Firouzjah et al., 2019 - Google Patents
A fast current harmonic detection and mitigation strategy for shunt active filterFirouzjah et al., 2019
- Document ID
- 16294545831154767524
- Author
- Firouzjah K
- Ahmadiahangar R
- Rosin A
- Häring T
- Publication year
- Publication venue
- 2019 Electric Power Quality and Supply Reliability Conference (PQ) & 2019 Symposium on Electrical Engineering and Mechatronics (SEEM)
External Links
Snippet
In this paper, a new strategy is presented for fast mitigation of system's harmonics using active shunt power filter. In the first section, the harmonic component of the load current is detected by applying the synchronous reference frame theory. The contribution of this …
- 230000000116 mitigating 0 title abstract description 4
Classifications
-
- H—ELECTRICITY
- H02—GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
- H02M—APPARATUS FOR CONVERSION BETWEEN AC AND AC, BETWEEN AC AND DC, OR BETWEEN DC AND DC, AND FOR USE WITH MAINS OR SIMILAR POWER SUPPLY SYSTEMS; CONVERSION OF DC OR AC INPUT POWER INTO SURGE OUTPUT POWER; CONTROL OR REGULATION THEREOF
- H02M7/00—Conversion of ac power input into dc power output; Conversion of dc power input into ac power output
- H02M7/42—Conversion of dc power input into ac power output without possibility of reversal
- H02M7/44—Conversion of dc power input into ac power output without possibility of reversal by static converters
- H02M7/48—Conversion of dc power input into ac power output without possibility of reversal by static converters using discharge tubes with control electrode or semiconductor devices with control electrode
- H02M7/53—Conversion of dc power input into ac power output without possibility of reversal by static converters using discharge tubes with control electrode or semiconductor devices with control electrode using devices of a triode or transistor type requiring continuous application of a control signal
- H02M7/537—Conversion of dc power input into ac power output without possibility of reversal by static converters using discharge tubes with control electrode or semiconductor devices with control electrode using devices of a triode or transistor type requiring continuous application of a control signal using semiconductor devices only, e.g. single switched pulse inverters
- H02M7/5387—Conversion of dc power input into ac power output without possibility of reversal by static converters using discharge tubes with control electrode or semiconductor devices with control electrode using devices of a triode or transistor type requiring continuous application of a control signal using semiconductor devices only, e.g. single switched pulse inverters in a bridge configuration
- H02M7/53871—Conversion of dc power input into ac power output without possibility of reversal by static converters using discharge tubes with control electrode or semiconductor devices with control electrode using devices of a triode or transistor type requiring continuous application of a control signal using semiconductor devices only, e.g. single switched pulse inverters in a bridge configuration with automatic control of output voltage or current
-
- H—ELECTRICITY
- H02—GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
- H02M—APPARATUS FOR CONVERSION BETWEEN AC AND AC, BETWEEN AC AND DC, OR BETWEEN DC AND DC, AND FOR USE WITH MAINS OR SIMILAR POWER SUPPLY SYSTEMS; CONVERSION OF DC OR AC INPUT POWER INTO SURGE OUTPUT POWER; CONTROL OR REGULATION THEREOF
- H02M7/00—Conversion of ac power input into dc power output; Conversion of dc power input into ac power output
- H02M7/02—Conversion of ac power input into dc power output without possibility of reversal
- H02M7/04—Conversion of ac power input into dc power output without possibility of reversal by static converters
- H02M7/12—Conversion of ac power input into dc power output without possibility of reversal by static converters using discharge tubes with control electrode or semiconductor devices with control electrode
- H02M7/21—Conversion of ac power input into dc power output without possibility of reversal by static converters using discharge tubes with control electrode or semiconductor devices with control electrode using devices of a triode or transistor type requiring continuous application of a control signal
-
- Y—GENERAL TAGGING OF NEW TECHNOLOGICAL DEVELOPMENTS; GENERAL TAGGING OF CROSS-SECTIONAL TECHNOLOGIES SPANNING OVER SEVERAL SECTIONS OF THE IPC; TECHNICAL SUBJECTS COVERED BY FORMER USPC CROSS-REFERENCE ART COLLECTIONS [XRACs] AND DIGESTS
- Y02—TECHNOLOGIES OR APPLICATIONS FOR MITIGATION OR ADAPTATION AGAINST CLIMATE CHANGE
- Y02E—REDUCTION OF GREENHOUSE GASES [GHG] EMISSION, RELATED TO ENERGY GENERATION, TRANSMISSION OR DISTRIBUTION
