POSTEXTRASYSTOLIC POTENTIATION IN THE ACUTE AND CHRONIC DOG, AND A REPORT OF ONE CASE AT OPEN-HEART SURGERY IN MAN.STEIN et al., 1965
View PDF- Document ID
- 11884979249522886656
- Author
- STEIN E
- SH L
- BD K
- STAM F
- AN D
- Publication year
- Publication venue
- Bulletin of the New York Academy of Medicine
External Links
Snippet
METHODS AND MATERIALS Animal Experiments Paired and coupled pacingthrough an electrode catheter in the right ventricle. One dog weighing 35 lb. was anesthetized with 15 mg. per pound body weight of intravenous Na-pentobarbital. A bipolar electrode catheter …
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N1/00—Electrotherapy; Circuits therefor
- A61N1/18—Applying electric currents by contact electrodes
- A61N1/32—Applying electric currents by contact electrodes alternating or intermittent currents
- A61N1/36—Applying electric currents by contact electrodes alternating or intermittent currents for stimulation, e.g. heart pace-makers
- A61N1/362—Heart stimulators
- A61N1/365—Heart stimulators controlled by a physiological parameter, e.g. heart potential
- A61N1/368—Heart stimulators controlled by a physiological parameter, e.g. heart potential comprising more than one electrode co-operating with different heart regions
- A61N1/3684—Heart stimulators controlled by a physiological parameter, e.g. heart potential comprising more than one electrode co-operating with different heart regions for stimulating the heart at multiple sites of the ventricle or the atrium, e.g. biventricular stimulation
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N1/00—Electrotherapy; Circuits therefor
- A61N1/18—Applying electric currents by contact electrodes
- A61N1/32—Applying electric currents by contact electrodes alternating or intermittent currents
- A61N1/36—Applying electric currents by contact electrodes alternating or intermittent currents for stimulation, e.g. heart pace-makers
- A61N1/362—Heart stimulators
- A61N1/37—Monitoring; Protecting
- A61N1/3702—Monitoring; Protecting a physiological parameter
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N1/00—Electrotherapy; Circuits therefor
- A61N1/18—Applying electric currents by contact electrodes
- A61N1/32—Applying electric currents by contact electrodes alternating or intermittent currents
- A61N1/36—Applying electric currents by contact electrodes alternating or intermittent currents for stimulation, e.g. heart pace-makers
- A61N1/362—Heart stimulators
- A61N1/365—Heart stimulators controlled by a physiological parameter, e.g. heart potential
- A61N1/36514—Heart stimulators controlled by a physiological parameter, e.g. heart potential controlled by a physiological quantity other than heart potential, e.g. blood pressure
- A61N1/36521—Heart stimulators controlled by a physiological parameter, e.g. heart potential controlled by a physiological quantity other than heart potential, e.g. blood pressure the parameter being derivable from measurement of an electrical impedance
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N1/00—Electrotherapy; Circuits therefor
- A61N1/18—Applying electric currents by contact electrodes
- A61N1/32—Applying electric currents by contact electrodes alternating or intermittent currents
- A61N1/36—Applying electric currents by contact electrodes alternating or intermittent currents for stimulation, e.g. heart pace-makers
- A61N1/362—Heart stimulators
- A61N1/3621—Heart stimulators for treating or preventing abnormally high heart rate
- A61N1/3622—Heart stimulators for treating or preventing abnormally high heart rate comprising two or more electrodes co-operating with different heart regions
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N1/00—Electrotherapy; Circuits therefor
- A61N1/18—Applying electric currents by contact electrodes
- A61N1/32—Applying electric currents by contact electrodes alternating or intermittent currents
- A61N1/36—Applying electric currents by contact electrodes alternating or intermittent currents for stimulation, e.g. heart pace-makers
- A61N1/362—Heart stimulators
- A61N1/3627—Heart stimulators for treating a mechanical deficiency of the heart, e.g. congestive heart failure or cardionmyopathy
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N1/00—Electrotherapy; Circuits therefor
- A61N1/18—Applying electric currents by contact electrodes
- A61N1/32—Applying electric currents by contact electrodes alternating or intermittent currents
- A61N1/36—Applying electric currents by contact electrodes alternating or intermittent currents for stimulation, e.g. heart pace-makers
