Comandos Baseband PDF
Comandos Baseband PDF
Comandos Baseband PDF
✓s+
Ativar atributes
✓prox
- Exibir os proxys
✓lt all
- Carregar os MO´s
✓cvms
✓cvls
- Lista cv
✓cvget
✓cvset
✓cvre
✓cvrm
✓alt
- Exibir alarmes
✓cabx
✓get 0
✓get . Associated
✓get . autoneg
✓get S freqBand
- Verificar a banda das RRU´s ou RU´s. B1-2100 / B5-850 / B7-2600 / B3-1800 / B8-900 / B28-
700
✓get . vlan
✓hget Equipment=1,FieldReplaceableUnit=1,AlarmPort=.$
administrativeState|alarmslogan|normallyOpen|perceived
- Exibe alarmes externos criados. Para mostrar em linhas, digitar get alarmPort=
✓Invxg
✓lh ru fui get vswr / lh ru fui get vswr 2 (RRUS32 e Rádios 4414 tem Branchs 3 e 4)
✓get . electricalAntennaTilt
- Restartar a baseband
✓ get transport=1,ethernet
✓ lbl transport=1,ethernet=TN_C
AUTONEGOCIAÇÃO
✓ ldeb transport=1,ethernet=TN_C
cab ! verifica o tipo de DUS, se for 3201, 5201 (Bb5212 ou Bb516) é uma Base Band!
Node: RadioNode L CXP9024418/6_R5G42 (17Q1.5)
================================================================================================
======================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL DATE TEMP
================================================================================================
======================
1 000100 DUS3201 1 OFF ON OFF OFF KDU137925/41 R5A D16V805838 20170214 (Bb5212)
RRU-1 BXP_0 RRUS2217B7 1 OFF ON OFF N/A KRC161428/1 R2B CA73213961 20170303 (Radio2217B7)
RRU-2 BXP_1 RRUS2217B7 1 OFF ON OFF N/A KRC161428/1 R2B CA73213987 20170303 (Radio2217B7)
RRU-3 BXP_2 RRUS2217B7 1 OFF ON OFF N/A KRC161428/1 R2B CA73213970 20170303 (Radio2217B7)
SUP-1 Z??_01 SUP6601 1 OFF ON N/A N/A 1/BFL901009/4 R2E BR84959994 20160818
------------------------------------------------------------------------------------------------
----------------------
================================================================================================
======================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
================================================================================================
======================
RBS6601 20/BFL901009/777 R1A B090225957 20170327 999 Cabinet=RBS6601
FANGROUP OFF Cabinet=RBS6601,FanGroup=1
------------------------------------------------------------------------------------------------
----------------------
invxr ! verifica o tipo de DUS, temperatura (DUS e RRU), VSWR, modelos e número de série do
Hardware!
================================================================================================
======================
FRU LNH BOARD ST FAULT OPER MAINT STAT PRODUCTNUMBER REV SERIAL DATE TEMP
================================================================================================
======================
1 000100 DUS3201 1 OFF ON OFF OFF KDU137925/41 R5A D16V805838 20170214 (Bb5212)
RRU-1 BXP_0 RRUS2217B7 1 OFF ON OFF N/A KRC161428/1 R2B CA73213961 20170303 48.4 (Radio2217B7)
RRU-2 BXP_1 RRUS2217B7 1 OFF ON OFF N/A KRC161428/1 R2B CA73213987 20170303 44.0 (Radio2217B7)
RRU-3 BXP_2 RRUS2217B7 1 OFF ON OFF N/A KRC161428/1 R2B CA73213970 20170303 42.8 (Radio2217B7)
SUP-1 Z??_01 SUP6601 1 OFF ON N/A N/A 1/BFL901009/4 R2E BR84959994 20160818
------------------------------------------------------------------------------------------------
----------------------
================================================================================================
======================
XPBOARD ST FAULT OPER PRODUCTNUMBER REV SERIAL/NAME DATE TEMP MO
================================================================================================
======================
RBS6601 20/BFL901009/777 R1A B090225957 20170327 999 Cabinet=RBS6601
FANGROUP OFF Cabinet=RBS6601,FanGroup=1
------------------------------------------------------------------------------------------------
----------------------
================================================================================================
======================
ID T RiL BOARD1 LNH1 PORT R LINK RATE BOARD2 LNH2 PORT R LINK RATE DELAY MO1 - MO2
