The persistence of retro-commissioning savings in ten university buildingsToole, 2012
View PDF- Document ID
- 537392561642266206
- Author
- Toole C
- Publication year
External Links
Snippet
This study evaluated how well energy savings persisted over time in ten university buildings that had undergone retro-commissioning in 1996. The savings achieved immediately following retro-commissioning and in three subsequent years were documented in a …
- 230000002688 persistence 0 title abstract description 108
Classifications
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06Q—DATA PROCESSING SYSTEMS OR METHODS, SPECIALLY ADAPTED FOR ADMINISTRATIVE, COMMERCIAL, FINANCIAL, MANAGERIAL, SUPERVISORY OR FORECASTING PURPOSES; SYSTEMS OR METHODS SPECIALLY ADAPTED FOR ADMINISTRATIVE, COMMERCIAL, FINANCIAL, MANAGERIAL, SUPERVISORY OR FORECASTING PURPOSES, NOT OTHERWISE PROVIDED FOR
- G06Q10/00—Administration; Management
- G06Q10/06—Resources, workflows, human or project management, e.g. organising, planning, scheduling or allocating time, human or machine resources; Enterprise planning; Organisational models
- G06Q10/063—Operations research or analysis
- G06Q10/0639—Performance analysis
- G06Q10/06393—Score-carding, benchmarking or key performance indicator [KPI] analysis
-
- F—MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
- F24—HEATING; RANGES; VENTILATING
- F24F—AIR-CONDITIONING, AIR-HUMIDIFICATION, VENTILATION, USE OF AIR CURRENTS FOR SCREENING
- F24F11/00—Control or safety systems or apparatus
- F24F11/0009—Electrical control or safety systems or apparatus
- F24F11/0086—Control systems or circuits characterised by other control features, e.g. display or monitoring devices
- F24F2011/0091—Display or monitoring devices
-
- F—MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
- F24—HEATING; RANGES; VENTILATING
- F24F—AIR-CONDITIONING, AIR-HUMIDIFICATION, VENTILATION, USE OF AIR CURRENTS FOR SCREENING
- F24F11/00—Control or safety systems or apparatus
- F24F11/0009—Electrical control or safety systems or apparatus
- F24F11/001—Control systems or circuits characterised by their inputs, e.g. using sensors
- F24F2011/0041—Pressure
- F24F2011/0042—Air pressure
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06Q—DATA PROCESSING SYSTEMS OR METHODS, SPECIALLY ADAPTED FOR ADMINISTRATIVE, COMMERCIAL, FINANCIAL, MANAGERIAL, SUPERVISORY OR FORECASTING PURPOSES; SYSTEMS OR METHODS SPECIALLY ADAPTED FOR ADMINISTRATIVE, COMMERCIAL, FINANCIAL, MANAGERIAL, SUPERVISORY OR FORECASTING PURPOSES, NOT OTHERWISE PROVIDED FOR
- G06Q50/00—Systems or methods specially adapted for a specific business sector, e.g. utilities or tourism
- G06Q50/06—Electricity, gas or water supply
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06Q—DATA PROCESSING SYSTEMS OR METHODS, SPECIALLY ADAPTED FOR ADMINISTRATIVE, COMMERCIAL, FINANCIAL, MANAGERIAL, SUPERVISORY OR FORECASTING PURPOSES; SYSTEMS OR METHODS SPECIALLY ADAPTED FOR ADMINISTRATIVE, COMMERCIAL, FINANCIAL, MANAGERIAL, SUPERVISORY OR FORECASTING PURPOSES, NOT OTHERWISE PROVIDED FOR
- G06Q30/00—Commerce, e.g. shopping or e-commerce
- G06Q30/02—Marketing, e.g. market research and analysis, surveying, promotions, advertising, buyer profiling, customer management or rewards; Price estimation or determination
- G06Q30/0202—Market predictions or demand forecasting
-
- G—PHYSICS
- G05—CONTROLLING; REGULATING
- G05B—CONTROL OR REGULATING SYSTEMS IN GENERAL; FUNCTIONAL ELEMENTS OF SUCH SYSTEMS; MONITORING OR TESTING ARRANGEMENTS FOR SUCH SYSTEMS OR ELEMENTS
- G05B15/00—Systems controlled by a computer
- G05B15/02—Systems controlled by a computer electric
-
- G—PHYSICS
- G05—CONTROLLING; REGULATING
- G05B—CONTROL OR REGULATING SYSTEMS IN GENERAL; FUNCTIONAL ELEMENTS OF SUCH SYSTEMS; MONITORING OR TESTING ARRANGEMENTS FOR SUCH SYSTEMS OR ELEMENTS
- G05B23/00—Testing or monitoring of control systems or parts thereof
- G05B23/02—Electric testing or monitoring
- G05B23/0205—Electric testing or monitoring by means of a monitoring system capable of detecting and responding to faults
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Wang et al. | Monitoring-based HVAC commissioning of an existing office building for energy efficiency | |
Claridge et al. | Building simulation for practical operational optimization | |
Bynum et al. | Development and testing of an automated building commissioning analysis tool (ABCAT) | |
Raftery et al. | Calibrating whole building energy models: An evidence-based methodology | |
Haberl et al. | ASHRAE's Guideline 14-2002 for Measurement of Energy and Demand Savings: How to Determine what was really saved by the retrofit | |
Zibin et al. | Automatic assisted calibration tool for coupling building automation system trend data with commissioning | |
Jayaweera et al. | The uniform methods project: methods for determining energy efficiency savings for specific measures | |
Sretenovic | Analysis of energy use at university campus | |
Wang et al. | Field evaluation of advanced controls for the retrofit of packaged air conditioners and heat pumps | |
Luther et al. | Defining and developing an energy retrofitting approach | |
Toole | The persistence of retro-commissioning savings in ten university buildings | |
Butzbaugh et al. | Automatic Fault Detection & Diagnostics: Residential Market Analysis | |
Albayati et al. | Bringing automated fault detection and diagnostics tools for HVAC&R into the mainstream | |
Li et al. | System-level key performance indicators (KPIs) for building performance evaluation | |
Cho | The persistence of savings obtained from commissioning of existing buildings | |
Monfet | New ongoing commissioning approach of central plants: methodology and case study | |
Oh | Quantifying the electricity savings from the use of home automation devices in a residence | |
Valoria et al. | Increasing Uptake of Residential HVAC Commissioning with Advanced Technologies | |
Djuric | Real-time supervision of building HVAC system performance | |
Baylon et al. | Ductless Heat Pump Impact & Process Evaluation: Field Metering Report | |
Olli et al. | Monitoring and continuous Commissioning of new and existing Buildings | |
Raftery et al. | Reducing Gas Consumption in Existing Large Commercial Buildings | |
Kim et al. | Comparison between Current Industry Methods and an Energy Simulation Model for Quantifying Energy Service Projects | |
Toole et al. | Review on persistence of commissioning benefits in new and existing buildings | |
Noye et al. | Development of a portable wireless sensor network to enhance post-occupancy commissioning |