Pullia et al., 2018 - Google Patents

Note: A 102 dB dynamic-range charge-sampling readout for ionizing particle/radiation detectors based on an application-specific integrated circuit (ASIC)

Pullia et al., 2018

View PDF
Document ID
8021622581926162833
Author
Pullia A
Zocca F
Capra S
Publication year
Publication venue
Review of Scientific Instruments

External Links

Snippet

An original technique for the measurement of charge signals from ionizing particle/radiation detectors has been implemented in an application-specific integrated circuit form. The device performs linear measurements of the charge both within and beyond its output …
Continue reading at air.unimi.it (PDF) (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/24Measuring radiation intensity with semiconductor detectors
    • G01T1/241Electrode arrangements, e.g. continuous or parallel strips or the like
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/20Measuring radiation intensity with scintillation detectors
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/29Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
    • G01T1/2914Measurement of spatial distribution of radiation
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/02Dosimeters
    • G01T1/026Semiconductor dose-rate meters
    • HELECTRICITY
    • H03BASIC ELECTRONIC CIRCUITRY
    • H03FAMPLIFIERS
    • H03F3/00Amplifiers with only discharge tubes or only semiconductor devices as amplifying elements
    • H03F3/04Amplifiers with only discharge tubes or only semiconductor devices as amplifying elements with semiconductor devices only
    • H03F3/08Amplifiers with only discharge tubes or only semiconductor devices as amplifying elements with semiconductor devices only controlled by light

Similar Documents

Publication Publication Date Title
Calò et al. SiPM readout electronics
Liao et al. Pulse shape discrimination using EJ-299-33 plastic scintillator coupled with a Silicon Photomultiplier array
Pullia et al. Note: A 102 dB dynamic-range charge-sampling readout for ionizing particle/radiation detectors based on an application-specific integrated circuit (ASIC)
Brogna et al. N-XYTER, a CMOS read-out ASIC for high resolution time and amplitude measurements on high rate multi-channel counting mode neutron detectors
Gómez et al. MUSIC: An 8 channel readout ASIC for SiPM arrays
Phipps et al. A HEMT-based cryogenic charge amplifier with sub-100 eVee ionization resolution for massive semiconductor dark matter detectors
De Geronimo et al. Readout ASIC for 3D position-sensitive detectors
West et al. Compact readout of large CLYC scintillators with silicon photomultipler arrays
Ahmad et al. Omega sipm readout asics
Gao et al. Characteristics of a multichannel low-noise front-end ASIC for CZT-based small animal PET imaging
Deng et al. An ultra-low noise cryogenic CMOS charge sensitive preamplifier for large volume point-contact HPGe detectors
Cardarelli et al. Development of multi-layer crystal detector and related front end electronics
Wang et al. Design and testing of a miniature silicon strip detector
Paolozzi et al. Test beam measurement of the first prototype of the fast silicon pixel monolithic detector for the TT-PET project
Bassini et al. A low-noise charge amplifier with fast rise time and active discharge mechanism
Kroeger et al. Charge sensitive preamplifier and pulse shaper using CMOS process for germanium spectroscopy
Geronimo Low‐Noise Electronics for Radiation Sensors
Albuquerque et al. A Full Current-Mode Timing Circuit with Dark Noise Suppression for the CERN CMS Experiment
Değerli Design of fundamental building blocks for fast binary readout CMOS sensors used in high-energy physics experiments
Değerli et al. A digital monolithic active pixel sensor chip in a quadruple-well CIS process for tracking applications
Kishimoto et al. Nuclear resonant scattering measurements on 57Fe by multichannel scaling with a 64-pixel silicon avalanche photodiode linear-array detector
Jérôme et al. A 0.35 µm low-noise stable charge sensitive amplifier for silicon detectors applications
Pullia et al. Design of a resistorless ASIC preamplifier for HPGe detectors with non-linear pole/zero cancellation and controlled fast-reset feature
Pullia et al. Extending the dynamic range of nuclear pulse spectrometers
Li et al. Coincidence time resolution of radiation detector based on 6× 6 mm2 ToF SiPM detectors with different readout schemes