================================================================================================
======================
1 O 1 DUS3201 000100 1 M Up 2.5G RRUS2217B7 BXP_0 0 S Up 2.5G 127m Fru=1(A) Fru=RRU-1(D1)
2 O 2 DUS3201 000100 2 M Up 2.5G RRUS2217B7 BXP_1 0 S Up 2.5G 127m Fru=1(B) Fru=RRU-2(D1)
3 O 3 DUS3201 000100 3 M Up 2.5G RRUS2217B7 BXP_2 0 S Up 2.5G 127m Fru=1(C) Fru=RRU-3(D1)
------------------------------------------------------------------------------------------------
----------------------
================================================================================================
======================
ID LINK RiL VENDOR1 VENDORPROD1 REV1 SERIAL1 DATE1 ERICSSONPROD1 VENDOR2 VENDORPROD2 REV2
SERIAL2
DATE2 ERICSSONPROD2
================================================================================================
======================
1 Up 1 DELTA LCP-2488B4HDRME1 A 1701061A0114005 20170104 RDH10247/2 R2A DELTA LCP-2488B4HDRME1 A
1701061A0113987 20170104 RDH10247/2 R2A
2 Up 2 DELTA LCP-2488B4HDRME1 A 1701061A0114012 20170104 RDH10247/2 R2A DELTA LCP-2488B4HDRME1 A
1701061A0114006 20170104 RDH10247/2 R2A
3 Up 3 DELTA LCP-2488B4HDRME1 A 1701061A0114008 20170104 RDH10247/2 R2A DELTA LCP-2488B4HDRME1 A
1701061A0114009 20170104 RDH10247/2 R2A
------------------------------------------------------------------------------------------------
----------------------
================================================================================================
======================
ID LINK RiL WL1 TEMP1 TXbs1 TXdBm1 RXdBm1 BER1 WL2 TEMP2 TXbs2 TXdBm2 RXdBm2 BER2 DlLoss UlLoss
================================================================================================
======================
1 Up 1 1310 58C 32% -5.47 -5.65 1310 43C 24% -5.53 -6.59 1.12 0.12
2 Up 2 1310 57C 28% -5.45 -6.82 1310 42C 24% -5.40 -5.38 -0.07 1.42
3 Up 3 1310 58C 34% -5.50 -5.14 1310 42C 26% -5.25 -4.90 -0.6 -0.11
------------------------------------------------------------------------------------------------
----------------------
ID RiL BOARD SFPLNH PORT VENDOR VENDORPROD REV SERIAL DATE ERICSSONPROD WL TEMP TXbs
TXdBm RXdBm BER
================================================================================================
======================
1 1 DUS3201 000100 1 DELTA LCP-2488B4HDRME1 A 1701061A0114005 20170104 RDH10247/2 R2A 1310 58C
32% -
5.47 -5.65
2 2 DUS3201 000100 2 DELTA LCP-2488B4HDRME1 A 1701061A0114012 20170104 RDH10247/2 R2A 1310 57C
28% -
5.45 -6.82
3 3 DUS3201 000100 3 DELTA LCP-2488B4HDRME1 A 1701061A0114008 20170104 RDH10247/2 R2A 1310 58C
34% -
5.50 -5.14
1 1 RRUS2217B7 BXP_0 0 DELTA LCP-2488B4HDRME1 A 1701061A0113987 20170104 RDH10247/2 R2A 1310 43C
24% -
5.53 -6.59
2 2 RRUS2217B7 BXP_1 0 DELTA LCP-2488B4HDRME1 A 1701061A0114006 20170104 RDH10247/2 R2A 1310 42C
24% -
5.40 -5.38
3 3 RRUS2217B7 BXP_2 0 DELTA LCP-2488B4HDRME1 A 1701061A0114009 20170104 RDH10247/2 R2A 1310 42C
26% -
5.25 -4.90
------------------------------------------------------------------------------------------------
----------------------
TN DUS3201 000100 B WTD RTXM192-406-C25 3.0 EC164000300741 160930 RDH10247/2 R2A 1310 52C 21% -
5.73 -4.92
================================================================================================
======================
FRU LNH BOARD RF TX (W/dBm) VSWR (RL) Sector/Cells (localCellIds/CellIds,PCIs)
================================================================================================
======================
RRU-1 BXP_0 RRUS2217B7 A 10.8 (40.3) 1.14 (23.5) SE=1 FDD=TMVN11 (1:164)
RRU-1 BXP_0 RRUS2217B7 B 10.8 (40.3) 1.13 (24.3) SE=1 FDD=TMVN11 (1:164)
RRU-2 BXP_1 RRUS2217B7 A 7.0 (38.5) 1.30 (17.7) SE=2 FDD=TMVN12 (2:172)
RRU-2 BXP_1 RRUS2217B7 B 7.0 (38.5) 1.20 (20.7) SE=2 FDD=TMVN12 (2:172)
RRU-3 BXP_2 RRUS2217B7 A 7.3 (38.6) 1.14 (23.8) SE=3 FDD=TMVN13 (3:180)
RRU-3 BXP_2 RRUS2217B7 B 7.3 (38.6) 1.13 (24.2) SE=3 FDD=TMVN13 (3:180)
invg ! verifica as Features, Softwares, Licenças e um Bay Face da ligação da DU com RRU!
