Pérez et al., 2019 - Google Patents
DOSIS: An integrated computational tool for patient-specific dosimetry in nuclear medicine by Monte Carlo and dose point kernel approachesPérez et al., 2019
- Document ID
- 5423477674914857305
- Author
- Pérez P
- Valente M
- Publication year
- Publication venue
- Applied Radiation and Isotopes
External Links
Snippet
The use of radiolabeled molecules for tumor targeting constitutes a remarkable technique for the treatment of systemic malignancies. An accurate patient-specific dosimetry in nuclear medicine procedures should be a relevant pre-requisite in order to achieve the required …
- 238000004980 dosimetry 0 title abstract description 30
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/103—Treatment planning systems
- A61N5/1031—Treatment planning systems using a specific method of dose optimization
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/50—Clinical applications
- A61B6/507—Clinical applications involving determination of haemodynamic parameters, e.g. perfusion CT
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/037—Emission tomography
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N2005/1092—Details
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/50—Clinical applications
- A61B6/508—Clinical applications for non-human patients
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61K—PREPARATIONS FOR MEDICAL, DENTAL, OR TOILET PURPOSES
- A61K51/00—Preparations containing radioactive substances for use in therapy or testing in vivo
- A61K51/02—Preparations containing radioactive substances for use in therapy or testing in vivo characterised by the carrier, i.e. characterised by the agent or material covalently linked or complexing the radioactive nucleus
- A61K51/04—Preparations containing radioactive substances for use in therapy or testing in vivo characterised by the carrier, i.e. characterised by the agent or material covalently linked or complexing the radioactive nucleus organic compounds
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/48—Diagnostic techniques
- A61B6/481—Diagnostic techniques involving the use of contrast agents
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/10—Image acquisition modality
- G06T2207/10072—Tomographic images
- G06T2207/10104—Positron emission tomography [PET]
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Huang et al. | Patient-specific dosimetry using pretherapy [124 I] m-iodobenzylguanidine ([124 I] mIBG) dynamic PET/CT imaging before [131 I] mIBG targeted radionuclide therapy for neuroblastoma | |
Braat et al. | Safety analysis of holmium-166 microsphere scout dose imaging during radioembolisation work-up: a cohort study | |
Jackson et al. | An automated voxelized dosimetry tool for radionuclide therapy based on serial quantitative SPECT/CT imaging | |
Mikell et al. | Comparing voxel-based absorbed dosimetry methods in tumors, liver, lung, and at the liver-lung interface for 90Y microsphere selective internal radiation therapy | |
Pérez et al. | DOSIS: An integrated computational tool for patient-specific dosimetry in nuclear medicine by Monte Carlo and dose point kernel approaches | |
Yue et al. | Comparison of quantitative Y‐90 SPECT and non‐time‐of‐flight PET imaging in post‐therapy radioembolization of liver cancer | |
Mikell et al. | Selective internal radiation therapy with yttrium-90 glass microspheres: biases and uncertainties in absorbed dose calculations between clinical dosimetry models | |
Gosewisch et al. | 3D Monte Carlo bone marrow dosimetry for Lu-177-PSMA therapy with guidance of non-invasive 3D localization of active bone marrow via Tc-99m-anti-granulocyte antibody SPECT/CT | |
Eaton et al. | Quantitative dosimetry for yttrium-90 radionuclide therapy: tumor dose predicts fluorodeoxyglucose positron emission tomography response in hepatic metastatic melanoma | |
Marcatili et al. | Model‐based versus specific dosimetry in diagnostic context: comparison of three dosimetric approaches | |
Akabani et al. | Patient-specific dosimetry using quantitative SPECT imaging and three-dimensional discrete Fourier transform convolution | |
He et al. | Evaluation of quantitative imaging methods for organ activity and residence time estimation using a population of phantoms having realistic variations in anatomy and uptake | |
Pacilio et al. | Impact of SPECT corrections on 3D‐dosimetry for liver transarterial radioembolization using the patient relative calibration methodology | |
Papadimitroulas et al. | A personalized, Monte Carlo‐based method for internal dosimetric evaluation of radiopharmaceuticals in children | |
Ramonaheng et al. | The effect of calibration factors and recovery coefficients on 177 Lu SPECT activity quantification accuracy: a Monte Carlo study | |
Kim et al. | Comparison of voxel S‐value methods for personalized voxel‐based dosimetry of 177Lu‐DOTATATE | |
Larsson et al. | Use of Monte Carlo simulations with a realistic rat phantom for examining the correlation between hematopoietic system response and red marrow absorbed dose in Brown Norway rats undergoing radionuclide therapy with 177Lu‐and 90Y‐BR96 mAbs | |
Mansouri et al. | Deep transformer-based personalized dosimetry from SPECT/CT images: a hybrid approach for [177Lu] Lu-DOTATATE radiopharmaceutical therapy | |
Abdul Hadi et al. | Utilizing 3D Slicer to incorporate tomographic images into GATE Monte Carlo simulation for personalized dosimetry in yttrium‐90 radioembolization | |
Dieudonné et al. | Absorbed-dose calculation for treatment of liver neoplasms with 90 Y-microspheres | |
Pérez et al. | Dosimetry for betaemitter radionuclides by means of Monte Carlo simulations | |
Chen et al. | Voxel-S-value methods adapted to heterogeneous media for quantitative Y-90 microsphere radioembolization dosimetry | |
Häggström et al. | Compartment modeling of dynamic brain PET—The impact of scatter corrections on parameter errors | |
Henry et al. | Post-administration dosimetry in yttrium-90 radioembolization through micro-CT imaging of radiopaque microspheres in a porcine renal model | |
Silva et al. | Preclinical radiation internal dosimetry in the development of new radiopharmaceuticals using GATE Monte Carlo simulation |