Li et al., 2015 - Google Patents
Development of a variable speed compressor power model for single-stage packaged DX rooftop unitsLi et al., 2015
View PDF- Document ID
- 4415167867187688731
- Author
- Li Y
- Liu M
- Lau J
- Publication year
- Publication venue
- Applied Thermal Engineering
External Links
Snippet
Variable speed technology was applied to compressors for rooftop units (RTUs) and heat pumps in recent years. Compressor power is a critical parameter to evaluate system performance and conduct fault detection and diagnosis (FDD). However, existing power …
- 238000011161 development 0 title description 4
Classifications
-
- F—MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
- F24—HEATING; RANGES; VENTILATING
- F24F—AIR-CONDITIONING, AIR-HUMIDIFICATION, VENTILATION, USE OF AIR CURRENTS FOR SCREENING
- F24F11/00—Control or safety systems or apparatus
- F24F11/0009—Electrical control or safety systems or apparatus
- F24F11/001—Control systems or circuits characterised by their inputs, e.g. using sensors
- F24F2011/0041—Pressure
- F24F2011/0042—Air pressure
-
- F—MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
- F24—HEATING; RANGES; VENTILATING
- F24F—AIR-CONDITIONING, AIR-HUMIDIFICATION, VENTILATION, USE OF AIR CURRENTS FOR SCREENING
- F24F11/00—Control or safety systems or apparatus
- F24F11/0009—Electrical control or safety systems or apparatus
- F24F11/0086—Control systems or circuits characterised by other control features, e.g. display or monitoring devices
- F24F2011/0091—Display or monitoring devices
-
- F—MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
- F25—REFRIGERATION OR COOLING; COMBINED HEATING AND REFRIGERATION SYSTEMS; HEAT PUMP SYSTEMS; MANUFACTURE OR STORAGE OF ICE; LIQUEFACTION SOLIDIFICATION OF GASES
- F25B—REFRIGERATION MACHINES, PLANTS OR SYSTEMS; COMBINED HEATING AND REFRIGERATION SYSTEMS; HEAT-PUMP SYSTEMS
- F25B2700/00—Sensing or detecting of parameters; Sensors therefor
- F25B2700/21—Temperatures
- F25B2700/2115—Temperatures of a compressor or the drive means therefor
- F25B2700/21152—Temperatures of a compressor or the drive means therefor at the discharge side of the compressor
-
- F—MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
- F25—REFRIGERATION OR COOLING; COMBINED HEATING AND REFRIGERATION SYSTEMS; HEAT PUMP SYSTEMS; MANUFACTURE OR STORAGE OF ICE; LIQUEFACTION SOLIDIFICATION OF GASES
- F25B—REFRIGERATION MACHINES, PLANTS OR SYSTEMS; COMBINED HEATING AND REFRIGERATION SYSTEMS; HEAT-PUMP SYSTEMS
- F25B2500/00—Problems to be solved
- F25B2500/19—Calculation of parameters
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Li et al. | Decoupling features and virtual sensors for diagnosis of faults in vapor compression air conditioners | |
Li et al. | Development of a variable speed compressor power model for single-stage packaged DX rooftop units | |
Bellanco et al. | A review of the fault behavior of heat pumps and measurements, detection and diagnosis methods including virtual sensors | |
Li | Simplified steady-state modeling for variable speed compressor | |
Kim et al. | Performance of a residential heat pump operating in the cooling mode with single faults imposed | |
Li | Simplified steady-state modeling for hermetic compressors with focus on extrapolation | |
Li et al. | Development, evaluation, and demonstration of a virtual refrigerant charge sensor | |
Romero et al. | A simplified black-box model oriented to chilled water temperature control in a variable speed vapour compression system | |
Kim et al. | Extension of a virtual refrigerant charge sensor | |
Du et al. | Effect of common faults on the performance of different types of vapor compression systems | |
Mehrabi et al. | Generalized effects of faults on normalized performance variables of air conditioners and heat pumps | |
Li et al. | Extending the virtual refrigerant charge sensor (VRC) for variable refrigerant flow (VRF) air conditioning system using data-based analysis methods | |
Cheung et al. | Simulation of fault impacts for vapor compression systems by inverse modeling. Part I: Component modeling and validation | |
Lumpkin et al. | Two-phase injected and vapor-injected compression: Experimental results and mapping correlation for a R-407C scroll compressor | |
Hu et al. | An experimental study of the behavior of a high efficiency residential heat pump in cooling mode with common installation faults imposed | |
Guo et al. | Development of a virtual variable-speed compressor power sensor for variable refrigerant flow air conditioning system | |
Kim et al. | Performance evaluation of a virtual refrigerant charge sensor | |
Li et al. | Experimental study on electrical signatures of common faults for packaged DX rooftop units | |
Janecke et al. | A comparison of static and dynamic fault detection techniques for transcritical refrigeration | |
Deymi-Dashtebayaz et al. | Experimental evaluation of refrigerant mass charge and ambient air temperature effects on performance of air-conditioning systems | |
Hu et al. | Impacts of common faults on an air conditioner with a microtube condenser and analysis of fault characteristic features | |
Cecchinato et al. | A simplified method to evaluate the seasonal energy performance of water chillers | |
Barta et al. | Experimental analyses of different control strategies of an R-410A split-system heat pump by employing a turbomachinery expansion recovery device | |
Zhang et al. | Transient modeling of an air conditioner with a rapid cycling compressor and multi-indoor units | |
KR20100108056A (en) | Real time performance evaluation method for ground source heat pump system and evaluation device programming the same |