:2665490 em SLAC Library Catalog