Ionita et al., 2012 - Google Patents
New head equivalent phantom for task and image performance evaluation representative for neurovascular procedures occurring in the Circle of WillisIonita et al., 2012
View HTML- Document ID
- 8965956385337400881
- Author
- Ionita C
- Loughran B
- Jain A
- Vasan S
- Bednarek D
- Levy E
- Siddiqui A
- Snyder K
- Hopkins L
- Rudin S
- Publication year
- Publication venue
- Medical Imaging 2012: Physics of Medical Imaging
External Links
Snippet
Phantom equivalents of different human anatomical parts are routinely used for imaging system evaluation or dose calculations. The various recommendations on the generic phantom structure given by organizations such as the AAPM, are not always accurate when …
- 210000000275 Circle of Willis 0 title abstract description 18
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/58—Testing, adjusting or calibrating devices for radiation diagnosis
- A61B6/582—Calibration
- A61B6/583—Calibration using calibration phantoms
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/48—Diagnostic techniques
- A61B6/481—Diagnostic techniques involving the use of contrast agents
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/50—Clinical applications
- A61B6/504—Clinical applications involving diagnosis of blood vessels, e.g. by angiography
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/032—Transmission computed tomography [CT]
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/44—Constructional features of the device for radiation diagnosis
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/04—Positioning of patients; Tiltable beds or the like
- A61B6/0407—Tables or beds
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/42—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for detecting radiation specially adapted for radiation diagnosis
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/54—Control of devices for radiation diagnosis
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/52—Devices using data or image processing specially adapted for radiation diagnosis
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B17/00—Surgical instruments, devices or methods, e.g. tourniquets
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B8/00—Diagnosis using ultrasonic, sonic or infrasonic waves
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Mahesh | Fluoroscopy: patient radiation exposure issues | |
McCollough et al. | CT dose reduction and dose management tools: overview of available options | |
Boone et al. | Dose reduction in pediatric CT: a rational approach | |
Rehani et al. | ICRP publication 129: radiological protection in cone beam computed tomography (CBCT) | |
Vano et al. | Staff radiation doses in interventional cardiology: correlation with patient exposure | |
Mastora et al. | Multi–detector row spiral CT angiography of the thoracic outlet: dose reduction with anatomically adapted online tube current modulation and preset dose savings | |
Dehairs et al. | Evaluation of automatic dose rate control for flat panel imaging using a spatial frequency domain figure of merit | |
US7157696B2 (en) | Test object for calibration of imaging measurements of mammalian skeletal joints | |
Hackenbroch et al. | Low-dose CT in pelvic imaging: comparing dose and image quality in relation to clinical value in a phantom study | |
Ionita et al. | New head equivalent phantom for task and image performance evaluation representative for neurovascular procedures occurring in the Circle of Willis | |
Dehairs et al. | Implementation of a spatio-temporal figure of merit for new automatic dose rate control regimes in dynamic x-ray imaging | |
Karim et al. | A comparative study of radiation doses between phantom and patients via CT angiography of the intra-/extra-cranial, pulmonary, and abdominal/pelvic arteries | |
Guggenberger et al. | Flat-panel CT arthrography: feasibility study and comparison to multidetector CT arthrography | |
Dehairs et al. | A study of the impact of x-ray tube performance on angiography system imaging efficiency | |
Schafer et al. | Filtered region of interest cone‐beam rotational angiography | |
Ng et al. | Imaging phantoms: conventional X-ray imaging applications | |
US20100027751A1 (en) | Method for the production of angiography recordings | |
Harun et al. | Task-based assessment on various optimization protocols of computed tomography Pulmonary Angiography examination | |
Lubis et al. | Novel phantom for performance evaluation of contrast-enhanced 3D rotational angiography | |
Lehti et al. | Iterative metal artifact reduction in aortic CTA after Onyx®-embolization | |
CN103054606B (en) | Method and device of obtaining linear attenuation coefficient distribution based on CT (Computed Tomography) images | |
Lai et al. | Effective doses in children: association with common complex imaging techniques used during interventional radiology procedures | |
Flach et al. | Low dose tomographic fluoroscopy: 4D intervention guidance with running prior | |
Tsalafoutas et al. | Evaluation of image quality and patient exposure in fluoroscopy using a phantom: Is there any clinical relevance? | |
Dimitroukas et al. | Organs’ absorbed dose and comparison of different methods for effective dose calculation in computed tomography of parathyroid glands |