Техникалық сипаттамалар

  • Үлгі: NFA-T01SD
  • Түр: Intelligent Addressable Optical Smoke Detector
  • Сәйкестік: EN 54-7:2018
  • Өндіруші: Norden Communication UK Ltd.

Өнімді пайдалану нұсқаулары

  • Before starting the installation process, ensure that you have read the instruction manual carefully.
  • Follow the wiring diagram provided in the manual to correctly wire the smoke detector to the system.
  • Prior to configuration, ensure the smoke detector is correctly installed and powered.
  • Follow the steps outlined in the manual to assign a unique address to the smoke detector for identification within the system.
  • You can configure the LED indicator to be on or off based on your preference or system requirements.
  • To verify the configuration settings, follow the instructions to read the current setup of the smoke detector.
  • Regularly clean the smoke detector using a soft cloth to remove dust or debris that may affect its performance.

Өнім қауіпсіздігі

To prevent severe injury and loss of life or property, read the instructions carefully before installing the detector to ensure proper and safe operation of the system.

Кіріспе

Біттіview

  • The NFA-T01SD Intelligent Addressable Optical Smoke Detector is well-suited for a wide range of applications, thanks to its excellent linear response to various smoke patterns.
  • Manufactured to meet the sensitivity requirements of the European Standard EN 54 part 7, this unit features an aesthetically pleasing and unobtrusive design that complements modern building aesthetics.
  • Additionally, it incorporates an intelligent processor with features such as an Algorithm map, inbuilt A/D converter, Drift compensation, and Self-Diagnosis and History log.
  • The Intelligent Addressable Optical Smoke Detector ensures secure and rapid communication through its onboard processor, allowing the detector to make autonomous decisions for greater automation.
  • During a fire event, the integral microprocessor analyzes the signal based on factors like signal strength and rate of increase.
  • It then cross-references these patterns with pre-programmed fire scenarios and smoke patterns, resulting in a faster and safer response.
  • Once confirmed, the LED indicates the sensor status and simultaneously sends a communication signal to the control panel.
  • The NFA-T01SD detector seamlessly integrates with the NFA-T04FP Intelligent Addressable Fire Alarm Control Panel and eliminating any addressable communication compatibility issues.

Ерекшелігі мен артықшылықтары

  • EN54-7 Сәйкестік
  • Using microprocessor technology with a memory capacity up to 10 events
  • Analog sensing and digital addressing
  • Provide real-time algorithm to the control panel
  • Smart linear drift compensation
  • Onsite adjustable parameter
  • 360-degree visual indicator
  • Removable chamber against dust and small insect
  • Ancillary remote indicator output
  • Эстетикалық тартымды дизайн

Техникалық спецификация

  • Listed LPCB Certification
  • Compliance EN54-7:2018
  • Кіріс көлеміtage 24VDC [16V to 28V]
  • Current Consumption Standby 0.6mA, Alarm: 4mA
  • Protocol/addressing Norden, Мән диапазоны 1-ден 254-ке дейін
  • Sensitivity As per the stipulated standard
  • Indicator Single LED / 360-degree Visual
  • Материал / Түс ABS / Ақ Жылтыр әрлеу
  • Dimension / Height Diameter 99.7 mm / 57 mm
  • Салмағы 145г (негізімен), 90г (негізсіз)
  • Жұмыс температурасы -10 ° C -тан +50 ° C -қа дейін
  • Ылғалдылық 0-95% Салыстырмалы ылғалдылық, Конденсацияланбау

Орнату

Орнатуға дайындық

  • This detector must be installed, commissioned, and maintained by qualified or factory-trained service personnel.
  • The installation must be installed in compliance with all local codes having jurisdiction in the area or BS 5839 Part 1 and EN54.
  • The Intelligent Addressable Optical Smoke Detector operates on the principle of infrared light refracting off smoke particles entering the chambers.
  • This makes the detector more sensitive to smouldering fires such as modern fabric or furnishing. Optical detectors are more prone to false alarm from steam or dusty environments.

For the best sensing ability, avoid installing smoke detectors in these areas.

