Nothing Special   »   [go: up one dir, main page]

acson A5CM 15C Tavan Kaset Kullanma Kılavuzu
Tavan Kaset

 

Acson Ceiling Mounted Ecocool Series provides magnificent cooling comfort with a wide range of airthrow range and cost savvy on mind. Desired cooling comfort can be achieved rapidly through excellent air distribution. Reliable yet durable to deliver maximun air flow to the surroundings.
 Eko Soğuk
Acson Ceiling Cassette is equipped with R410A refrigerant gas. R410A refrigerant is a near-azeotropic mixture of 50% of R32 and 50% of R125 which contributes zero Ozone Depletion Potential (ODP). It is a greener choice compared to R22 refrigerant to preserve global climate changes. At Acson, we commit to bring the best air solutions by taking in environmentally-friendly consideration.
R22 refrigerant contributes 0.05 ODP
R410A refrigerant contributes 0 ODP

Common Installation Places

  1. Restaurant and Cafe Shop
    Ensuring every corners will be cooled and optimun cooling comfort will be achived especially for social gathering purposes. Optimun cooling temperature is vital to ensure customers’s comfort during social gathering.
    Tavan
  2. Lobi
    Lobi

    Hot air from outside easily circulated inside lobby with the frequent entry from outside. Acson Ceiling Mounted is able to maintain desired temperature with consistent optimun air distribution by motorized louver. A powerful airflow allows distribution of air from the upper and lower air outlets.
  3. School Hall
    School Hall

    Feel the fast cooling and powerful airflow especially at the fully-occupied hall. Hot air tends to stagnated at in fully-occupied hall which will bring discomfort and concentration will be disrupted. Acson Ceiling Mounted is able to provide powerful airfow which aids the circulation of the cool air.

Features of Ceiling Mounted

Aesthetically Compact Design
Kompakt Tasarım
Acson Ceiling Mounted Series has slim compact design for economical and space saving installation. The unit’s installation can be easily done without ceiling hacking.

Ceiling & Floor Installation Option
Ceiling Floor
Specially designed to provide versatility installation for the user. The user can choose whether ceiling mounted installation or floor mounted installation if there is no space at ceiling installation.

Powerful Airflow and Instant Cooling
Soğutma
Instant cooling and concentrated air flow will be distributed evenly across the room. Desired cooling comfort will be continously mantained to keep the occupants comfortable and relax
Durable and Accessible Saranet Filter
Filtre
İsteğe bağlı aksesuarlar 

  • Easi-Flo II
    Ease-Flo II
  • Easi-Flo 22
    Ease-Flo II
  • Easi-Flo 33
    Ease-Flo II
  • Easi-Flo 55
    Ease-Flo II

Power of Inverter
Acson Inverter technology controls the compressor’s speed accordingly to continuously regulate the room’s temperature. The compressor is not constantly running at full power, as the system utilizes a controlled compressor that works at variable speed settings. This consequently lead to much more energy-efficient and environmentally-friendly option than traditional AC.
ENERJİ TASARRUFU
ENERJİ TASARRUFU

High Efficiency Motors 
               +                High Efficiency Air-cond 
Akıllı Kontrol Sistemi

Acson R410A Inverter ultilizes hermetic swing compressor. It’s precise structure and mechanical movement help to reduce friction and vibration compared to conventional rotary compressor. This reduces refrigerant leakage and ensures maximun capacity is achieved.
Acson
Konfor Kontrolü
Non-Inverter System uses a fixed-speed compressor, which cycles the unit on and off once the room dips below desired temperature. This can lead to unpleasant temperature swings as the system need to mantain maintain a constant temperature. Inverter’s compressor speed is controlled at variable speed which provides a more precise, on-demand approach to temperature control.

Temperature Fluctuation During Cooling Operation
Sıcaklık dalgalanması
Çalışan Akım
Çalışan Akım

İnvertör
Gradual Increase ofcompressor rotation

NonInverter
High starting torque to start compressor from stationary compressor

İnvertör

  • Low starting current
  • Pürüzsüz çalışma

İnverter olmayan

  • High starting current
  • Frequent on/off cycle

Çalışma Saatleri

Enerji Tasarrufu

From an energy perspective, constantly turn on and off compressor can be a costly endeavor.

