Mavroidis et al., 1998 - Google Patents

High performance medical robot requirements and accuracy analysis

Mavroidis et al., 1998

View PDF
Document ID
7875410351022821488
Author
Mavroidis C
Flanz J
Dubowsky S
Drouet P
Goitein M
Publication year
Publication venue
Robotics and Computer-Integrated Manufacturing

External Links

Snippet

The treatment of disease using particle beams requires highly accurate patient positioning. Patients must be well immobilized and precisely aligned with the treatment beam to take full advantage of the dose localization potential. Robots can be used as high accuracy patient …
Continue reading at citeseerx.ist.psu.edu (PDF) (other versions)

Classifications

    • GPHYSICS
    • G05CONTROLLING; REGULATING
    • G05BCONTROL OR REGULATING SYSTEMS IN GENERAL; FUNCTIONAL ELEMENTS OF SUCH SYSTEMS; MONITORING OR TESTING ARRANGEMENTS FOR SUCH SYSTEMS OR ELEMENTS
    • G05B2219/00Program-control systems
    • G05B2219/30Nc systems
    • G05B2219/40Robotics, robotics mapping to robotics vision
    • G05B2219/40611Camera to monitor endpoint, end effector position
    • GPHYSICS
    • G05CONTROLLING; REGULATING
    • G05BCONTROL OR REGULATING SYSTEMS IN GENERAL; FUNCTIONAL ELEMENTS OF SUCH SYSTEMS; MONITORING OR TESTING ARRANGEMENTS FOR SUCH SYSTEMS OR ELEMENTS
    • G05B2219/00Program-control systems
    • G05B2219/30Nc systems
    • G05B2219/39Robotics, robotics to robotics hand
    • GPHYSICS
    • G05CONTROLLING; REGULATING
    • G05BCONTROL OR REGULATING SYSTEMS IN GENERAL; FUNCTIONAL ELEMENTS OF SUCH SYSTEMS; MONITORING OR TESTING ARRANGEMENTS FOR SUCH SYSTEMS OR ELEMENTS
    • G05B2219/00Program-control systems
    • G05B2219/30Nc systems
    • G05B2219/37Measurements
    • G05B2219/37275Laser, interferometer
    • GPHYSICS
    • G05CONTROLLING; REGULATING
    • G05BCONTROL OR REGULATING SYSTEMS IN GENERAL; FUNCTIONAL ELEMENTS OF SUCH SYSTEMS; MONITORING OR TESTING ARRANGEMENTS FOR SUCH SYSTEMS OR ELEMENTS
    • G05B2219/00Program-control systems
    • G05B2219/30Nc systems
    • G05B2219/45Nc applications
    • GPHYSICS
    • G05CONTROLLING; REGULATING
    • G05BCONTROL OR REGULATING SYSTEMS IN GENERAL; FUNCTIONAL ELEMENTS OF SUCH SYSTEMS; MONITORING OR TESTING ARRANGEMENTS FOR SUCH SYSTEMS OR ELEMENTS
    • G05B19/00Programme-control systems
    • G05B19/02Programme-control systems electric
    • G05B19/18Numerical control [NC], i.e. automatically operating machines, in particular machine tools, e.g. in a manufacturing environment, so as to execute positioning, movement or co-ordinated operations by means of programme data in numerical form
    • G05B19/401Numerical control [NC], i.e. automatically operating machines, in particular machine tools, e.g. in a manufacturing environment, so as to execute positioning, movement or co-ordinated operations by means of programme data in numerical form characterised by control arrangements for measuring, e.g. calibration and initialisation, measuring workpiece for machining purposes
    • G05B19/4015Numerical control [NC], i.e. automatically operating machines, in particular machine tools, e.g. in a manufacturing environment, so as to execute positioning, movement or co-ordinated operations by means of programme data in numerical form characterised by control arrangements for measuring, e.g. calibration and initialisation, measuring workpiece for machining purposes going to a reference at the beginning of machine cycle, e.g. for calibration

Similar Documents

Publication Publication Date Title
Meggiolaro et al. Geometric and elastic error calibration of a high accuracy patient positioning system
Mavroidis et al. A systematic error analysis of robotic manipulators: application to a high performance medical robot
US10010331B2 (en) Systems and devices for a counter balanced surgical robot
Nuelle et al. Modeling, calibration, and evaluation of a tendon-actuated planar parallel continuum robot
Mavroidis et al. High performance medical robot requirements and accuracy analysis
Vahebi et al. Accuracy improvement of volumetric error modeling in CNC machine tools
Lee et al. Error modeling for sensitivity analysis and calibration of the tri-pyramid parallel robot
Fu et al. Kinematic accuracy research of a novel six-degree-of-freedom parallel robot with three legs
Fu et al. Analysis of unified error model and simulated parameters calibration for robotic machining based on Lie theory
Li et al. Kinematic calibration of serial robot using dual quaternions
Drouet et al. Compensation of geometric and elastic errors in large manipulators with an application to a high accuracy medical system
Bai et al. Kinematic calibration and pose measurement of a medical parallel manipulator by optical position sensors
Liu et al. Kinematic calibration of a six-legged walking machine tool
Glavonjic et al. Desktop 3-axis parallel kinematic milling machine
Meggiolaro et al. Identification and compensation of geometric and elastic errors in large manipulators: application to a high accuracy medical robot
Schadlbauer et al. A complete analysis of singularities of a parallel medical robot
Saadah et al. Kinematics Study for Linkage System (Parallel Robotics System): linkage system of patient positioning system PPS to accurately position a human body for radiosurgery treatment
Saadah et al. A State-of-the-Art Design: Applying Forward Kinematics to Improve Patient Positioning in Radiosurgery
Drouet et al. Compensation of geometric and elastic deflection errors in large manipulators based on experimental measurements: Application to a high accuracy medical manipulator
Cai et al. Configuration design and load capacity analysis of pelvic fracture reduction robot
Bhutani Modeling design and development of frameless stereotaxy in robot assisted neurosurgery
Meggiolaro et al. Error identification and compensation in large manipulators with application in cancer proton therapy
Stolka et al. Improving navigation precision of milling operations in surgical robotics
Donnici et al. Using navi-robot and a CT scanner to guide biopsy needles
Li et al. Error identification and compensation regarding the kinematic parameter of the MD-PEF for tibial deformity correction