============================================================================
LicenseState: NORMAL
FingerPrint: TMVN1_SP
InstallationTime: 2017-06-08 17:54:49
SequenceNumber: 1013
AutonomousMode: INACTIVE
EmergencyUnlock: INACTIVE
IntegrationUnlock: INACTIVE
----------------------------------------------------------------------------
================================================================================================
======================
FeatureName FeatureKey FAJ LicenseState FeatureState ServiceState ValidFrom
ValidUntil Description
================================================================================================
======================
IpSec CXC4040004 FAJ1213586 1 (ENABLED) 1 (ACTIVATED) 1 (OPERABLE) 2017-06-07
NULL IPSec
================================================================================================
======================
CapacityName CapacityKey FAJ LicenseState ValidFrom ValidUntil currLimit grantedLevel
limitReached Description (Unit)
================================================================================================
======================
5MHzSectorCarriers CXC4011622 FAJ1213071 1 (ENABLED) 2017-06-07 NULL noLimit -1
false Capacity 5MHz Sector Carriers (Nr of 5MHz Sector Carriers)
============================================================================
SwItems for BASEBAND CXP9024418/6 R5G42 2017-05-06T14:48:06
----------------------------------------------------------------------------
3PPOSSASN1-ARM CXP9024079/3 R1AD 2016-10-14T12:37:51
.
+---------+ +------------+
| | A O25 D1 | RRU-1 |
| |----1/1----| RRUS2217B7 |
| | 127m | BXP_0 |
| | +------------+
| | |A |B
| | SE=1 FDD=TMVN11
| |
| | +------------+
| | B O25 D1 | RRU-2 |
| 1 |----2/2----| RRUS2217B7 |
| DUS3201 | 127m | BXP_1 |
| 000100 | +------------+
| | |A |B
| | SE=2 FDD=TMVN12
| |
| | +------------+
| | C O25 D1 | RRU-3 |
| |----3/3----| RRUS2217B7 |
| | 127m | BXP_2 |
| | +------------+
| | |A |B
+---------+ SE=3 FDD=TMVN13
lga – m 10 !verifica o log de alarmes dos últimos 10 dias, se pedir senha é a senha do usuário
do OSS!
7.0 – Comandos para verificar porta de TX, IP do site, IP do Gateway, e teste de PING
se executarmos o script do TCU no TCU, mas a porta de dados do BB5216 não for aberta
(porta entre BB5216
(e TCU
o primeiro pensamento sobre o problema é substituir a conexão de fibra entre o TCU e o
BB5216
mas o problema pode não estar no cabo e pode estar na configuração
(pode ser a porta de dados do BB5216 (TNB
ainda não aberto
Se o estado Admin estiver bloqueado e o estado Operacional estiver desativado, a porta TNB
estará fechada
sabemos que
T=2600
P=2600
V=1800
Z=700
PARA BLOQUEAR:
PARA DESBLOQUEAR:
get . configuredMaxTxPower
*ALTERAR POTENCIA*
1º BLOQUEAR AS RRUS
bl rru
2º BLOQUEAR AS CELULA
bl fdd
1º DESBLOQUEAR AS RRUS
deb rru
2º DESBLOQUEAR AS CELULA
deb fdd
VERIFICAR POTENCIAS
get . configuredMaxTxPower
* S+
* Prox
* get . auton
* get __
Depois salvar o cv
* cvls
* cvms change_AutoNegotiation
* lpr ipv4