Sensitivity analysis of evaporative condensers performance using an experimental approachFiorentino et al., 2017
View PDF- Document ID
- 9959213929277148124
- Author
- Fiorentino M
- Starace G
- Publication year
- Publication venue
- Energy Procedia
External Links
Snippet
The evaporative condensers operate at lower condensing temperatures with respect to dry condensing units and involve reduced water consumption if compared with water cooled condensers. A test rig to investigate the evaporative condenser at small scale has been …
- 238000010206 sensitivity analysis 0 title abstract description 6
Classifications
-
- F—MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
- F24—HEATING; RANGES; VENTILATING
- F24F—AIR-CONDITIONING, AIR-HUMIDIFICATION, VENTILATION, USE OF AIR CURRENTS FOR SCREENING
- F24F3/00—Air-conditioning systems in which conditioned primary air is supplied from one or more central stations to distributing units in the rooms or spaces where it may receive secondary treatment; Apparatus specially designed for such systems
- F24F3/12—Air-conditioning systems in which conditioned primary air is supplied from one or more central stations to distributing units in the rooms or spaces where it may receive secondary treatment; Apparatus specially designed for such systems characterised by the treatment of the air otherwise than by heating and cooling
- F24F3/14—Air-conditioning systems in which conditioned primary air is supplied from one or more central stations to distributing units in the rooms or spaces where it may receive secondary treatment; Apparatus specially designed for such systems characterised by the treatment of the air otherwise than by heating and cooling by humidification; by dehumidification
-
- F—MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
- F24—HEATING; RANGES; VENTILATING
- F24F—AIR-CONDITIONING, AIR-HUMIDIFICATION, VENTILATION, USE OF AIR CURRENTS FOR SCREENING
- F24F11/00—Control or safety systems or apparatus
- F24F11/0009—Electrical control or safety systems or apparatus
- F24F11/001—Control systems or circuits characterised by their inputs, e.g. using sensors
-
- F—MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
- F28—HEAT EXCHANGE IN GENERAL
- F28F—DETAILS OF HEAT-EXCHANGE AND HEAT-TRANSFER APPARATUS, OF GENERAL APPLICATION
- F28F1/00—Tubular elements; Assemblies of tubular elements
- F28F1/10—Tubular lements and assemblies thereof with means for increasing heat-transfer area, e.g. with fins, with projections, with recesses
-
- F—MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
- F28—HEAT EXCHANGE IN GENERAL
- F28F—DETAILS OF HEAT-EXCHANGE AND HEAT-TRANSFER APPARATUS, OF GENERAL APPLICATION
- F28F13/00—Arrangements for modifying heat-transfer, e.g. increasing, decreasing
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Zheng et al. | Development of an experimental validated model of cross-flow indirect evaporative cooler with condensation | |
Duan et al. | Experimental study of a counter-flow regenerative evaporative cooler | |
Islam et al. | Experimental and numerical study of an evaporatively-cooled condenser of air-conditioning systems | |
Yin et al. | Experimental study on a new internally cooled/heated dehumidifier/regenerator of liquid desiccant systems | |
Al-Zubaydi et al. | Experimental study of a novel water-spraying configuration in indirect evaporative cooling | |
Chen et al. | Experimental investigation of plastic finned-tube heat exchangers, with emphasis on material thermal conductivity | |
Duan et al. | Design, fabrication and performance evaluation of a compact regenerative evaporative cooler: Towards low energy cooling for buildings | |
Fiorentino et al. | The design of countercurrent evaporative condensers with the hybrid method | |
Fiorentino et al. | Sensitivity analysis of evaporative condensers performance using an experimental approach | |
Fiorentino et al. | Experimental investigations on evaporative condensers performance | |
Wen et al. | Development and experimental study of a novel plate dehumidifier made of anodized aluminum | |
Chen et al. | Experimental study of plate type air cooler performances under four operating modes | |
Yashar et al. | Rooftop air-conditioning unit performance improvement using refrigerant circuitry optimization | |
Bai et al. | Performance evaluation of a membrane-based flat-plate heat and mass exchanger used for liquid desiccant regeneration | |
Fiorentino et al. | Numerical and experimental performance analysis of evaporative condensers | |
Yan et al. | Performance evaluation and parameter sensitivity analysis of a membrane-based evaporative cooler with built-in baffles | |
Cui et al. | Experimental study on a moisture-conducting fiber-assisted tubular indirect evaporative cooler | |
Fang et al. | High-performance multi-stage internally-cooled liquid desiccant dehumidifier for high gas–liquid flow ratios | |
Zhou et al. | Study on heat and mass transfer characteristics of internally-cooled hollow fiber membrane-based liquid desiccant dehumidifiers | |
Hu et al. | Air side performance of fin-and-tube heat exchangers with a hydrophilic layer under low-temperature frost-free conditions | |
Alkhalidi et al. | Condenser designs for greenhouse desalination | |
Fiorentino et al. | Experimental investigations on air side heat and mass transfer phenomena in evaporative condensers | |
Aganda et al. | A comparison of the predicted and experimental heat transfer performance of a finned tube evaporator | |
Ilie et al. | Experimental investigation of condensation heat transfer in ammonia evaporative condensers | |
Duong et al. | Numerical analysis of a compressor type of dehumidifier:(I) Fluid Flow |