- Y02E40/00—Technologies for an efficient electrical power generation, transmission or distribution
- Y02E40/20—Active power filtering [APF]
-
- Y—GENERAL TAGGING OF NEW TECHNOLOGICAL DEVELOPMENTS; GENERAL TAGGING OF CROSS-SECTIONAL TECHNOLOGIES SPANNING OVER SEVERAL SECTIONS OF THE IPC; TECHNICAL SUBJECTS COVERED BY FORMER USPC CROSS-REFERENCE ART COLLECTIONS [XRACs] AND DIGESTS
- Y02—TECHNOLOGIES OR APPLICATIONS FOR MITIGATION OR ADAPTATION AGAINST CLIMATE CHANGE
- Y02E—REDUCTION OF GREENHOUSE GASES [GHG] EMISSION, RELATED TO ENERGY GENERATION, TRANSMISSION OR DISTRIBUTION
- Y02E10/00—Energy generation through renewable energy sources
- Y02E10/50—Photovoltaic [PV] energy
- Y02E10/56—Power conversion electric or electronic aspects
-
- Y—GENERAL TAGGING OF NEW TECHNOLOGICAL DEVELOPMENTS; GENERAL TAGGING OF CROSS-SECTIONAL TECHNOLOGIES SPANNING OVER SEVERAL SECTIONS OF THE IPC; TECHNICAL SUBJECTS COVERED BY FORMER USPC CROSS-REFERENCE ART COLLECTIONS [XRACs] AND DIGESTS
- Y02—TECHNOLOGIES OR APPLICATIONS FOR MITIGATION OR ADAPTATION AGAINST CLIMATE CHANGE
- Y02E—REDUCTION OF GREENHOUSE GASES [GHG] EMISSION, RELATED TO ENERGY GENERATION, TRANSMISSION OR DISTRIBUTION
- Y02E40/00—Technologies for an efficient electrical power generation, transmission or distribution
- Y02E40/40—Arrangements for reducing harmonics
-
- H—ELECTRICITY
- H02—GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
- H02M—APPARATUS FOR CONVERSION BETWEEN AC AND AC, BETWEEN AC AND DC, OR BETWEEN DC AND DC, AND FOR USE WITH MAINS OR SIMILAR POWER SUPPLY SYSTEMS; CONVERSION OF DC OR AC INPUT POWER INTO SURGE OUTPUT POWER; CONTROL OR REGULATION THEREOF
- H02M1/00—Details of apparatus for conversion
- H02M1/12—Arrangements for reducing harmonics from ac input or output
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Blaabjerg et al. | Comparison of two current modulation strategies for matrix converters under unbalanced input voltage conditions | |
Svensson et al. | Practical implementation of delayed signal cancellation method for phase-sequence separation | |
Li et al. | A novel time-domain current-detection algorithm for shunt active power filters | |
CN106501574B (en) | A kind of Active Power Filter Harmonic Currents detection method | |
CN108880297B (en) | Phase compensation device and method based on Vienna rectifier | |
CN103683319A (en) | Grid connected inverter control method based on hysteresis modulation under unbalanced grid voltage condition | |
Meral | Improved phase-locked loop for robust and fast tracking of three phases under unbalanced electric grid conditions | |
Galkin et al. | Optimizing of sampling in a low-cost single-phase instantaneous AC-grid synchronization unit with discrete calculation of derivative function | |
Sujitjorn et al. | The DQ axis with fourier (DQF) method for harmonic identification | |
Firouzjah et al. | A fast current harmonic detection and mitigation strategy for shunt active filter | |
Yue et al. | Robust predictive dual-loop control method based on Lyapunov function stability and energy equilibrium though double-core processors for active power filter | |
CN106483375B (en) | A kind of multi-frequency fractional harmonic wave detection method | |
Mohamad et al. | Adaptive notch filter under indirect and direct current controls for active power filter | |
Pigazo et al. | Accurate and computationally efficient implementation of the IEEE 1459-2000 standard in three-phase three-wire power systems | |
Nishida et al. | Digital control three-phase shunt active power filter with a new harmonic-current-extraction process | |
Inci et al. | Multipurpose compensation scheme for voltage sag/swell and selective harmonics elimination in distribution systems | |
Hosseinpour et al. | RDFT based control of a 3-phase 4-leg shunt active power filter under unbalanced load and non-ideal mains voltage conditions | |
Lin et al. | Shunt active filter with sliding mode control | |
Chatterjee et al. | Single-phase average power measurement using instantaneous power theory in a fixed point processor | |
Borisov et al. | A novel reference signal generator for active power filters based on recursive DFT | |
CN108899906B (en) | Built-in repetitive dead beat control method for three-phase four-wire APF | |
Han et al. | Dynamic optimization for shunt active power filter to selectively extract harmonics with Vector Discrete Fourier Transform | |
Wang et al. | A transient reactive current compensation for load-side converter of BDFG in stand-alone operation | |
Ray et al. | Noise Detection Based Adaptive Control of Dual Staged Grid Interfaced PV System | |
Kimura et al. | Real time symmetrical coordinate transformation applied for detection of imbalanced fault in utility power system |