Performance comparison of two signal multiplexing readouts for SiPM-based pet detector

Yang et al., 2019

Document ID
12390019475241545046
Author
Yang Q
Kuang Z
Sang Z
Yang Y
Du J
Publication year
Publication venue
Physics in Medicine & Biology

External Links

Snippet

PET scanners using SiPMs as photodetectors could have tens of thousands of SiPMs. To simplify the readout electronics, analog signal multiplexing readouts are always preferred to be used as early as possible. In this paper, two simple analog signal multiplexing readouts …
Continue reading at iopscience.iop.org (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/20Measuring radiation intensity with scintillation detectors
    • G01T1/2018Scintillation-photodiode combination
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/20Measuring radiation intensity with scintillation detectors
    • G01T1/2006Measuring radiation intensity with scintillation detectors using a combination of a scintillator and photodetector which measures the means radiation intensity
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/161Application in the field of nuclear medicine, e.g. in vivo counting
    • G01T1/164Scintigraphy
    • G01T1/1641Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/20Measuring radiation intensity with scintillation detectors
    • G01T1/2008Measuring radiation intensity with scintillation detectors using a combination of different types of scintillation detectors, e.g. phoswich
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/20Measuring radiation intensity with scintillation detectors
    • G01T1/202Measuring radiation intensity with scintillation detectors the detector being a crystal
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/29Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
    • G01T1/2914Measurement of spatial distribution of radiation
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/24Measuring radiation intensity with semiconductor detectors
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/02Dosimeters
    • G01T1/10Luminescent dosimeters

Similar Documents

Publication Publication Date Title
Yang et al. Performance comparison of two signal multiplexing readouts for SiPM-based pet detector
Peterson et al. SPECT detectors: the Anger Camera and beyond
Du et al. Performance of a high-resolution depth-encoding PET detector module using linearly-graded SiPM arrays
Mohammadi et al. Minimization of parallax error in positron emission tomography using depth of interaction capable detectors: methods and apparatus
Kwon et al. Bismuth germanate coupled to near ultraviolet silicon photomultipliers for time-of-flight PET
Kuang et al. Performance of a high-resolution depth encoding PET detector using barium sulfate reflector
Yamamoto et al. Development of an ultrahigh resolution Si-PM based PET system for small animals
Kwon et al. Dual-ended readout of bismuth germanate to improve timing resolution in time-of-flight PET
Ariño-Estrada et al. First Cerenkov charge-induction (CCI) TlBr detector for TOF-PET and proton range verification
Seifert et al. Monolithic LaBr3: Ce crystals on silicon photomultiplier arrays for time-of-flight positron emission tomography
Du et al. Performance comparison of dual-ended readout depth-encoding PET detectors based on BGO and LYSO crystals
Du et al. Performance comparison of depth-encoding detectors based on dual-ended readout and different SiPMs for high-resolution PET applications
Shao et al. Development of a prototype PET scanner with depth-of-interaction measurement using solid-state photomultiplier arrays and parallel readout electronics
Du et al. A depth-of-interaction encoding PET detector module with dual-ended readout using large-area silicon photomultiplier arrays
Son et al. A depth-of-interaction PET detector using a stair-shaped reflector arrangement and a single-ended scintillation light readout
Choe et al. Development of capacitive multiplexing circuit for SiPM-based time-of-flight (TOF) PET detector
Park et al. Hybrid charge division multiplexing method for silicon photomultiplier based PET detectors
Etxebeste et al. 3D position determination in monolithic crystals coupled to SiPMs for PET
Du et al. Design and evaluation of gapless curved scintillator arrays for simultaneous high-resolution and high-sensitivity brain PET
Kyme et al. Open-field mouse brain PET: design optimisation and detector characterisation
Poladyan et al. Gaussian position-weighted center of gravity algorithm for multiplexed readout
Won et al. Delay grid multiplexing: simple time-based multiplexing and readout method for silicon photomultipliers
Binder et al. Performance evaluation of a staggered three-layer DOI PET detector using a 1 mm LYSO pitch with PETsys TOFPET2 ASIC: comparison of HAMAMATSU and KETEK SiPMs
Kang et al. A staggered 3-layer DOI PET detector using BaSO4 reflector for enhanced crystal identification and inter-crystal scattering event discrimination capability
Yamamoto et al. Development of a high resolution gamma camera system using finely grooved GAGG scintillator