Baglin et al., 1973 - Google Patents
2H (γ, p) absolute cross section and angular distribution at 17–25 MeVBaglin et al., 1973
- Document ID
- 16094236417083973812
- Author
- Baglin J
- Carr R
- Bentz Jr E
- Wu C
- Publication year
- Publication venue
- Nuclear Physics A
External Links
Snippet
The absolute differential cross section for the 2H (γ, p) n reaction has been determined for lab angles of 20°, 45°, 65°, 90°, 115°, 135° and 160°, through the excitation energy range from 17 to 25 MeV. The estimated experimental uncertainty in cross-section values is±6 …
- 238000009826 distribution 0 title description 11
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/02—Dosimeters
- G01T1/026—Semiconductor dose-rate meters
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/17—Circuit arrangements not adapted to a particular type of detector
- G01T1/178—Circuit arrangements not adapted to a particular type of detector for measuring specific activity in the presence of other radioactive substances, e.g. natural, in the air or in liquids such as rain water
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/02—Dosimeters
- G01T1/10—Luminescent dosimeters
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/29—Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
- G01T1/2914—Measurement of spatial distribution of radiation
- G01T1/2921—Static instruments for imaging the distribution of radioactivity in one or two dimensions; Radio-isotope cameras
- G01T1/2935—Static instruments for imaging the distribution of radioactivity in one or two dimensions; Radio-isotope cameras using ionisation detectors
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T3/00—Measuring neutron radiation
- G01T3/06—Measuring neutron radiation with scintillation detectors
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T7/00—Details of radiation-measuring instruments
- G01T7/02—Collecting means for receiving or storing samples to be investigated and possibly directly transporting the samples to the measuring arrangement; particularly for investigating radioactive fluids
-
- G—PHYSICS
- G21—NUCLEAR PHYSICS; NUCLEAR ENGINEERING
- G21K—TECHNIQUES FOR HANDLING PARTICLES OR IONISING RADIATION NOT OTHERWISE PROVIDED FOR; IRRADIATION DEVICES; GAMMA RAY OR X-RAY MICROSCOPES
- G21K1/00—Arrangements for handling particles or ionizing radiation, e.g. focusing or moderating
- G21K1/02—Arrangements for handling particles or ionizing radiation, e.g. focusing or moderating using diaphragms, collimators
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T5/00—Recording of movements or tracks of particles; Processing or analysis of such tracks
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Polf et al. | Measurement and calculation of characteristic prompt gamma ray spectra emitted during proton irradiation | |
Last et al. | Pulsed-beam neutron-lifetime measurement | |
Akhmadaliev et al. | Delbrück scattering at energies of 140–450 MeV | |
Baglin et al. | 2H (γ, p) absolute cross section and angular distribution at 17–25 MeV | |
Daum et al. | Precision measurement of the muon momentum in pion decay at rest | |
Gayther et al. | Neutron energy spectra and angular distributions from targets bombarded by 45 MeV electrons | |
Garwin | Gamma-Ray Excitation of the 15.1-Mev Level in C 12 | |
Cookson et al. | Scattering of 10 MeV neutrons by 6Li and 7Li | |
Warren | 35 Cl (n, p) reactions in a 6 Li enhanced CLYC detector | |
Hester et al. | Radiative Capture of Protons in C 13 | |
Moros et al. | Characterization and calibration of a triple-GEM detector for medical dosimetry | |
Hu et al. | Experimental determination of the response functions of a Bonner sphere spectrometer to monoenergetic neutrons | |
Heaton et al. | Total neutron cross section of carbon from 1 keV to 15 MeV | |
Romanowski et al. | Photoneutron Cross Sections of Li 6 and Li 7 | |
Prestwich et al. | Lithium target performance evaluation for low-energy accelerator-based in vivo measurements using gamma spectroscopy | |
Calviania et al. | Beam monitoring of high energy proton flux by the activation foil technique | |
Brackenbush et al. | Mixed field dose equivalent measuring instruments | |
Lindström et al. | A Precision Measurement of the 137Cs γ-Line | |
Maughan et al. | A measurement of the fast-neutron sensitivity of a Geiger-Müller detector in the pulsed neutron beam from a superconducting cyclotron | |
Eisen et al. | The performance of low pressure tissue-equivalent chambers and a new method for parameterising the dose equivalent | |
Edwards et al. | Comparison of fast neutron beams for radiotherapy produced by 17.3‐MeV deuterons incident on beryllium and deuterium targets | |
Moros | Characterization and Calibration of a Triple-GEM Detector for Medical Applications | |
Baker | Radiation interactions with matter | |
McCaslin et al. | An intercomparison of dosimetry techniques in radiation fields at two high-energy accelerators | |
Maruyama et al. | Spectra of Primary X-ray and Secondary Photons from Shielding Materials for 4–30 MV X-rays |