tiba UV 511053 300x300mm Mwongozo wa Mtumiaji wa Safu ya LED ya UV
Vipengele vya mtawala
- Touch screen display , simple and intuitive operation .
- Support external dry contact to control UVLED switch and alarm output (dry contact).
- Support the standard RS485 communication protocol to facilitate the communication of peripheral devices .
- Real-time monitoring of temperature , effectively protecting the stable operation of LED , and with over temperature protection and alarm function.
- Support automatic irradiation function, can count down the irradiation time, and can also recordthe total irradiation time.
Main performance and parameters of the product
Vipimo vya mtawala | 384mm * 284mm * 100mm (L*W*H) |
Lamp vipimo | L430 x W390 x H100mm |
Ugavi wa nguvu | Single-phase AC220V 60HZ |
Equipment power consumption | 1000W (current 5A) Max |
Emitting window | 300mm*300mm |
urefu wa mawimbi | 365nm, 385nm, 395nm, 405nm |
Nguvu ya macho | 584mW/cm² |
Mbinu ya baridi | air cooled |
Net weight of equipment | Kilo 20 |
Joto la Uendeshaji | -10 ℃– 50 ℃ (non-corrosive, dust-free) |
Unyevu wa mazingira ya kazi | 10%–80% RH isiyopunguza |
Equipment installation and connection
Muundo wa bidhaa
Kidhibiti
UV LEDLAMP
Vipimo vya Bidhaa
Ukubwa wa kidhibiti
UV LED lamp ukubwa

Schematic diagram of product installation

UV LED controller device name and function
1 |
UV LED connector |
UV LED connection port (female) |
2 |
Bandari ya mawasiliano ya RS485 |
Can be used to read and write external parameters |
3 |
Input /Output IO terminal |
|
4 |
cable ya nguvu |
Ingizo la nguvu za nje |
5 |
swichi ya rocker |
Master main power switch |
Connection of UV LED light source
Align the connection port for the UV LED light source (female) on the back of the main controller with the dimpled side of the connector for the UV LED light source (male), and push the back half of the connector to insert. After insertion, it is necessary to turn the rotatable part counterclockwise until it is tightened.
Basic operation and setting of equipment
Anza na kuzima
Before starting , first check whether the UV-LED light source connection cable and power cable are connected , then turn on the power, the main power switch of the controller . When shutting down, please turn off the UV-LED light source first, then turn off the main power switch , finally unplug the power cord.
Uendeshaji wa kazi
Kiolesura kikuu | Onyesha maudhui |
Mbinu ya kudhibiti | Manual control, automatic control |
Irradiation method | Irradiation power and time setting, total irradiation timequery and reset |
Ufuatiliaji wa joto | Set the alarm temperature and display the light source temperature in real time |
Mpangilio wa mfumo | weka upya |
Entering irradiation | Click the button to enter the irradiation interface |
Irradiation Parameters | View parameters such as irradiation power, irradiation time, and alarm temperature |
Mbinu ya kudhibiti
Hali ya udhibiti |
Click switch to |
Click to switch to |
Irradiation method
Irradiation power |
Click the number in the irradiation power box to pop up the input keyboard, enter the required value and click Enter to confirm . Irradiation power input range 1 -100% |
Irradiation time | Click the number in the irradiation time space to pop up the input keyboard, type in the required value and click Enter to confirm . Irradiation time input range 0 – 9999 seconds |
Ucheleweshaji wa mashabiki | Time setting for delaying turning off the fan after the UVLED is turned off |
Total irradiation time | Record the total irradiation time of the UV lamp . You can click Clear to clear the total irradiation time . Clearing requires an administrator password . |
Ufuatiliaji wa joto
Weka halijoto | Click the number in the set temperature box to pop up the inputkeyboard, enter the value you need and click Enter to confirm. The setting value range is between 0°C and 65 °C . |
Ya sasa | The current temperature displays the temperature of the UV-LED light |
Halijoto | source in real time. When the current temperature exceeds the set temperature, the UV-LED light source will stop working and send an alarm signal. |
Mipangilio ya Mfumo
Click System Settings to enter the administrator password to enter the system settings interface.
Nenosiri la msimamizi: 123456, non-professionals do not modify parameters
Weka upya kiwandani |
Click ‘restore factory settings’ to restore the original factory data: the irradiation power is 80 % , the irradiation time is 60 s , and the temperature monitoring is set to 65 ℃. |
Urekebishaji wa joto | Manufacturer parameters, please do not operate! |
Entering irradiation
WASHA/ZIMWA | Kitufe cha kuanza na kuacha |
Rudi | Click the Return button to return to the main interface and close the irradiation at the same time. |
Irradiation parameters
Click the “Irradiation Parameters” to view parameters such as irradiation power, time, and alarm temperature.
High temperature fault alarm
When the UV-LED light source is running, if the temperature of the UV-LED light source is higher than the set temperature, the UV-LED light source will automatically turn off and an alarm signal will be issued . When the urrent temperature of the UV-LED light source is lower than the set temperature, the alarm signal will be activated. Automatically cancel.
