Syltøy, 2019 - Google Patents
Monte Carlo simulations of neutron based in-vivo range verification in proton therapy–optimization of detector dimensions and positioningSyltøy, 2019
View PDF- Document ID
- 1304473973662035916
- Author
- Syltøy J
- Publication year
External Links
Snippet
Proton therapy is a cancer treatment modality expanding in clinical applications around the world. Due to the finite range of a monoenergetic proton beam, it is possible to spare more of the healthy tissue surrounding the tumour compared with using traditional radiation therapy …
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1048—Monitoring, verifying, controlling systems and methods
- A61N5/1075—Monitoring, verifying, controlling systems and methods for testing, calibrating, or quality assurance of the radiation treatment apparatus
- A61N2005/1076—Monitoring, verifying, controlling systems and methods for testing, calibrating, or quality assurance of the radiation treatment apparatus using a dummy object placed in the radiation field, e.g. phantom
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/103—Treatment planning systems
- A61N5/1031—Treatment planning systems using a specific method of dose optimization
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1048—Monitoring, verifying, controlling systems and methods
- A61N5/1049—Monitoring, verifying, controlling systems and methods for verifying the position of the patient with respect to the radiation beam
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1042—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy with spatial modulation of the radiation beam within the treatment head
- A61N5/1043—Scanning the radiation beam, e.g. spot scanning or raster scanning
- A61N5/1044—Scanning the radiation beam, e.g. spot scanning or raster scanning with multiple repetitions of the scanning pattern
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N2005/1085—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy characterised by the type of particles applied to the patient
- A61N2005/1087—Ions; Protons
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N2005/1092—Details
- A61N2005/1095—Elements inserted into the radiation path within the system, e.g. filters or wedges
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1077—Beam delivery systems
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1001—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy using radiation sources introduced into or applied onto the body; brachytherapy
-
- G—PHYSICS
- G21—NUCLEAR PHYSICS; NUCLEAR ENGINEERING
- G21K—TECHNIQUES FOR HANDLING PARTICLES OR IONISING RADIATION NOT OTHERWISE PROVIDED FOR; IRRADIATION DEVICES; GAMMA RAY OR X-RAY MICROSCOPES
- G21K1/00—Arrangements for handling particles or ionizing radiation, e.g. focusing or moderating
- G21K1/02—Arrangements for handling particles or ionizing radiation, e.g. focusing or moderating using diaphragms, collimators
-
- G—PHYSICS
- G21—NUCLEAR PHYSICS; NUCLEAR ENGINEERING
- G21K—TECHNIQUES FOR HANDLING PARTICLES OR IONISING RADIATION NOT OTHERWISE PROVIDED FOR; IRRADIATION DEVICES; GAMMA RAY OR X-RAY MICROSCOPES
- G21K5/00—Irradiation devices
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Krimmer et al. | Prompt-gamma monitoring in hadrontherapy: A review | |
Kraan | Range verification methods in particle therapy: underlying physics and Monte Carlo modeling | |
Knopf et al. | In vivo proton range verification: a review | |
Pönisch et al. | The modelling of positron emitter production and PET imaging during carbon ion therapy | |
Parodi | On-and off-line monitoring of ion beam treatment | |
Richard et al. | Design guidelines for a double scattering compton camera for prompt-$\gamma $ imaging during ion beam therapy: a monte carlo simulation study | |
Polf et al. | Imaging particle beams for cancer treatment | |
La Tessa et al. | Characterization of the secondary neutron field produced during treatment of an anthropomorphic phantom with x-rays, protons and carbon ions | |
Battistoni et al. | Nuclear physics and particle therapy | |
Tilikidis et al. | An estimation of the relative biological effectiveness of 50 MV bremsstrahlung beams by microdosimetric techniques | |
Miyatake et al. | Development of activity pencil beam algorithm using measured distribution data of positron emitter nuclei generated by proton irradiation of targets containing 12C, 16O, and 40Ca nuclei in preparation of clinical application | |
Verburg | Reducing range uncertainty in proton therapy | |
Richard et al. | Design study of a Compton camera for prompt γ imaging during ion beam therapy | |
Syltøy | Monte Carlo simulations of neutron based in-vivo range verification in proton therapy–optimization of detector dimensions and positioning | |
Ng et al. | Problems and Solutions in Medical Physics: Radiotherapy Physics | |
Mirzakhanian | Reference dosimetry of static, nonstandard radiation therapy fields: application to biology-guided radiotherapy and cranial radiosurgery generators | |
Fathallah | Commissioning of 360° rotational single room ProBeam Compact™(Varian Medical) pencil beam scanning proton therapy system | |
Aricó | Ion spectroscopy for improvement of the physical beam model for therapy planning in ion beam therapy | |
Ganjaroodi et al. | Probability assessment of photoneutron production of Varian-Clinac ix linear accelerator using Monte Carlo simulation | |
Hanada et al. | Evaluation of the dosimetric parameters for 125I brachytherapy determined in prostate medium using CT images | |
Rivera et al. | Kinetic Energy of Secondary Particles Produced from Various Electromagnetic Interactions in Water: A Monte Carlo Study | |
Rovituso | Fragmentation and lateral scattering of 120 and 200 MeV/u 4He ions on water targets | |
Missaglia | Prompt gamma imaging with a slit camera for range monitoring in carbon ion radiation therapy: a Monte Carlo feasibility study | |
Saunders | Secondary prompt gamma rays to improve proton range verification | |
Al Makdessi | Secondary neutrons around clinical electron and proton beams |