Khalili et al., 2019 - Google Patents
Impact of Fans Location on the Cooling Efficiency of IT ServersKhalili et al., 2019
View PDF- Document ID
- 17319062424100668687
- Author
- Khalili S
- Tradat M
- Sammakia B
- Alissa H
- Chen C
- Publication year
- Publication venue
- 2019 18th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)
External Links
Snippet
The role of data centers in modern life has expanded rapidly over the past decades. In addition, this expansion has resulted in a significant increase in the share of data centers in total energy consumption of the world. Thus, reliability and energy efficiency have become a …
- 238000001816 cooling 0 title abstract description 37
Classifications
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/16—Constructional details or arrangements
- G06F1/20—Cooling means
- G06F1/206—Cooling means comprising thermal management
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/16—Constructional details or arrangements
- G06F1/20—Cooling means
- G06F1/203—Cooling means for portable computers, e.g. for laptops
-
- H—ELECTRICITY
- H05—ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
- H05K—PRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
- H05K7/00—Constructional details common to different types of electric apparatus
- H05K7/20—Modifications to facilitate cooling, ventilating, or heating
- H05K7/20709—Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
- H05K7/20718—Forced ventilation of a gaseous coolant
- H05K7/20745—Forced ventilation of a gaseous coolant within rooms for removing heat from cabinets, e.g. by air conditioning device
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/16—Constructional details or arrangements
- G06F1/18—Packaging or power distribution
-
- H—ELECTRICITY
- H05—ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
- H05K—PRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
- H05K7/00—Constructional details common to different types of electric apparatus
- H05K7/20—Modifications to facilitate cooling, ventilating, or heating
- H05K7/20009—Modifications to facilitate cooling, ventilating, or heating using a gaseous coolant in electronic enclosures
- H05K7/20136—Forced ventilation, e.g. by fans
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F17/00—Digital computing or data processing equipment or methods, specially adapted for specific functions
- G06F17/50—Computer-aided design
- G06F17/5009—Computer-aided design using simulation
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F2217/00—Indexing scheme relating to computer aided design [CAD]
- G06F2217/78—Power analysis and optimization
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Alkharabsheh et al. | A brief overview of recent developments in thermal management in data centers | |
Chu et al. | A review on airflow management in data centers | |
Wan et al. | Air flow measurement and management for improving cooling and energy efficiency in raised-floor data centers: A survey | |
Jin et al. | Effects of airflow on the thermal environment and energy efficiency in raised-floor data centers: A review | |
Fulpagare et al. | Advances in data center thermal management | |
Meng et al. | Optimization of the thermal environment of a small-scale data center in China | |
Joshi et al. | Energy efficient thermal management of data centers | |
Tradat et al. | An experimental and numerical investigation of novel solution for energy management enhancement in data centers using underfloor plenum porous obstructions | |
Choo et al. | Energy consumption analysis of a medium-size primary data center in an academic campus | |
Cho et al. | Development of modular air containment system: Thermal performance optimization of row-based cooling for high-density data centers | |
Chu et al. | Experimental investigation on thermal management for small container data center | |
Kuzay et al. | Retrofitting of an air-cooled data center for energy efficiency | |
Gao et al. | Comparative analysis of different in row cooler management configurations in a hybrid cooling data center | |
Manaserh et al. | General guidelines for commercialization a small-scale in-row cooled data center: a case study | |
Cho et al. | Numerical and experimental study of air containment systems in legacy data centers focusing on thermal performance and air leakage | |
Zhou et al. | Numerical simulation on a thermal management system for a small data center | |
Modi et al. | Experimental Investigation of the Impact of Improved Ducting and Chassis Re-Design of a Hybrid-Cooled Server | |
Zhang et al. | Optimization on jet‐induced ventilation to enhance the uniformity of airflow distribution in data center | |
Fernandes | Minimizing Power Consumption At Module, Server And Rack-levels Within A Data Center Through Design And Energy-efficient Operation Of Dynamic Cooling Solutions | |
Joshi et al. | Introduction to data center energy flow and thermal management | |
Khalili et al. | Impact of Fans Location on the Cooling Efficiency of IT Servers | |
Khalili et al. | Impact of server thermal design on the cooling efficiency: Chassis design | |
Gao et al. | Dynamic analysis of hybrid cooling data centers subjects to the failure of CRAC units | |
Ahmad et al. | Navier-Stokes simulation of air-conditioning facility of a large modern computer room | |
Khalili et al. | Impact of Internal Design on the Efficiency of IT Equipment in a Hot Aisle Containment System: An Experimental Study |