Operesheni Example
Otomatiki hali ya udhibiti | 1. Bofya |
Modifying Irradiation Parameters | 2. Bofya |
Entering irradiation | 3. Bofya |
Njia ya udhibiti wa mwongozo | 1. Bofya |
Modifying Irradiation Parameters | 2. Bofya |
into irradiation | 3. Bofya |
Peripheral equipment connection
I/O signal port RS485 communication
IO signal port | Kazi | |
G1 NO1 | Short-circuit the signal to turn on the light , and short-circuit the external relay to control the light on and off. | |
Alarm1, Alarm1 | Alarm output signal, relay dry contact signal. | |
NC、NC | Light source not connected to output signal, relay dry contact signal. | |
RS485mawasiliano | From top to bottom A+ B- FG, used for reading and writing external parameters. |
Itifaki ya mawasiliano ya RS485:
The UV LED controller uses a standard RS 485 Modbus-RTU interface, with a baud rate of 115200 , no check digit, 8 data bits, and 1 stop bit ( 115200 N 8 1).
Register description:
00 | The factory default address of this machine is ‘ 0 ‘ (range: 0 -255)supports read/write |
01 | UVLED output power setting address (Range: 1 -100%) supports read/write |
02 | Manual/automatic mode setting address (0: manual 1: automatic)supports read/write |
03 | Irradiation time setting address ( range: 0-9999 seconds) supports read/write |
04 | Alarm temperature setting address (Setting range: 0 °C -65 °C )Support read/write |
05 | current temperature address read only |
06 | NC |
07 | Turn on/off UVLED address (0: off 1: on) support write |
The UVLED host supports instruction codes:
0 3 | Read the function code to read the parameter as a hexadecimal number |
0 6 | The parameter written in the function code must be hexadecimal number |
Parameter read and write instruction format :
- UV LED host address modification command format (hexadecimal) such as: No. 0 address changed is to No. 1 address ( after the device address is modified, the host needs to be restarted to take effect )
anwani ya kifaa nambari ya kazi anwani ya usajili data kidogo Angalia CRC 0 0 06 00 00 00 0 1 08 0B - UV LED host output power setting command format (hexadecimal) such as: set 50%poweroutput (decimal 50 to hexadecimal 32) if the device address is ‘ 0 ‘
anwani ya kifaa nambari ya kazi anwani ya usajili data kidogo Angalia CRC 0 0 06 00 01 00 32 59 DF - UV LED host automatic irradiation time setting command format (hexadecimal) suchas: set irradiation 1 0 0 seconds, that is 100 (decimal 100 is converted to hexadecimal 64) if the device address is ‘ 0 ‘
anwani ya kifaa nambari ya kazi anwani ya usajili data kidogo Angalia CRC 0 0 06 00 03 00 64 78 twenty one - UV LED lamp real-time temperature reading command format (hexadecimal) if the device address is ‘ 0 ‘
anwani ya kifaa nambari ya kazi anwani ya usajili Read the number of registers Angalia CRC 0 0 03 00 05 00 01 94 0B
Thamani ya kurejesha: (0 0 03 00 05 22 9A CD ) ’22’ is the real-time temperature value in hexadecimal, and 34 ℃ in decimal
Makosa ya kawaida na suluhisho
Dalili | sababu ya suala | Mbinu |
kengele ya joto | Halijoto ni ya juu sana | Check whether the cooling fan is normal |
Sensor ya joto imeharibiwa | Enable backup sensor | |
UV-LED not bright | Kiunganishi | Check whether the connector is connected properly |
no power on | Poor contact of the power cord | Check the power interface and whether the power cord plug is in good contact. |
swichi ya rocker | Is the switch on |
Matengenezo ya vifaa
- Clean the surface dust every day to keep the body clean, and clean the dust of the cooling fan port regularly to keep the cooling channel normal (normally cleaned once a month, depending on the environment).
- Turn on the light to check whether the UV lamp is irradiated according to the set power, if it is abnormal, stop working, contact the staff for inspection, or contact the manufacturer.
- Equipment running for a month should be systematic maintenance, UVLED glass inspection, to see whether the pollution, UV lamp aging and other work.
Tahadhari
- Do not direct UV light to the eyes or skin, as it may cause damage .
- Do not disassemble the UV-LED irradiation may cause UV light leakage .
- When installing or removing the UV-LED irradiation head, be sure to cut off the power supply.
- When cleaning the irradiation head and controller regularly, please do not use thinner, volatileoil,acetone, kerosene, etc. You can use a soft cotton cloth to spot a small amount of ethanol andwipecarefully .
- Please use this machine in a cool, dry, ventilated environment without high magnetic field or high electric field.
- Please use the DC power supply specially provided by our factory for the power adapter.
- Do not open the controller privately to prevent the danger of electric leakage
This document is copyright@ November 01, 2024 SPDI, Inc. All rights reserved. This document is provided for information purposes only. Contents are subject to change without notice. It is not warranted to be error-free. Nor subject to any other warranties or conditions including implied warranties and conditions of merchantability or fitness for a particular purpose.
hone: 800-977-7292
Anwani: 2801 Rosselle St Jacksonville, FL 32205
Web duka: www.cureUV.com
Nyaraka / Rasilimali
cure uv 511053 300x300mm UV LED Array [pdf] Mwongozo wa Mtumiaji 511053 300x300mm UV LED Array, 511053, 300x300mm UV LED Array, UV LED Array, LED Array, Array |
Marejeleo
-
Uponyaji wa UV Lamps, Balbu za UV-C Sterilizer, Mifumo ya Tiba ya Ultraviolet - CureUV
-
Uponyaji wa UV Lamps, Balbu za UV-C Sterilizer, Mifumo ya Tiba ya Ultraviolet - CureUV
- Mwongozo wa Mtumiaji