  • In open-air applications the detectors require ceilings to direct the smoke from the plume by convection.
  • On side walls, this will severely delay the response time of a detector and where ceiling heights exceed 10.5m.
  • In Rooms where cooking will take place such as kitchens, or similar areas where steam and condensation are present.
  • Where exhaust fumes are present like car parks.
  • Where smoke particles will not be produced by fire.
  • Plant Rooms (unless full discussions regarding the room contents and status subject to fire have been made between Client and Manufacturer), Boiler, and Generator Rooms.

Орнату және сымдар

  1. Mount the NFA-T01NB Normal base on standard one [1] gang electrical back box. Do not over-tighten the screws otherwise, the base will twist. Use M4 standard screws.
  2. Connect the wire in the terminal as shown in Figure 2 [2]. Verify the device number or other device parameters if desired using a programming tool then stick them on the label before attaching the detector. The sticker labels are available on the control panel.
  3. Attach the detector to the base, point the detector in the base by the mark line and secure the detector in that position by rotating it clockwise, until it reaches the next mark line.
  4. Do not remove the red plastic dust cover until the final handover is done.
  5. The connecting line of the emote indicator should be less than 30 meters.

NORDEN-NFA-T01SD-Optical-Smoke-Detector -FIG-2

Терминал сипаттамасы

NORDEN-NFA-T01SD-Optical-Smoke-Detector -FIG-3

  1. Signal In (+)
  2. Signal Out (+)
  3. Remote Indicator (+)
  4. Remote Indicator (+)
  5. Signal In (-)
  6. Signal Out (-)
  7. Remote Indicator (-)
  8. Remote Indicator (-)

Детектор конфигурациясы

Дайындық

  • The NFA-T01PT programming tool is used to configure the smoke detector’s soft address and parameter.
  • This Programming tool is not included, must be purchased separately. The programming tool is packed with a twin 1.5V AA battery and cable, ready for usage once received.
  • The commissioning personnel must have a programming tool in order to adjust the detector according to the site situation and environmental requirements.
  • Program a unique address number for each device according to the project layout before placing it from the Terminal Base.
  • Ескерту: Бағдарламалау құралына қосылу кезінде цикл қосылымын ажыратыңыз.

Жазыңыз: адрестеу

  1. Connect the programming cable to 1 and 6 terminals (Figure 3). Press “Pow-er” to switch on the unit.
  2. Switch on the programming tool, then press the button “Write” or number “2” to enter Write Address mode (Figure 4 ).
  3. Input the desired device address value from 1 to 254, and then press “Write” to save the new address (Figure 5). Note: If displayed “Success”, means the entered address is confirmed. If display “Fail”, means failure to program the address (Figure 6).NORDEN-NFA-T01SD-Optical-Smoke-Detector -FIG-4NORDEN-NFA-T01SD-Optical-Smoke-Detector -FIG-5
  4. Press the “ Exit” key to go back Main Menu. Press the “ Power” key to switch off the programming tool.

Set: LED On/Off

  1. The LED indicator can be turned off if desired, the sensing ability of the detector will not be disrupted even the LED is off.
  2. Attach the programming cable to 1 and 6 Terminals of the detector. Press “Power” to switch on the unit.
  3. Switch on the programming tool, then press button “4” to enter to Setting mode (Figure 7).
  4. Input the “1” and then press “Write” to change the setting (Figure 8) and the LED will turn off. To resume the default setting, press “Clear” and then press “Write”.NORDEN-NFA-T01SD-Optical-Smoke-Detector -FIG-6
  5. Press the “Exit” key to go back to the Main Menu. Press “Power” to switch off the programming tool.

Конфигурацияны оқыңыз

  1. Attach the programming cable to the 1 and 6 terminals of the detector. Press “Power” to switch on the unit.
  2. Switch on the programming tool, then press the button “Read” or “1” to enter to Read mode (Figure 9). The programming tool will display the configuration after a few seconds. (Figure 10).NORDEN-NFA-T01SD-Optical-Smoke-Detector -FIG-7
  3. Негізгі мәзірге оралу үшін «Шығу» пернесін басыңыз. Бағдарламалау құралын өшіру үшін «Қуат» түймесін басыңыз.