While inverter system is always on, running at a fraction of full speed is far more efficient in the long run. It’s estimated that non- inverter system systems draws higher power on start-up than inverter system.

MY Acson, MY Control (Optional Accessory)

MY Acson now offers smart functionality to boost your smart home experience. With MY Acson, you can convieniently control and monitor air conditoner units at anywhere and anytime.Instead of running for the AC remote controller as soon as you reach home, you can enjoy a cool breeze with few taps on your smartphone now.
*R410A CM Applicable Models:
A5CM-C Series
A5CMY- E Series (4.0HP & 5.0HP), NS Splitter is required.

Splitteer
Besides hassle- free from finding remote controller, all you need are MY Acson and your smartphone to improve your lifestyle, AC Usage, comfort and smart home experience.
Besides hassle

MY Acson App
A single swipe on the phone application which designed with simple control user interface. MY Acson is currently available for both Android & IOS system.Acson App
M Y AC S O N

Uygulama Mağazası
Google Oyun

MY Complete Control
Tam Kontrol

  • Setting different modes to suit your needs and comfort.
  • Controlling fan speed, air flow direction & temperature settings
  • Controlling the Zoning System

MY Convenience
Kolaylık

  • Set 7-day schedules & timers that adjust AC according to your lifestyle
  • Control every AC unit from your couch – no need to go racing room-to-room changing settings
  • Guest sharing option – possible to be both hospitable and safe

MY Comfort
Rahatlık

  • Pre-cool your room whilst still in the workplace or office.
  • Room is already pre-cooled according to your desired settings as you reach home.

Şartname

  Boyut Yükseklik (mm) 32
Genişlik (mm) 50
Derinlik (mm) 15
Wi-Fi Frekansı 2.4 GHz
Ağ Yapılandırması
Out-of-home Control İnternet
In-home Control LAN, Bluetooth
Elektriksel Özellikler
İletişim Protokolü NS
  Giriş Beslemesi Cilttage 5V
Akım 150mA
Güç Tüketimi 750 mW
Desteklenen İşletim Sistemi Android 5 or later; IOS 9 or later

Telefonlar
A5CK Series (R410A) 

 

Örnek

İç Ünite A5CM 15C A5CM 20C A5CM 25C A5CM 30C A5CM 30C A5CM 35C A5CM 40C A5CM 50C A5CM 62C
Dış Ünite A5LC 15F A5LC 20C A5LC 25C A5LC 28C A5LC 30C A5LC 35D A5LC 40D A5LC 50D A5LC 61D
 

Nominal Soğutma Kapasitesi

BTU / h 12,500 18,000 21,000 27,000 29,000 35,000 42,000 44,500 55,000
kW 3.66 5.27 6.15 7.91 8.49 10.25 12.31 13.04 16.11
Nominal Toplam Giriş Gücü W 1,270 1,760 2,020 2,820 2,950 3,800 4,100 4,900 6,414
Nominal Çalışma Akımı A 5.69 7.80 9.00 13.20 13.70 16.90 6.67 8.52 9.60
 

EER

BTU/h/W 9.84 10.23 10.40 9.57 9.83 9.21 10.24 9.08 8.57
A / A 2.88 3.00 3.05 2.81 2.88 2.70 3.00 2.66 2.51
Güç Kaynağı V / Ph / Hz 220-240/1/50 380-415/3/50
Soğutucu Akışkan Tipi R410A
 

 

 

 

 

 

 

 

 

 

 

 

İç Ünite

 

Kontrol

Operasyon KABLOSUZ KUMANDA
Hava tahliyesi MANUAL (UP & DOWN)
 

 

