An experimental study of a cross-flow type plate heat exchanger for dehumidification/cooling

Saman et al., 2002

View PDF
Document ID
9218905553345048811
Author
Saman W
Alizadeh S
Publication year
Publication venue
Solar Energy

External Links

Snippet

The thermal and dehumidification behaviour of a standard cross-flow type plate heat exchanger, intended for use as a dehumidifier/cooler, has been investigated both experimentally and numerically. Three sets of experiments have been carried out where air …
Continue reading at www.academia.edu (PDF) (other versions)

Classifications

    • FMECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
    • F24HEATING; RANGES; VENTILATING
    • F24FAIR-CONDITIONING, AIR-HUMIDIFICATION, VENTILATION, USE OF AIR CURRENTS FOR SCREENING
    • F24F3/00Air-conditioning systems in which conditioned primary air is supplied from one or more central stations to distributing units in the rooms or spaces where it may receive secondary treatment; Apparatus specially designed for such systems
    • F24F3/12Air-conditioning systems in which conditioned primary air is supplied from one or more central stations to distributing units in the rooms or spaces where it may receive secondary treatment; Apparatus specially designed for such systems characterised by the treatment of the air otherwise than by heating and cooling
    • F24F3/14Air-conditioning systems in which conditioned primary air is supplied from one or more central stations to distributing units in the rooms or spaces where it may receive secondary treatment; Apparatus specially designed for such systems characterised by the treatment of the air otherwise than by heating and cooling by humidification; by dehumidification
    • F24F3/1411Air-conditioning systems in which conditioned primary air is supplied from one or more central stations to distributing units in the rooms or spaces where it may receive secondary treatment; Apparatus specially designed for such systems characterised by the treatment of the air otherwise than by heating and cooling by humidification; by dehumidification by absorbing or adsorbing water, e.g. using an hygroscopic desiccant
    • FMECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
    • F24HEATING; RANGES; VENTILATING
    • F24FAIR-CONDITIONING, AIR-HUMIDIFICATION, VENTILATION, USE OF AIR CURRENTS FOR SCREENING
    • F24F11/00Control or safety systems or apparatus
    • F24F11/0009Electrical control or safety systems or apparatus
    • F24F11/001Control systems or circuits characterised by their inputs, e.g. using sensors
    • FMECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
    • F24HEATING; RANGES; VENTILATING
    • F24FAIR-CONDITIONING, AIR-HUMIDIFICATION, VENTILATION, USE OF AIR CURRENTS FOR SCREENING
    • F24F11/00Control or safety systems or apparatus
    • F24F11/0009Electrical control or safety systems or apparatus
    • F24F11/0086Control systems or circuits characterised by other control features, e.g. display or monitoring devices
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N25/00Investigating or analyzing materials by the use of thermal means
    • G01N25/56Investigating or analyzing materials by the use of thermal means by investigating moisture content

Similar Documents

Publication Publication Date Title
Saman et al. An experimental study of a cross-flow type plate heat exchanger for dehumidification/cooling
Longo et al. Experimental and theoretical analysis of heat and mass transfer in a packed column dehumidifier/regenerator with liquid desiccant
Jain et al. Experimental studies on the dehumidifier and regenerator of a liquid desiccant cooling system
Al-Zubaydi et al. Experimental study of a novel water-spraying configuration in indirect evaporative cooling
Park et al. Experimental analysis of dehumidification performance of an evaporative cooling-assisted internally cooled liquid desiccant dehumidifier
Woods et al. A desiccant-enhanced evaporative air conditioner: Numerical model and experiments
Qi et al. Investigation on wetted area and film thickness for falling film liquid desiccant regeneration system
Cho et al. Experimental analysis of dehumidification performance of counter and cross-flow liquid desiccant dehumidifiers
Koronaki et al. Thermodynamic analysis of a counter flow adiabatic dehumidifier with different liquid desiccant materials
Namvar et al. + Transient characteristics of a liquid-to-air membrane energy exchanger (LAMEE) experimental data with correlations
Hasan et al. Performance investigation of plain and finned tube evaporatively cooled heat exchangers
Bai et al. Performance testing of a cross-flow membrane-based liquid desiccant dehumidification system
Pandelidis et al. Performance study of the Maisotsenko Cycle heat exchangers in different air-conditioning applications
Liu et al. A theoretical model to predict frosting limits in cross-flow air-to-air flat plate heat/energy exchangers
Ge et al. Comparison of experimental data and a model for heat and mass transfer performance of a liquid-to-air membrane energy exchanger (LAMEE) when used for air dehumidification and salt solution regeneration
Yin et al. Experimental study on a new internally cooled/heated dehumidifier/regenerator of liquid desiccant systems
Zheng et al. Development of an experimental validated model of cross-flow indirect evaporative cooler with condensation
De Antonellis et al. Desiccant wheels effectiveness parameters: correlations based on experimental data
Saman et al. Modelling and performance analysis of a cross-flow type plate heat exchanger for dehumidification/cooling
Chen et al. Experimental investigation of plastic finned-tube heat exchangers, with emphasis on material thermal conductivity
Fiorentino et al. The design of countercurrent evaporative condensers with the hybrid method
Mirth et al. Prediction of cooling-coil performance under condensing conditions
Huang et al. Experimental investigation on heat and mass transfer in heating tower solution regeneration using packing tower
Wen et al. Thermal properties study and performance investigation of potassium formate solution in a falling film dehumidifier/regenerator
Guo et al. Development of model based on condensation area ratio and effect on heat transfer capacity of indirect evaporative cooling