- A61N1/36042—Applying electric currents by contact electrodes alternating or intermittent currents for stimulation, e.g. heart pace-makers of grafted tissue, e.g. skeletal muscle
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N1/00—Electrotherapy; Circuits therefor
- A61N1/02—Details
- A61N1/04—Electrodes
- A61N1/05—Electrodes for implantation or insertion into the body, e.g. heart electrode
- A61N1/056—Transvascular endocardial electrode systems
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N1/00—Electrotherapy; Circuits therefor
- A61N1/18—Applying electric currents by contact electrodes
- A61N1/32—Applying electric currents by contact electrodes alternating or intermittent currents
- A61N1/38—Applying electric currents by contact electrodes alternating or intermittent currents for producing shock effects
- A61N1/39—Heart defibrillators
- A61N1/3956—Implantable devices for applying electric shocks to the heart, e.g. for cardioversion
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/04—Detecting, measuring or recording bioelectric signals of the body of parts thereof
- A61B5/0402—Electrocardiography, i.e. ECG
- A61B5/0452—Detecting specific parameters of the electrocardiograph cycle
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61M—DEVICES FOR INTRODUCING MEDIA INTO, OR ONTO, THE BODY; DEVICES FOR TRANSDUCING BODY MEDIA OR FOR TAKING MEDIA FROM THE BODY; DEVICES FOR PRODUCING OR ENDING SLEEP OR STUPOR
- A61M1/00—Suction or pumping devices for medical purposes; Devices for carrying-off, for treatment of, or for carrying-over, body-liquids; Drainage systems
- A61M1/10—Blood pumps; Artificial hearts; Devices for mechanical circulatory assistance, e.g. intra-aortic balloon pumps
- A61M1/1037—Pumps having flexible elements, e.g. with membranes, diaphragms, or bladder pumps
- A61M1/1067—Pumps having flexible elements, e.g. with membranes, diaphragms, or bladder pumps using a blood vessel as flexible element
Similar Documents
Publication | Publication Date | Title |
---|---|---|
ROSS JR et al. | Effects of changing heart rate in man by electrical stimulation of the right atrium: studies at rest, during exercise, and with isoproterenol | |
Lister et al. | Effect of pacemaker site on cardiac output and ventricular activation in dogs with complete heart block | |
Samet et al. | Atrial contribution to cardiac output in complete heart block | |
TAvEL et al. | Repetitive ventricular arrhythmia resulting from artificial internal pacemaker | |
US5024222A (en) | Hemodynamically rate responsive pacemaker and method of automatically adjusting the escape and A-V intervals | |
BF et al. | Effects of postextrasystolic potentiation on normal and failing hearts. | |
RYAN et al. | Paradoxical use of a demand pacemaker in treatment of supraventricular tachycardia due to the Wolff-Parkinson-White syndrome: observation on termination of reciprocal rhythm | |
EP1439882B1 (en) | Permanent atrial-his-ventricular sequential pacing | |
Sowton | Artificial pacemaking and sinus rhythm | |
US6295470B1 (en) | Antitachycardial pacing | |
US5861009A (en) | Implantable cardiac stimulator with rate-adaptive T-wave detection | |
US5391185A (en) | Atrial cardioverter with ventricular protection | |
JPS62137068A (en) | Heart pacemaker adapted to physyiological condition | |
Roy et al. | The effect of verapamil on the cardiac conduction system in man | |
Samet et al. | Hemodynamic sequelae of idioventricular pacemaking in complete heart block | |
Fitzpatrick et al. | Recurrent symptoms after ventricular pacing in unexplained syncope | |
STEIN et al. | POSTEXTRASYSTOLIC POTENTIATION IN THE ACUTE AND CHRONIC DOG, AND A REPORT OF ONE CASE AT OPEN-HEART SURGERY IN MAN. | |
Bonnabeau Jr et al. | OBSERVATIONS ON SUDDEN DEATH DURING PACEMAKER STIMULATION IN COMPLETE ATRIOVENTRICULAR BLOCK: Leading to the Development of a “P-Wave” Pacemaker without Atrial Leads | |
Beyersdorf et al. | Increase in cardiac output with rate-responsive pacemaker | |
Lister et al. | Conference on Paired Pulse Stimulation and Postextrasystolic Potentiation in the Heart—Part II: Postextrasystolic potentiation in the acute and chronic dog, and a report of one case at open-heart surgery in man | |
Araki et al. | Postextrasystolic transient contractile alternans in canine hearts | |
Smyth et al. | Permanent pervenous atrial pacing | |
Levine et al. | Assessment of atrial capture in committed atrioventricular sequential (DVI) pacing systems | |
Altamura et al. | Transcutaneous cardiac pacing: evaluation of cardiac activation | |
McCORMICK et al. | Intermittent pacemaker syndrome: Revision of VVI pacemaker to a new cardiac pacing mode for tachy‐brady syndrome |