Hava akışı

Yüksek l/s / CFM 260 / 550 287 / 608 374 / 792 480 / 1015 552 / 1107 589 / 1247 732 / 1550
Orta l/s / CFM 228 / 484 276 / 586 334 / 707 439 / 930 471 / 999 560 / 1186 623 / 1320
Düşük l/s / CFM 180 / 382 220 / 466 289 / 613 353 / 749 354 / 751 525 / 1113 472 / 1000
Ses Basıncı Seviyesi (H/M/L) dBA 43 / 38 / 34 46 / 43 / 39 46 / 44 / 40 48 / 44 / 41 49 / 45 / 43 54 / 52 / 50 56 / 53 / 46
 

 

Birim Boyut

Yükseklik mm/ inç 235 / 9.25 285 / 11.2
Genişlik mm/ inç 1203 / 47.36 1553 / 61.14 1903 / 74.92
Derinlik mm/ inç 680 / 26.77
 

 

 

Paketleme Boyutu

Yükseklik mm/ inç 293 / 11.54 293 / 11.53 373 / 14.69
 

Genişlik

 

mm/ inç

 

1278 / 50.31

 

1628 / 64.09

 

1,978 / 77.87

2,011 /

79.17

Derinlik mm/ inç 749 / 29.49 749 / 29.49 749 / 29.49 793 / 31.22
Birim Ağırlık kg/ lb 30 / 66 31 /68 41 / 90 51 /112 52 /114 55 / 121 70 / 154
Yoğuşma Tahliye Boyutu mm/ inç 19.05 / 0.75
 

 

 

 

 

 

 

 

 

 

Dış Ünite

 

Hava akışı

 

l/s / CFM

 

390 / 827

 

675 / 1,430

 

755 / 1,600

 

808 / 1,712

1,416 /

3,000

 

1,487 / 3,150

1,812 /

3,840

Ses Basınç Seviyesi dBA 48 49 52 54 56 58 60 60 65
 

 

Birim Boyut

Yükseklik mm/ inç 550 / 21.65 651 / 25.63 753 / 29.65 852 / 33.54
Genişlik mm/ inç 658 / 25.91 855 / 33.66 1,030 / 40.55
Derinlik mm/ inç 273 / 10.75 328 / 12.91 400 / 15.75
 

 

Paketleme Boyutu

Yükseklik mm/ inç 580 / 22.83 693 / 27.28 793 / 31.22 1,010 / 39.76
Genişlik mm/ inç 775 / 30.51 990 / 38.98 1,180 / 46.46
Derinlik mm/ inç 355 / 13.98 415 / 16.34 415 / 16.34 415 / 16.34 514 / 20.24
Birim Ağırlık kg/ lb 29 / 63 43 / 94 47 / 103 57 / 125 57 / 125 71 / 156 84/185 105 / 232
 

Pipe Connection (Pipe Thickness)

Tip Flare Vana
 

Boyut

Sıvı mm/ inç 6.35 / 1 / 4 9.52 / 3 / 8
Gaz mm/ inç 12.7 / 1 / 2 15.88 / 5 / 8 19.1 / 3 / 4
Soğutucu Akışkan Şarjı kg/ lb 0.95 / 2.09 1.00 / 2.20 1.7 / 3.75 1.90 / 4.19 2.00 / 4.41 1.90 / 4.19 3.10 / 6.83 2.70 / 5.95 2.90 / 6.39

Notlar:

  1. All specifications are subjected to change by the manufacturer without prior notice.
  2. Normal Cooling Capacity is based in the conditions: Cooling 27°C DB/19°C WB indoor and 35°C DB/ 24°C WB outdoor.
  3. Sound Pressure Level is according to JIS B 8615 standard. Position of the measurement point is 1m in front and 1m below the unit.
  4. Units are tested & complied to international standards such as ISO 5151.

