Snippet
The integrated power Doppler signal arising from blood flow is a random process. In this article, a general approach to model this random process is studied. Both the theoretical and experimental results show that the temporal autocorrelation function of the integrated power …
- 238000005311 autocorrelation function 0 abstract description 18
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01S—RADIO DIRECTION-FINDING; RADIO NAVIGATION; DETERMINING DISTANCE OR VELOCITY BY USE OF RADIO WAVES; LOCATING OR PRESENCE-DETECTING BY USE OF THE REFLECTION OR RERADIATION OF RADIO WAVES; ANALOGOUS ARRANGEMENTS USING OTHER WAVES
- G01S15/00—Systems using the reflection or reradiation of acoustic waves, e.g. sonar systems
- G01S15/88—Sonar systems specially adapted for specific applications
- G01S15/89—Sonar systems specially adapted for specific applications for mapping or imaging
- G01S15/8906—Short-range imaging systems; Acoustic microscope systems using pulse-echo techniques
- G01S15/8979—Combined Doppler and pulse-echo imaging systems
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01S—RADIO DIRECTION-FINDING; RADIO NAVIGATION; DETERMINING DISTANCE OR VELOCITY BY USE OF RADIO WAVES; LOCATING OR PRESENCE-DETECTING BY USE OF THE REFLECTION OR RERADIATION OF RADIO WAVES; ANALOGOUS ARRANGEMENTS USING OTHER WAVES
- G01S15/00—Systems using the reflection or reradiation of acoustic waves, e.g. sonar systems
- G01S15/88—Sonar systems specially adapted for specific applications
- G01S15/89—Sonar systems specially adapted for specific applications for mapping or imaging
- G01S15/8906—Short-range imaging systems; Acoustic microscope systems using pulse-echo techniques
- G01S15/899—Combination of imaging systems with ancillary equipment
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01S—RADIO DIRECTION-FINDING; RADIO NAVIGATION; DETERMINING DISTANCE OR VELOCITY BY USE OF RADIO WAVES; LOCATING OR PRESENCE-DETECTING BY USE OF THE REFLECTION OR RERADIATION OF RADIO WAVES; ANALOGOUS ARRANGEMENTS USING OTHER WAVES
- G01S15/00—Systems using the reflection or reradiation of acoustic waves, e.g. sonar systems
- G01S15/88—Sonar systems specially adapted for specific applications
- G01S15/89—Sonar systems specially adapted for specific applications for mapping or imaging
- G01S15/8906—Short-range imaging systems; Acoustic microscope systems using pulse-echo techniques
- G01S15/895—Short-range imaging systems; Acoustic microscope systems using pulse-echo techniques characterised by the transmitted frequency spectrum
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01S—RADIO DIRECTION-FINDING; RADIO NAVIGATION; DETERMINING DISTANCE OR VELOCITY BY USE OF RADIO WAVES; LOCATING OR PRESENCE-DETECTING BY USE OF THE REFLECTION OR RERADIATION OF RADIO WAVES; ANALOGOUS ARRANGEMENTS USING OTHER WAVES
- G01S15/00—Systems using the reflection or reradiation of acoustic waves, e.g. sonar systems
- G01S15/02—Systems using the reflection or reradiation of acoustic waves, e.g. sonar systems using reflection of acoustic waves
- G01S15/50—Systems of measurement, based on relative movement of the target
- G01S15/58—Velocity or trajectory determination systems; Sense-of-movement determination systems
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01S—RADIO DIRECTION-FINDING; RADIO NAVIGATION; DETERMINING DISTANCE OR VELOCITY BY USE OF RADIO WAVES; LOCATING OR PRESENCE-DETECTING BY USE OF THE REFLECTION OR RERADIATION OF RADIO WAVES; ANALOGOUS ARRANGEMENTS USING OTHER WAVES
- G01S7/00—Details of systems according to groups G01S13/00, G01S15/00, G01S17/00
- G01S7/52—Details of systems according to groups G01S13/00, G01S15/00, G01S17/00 of systems according to group G01S15/00
- G01S7/52017—Details of systems according to groups G01S13/00, G01S15/00, G01S17/00 of systems according to group G01S15/00 particularly adapted to short-range imaging
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R33/00—Arrangements or instruments for measuring magnetic variables
- G01R33/20—Arrangements or instruments for measuring magnetic variables involving magnetic resonance
- G01R33/44—Arrangements or instruments for measuring magnetic variables involving magnetic resonance using nuclear magnetic resonance [NMR]
- G01R33/48—NMR imaging systems
- G01R33/54—Signal processing systems, e.g. using pulse sequences, Generation or control of pulse sequences ; Operator Console
- G01R33/56—Image enhancement or correction, e.g. subtraction or averaging techniques, e.g. improvement of signal-to-noise ratio and resolution
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B8/00—Diagnosis using ultrasonic, sonic or infrasonic waves
- A61B8/48—Diagnostic techniques
- A61B8/481—Diagnostic techniques involving the use of contrast agent, e.g. micro-bubbles introduced into the bloodstream
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B8/00—Diagnosis using ultrasonic, sonic or infrasonic waves
- A61B8/06—Measuring blood flow
Similar Documents
Publication | Publication Date | Title |
---|---|---|
US10792015B2 (en) | Estimation and display for vector doppler imaging using plane wave transmissions | |
Tremblay-Darveau et al. | Combined perfusion and Doppler imaging using plane-wave nonlinear detection and microbubble contrast agents | |
Chen et al. | Determination of scan‐plane motion using speckle decorrelation: Theoretical considerations and initial test | |
JP4457002B2 (en) | Ultrasound diagnostic microvascular imaging | |
EP0135170B2 (en) | Apparatus for observing blood flow patterns | |
Schulten‐Wijman et al. | Evaluation of volume vascularization index and flow index: a phantom study | |
Chen et al. | Non-Gaussian versus non-Rayleigh statistical properties of ultrasound echo signals | |
JPS62114539A (en) | Flow display apparatus utilizing ultrasonic wave | |
JP2005528964A (en) | Ultrasound diagnostic system for low flow rate contrast media | |
Chen et al. | Autocorrelation of integrated power Doppler signals and its application | |
Rubin et al. | Volume flow measurement using Doppler and grey-scale decorrelation | |
Bauer et al. | Acoustically stimulated microbubbles in diagnostic ultrasound: properties and implications for diagnostic use | |
DE2423318A1 (en) | METHOD OF MEASURING LIQUID FLOW | |
JP4502417B2 (en) | Methods and systems for displaying spectral spread error margins | |
Insana et al. | Characterising the microstructure of random media using ultrasound | |
McDicken et al. | The difference between Colour Doppler Velocity Imaging and Power Doppler Imaging. | |
Capineri et al. | A Doppler system for dynamic vector velocity maps | |
Middleton et al. | The carotid ghost. A color Doppler ultrasound duplication artifact. | |
US4683893A (en) | Amplitude conditional signal processing for ultrasound frequency estimation | |
Kargel et al. | Doppler ultrasound systems designed for tumor blood flow imaging | |
Tortoli et al. | Velocity profile reconstruction using ultrafast spectral analysis of Doppler ultrasound | |
Needles et al. | Interframe clutter filtering for high frequency flow imaging | |
Peronneau et al. | Structure and performances of mono-and bidimensional pulsed Doppler systems | |
Avdal et al. | Effects of reverberations and clutter filtering in pulsed Doppler using sparse sequences | |
Aida et al. | Quantification of aortic regurgitant volume by a newly developed automated cardiac flow measurement method: an in vitro study |