Жалпы техникалық қызмет көрсету

  1. Техникалық қызмет көрсетуді бастамас бұрын тиісті персоналға хабарлаңыз.
  2. Disable the detector on the control panel to prevent false alarms.
  3. Do not attempt to adjust or modify the detector, it may affect the ability of the detector to respond to a fire condition and will void the manufacturer’s warranty.
  4. Жарнаманы пайдаланыңызamp cloth to clean the detector. Do not use cleaning chemicals that may leave residue on the electronic parts and smoke chamber.
  5. Notify again proper personnel after conducting the maintenance and make sure to enable the detector and confirm if it is up and running.
  6. Perform the maintenance semi-annually or quarterly depending on the site conditions.

Тазалау

  1. Remove the detector cover by snooping away the four sides tabs using a flat screwdriver and then pulling the cover from the base. (Figure 11).
  2. Remove the protective screen by pulling it straight out. (Figure 12).
  3. Carefully vacuum the chamber and screen. If there is a stain, wash with running water and ensure it is completely dry.
  4. Position the chamber and screen by aligning three tiny holes over the sensing component. (Figure 12).
  5. Align the LED tube and tabs and gently push the cover until it locks into place. (Figure 12).
  6. Re-install and test the detector.

NORDEN-NFA-T01SD-Optical-Smoke-Detector -FIG-8

Ақаулықтарды жою жөніндегі нұсқаулық

Сіз байқаған нәрсе Бұл нені білдіреді Не істеу керек
Мекенжай тіркелмейді Сымдар бос

Мекенжай телнұсқа болып табылады

Техникалық қызмет көрсету

Құрылғыны қайта іске қосыңыз

Іске қосу мүмкін емес Зақым электронды тізбекте Детекторды ауыстырыңыз
Keep Indicating the Fire signal The detector chamber is dirty Детекторды тазалаңыз

1-қосымша

  • Limitation of Intelligent Addressable Optical Smoke Detector
  • The smoke detector is designed for triggering and initiating emergency fire equipment, however it only functions when matching with other equipment.
  • The installation of this smoke detector must conform to electrical codes and country standards.
  • All kinds of smoke detectors have restrictions, since fire develops in various ways and is often unpredictable in its progression, it is unforeseen which type of detector will provide the earliest warning.
  • No type of smoke detector can sense every form of fire all the time.
  • Detectors may not warn you about a fire caused by insufficient safety measures, violent explosions, leaking gas, improper storage of flammable materials like diluents and other safety hazards, arson or children playing with fire.
  • The alarm of a smoke detector used in a igh-velocity environment will be delayed due to the dilution of smoke by frequent and fast airflow.
  • What’s more, the smoke detector must be frequently maintained for it is exposed to more dust contamination.
  • The smoke detector cannot last forever. To keep the detector working in good condition, please maintain the equipment continuously according to recommendations from manufacturers and relative national codes and laws.
  • Take specific maintenance measures based on different environments.
  • The smoke detector contains electronic parts. Even though it is made to last for a long period, any of these parts could fail at any time.
  • Therefore, test your smoke detector at least every half-year according to national codes or laws. Any smoke detectors, fire alarm devices, or any other components of the system must be repaired and/or replaced immediately if they fail.

Жиі қойылатын сұрақтар

  • Q: How often should I perform maintenance on the smoke detector?
  • A: It is recommended to perform general maintenance, including cleaning, at least once every six months to ensure optimal performance.

Еуропалық Одақ директивасы
2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information, please visit the webсайтында www.recyclethis.info

NORDEN-NFA-T01SD-Optical-Smoke-Detector -FIG-1

EN54 7-бөлім Сәйкестік

  • NFA-T01SD Intelligent Addressable Optical Smoke Detector complies with the requirements of EN 54-7:2018.

БАЙЛАНЫС

NORDEN-NFA-T01SD-Optical-Smoke-Detector -FIG-9

Құжаттар / Ресурстар

NORDEN NFA-T01SD Optical Smoke Detector [pdf] Нұсқаулық
NFA-T01SD Optical Smoke Detector, NFA-T01SD, Optical Smoke Detector, Smoke Detector, Detector

Анықтамалар

Пікір қалдырыңыз

Электрондық пошта мекенжайыңыз жарияланбайды. Міндетті өрістер белгіленген *