A5CMY E & C Inverter Series

 Örnek İç Ünite A5CMY 40E A5CMY 50E A5CMY 62C
Dış Ünite A5LCY 40FR A5CMY 50FR A5LCY 60FR
 Nominal Soğutma Kapasitesi BTU / h 34,100 42,600 44,300
W 10,000 12,500 13,000
Nominal Toplam Giriş Gücü W 3,280 4,150 4,890
Nominal Çalışma Akımı A 14.90 6.47 7.54
 EER BTU/h/W 10.41 10.27 9.07
A / A 3.05 3.01 2.66
Güç Kaynağı V / Ph / Hz 380-415 / 3 / 50
Soğutucu Akışkan Tipi R410A
           İç Ünite  Kontrol Operasyon WIRELESS AND WIRED
Hava tahliyesi AUTOMATIC LOUVER UP AND DOWN
  Hava akışı Yüksek l/s / CFM 520 (1,100) 570 (1,215) 732 (1,550)
Orta l/s / CFM 464 ( 983) 511 (1,082) 651 ( 1,320)
Düşük l/s / CFM 414 ( 877) 453 (959) 472 (1,000)
Ses Basıncı Seviyesi (H/M/L) dBA 52/47 /46 52 / 50 / 49 56 / 53 / 46
  Birim Boyut Yükseklik mm/ inç 260 (10.24) 285 (11.22)
Genişlik mm/ inç 1,538 (60.55) 1,786 (70.31) 1,903 (74)
Derinlik mm/ inç 634 608
  Paketleme Boyutu Yükseklik mm/ inç 330 (12.99) 351 (13.82)
Genişlik mm/ inç 1,645 (64.76) 1,892 (74.49) 2,016 (79.37)
Derinlik mm/ inç 724 (28.50) 788 (31.02)
Birim Ağırlık kg/ lb 45 (99.21) 65 (143.30) 70 (154.32)
Yoğuşma Tahliye Boyutu mm/ inç 19.1 (3/4)
         Dış Ünite Hava akışı l/s / CFM 1553/3290 1534/3250
Ses Basınç Seviyesi dBA 50 51 51
  Birim Boyut Yükseklik mm/ inç 1,374 (54.09)
Genişlik mm/ inç 900 (35.43)
Derinlik mm/ inç 320 (12.60)
  Paketleme Boyutu Yükseklik mm/ inç 1,529 (60.20)
Genişlik mm/ inç 1,030 (40.55)
Derinlik mm/ inç 421 (16.57)
Birim Ağırlık kg/ lb 100 (220.46)
 Pipe Connection (Pipe Thickness) Tip Flare Vana
 Boyut Sıvı mm/ inç 9.52 (3/8)
Gaz mm/ inç 15.88 (5/8)
Soğutucu Akışkan Şarjı kg/ lb 4.3 /9.48

Notlar:

  1. All specifications are subjected to change by the manufacturer without prior notice.
  2. Normal Cooling Capacity is based in the conditions: C
  3. ooling 27°C DB/19°C WB indoor and 35°C DB/ 24°C WB outdoor
  4. Units are tested & complied to international standards such as ISO 5151.

ACSON MALAYSIA SALES & SERVICE SDN.BHD. üyesi DAIKIN grup
İşletme Kayıt NO.1913401017130 (129688-D)
Lot 4, Lorong 19/1A, Seksyen 19, 46300 Petaling Jaya, Selangor Darul Ehsan, MALAYSIA.
Telefon : +603 7964 8200 Sales
Faks : +603 7956 9909 Service
Faks : +603 7956 9907 Acson Careline • 1300 22 3344
Penang Perak Melaka Johor
: +604-5377 176 :+605-3129 828 : +606-2926196 :+607-3551 599
www.acson.com.benim
CAT-A5C M-2103
Pahang Kelantan Sarawak Sabah
: +609-5178 696 : +609-7405 233 :+6082-344 128 : +6088-420 205
Authorized Dealer :
Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information, please logon to www.acson.com.benim

Belgeler / Kaynaklar

acson A5CM 15C Ceiling Cassette [pdf] Kullanım Kılavuzu
A5CM 15C Ceiling Cassette, A5CM 15C, Ceiling Cassette, Cassette

Referanslar

Yorum bırakın

E-posta adresiniz yayınlanmayacak. Gerekli alanlar işaretlenmiştir *