Wang et al., 2020 - Google Patents
MRC-based double figure-of-eight coil sensor system with triple-mode operation capability for biomedical applicationsWang et al., 2020
- Document ID
- 1292683654331367209
- Author
- Wang W
- Pradhan R
- Ho Y
- Zhao Z
- Sun Q
- Liao X
- Wang S
- Fang Z
- Zheng Y
- Publication year
- Publication venue
- IEEE Sensors Journal
External Links
Snippet
Efficient wireless power transmission to a designated location can reduce the size of implantable device and save source energy, but the receiver coil and rectifier circuit still occupy a large area. This paper proposes a novel magnetic resonant coupling (MRC)-based …
- 230000000694 effects 0 abstract description 20
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N1/00—Electrotherapy; Circuits therefor
- A61N1/40—Applying electric fields by inductive or capacitive coupling ; Applying radio-frequency signals
- A61N1/403—Applying electric fields by inductive or capacitive coupling ; Applying radio-frequency signals for thermotherapy, e.g. hyperthermia
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N1/00—Electrotherapy; Circuits therefor
- A61N1/18—Applying electric currents by contact electrodes
- A61N1/32—Applying electric currents by contact electrodes alternating or intermittent currents
- A61N1/36—Applying electric currents by contact electrodes alternating or intermittent currents for stimulation, e.g. heart pace-makers
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N2/00—Magnetotherapy
- A61N2/02—Magnetotherapy using magnetic fields produced by coils, including single turn loops or electromagnets
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R33/00—Arrangements or instruments for measuring magnetic variables
- G01R33/20—Arrangements or instruments for measuring magnetic variables involving magnetic resonance
- G01R33/28—Details of apparatus provided for in groups G01R33/44 - G01R33/64
- G01R33/32—Excitation or detection systems, e.g. using radio frequency signals
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N1/00—Electrotherapy; Circuits therefor
- A61N1/02—Details
- A61N1/08—Arrangements or circuits for monitoring, protecting, controlling or indicating
- A61N2001/086—MRI compatible leads
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Wang et al. | MRC-based double figure-of-eight coil sensor system with triple-mode operation capability for biomedical applications | |
Campi et al. | Wireless power transfer charging system for AIMDs and pacemakers | |
Xiao et al. | Wireless charging system considering eddy current in cardiac pacemaker shell: Theoretical modeling, experiments, and safety simulations | |
Basar et al. | Stable and high-efficiency wireless power transfer system for robotic capsule using a modified Helmholtz coil | |
Christ et al. | Assessing human exposure to electromagnetic fields from wireless power transmission systems | |
Freeman et al. | Optimal frequency for wireless power transmission into the body: efficiency versus received power | |
US20110224479A1 (en) | Eddy current induced hyperthermia using conductive particles | |
Campi et al. | Innovative wireless charging system for implantable capsule robots | |
Ha-Van et al. | Modeling and experimental validation of a butterfly-shaped wireless power transfer in biomedical implants | |
Shao et al. | Hybrid wireless positioning and charging with switched field Helmholtz coils for wireless capsule endoscopy | |
Luo et al. | A design method of magnetically resonanting wireless power delivery systems for bio-implantable devices | |
Yang et al. | Numerical investigations of MRI RF-induced heating for external fixation device in TEM and birdcage body coils at 3 T | |
Yang et al. | Impact of electrode structure on RF-induced heating for an AIMD implanted lead in a 1.5-Tesla MRI system | |
WO2014133391A1 (en) | Dipole antenna for a magnetic resonance imaging system | |
Zhuang et al. | Ferrite concentrating and shielding structure design of wireless power transmitting coil for inductively coupled capsule robot | |
Shiba et al. | Energy transmission transformer for a wireless capsule endoscope: Analysis of specific absorption rate and current density in biological tissue | |
Bao et al. | Optimization of the coupling coefficient of the inductive link for wireless power transfer to biomedical implants | |
Li et al. | A new design and analysis for metasurface-based near-field magnetic wireless power transfer for deep implants | |
Jian et al. | A novel targeted magnetic fluid hyperthermia system using HTS coil array for tumor treatment | |
Basham et al. | Circuit and coil design for in-vitro magnetic neural stimulation systems | |
Yeung et al. | Focused magnetic resonance coupling coils for electromagnetic therapy applications | |
Tian et al. | Design and optimization of resonance-based wireless power transmission for millimeter-sized planar square inductors micro-magnetic stimulation | |
Zolj et al. | Electrically small dipole antenna probe for quasistatic electric field measurements in transcranial magnetic stimulation | |
Wen et al. | Wireless power transfer system for capsule robot designed by radial square transmitting coil pair with novel ferrite structure | |
Álvarez-Botero et al. | On the orientation of signal excitation for magnetically coupled human body communication |